1.Three-dimensional finite element analysis of the cantilever fixed bridge supported by implants with different shapes
zheng Jun WANG ; bo Qi WANG ; Chao DING ; hui Jiu SHI
Chinese Journal of Tissue Engineering Research 2017;21(30):4830-4835
BACKGROUND: The shape of the implant exerts an effect on its biomechanics. At present, the research of implant-supported fixed partial denture with cantilever extension mainly focuses on the same shape, and little is reported on the comparison and analysis of implant-supported fixed partial denture with cantilever extension supported by different shape implants.OBJECTIVE: To compare the biomechanical behaviors of cantilever fixed bridges which were supported by three different implants, including cylindrical implant, tapered implant, expandable implant, in the mandibular posterior region with the help of three-dimensional finite element analysis. METHODS: The three-dimensional finite element models of the cantilever fixed bridges which were supported by cylindrical implant, tapered implant and expandable implant and their surrounding tissue in the mandibular posterior region were established were established. The force of 300 N was applied to the cantilever fixed bridges with axial 90° and buccolingual 45° to evaluate the maximum von Mises stress (Max EQV stress) of cortical bone and cancellous bone and the maximum displacement in implant-abutment complex.RESULTS AND CONCLUSION: Under axial and buccolingual loads, the Max EQV stress in the cortical bone was higher than that in the cancellous bone. The cantilever fixed bridge which was supported by expandable implant had the lowest Max EQV stress in the cortical bone, especially under axial load, and exhibited the highest Max EQV stress in the cancellous bone. The cantilever fixed bridges supported by three different implants showed an increase in the Max EQV stress of the cortical bone and cancellous bone and the maximum displacement in implant-abutment complex under buccolingual load. The cantilever fixed bridge which was supported by expandable implant had the minimum maximum displacement in the buccolingual direction. To conclude, the cantilever fixed bridge which is supported by expandable implant has best stability.
2.A20 inhibits human salivary adenoid cystic carcinoma cells invasion via blocking nuclear factor-kappaB activation.
Bin ZHANG ; Cheng-chao GUAN ; Wan-tao CHEN ; Ping ZHANG ; Ming YAN ; Jiu-hui SHI ; Chun-lin QIN ; Qian YANG
Chinese Medical Journal 2007;120(20):1830-1835
BACKGROUNDA20, also known as tumor necrosis factor alpha induced protein 3 (TNFaip3), is a cytoplasmic zinc finger protein that inhibits nuclear factor kappa-B (NF-kappaB) activity and prevents tumor necrosis factor (TNF)-mediated programmed cell death. NF-kappaB is a transcription factor that regulates expression of genes involved in cell proliferation, cell survival and anti-apoptosis. Several studies have implicated that the NF-kappaB signal pathway is associated with angiogenesis and clinico-pathological process of adenoid cystic carcinoma (ACC) of the salivary glands.
METHODSThe ability of overexpression of A20 to influence the biological behavior and invasion of ACC cells was examined. The cells were stably transfected with full-length A20 cDNA. Stable gene transfer was verified by realtime-polymerase chain reaction (PCR) and Western blot analysis. The change of cell biological behavior was examined by methyl thiazolyl tetrazolium (MTT) and NF-kappaB luciferase reporter assay and the invasion of the cells was examined by a Matrigel invasion chamber.
RESULTSpEGPFN3-A20 gene was stably transferred into ACC-2 cells and overexpressed. When cells were treated with TNFalpha, the NF-kappaB activity of ACC-2-A20 cells could be down-regulated about 46.32% in contrast to ACC-2-GFP cells (P < 0.05). A20 potently inhibited growth of A20 transfectant ACC-2-A20 compared with control vector transfected groups and the ACC-2 empty control group (P < 0.05). The ACC-2-A20 cells showed significantly reduced ability to invade through Matrigei-coated filters compared to ACC-2-GFP and ACC-2 cells. The inhibition rate was up to 71.05% (P < 0.05).
CONCLUSIONSA20 gene transfer is associated with decreased tumor invasion, in part via the down-regulation of NF-kappaB expression, providing evidence for a potential application of A20 in designing a treatment modality for salivary gland cancers such as ACC.
Carcinoma, Adenoid Cystic ; pathology ; therapy ; Cell Line, Tumor ; DNA-Binding Proteins ; Genetic Therapy ; Humans ; Intracellular Signaling Peptides and Proteins ; genetics ; NF-kappa B ; antagonists & inhibitors ; Neoplasm Invasiveness ; Nuclear Proteins ; genetics ; Salivary Gland Neoplasms ; pathology ; therapy ; Transfection ; Tumor Necrosis Factor alpha-Induced Protein 3
3.Efficacy and safety of Changfu peritoneal dialysis solution: a multi-center prospective randomized controlled trial.
