1.A shear bond strength of resin cement bonded to human uncut enamel, cut enamel, and dentin in vitro.
The Journal of Korean Academy of Prosthodontics 2003;41(3):319-324
STATEMENT OF PROBLEM: Adhesives in dentistry play a major role in the success of restorative treatments. In the treatment of all ceramic restoration it is needed to find the adequate bond strength between enamel and dentin. PURPOSE: The purpose of this study was to evaluate shear bond strength of resin cement bonded to extracted human uncut enamel, cut enamel, and dentin in vitro. MATERIAL AND METHODS: Ten freshly extracted anterior teeth without any previous restorative treatments were chosen. The extracted teeth were embedded in PMMA cold acrylic in the shape of a cylinder, 25 mm in diameter by 25 mm in height. The bonding system used was as follow: Uni-Etch (32 % phosphoric acid), One-Step adhesive, Duolink resin cement. The specimens were acid etched and rinsed with water. Two layers of One-Step adhesive were coated with a disposable brush on the uncut enamel. VIP curing light at 500 mV/cm2 was used to cure the adhesive. For cut enamel shear bond test, the specimen used for uncut enamel was further reduced approximately 0.3 - 0.5 mm using a laminate preparation diamond bur (0.3 mm in depth). The specimens were subsequently treated with 320-grit SiC paper followed by 600-grit SiC paper and cleaned with distilled water. The bonding procedure on the cut enamel was same as uncut enamel bonding procedure. For dentin bonding test, the specimen used for cut enamel was further reduced approximately 0.5 mm ~ 1.0 mm using a laminate preparation diamond bur (0.5 mm in depth of diamond cutting). The amount of reduction was evaluated with the silicone mold. The specimens were subsequently treated with 320-grit SiC paper followed by 600-grit silicon carbon paper and cleaned in distilled water. The bonding procedure on the dentin was same as uncut enamel bonding procedure. All samples were mounted and secured on the Ultradent shear bond test sample holder, and Ultradent restricted shear bond testing device was used with Universal Instron machine until fracture. Analysis of variance (ANOVA) test was performed comparing the result at P<0.05. Multiple comparison (Tukey) was used to compare each groups. RESULT: The result showed that the mean value in shear bond strength of resin cement bonded to uncut enamel, cut enamel and dentin were 27.04 Mpa, 30.25 Mpa and 26.39 Mpa with respect. CONCLUSION: Within the limitation of this study, the mean value of the shear bond strength of cut enamel was higher than those of uncut enamel or dentin. However there existed no statistical differences between three different human dentition substrates due to increased adhesive characteristics.
Adhesives
;
Carbon
;
Ceramics
;
Dental Enamel*
;
Dental Instruments
;
Dentin*
;
Dentistry
;
Dentition
;
Diamond
;
Fungi
;
Humans*
;
Polymethyl Methacrylate
;
Resin Cements*
;
Silicones
;
Tooth
;
Water
2.A shear bond strength of resin cements bonded to pressable porcelain with various surface treatments.
The Journal of Korean Academy of Prosthodontics 2003;41(3):379-386
STATEMENT OF PROBLEM: Resin cements are widely used in adhesive dentistry specially on all ceramic restorations. It is needed to find out adequate bonding strength between different porcelain surface treatments, commercially available porcelains, and different resin cement systems. PURPOSE: The purpose of this study was to evaluate shear bond strength of resin cements bonded to porcelains in three different modalities; 5 different porcelain surface treatments, 3 different resin cement systems and 3 different commercially available pressable porcelains. MATERIAL AND METHOD: This study consisted of 3 parts. Part I examined the effect of five different surface treatments on the pressable porcelain. Fifty discs (5 mm in diameter and 3 mm in height) of Authentic porcelain were randomly divided into 5 groups (n = 10). The specimens were sanded with 320 grit SiC paper followed by 600 grit SiC paper. The specimens were treated as follow: Group 1-Sandblasting (aluminum oxide) only, Group 2 - sandblasting/silane, Group - sandblasting/acid etching/silane, Group 4 - acid etching only, Group 5 - acid etching/silane. Part II examined the shear bond strength of 3 different resin cement systems (Duolink, Variolink II, Rely X ARC) on acid etching/ silane treated Authentic pressable porcelain. Part 3 examined the shear bond strength of Duolink resin cement on 3 different pressable porcelains (Authentic, Empress I, Finesse). All cemented specimens were stored in distilled water for 2 hours and tested with Ultradent shear bond strength test jig under Universal Instron machine until fracture. An analysis of variance(ANOVA) test was used to evaluate differences in shear bond strength. RESULT: The shear bond strength test resulted in the following: (1) Acid etched porcelains recorded greater shear bond strength values to the sandblasted porcelains. (2) Silane treated porcelains recorded greater shear bond strength values to non-silane treated porcelains. (3) There was no significant difference between sandblasting/acid etching/silane teated and acid etching/silane treated porcelains. However those values were much higher than other three groups. (4) The shear bond strength with Variolink II was lower than the value of Duolink or Rely X ARC. (5) The shear bond strength of Finesse was lower than the value of Authentic or Empress I.
