1.No title available in English.
Jung Soo PARK ; Woong Yoon JEONG ; Jong Ho YOON ; Jong Joo JEONG ; Eun Kyung KIM
Korean Journal of Endocrine Surgery 2003;3(1):69-73
No abstract available.
2.A clinical study of thyroglossal duct cyst and fistula.
Sung Tak JEONG ; Jong Soo JOO ; Sang Hyo KIM
Journal of the Korean Surgical Society 1992;42(6):748-754
No abstract available.
Fistula*
;
Thyroglossal Cyst*
3.Diagnostic Value of Immediate CT after Chemoembolization in Patients with Hepatocellular Carcinoma: Comparison with 2-3 Week Delayed CT.
Yong Hoon KIM ; Jong Hoon KIM ; Soon Joo CHA ; Gham HUR ; Myeong Seok JEONG ; Jeong Joo WOO ; Jeong Wook SEO ; Jeong Hyeok KIM
Journal of the Korean Radiological Society 1995;33(2):247-251
PURPOSE: Lipiodol CT is a important modality for the diagnosis of hepatocellular carcinoma and compared is usually performed at 2-3 week after Lipiodol injection. Therefore, we assessed and the diagnostic value and merits of immediate CT after chemoembolization from there of 2-3 week delayed Lipiodol CT. MATERIALS AND METHODS: Thirty three cases of chemoembolization which were performed both immediate CT after chemoembolization and 2-3 week delayed Lipiodol CT were reviewed retrospectively. They were divided into four grades according to pattern of lipiodol uptake by three radiologists. The diagnostic value of immediate Lipiiodol CT was compared to delayed Lipiodol CT. RESULTS: Grade 0 was two cases(3.0%) and Grade 1 was seven cases(21.2%). In the cases of Grade 2(23/33, 69.7%) tumor uptake could be dishng wished from parenchymal uptake of Lipiodol by its density and pattern. Tumor uptake showed dense and homogeneous pattern, but parenchymal uptake revealed less dense and hepatoram-like wedge shaped pattern. Lipiodol uptake of tumor in Grade 3(1/24, 3.0%) was equal to that in delayed Lipiodrl CT. Grade 3 and 2(72.7%) of the immediate Lipiodol CT were not inferior to delayed Lipiodol CT in its diagnostic value. CONCLUSION: The immediate Lipiodol CT could make rapid establishment of treatment plan and are expected to be more convenient than delayed CT for the patients.
Carcinoma, Hepatocellular*
;
Diagnosis
;
Ethiodized Oil
;
Humans
;
Retrospective Studies
5.Therapeutic Effect of Cyclosporine a on Severe Henoch-Scholein Purpura Nephritis.
Pyung Kil KIM ; Ji Hong KIM ; Hyun Jong CHIN ; Hyeon Joo JEONG
Journal of the Korean Society of Pediatric Nephrology 1998;2(2):110-117
The fine needle aspiration (FNA) cytologic findings in 16 cases of histologically confirmed thymoma are reported. The aspirates were obtained under fluoroscopic guidance. The cytologic diagnoses were inadequate sample in one case, thymoma in 12 (75%), small cell carcinoma or thymoma in 1, benign mesenchymal tumor in 1, and germ cell tumor in one. The cytologic features were detailed according to the constituent epithelial cell type, and to the ratio of epithelial cells and lymphocytes. Fifteen cases were classified into 4 small epithelial cell type, 6 intermediate epithelial cell type, 1 large epithelial cell type, 1 large pleomorphic epithelial cell type, and 3 spindle-shaped epithelial cell type. Cytologic differential diagnosis was discussed, and the important criteria for the cytologic diagnosis of thymoma were reviewed. This review leads us to think that nonoperative cytologic approaches in the diagnosis of the thymoma are possible, and that correct cytologic diagnosis of thymoma with FNAs can easily be made, if adequate samples are obtained. However, the invasiveness and histologic type could not be predicted by cytological features only. Knowing various cytologic and histologic features of thymoma will be helpful for the diagnosis of thymoma and the differential diagnosis of mediastinal tumors.
Diagnosis, Differential
6.A Case of Alport's Syndrome.
Jung Bae LEE ; Jong Kyun LEE ; Pyung Kil KIM ; Hyeon Joo JEONG ; In Jun CHOI
Journal of the Korean Pediatric Society 1987;30(9):1040-1048
No abstract available.
Nephritis, Hereditary*
8.Laboratory Evaluation of Cobas(R) Integra Automated Chemistry Analyzer.