Jian-Hui ZHOU ; Zhao-Hui NI ; Chang-Lin MEI ; Xue-Qing YU ; Fu-You LIU ; Li-Ning MIAO ; Zhi-Hong LIU ; Wei-Jie YUAN ; Ai-Ping ZHANG ; Hong-Li LIN ; Meng-Hua CHEN ; Jiang-Hua CHEN ; Jin-Yuan ZHANG ; Ya-Ni HE ; Jian CHEN ; Jiu-Yang ZHAO ; Xiao-Qiang DING ; Ying LI ; Rong-Shan LI ; Ru-Juan XIE ; Wen-Hu LIU ; Chang-Ying XING ; Rong WANG ; Yue-Yi DENG ; Xue-Ying CAO ; Guang-Yan CAI ; Shan MOU ; Zhi-Guo MAO ; Xiao YANG ; Hong LIU ; Jing SUN ; Yu-Sheng YU ; Jun LIU ; Shu-Mei SHI ; Long-Kai LI ; Na TIAN ; Xiao-Hui ZHANG ; Wei ZHOU ; Jie YANG ; Yong ZHANG ; Jing-di SUN ; Jun JI ; Tao ZHANG ; Yan YAN ; Xiao-Gang LIU ; Gang WANG ; Li ZHANG ; Hong ZHANG ; Jian-Hua LUO ; Xiang-Mei CHEN
Chinese Medical Journal 2013;126(22):4204-4209
BACKGROUNDA multi-center large scale study is needed to confirm the efficacy and safety of domestic peritoneal dialysis (PD) solutions. Some researchers believe that 6 L/d is enough for adequate dialysis, but there is no multi-center prospective study on Chinese population to confirm this. In this study, we evaluated the efficacy and safety of domestic PD solution (Changfu) and its difference between 6 L and 8 L dosage.
METHODSAdult PD patients who had taken PD therapy for at least one month were selected and divided into four groups according to two dialysis solution brands and two dialysis dosages, i.e., 6 L dose with Changfu dialysis solution, 6 L dose with Baxter dialysis solution, 8 L dose with Changfu dialysis solution, and 8 L dose with Baxter dialysis solution. After 48 weeks, the changes of primary and secondary efficacy indices were compared between different types and different dosages. We also analyzed the changes of safety indices.
RESULTSChanges of Kt/V from baseline to 48 weeks between Changfu and Baxter showed no statistical differences; so did those of creatinine clearance rate (Ccr). Normalized protein catabolic rate (nPCR) from baseline to 48 weeks between Changfu and Baxter showed no statistical differences; so did those of net ultrafiltration volume (nUF) and estimated glomerular filtration rate (eGFR). Changes of nPCR from baseline to 48 weeks between 6 L and 8 L showed no statistical differences; so did those of nUF and eGFR. The decline of Kt/V from baseline to 48 weeks in 6 L group was more than that in 8 L group. Change of Ccr was similar. During the 48-week period, the mean Kt/V was above 1.7/w, and mean Ccr was above 50 L×1.73 m(-2)×w(-1). More adverse events were found in Changfu group before Changfu Corporation commenced technology optimization, and the statistical differences disappeared after that.
CONCLUSIONSThe domestic PD solution (Changfu) was proven to be as effective as Baxter dialysis solution. During 48-week period, a dosage of 6 L/d was enough for these patients to reach adequate PD. Clinical study promotes technological optimization, further helps to improve the safety indices of the medical products.
Adolescent ; Adult ; Aged ; Dialysis Solutions ; therapeutic use ; Female ; Humans ; Male ; Middle Aged ; Peritoneal Dialysis ; methods ; Young Adult
4.Quantitative Expression of RNA from Frozen Organs and Formaldehyde-fixed and Paraffin-embedded Tissues.
Ye Hui LÜ ; Shi Ying LI ; Zhi Hong LI ; Rui Yang TAO ; Yu SHAO ; Qian HU ; Zhi Fang YANG ; Yi Jiu CHEN
Journal of Forensic Medicine 2019;35(4):387-392
Objective Quantitative analysis and comparison of the expression of ribonucleic acid (RNA) from frozen organs and formaldehyde-fixed and paraffin-embedded (FFPE) tissues. Methods Frozen specimens of human brain, myocardium and liver tissues as well as FFPE samples at different postmortem intervals were collected and mass concentration of RNA was extracted and detected. Reverse transcription-quantitative polymerase chain reaction (RT-qPCR) technology was used to analyze the amplification efficiency and relative expression of each RNA marker. Results The mass concentration and integrity of RNA extracted from FFPE samples were relatively low compared with frozen specimens. The amplification efficiency of RNA markers was related with RNA species and the length of amplification products. Among them, glyceraldehyde-3-phosphate dehydrogenase (GAPDH) and β-actin (ACTB) with relatively long amplification products failed to achieve optimal amplification efficiency, whereas 5S ribosomal RNA (5S rRNA) achieved ideal amplification efficiency and showed quite stable expression across various tissues, therefore it was chosen as internal reference marker. The expression quantity of GAPDH and ACTB in frozen specimens with longer postmortem intervals and in FFPE samples with relatively long amplification products was decreased. The expressions of tissue-specific microRNAs (miRNAs), GAPDH and ACTB with relatively short amplification products had consistency in the same tissues and FFPE samples. Conclusion Through standardizing the RT-qPCR experiment, selecting the appropriate RNA marker and designing primers of appropriate product length, RNA expression levels of FFPE samples can be accurately quantified.
