1.A Case of Congenital Diverticulum of Ventricle Associated with Pulmonary Atresia.
Kun Taek KIM ; Jo Won JUNG ; Jong Kyun LEE ; Jun Hee SUL ; Sung Kyu LEE
Journal of the Korean Pediatric Society 1994;37(2):276-281
The congenital diverticulum of ventricle is a rare cardiac malformation arising from the left or right ventricle, the former being more common. Ventricular diverticulum is usually associated with other anomalies including intracardiac, midline thoracic, diaphragmatic and abdominal wall defect. The authors experienced a case of congenital diverticulum of left ventricle in nine month-old female infant. Left Blolock-Taussig shunt operation was done and total correction will be done later. Thereafter we presented a case with brief review of the related literatures.
Abdominal Wall
;
Diverticulum*
;
Female
;
Heart Ventricles
;
Humans
;
Infant
;
Pulmonary Atresia*
2.A Case of Acute Lymphocytic leukemia in a Newborn.
Young Jin MIN ; Myoung Hee CHA ; Kyeng Sook CHO ; Jong Dai JO
Journal of the Korean Pediatric Society 1988;31(9):1197-1201
No abstract available.
Humans
;
Infant, Newborn*
;
Precursor Cell Lymphoblastic Leukemia-Lymphoma*
3.Bilateral Coronary Artery-Right Ventricular Fistula in Newborn: Associated with Atrial Septal Defect.
Jo Won JUNG ; Jong Kyun LEE ; Jun Hee SUL ; Sung Kyu LEE ; Dong Gwan HAN
Korean Circulation Journal 1991;21(6):1259-1264
Bilateral coronary artery fistula is very uncommon congenital anomaly which occupy small percentage of all congenital coronary artery fistula. About 20% of the cases associated with additional congenital heart disease. And it may cause congestive heart failure, especially severely in neonate. We experienced a case of neonate who was 1 day-old-male with bilateral coronary artery-right ventricular fistula associated with atrial septal defect and congestive heart failure. The Patient was admitted because dyspnea, cyanosis since birth. 2D ecgicardiogram and cardiac catheterization revealed that a fistulous communicating ; forming a large aneurysm, was noted from bilateral coronary artery emptied into the right ventricle, and there was oxygen step-up in right ventricle.
Aneurysm
;
Cardiac Catheterization
;
Cardiac Catheters
;
Coronary Vessels
;
Cyanosis
;
Dyspnea
;
Fistula*
;
Heart Defects, Congenital
;
Heart Failure
;
Heart Septal Defects, Atrial*
;
Heart Ventricles
;
Humans
;
Infant, Newborn*
;
Oxygen
;
Parturition
4.Analysis of the morphological characteristics of double outlet right ventricle and comparative study of operative methods.
Jun Hee SUL ; Jong Kyun LEE ; Jo Won JUNG ; Sung Kyu LEE ; Bum Koo CHO
Journal of the Korean Pediatric Society 1993;36(12):1721-1731
Double outlet right ventricle, a complex of congenital cardiac anomalies in which both great arteries arise wholly or in large part from the morphologic right ventricle presents diverse clinical manifestations according to the morphological characteristics. Eighty cases with DORV were diagnosed and operated at Yonsei Cardiovascular Center from 1988 to 1992. The analysis of the morphological characteristics of this anomaly and comparative study of operative methods and mortality according to the morphological classification led to the following results: 1) The location of VSD varied to be subaortic in 40 cases, subpulmonic in 15, doubly committed in 6 and noncommitted in 19 cases. The great arteries were interrelated in D-malposition in 43 cases and L-malposition in 18 and 26 cases among above mentioned 61 cases revealed the side-by-side relationship. Ten of the cases showed normal position and the rest 9, A-malposition. 2) Pulmonary stenosis was found in 60 cases, and when associated with subpulmonic VSD, occurring less frequently. PDA and ASD secundum were associated in successional order and only 3 cases were verified to carry aortic arch anomalies such as coarctation and interruption, all with subpulmonic VSD. 3) Intraventricular tunnel repair was possible in every case associated with subaortic VSD and the postoperative prognosis was excellent. In comparison, most of the cases associated with other types of VSD in which only palliative surgery or various types of intraventricular repair were performed, the general outcome was poor. But total cavopulmonary connection, one of the physiological corrective methods, showing a better postoperative prognosis is being carefully considered for its broad adoptation in future. In conclusion, double outlet right ventricle, a pathophysiological complex of various anomalies, should be thoroughly evaluated for the morphological characteristics to decide the most appropriate types of operation and for consequent improvement of prognosis.