Adhesives
;
Ceramics
;
Dental Porcelain*
;
Dentistry
;
Resin Cements*
;
Silicon Dioxide
;
Water
3.Quality of Life(QOL), Life Satisfaction, and Its Determinents of the Physically Disabled in Taegu City .
Youg Sook LEE ; Keon Yeop KIM ; Ki Soo PARK ; Jae Hee SON ; Jong Young LEE
Korean Journal of Preventive Medicine 1998;31(3):503-515
In order to investigate the factors influencing QOL and life satisfaction of the physically disabled, the author interviewed, by using structuralized questionnaire, 440 individuals among the physically disabled who were participated in Health Examination from April to July, 1997. The questionnaire consisted of the general characteristics(sex, age, marital status, family number, etc), the Reintegration to Normal Living Index(RNLI) to assess QOL, and the single item of five-likert scale to evaluate life satisfaction. The means of RNLI were 16.2+/-4.8 in total score, 12.2+/-3.4 in daily functioning and 4.0+/-2.1 in perception of self. The respondents were less reintegrated toward social activities and relationships than impairments or disabilities. While the satisfied group was 47.3%, the dissatisfied group was 52.7%. As the results of multiple regression and logistic regression analysis, the significant predictors of QOL were age, education, job, grade of disability and subjective health status. The life satisfaction were related to economic status, job and subjective health status. To improve QOL and life satisfaction of the physically disabled, it is important that we improve their basic socioeconomic status by getting a job through rehabilitation education and induce them to have positive self-assessment by extending the opportunity of social participation.
Daegu*
;
Surveys and Questionnaires
;
Disabled Persons*
;
Education
;
Humans
;
Logistic Models
;
Marital Status
;
Surveys and Questionnaires
;
Rehabilitation
;
Self-Assessment
;
Social Class
;
Social Participation
4.A Case of Malignant Glaucoma-like Phenomenon During Cataract Surgery.
Sang Yeop LEE ; Jong Woon PARK
Journal of the Korean Ophthalmological Society 2010;51(8):1150-1154
PURPOSE: Malignant glaucoma is a rare complication of anterior segment surgery. The authors present a case of a malignant glaucoma-like phenomenon during cataract surgery in a primary open-angle glaucoma (POAG) patient. CASE SUMMARY: A 74-year-old man with POAG underwent a cataract surgery in his left eye. After phacoemulsificiation, sodium hyaluronate was used to form the capsular bag for intraocular lens implantation. Following this procedure, the capsular bag space and anterior chamber became shallow. Intraocular pressure (IOP) elevated, and the shallowing of the anterior chamber and capsular bag space continued to a dangerous level. The surgical procedure was stopped and postponed for two days. After two days, IOL was successfully implanted in the posterior bag. CONCLUSIONS: Although the preoperative ophthalmologic examination failed to reveal a zonular problem, there was a possibility for a small area of zonular defect. A malignant glaucoma-like phenomenon was suspected to have occurred due to leakage of sodium hyaluronate or balanced salt solution into the vitreous through a small area of zonular dialysis. If a similar condition, occurs delayed surgery for IOL implantation would be more effective than vitrectomy or laser treatment.