Yong Wha LEE ; Gyu Young JEONG ; Eun Joo PARK ; Jong Won KIM
Korean Journal of Clinical Pathology 1997;17(5):735-742
BACKGROUND: The Cobas(R) Integra is a new automated chemistry analyzer with continuous and random-access features for routine chemistries, specific proteins, electrolytes, therapeutic drugs and drugs of abuse. The system maintains 68 test-specific reagent cassettes on board and have test principles of absorbance photometry, immunoturbidometry, fluorescence polarization and ISE measurements. We evaluated the usefulness of Cobas(R) Integra in the aspect of accuracy, precision, linearity, comparison study, test speed and general performance. METHODS: We evaluated the analytical performance of the Cobas(R) Integra for T. bilirubin, CRP, BUN, creatinine, sodium, potassium, chloride, valproic acid, phenytoin and carbamazepine according to NCCLS guidelines (EP5-T2, EP6-P, EP9-T and GP10-T). RESULTS: In accuracy study, error ranges(%) of most test items, except sodium and chloride, were within analytic goals. In within-run and between-run precision study, Coefficient of variation (CV, %) of most items, except sodium, were lower than limits suggested by College of American Pathologists Survey 1991. The linearities were maintained well in the range of medically significant levels and were statistically acceptable (p<0.001). The comparison study for most items, except sodium and chloride, indicated good correlation with Hitachi 747 and TDx FLx(TM) and correlation coefficients (r) were above 0.98. Throughput was about 450 tests/hr. CONCLUSIONS: Cobas(R) Integra showed satisfactory accuracy, precision, linearity, good correlation with other analyzers and high throughput. So, we concluded that Cobas(R) integra is highly suitable for not only routine use but also emergency tests in medium to large-sized hospitals because of its high productivity and reliability.
Bilirubin
;
Carbamazepine
;
Chemistry*
;
Creatinine
;
Efficiency
;
Electrolytes
;
Emergencies
;
Fluorescence Polarization
;
Phenytoin
;
Photometry
;
Potassium
;
Sodium
;
Street Drugs
;
Valproic Acid
9.Laboratory Evaluation of Cobas(R) Integra Automated Chemistry Analyzer.
Yong Wha LEE ; Gyu Young JEONG ; Eun Joo PARK ; Jong Won KIM
Korean Journal of Clinical Pathology 1997;17(5):735-742
BACKGROUND: The Cobas(R) Integra is a new automated chemistry analyzer with continuous and random-access features for routine chemistries, specific proteins, electrolytes, therapeutic drugs and drugs of abuse. The system maintains 68 test-specific reagent cassettes on board and have test principles of absorbance photometry, immunoturbidometry, fluorescence polarization and ISE measurements. We evaluated the usefulness of Cobas(R) Integra in the aspect of accuracy, precision, linearity, comparison study, test speed and general performance. METHODS: We evaluated the analytical performance of the Cobas(R) Integra for T. bilirubin, CRP, BUN, creatinine, sodium, potassium, chloride, valproic acid, phenytoin and carbamazepine according to NCCLS guidelines (EP5-T2, EP6-P, EP9-T and GP10-T). RESULTS: In accuracy study, error ranges(%) of most test items, except sodium and chloride, were within analytic goals. In within-run and between-run precision study, Coefficient of variation (CV, %) of most items, except sodium, were lower than limits suggested by College of American Pathologists Survey 1991. The linearities were maintained well in the range of medically significant levels and were statistically acceptable (p<0.001). The comparison study for most items, except sodium and chloride, indicated good correlation with Hitachi 747 and TDx FLx(TM) and correlation coefficients (r) were above 0.98. Throughput was about 450 tests/hr. CONCLUSIONS: Cobas(R) Integra showed satisfactory accuracy, precision, linearity, good correlation with other analyzers and high throughput. So, we concluded that Cobas(R) integra is highly suitable for not only routine use but also emergency tests in medium to large-sized hospitals because of its high productivity and reliability.
Bilirubin
;
Carbamazepine
;
Chemistry*
;
Creatinine
;
Efficiency
;
Electrolytes
;
Emergencies
;
Fluorescence Polarization
;
Phenytoin
;
Photometry
;
Potassium
;
Sodium
;
Street Drugs
;
Valproic Acid
10.Cystic Lymphangioma of Breast: A Case Report.
Jong Koo LEE ; Eun Joo YUN ; Hyun Ja SHIN ; Jeong Rye KIM
Journal of the Korean Radiological Society 1995;32(2):347-349
Cystic lymphangioma are rare benign tumors that originate as a congenital anomaly of the lymphatic system. Their common presentation is in neck and axillary area at the birth, during infancy or early pediatric age group. Author reports an unusual case of cystic lymphangioma of breast which was diagnosed in a 32-year-old woman. The findings were very dense, sharply defined, and multilobulated masses on mammography, and mu-Itiloculated echo free lesions on ultrasonogram.
Adult
;
Breast*
;
Female
;
Humans
;
Lymphangioma, Cystic*
;
Lymphatic System
;
Mammography
;
Neck
;
Parturition
;
Ultrasonography