Aorta, Thoracic
;
Arteries
;
Classification
;
Double Outlet Right Ventricle*
;
Heart Ventricles
;
Mortality
;
Palliative Care
;
Prognosis
;
Pulmonary Valve Stenosis
5.Bronchogenic cyst causing trachea & bronchus obstruction.
Hee Jae JUN ; Pill Jo CHOI ; Si Young HAM ; Si Chan SUNG ; Jong Su WOO
The Korean Journal of Thoracic and Cardiovascular Surgery 1992;25(10):1066-1069
No abstract available.
Bronchi*
;
Bronchogenic Cyst*
;
Trachea*
6.Syphilitio abdominal aortic aneurysm associated with deep vein thrombosis and pulmonary embolism.
Hee Jae JUN ; Pill Jo CHOI ; Si Young HAM ; Si Chan SUNG ; Jong Su WOO
The Korean Journal of Thoracic and Cardiovascular Surgery 1992;25(10):1141-1145
No abstract available.
Aortic Aneurysm, Abdominal*
;
Pulmonary Embolism*
;
Venous Thrombosis*
7.Two Cases of Non-Surgical Removal of Intravascular Foreign Bodies.
Jean Man HUR ; Jong Il JEON ; Kyoung Geun JO ; Jae Woong CHOI ; Chan Hee MOON
Korean Circulation Journal 1997;27(9):922-926
One of the complication during or after subclavian vein cannulation is intravascular catheter or wire embolization. Although some studies have reported safety of retaining foreign body embolization, and even death. The intravascular foreign body can be removed surgically or non-surgically. With improvement in instrument technology and technique, percutaneous retrieval of intravascular foreign bodies has become a relatively common procedure. Commonly used methods to remove intravascular foreign bodies are loop snare and basket technique. Sometimes biopy forcep can be used. We have experienced 2 cases of non-surgical removal of intravascular foreign bodies. One of the foreign bodies was 7cm wire fragment in right atrium(RA), the other was a 50cm guide wire. We used the standard loop snare technique for removal of 7cm wire fragment in RA and stone removal basket and 3.0mm ACS PTCA balloon to remove the 50cm short guide wire.
Catheterization
;
Catheters
;
Foreign Bodies*
;
SNARE Proteins
;
Subclavian Vein
;
Surgical Instruments
8.Analysis of the Factors That Influence on the Effect of Prostaglandin E1(PGE1)in Infants with Ductus-Dependent Cyanotic Congenital Heart Disease.
Jong Kyun LEE ; Seok Min CHOI ; Jo Won JUNG ; Jun Hee SUL ; Sung Kyu LEE
Korean Circulation Journal 1994;24(6):841-847
BACKGROUND: The prostaglandin E1(PGE1) is a well known protent dilator of arteriosus. Maintaining of the patency of ductus arteriosus is crucial for the survival of patients suffering from ductus-dependent cyanotic congenital heart disease. We aimed to analyse the efficacy and the influencing factors upon PGE1 in patients suffering from this disease. METHODS: Between May 1991 and April 1993, 26 neonates and infants with ductus- dependent cyanotic congenital heart disease received on intravenous infusion of PGE1 in the Division of Pediatric Cardiology. Yonsei Cardiovascular Center. The result was a dramatic improvement in systemic arterial oxygen tension and oxygen saturation during infusion of PGE1with a dependency on the infusion of PGE1. We evaluated the arterial blood gas analysis both at the immediate pre-infusion stage and 2 hours after infusion. We aimed to analyse the factors which may influence the intravenous of PGE1to infant suffers of ducts-dependent cyanotic congenital heart disease, such as pulmonary atresia(n=14), severe pulmonary stenosis(n=7) or complete transposition of the great arteries(n=5). RESULTS: 1) There was a significant increase in PaO2 and Oxygen saturation 2 hours after the infusion of PGE1. This appeared to be unrelated to the different forms of the disease when compared with the pre-infusion values. 2) The infants' responsiveness of the ductus arteriosus appeared to be age related with significant differences emerging between the 2 group(p<.05). In infants younger than 9 hours old, the differences in PaO2 changes between pre-infusion and post-infusion of PGE1 were 16.3+/-3.7mmHg compared to just 10.4+/-0.4mmHg in infants older than 96 hours. 3) No significant difference emerged between an increase in PaO2or oxygen saturation relating to the shape of ductus arteriosus ; or the level of PaO2prior to the infusion. 4) The side effects of PGE1were as follows ; fever(84.6%),loose stool(61.5%), apnea(30.8%) and hypotension(15.4%), etc.. CONCLUSION: PGE1provides excellent medical palliation for infants suffering from ductus-dependent cyanotic congenital heart disease until the pulmonary arteries are large enough for a modified Blalock-Taussig shunt ; or until corrective surgery is possible.