Aged
;
Anterior Chamber
;
Cataract
;
Dialysis
;
Eye
;
Glaucoma
;
Glaucoma, Open-Angle
;
Humans
;
Hyaluronic Acid
;
Intraocular Pressure
;
Lens Implantation, Intraocular
;
Vitrectomy
5.A Case of Malignant Melanoma Arising in a Long Standing Melanocytic Nevus on the Palm.
Jong Hee LEE ; Jong Yeop YOO ; Kwang Hyun CHO
Korean Journal of Dermatology 2001;39(10):1169-1172
We present a case of malignant melanoma arising in a longstanding melanocytic nevus on the palm. Histological examination showed mature nevoid cell nests in the dermis underlying atypical melanocytic lesion. Along the dermoepidermal junction spindle-shaped atypical melanocytes with dermal invasion are observed as well as pagetoid spreading of cells with clear cytoplasm or of spindle cells upward the epidermis. Subtypes of this case is difficult to conclude, because this case shares both histopathologic characteristics of superficial spreading melanoma and those of acral lentiginous melanoma.
Cytoplasm
;
Dermis
;
Epidermis
;
Melanocytes
;
Melanoma*
;
Nevus, Pigmented*
6.Risk factors for severe postpartum hemorrhage requiring blood transfusion after cesarean delivery for twin pregnancy: a nationwide cohort study
Gi Hyeon SEO ; Jong Yeop KIM ; Da yeong LEE ; Changjin LEE ; Jiyoung LEE
Anesthesia and Pain Medicine 2023;18(4):367-375
Postpartum hemorrhage (PPH) is a leading cause of maternal morbidity and mortality. Twin pregnancy and cesarean delivery are well-known risk factors for PPH. However, few studies have investigated PPH risk factors in mothers who have undergone cesarean delivery for twin pregnancies. Therefore, this study investigated the risk factors associated with severe PPH after cesarean delivery for twin pregnancies. Methods: We searched and reviewed the Korean Health Insurance Review and Assessment Service’s claims data from July 2008 to June 2021 using the code corresponding to cesarean delivery for twin pregnancy. Severe PPH was defined as hemorrhage requiring red blood cell (RBC) transfusion during the peripartum period. The risk factors associated with severe PPH were identified among the procedure and diagnosis code variables and analyzed using univariate and multivariate logistic regressions. Results: We analyzed 31,074 cesarean deliveries for twin pregnancies, and 4,892 patients who underwent cesarean deliveries for twin pregnancies and received RBC transfusions for severe PPH were included. According to the multivariate analysis, placental disorders (odds ratio, 4.50; 95% confidence interval, 4.09– 4.95; P < 0.001), general anesthesia (2.33, 2.18–2.49; P < 0.001), preeclampsia (2.20, 1.99–2.43; P < 0.001), hemolysis, elevated liver enzymes, low platelets (HELLP) syndrome (2.12, 1.22–3.68; P = 0.008), induction failure (1.37, 1.07–1.76; P = 0.014), and hypertension (1.31, 1.18–1.44; P < 0.001) predicted severe PPH. Conclusions: Placental disorders, hypertensive disorders such as preeclampsia and HELLP syndrome, and induction failure increased the risk of severe PPH after cesarean delivery for twin pregnancy
7.Implantable Contact Lens to Correct High Myopia(Clinical Study with 24 Months Follow-up).
Sang Yeop LEE ; Hee Jong CHEON ; Tae Min BAEK ; Kyung Hun LEE
Journal of the Korean Ophthalmological Society 2000;41(7):1515-1522
A ICL TM(STAAR Collamer Posterior chamber Implantable Contact Lens) lents ranging from -11D to -21.3D. And then we investigated the visualwas implanted in 12 eyes of 7 patients with preoperative spherical equivalents ranging from -11 D to -21.3 D. And then we investigated the visual acuity, mean endothelial cell loss, change of refractive error and postoperative complications.Average follow-up was 28.1 months. In the immediate postoperative days, all eyes had a significant increase in uncorrected visual acuity and the best corrected visual acuity was improved in 7 eyes(58.3%). Mean percent difference between preoperative and postoperative endothelial cell count was 3.22+/-0.05% . The mean preoperative spherical equivalent refraction was -15.65+/-2.78 D. At a mean follow-up of 1 month, mean spherical equivalent refraction was -1.67+/-0.72D, at a 6months, 12 months, 24 months, mean spherical equivalent refraction was each -1.56+/-0.72D, -1.63+/-0.68D, -1.73+/-0.76D. During follow-up days one eye developed an faint anterior subcapsular cataract but the patient remained symptom free. Other reported complication was transient increased intraocular pressure. Although the follow-up in our study was limited cases(12 eyes), from our experience, the posterior chamber implantable contact lens was efficacious and safe in the correction of high myopic refraction errors.