Alprostadil
;
Blalock-Taussig Procedure
;
Blood Gas Analysis
;
Cardiology
;
Ductus Arteriosus
;
Heart Defects, Congenital*
;
Humans
;
Infant*
;
Infant, Newborn
;
Infusions, Intravenous
;
Oxygen
;
Pulmonary Artery
9.A Case of Two Giant Congenital Aneurysms of the Right Coronary Artery.
Yong Kwan KIM ; Jo Won CHUNG ; Jong Kyun LEE ; Jun Hee SUL ; Sung Kyu LEE
Journal of the Korean Pediatric Society 1994;37(6):850-853
Aneurysms of the coronary arteries are rare. They may be due to atheroselerosis, mucocutaneous lymph node syndrome, mycotic emboli, syphilis or trauma and occasionally they are congenital. The prognosis appears to be poor and death can occur suddenly from rupture of the aneurysm, peripheral coronary embolism or bacterial endocarditis. Recently surgical treatment has been successful. In a 5 year old patient with ventricular septal defect, two aneurysmal sacs located at the cardiac crux and just posterior to it was proved by coronary angiography and MRI, and successfully excised at operation.
Aneurysm*
;
Child, Preschool
;
Coronary Angiography
;
Coronary Vessels*
;
Embolism
;
Endocarditis, Bacterial
;
Heart Septal Defects, Ventricular
;
Humans
;
Magnetic Resonance Imaging
;
Mucocutaneous Lymph Node Syndrome
;
Prognosis
;
Rupture
;
Syphilis
10.Biomechanical Study about Difference between Stainless Steel and Titanium Dynamic Hip Screws in Peritrochanteric Fractures of the Femur.
Kwang Suk LEE ; In Hee LEE ; Kyung Jo WOO ; Jong Hoon PARK ; Dae Gon WIE
The Journal of the Korean Orthopaedic Association 1997;32(4):929-936
Peritrochanteric fractures are common in the elderly, and the mortaliy and morbidity rates after conservative treatment of the fractures are usually high. In these fractures the internal fixation now allows the patient more rapid functional gain. It has been known that for stabilization of fracture the sliding hip screw is superior to other fixation devices. To investigate the biomechanical difference between two different materials of dynamic hip screw, eight intertrochateric and eight subtrochanteric femur fractures were artificially induced in human cadavers. Two femurs were used as the control. In eight cadaver intertrochanteric fractures (Group I), four of them were treated with stainless steel compression hip screw and four were treated with titanium compression hip screw. Eight cadaver subtrochanteric fractures (Group II) were divided by two groups as equal number. One group was treated with stainless steel compression hip screw and the other was treated with titanium compression hip screw with plate. Each femur was secured in a fixation device of the Instron and loaded in a vertical compression. Collapse or fixation failure during vertical compression were observed and recorded continuously in slow speed with deformation rate of 3mm/min. Biomechanical analysis of maximal loading force in the control and experimental two groups were performed. The results were as follows; 1. The mean maximal loading force was 625 kp in control group. 2. The mean maximal loading force in each 4 intertrochanteric fractures fixed with stainless steel DHS (dynamic hip screw) and plate was 92.59 kp, and with titanium DHS and plate was 71.57 kp. There was no statistical significance between stainless steel DHS and plate fixation and titanium DHS and plate fixation. (p>0.05) 3. The mean maximal loading force in each 4 subtrochanteric fractures fixed with stainless DHS and plate was 140.12 kp, and with titanium DHS with plate was 169.4 kp. There was no statistical significance between stainless steel DHS and plate fixation and titanium DHS and plate fixation. (p>0.05) 4. The breakage of metal implant was not occurred at the maximal loading force 600 kp in both group. There was no difference of fixability and stability according to the metal quality, as the results of the experiment of compression loading force to the stainless steel DHS and titanium DHS fixation on intertrochanteric and subtrochanteric fractures in cadaverous femurs.
Aged
;
Cadaver
;
Femur*
;
Hip Fractures
;
Hip*
;
Humans
;
Internal Fixators
;
Stainless Steel*
;
Titanium*