Cataract
;
Endothelial Cells
;
Follow-Up Studies
;
Humans
;
Intraocular Pressure
;
Lenses, Intraocular*
;
Refractive Errors
;
Refractive Surgical Procedures
;
Visual Acuity
8.Variation in Patient Days and Medical Care Benefits Among Finger-Amputated Industrial Injuries.
Jong Ho LEE ; Sin KAM ; Keon Yeop KIM ; Young Sook LEE ; Yune Sik KANG ; Young Ae HA ; Ji Yeon SON ; Soon Woo PARK ; Jong Young LEE
Korean Journal of Occupational and Environmental Medicine 1997;9(3):439-451
No abstract available.
Humans
9.Impact of priming the infusion system on the performance of target-controlled infusion of remifentanil.
Jong Yeop KIM ; Bong Ki MOON ; Jong Hyuk LEE ; Youn Yi JO ; Sang Kee MIN
Korean Journal of Anesthesiology 2013;64(5):407-413
BACKGROUND: The start-up behavior of syringe and syringe pump is known to be one of the causes of inaccurate intravenous infusion. This study evaluated the method of priming the infusion system (PRIMING), and its impact on the target-controlled infusion (TCI) of two remifentanil diluents. METHODS: PRIMING was performed using an evacuation of 2.0 ml to the atmosphere prior to TCI. Forty-eight TCI, using 50 microg/ml (Remi50) or 20 microg/ml (Remi20) of diluents, were performed targeting 4.0 ng/ml of effect-site concentration (Ceff), with PRIMING or not. The gravimetrical measurements of the delivered infusates reproduced actual Ceff. The bolus amount and time to reach 95% target were compared. RESULTS: Without PRIMING, Remi50 infused less bolus (43 +/- 23 %) than Remi20 (19 +/- 9 %) (P = 0.003), and showed more delayed increase of Ceff (11.2 +/- 4.0 min) than Remi20 (7.4 +/- 0.4 min) (P = 0.028). However, PRIMING significantly decreased the deficit of the bolus (2 +/- 1%), as well as the delay of the increase of Ceff in Remi50 (1.2 +/- 0.2 min) (both P < 0.001). In addition, with PRIMING, the start-up bolus showed minimal difference to the nominal bolus (1 and 2%), and Ceff were increased to 4.0 +/- 0.1 ng/ml at the expected time of peak effect, irrespective of the diluents. CONCLUSIONS: Proper operation of the syringe pump used in the priming of the syringe may be helpful in reduction of the inaccuracy of TCI, particularly during the early phase of infusion, or the infusion of a more concentrated diluent.
Atmosphere
;
Infusions, Intravenous
;
Piperidines
;
Syringes
10.Two Cases of Neonatal Lupus Erythematosus.
In Ho KWON ; Jong Yeop YOO ; Jong Hee LEE ; Kwang Hyun CHO
Korean Journal of Dermatology 2003;41(7):956-959
Neonatal lupus erytematosus is characterized by cutaneous findings showing the morphology of subacute cutaneous lupus erythematosus, congenital heart block, and anti-Ro/SSA and/or anti-La/SSB autoantibodies which result from the transplacental passage of maternal autoantibodies. We report two cases of a 25-day-old female infant and a 30-day-old male infant who presented with characteristic clinical features of cutaneous neonatal lupus erythematosus but without evidence of congenital heart block. The serological studies in both infants revealed the presence of anti-SSA/Ro antibodies and antinuclear antibodies. We diagnosed their mothers as systemic lupus erythematosus with the clinical and laboratory findings.
Antibodies
;
Antibodies, Antinuclear
;
Autoantibodies
;
Female
;
Heart Block
;
Humans
;
Infant
;
Lupus Erythematosus, Cutaneous
;
Lupus Erythematosus, Systemic
;
Male
;
Mothers