DNA Primers
;
Formaldehyde
;
Gene Expression Profiling
;
Humans
;
MicroRNAs/analysis*
;
Myocardium
;
Paraffin Embedding
;
RNA/analysis*
;
Real-Time Polymerase Chain Reaction/standards*
5.Prevalence, awareness, treatment, and control of hypertension in the non-dialysis chronic kidney disease patients.
Ying ZHENG ; Guang-Yan CAI ; Xiang-Mei CHEN ; Ping FU ; Jiang-Hua CHEN ; Xiao-Qiang DING ; Xue-Qing YU ; Hong-Li LIN ; Jian LIU ; Ru-Juan XIE ; Li-Ning WANG ; Zhao-Hui NI ; Fu-You LIU ; Ai-Ping YIN ; Chang-Ying XING ; Li WANG ; Wei SHI ; Jian-She LIU ; Ya-Ni HE ; Guo-Hua DING ; Wen-Ge LI ; Guang-Li WU ; Li-Ning MIAO ; Nan CHEN ; Zhen SU ; Chang-Lin MEI ; Jiu-Yang ZHAO ; Yong GU ; Yun-Kai BAI ; Hui-Min LUO ; Shan LIN ; Meng-Hua CHEN ; Li GONG ; Yi-Bin YANG ; Xiao-Ping YANG ; Ying LI ; Jian-Xin WAN ; Nian-Song WANG ; Hai-Ying LI ; Chun-Sheng XI ; Li HAO ; Yan XU ; Jing-Ai FANG ; Bi-Cheng LIU ; Rong-Shan LI ; Rong WANG ; Jing-Hong ZHANG ; Jian-Qin WANG ; Tan-Qi LOU ; Feng-Min SHAO ; Feng MEI ; Zhi-Hong LIU ; Wei-Jie YUAN ; Shi-Ren SUN ; Ling ZHANG ; Chun-Hua ZHOU ; Qin-Kai CHEN ; Shun-Lian JIA ; Zhi-Feng GONG ; Guang-Ju GUAN ; Tian XIA ; Liang-Bao ZHONG ; null
Chinese Medical Journal 2013;126(12):2276-2280
BACKGROUNDData on the epidemiology of hypertension in Chinese non-dialysis chronic kidney disease (CKD) patients are limited. The aim of the present study was to investigate the prevalence, awareness, treatment, and control of hypertension in the non-dialysis CKD patients through a nationwide, multicenter study in China.
METHODSThe survey was performed in 61 tertiary hospitals in 31 provinces, municipalities, and autonomous regions in China (except Hong Kong, Macao, and Taiwan). Trained physicians collected demographic and clinical data and measured blood pressure (BP) using a standardized protocol. Hypertension was defined as systolic BP ≥ 140 mmHg and/or diastolic BP ≥ 90 mmHg, and/or use of antihypertensive medications. BP < 140/90 mmHg and < 130/80 mmHg were used as the 2 thresholds of hypertension control. In multivariate logistic regression with adjustment for sex and age, we analyzed the association between CKD stages and uncontrolled hypertension in non-dialysis CKD patients.
RESULTSThe analysis included 8927 non-dialysis CKD patients. The prevalence, awareness, and treatment of hypertension in non-dialysis CKD patients were 67.3%, 85.8%, and 81.0%, respectively. Of hypertensive CKD patients, 33.1% and 14.1% had controlled BP to < 140/90 mmHg and < 130/80 mmHg, respectively. With successive CKD stages, the prevalence of hypertension in non-dialysis CKD patients increased, but the control of hypertension decreased (P < 0.001). When the threshold of BP < 130/80 mmHg was considered, the risk of uncontrolled hypertension in CKD 2, 3a, 3b, 4, and 5 stages increased 1.3, 1.4, 1.4, 2.5, and 4.0 times compared with CKD 1 stage, respectively (P < 0.05). Using the threshold of < 140/90 mmHg, the risk of uncontrolled hypertension increased in advanced stages (P < 0.05).
CONCLUSIONSThe prevalence of hypertension Chinese non-dialysis CKD patients was high, and the hypertension control was suboptimal. With successive CKD stages, the risk of uncontrolled hypertension increased.
Adult ; Aged ; Awareness ; Female ; Humans ; Hypertension ; complications ; epidemiology ; therapy ; Male ; Middle Aged ; Prevalence ; Renal Insufficiency, Chronic ; complications
6.Safety, Effectiveness, and Manipulability of Peritoneal Dialysis Machines Made in China: A Randomized, Crossover, Multicenter Clinical Study.
Xue-Ying CAO ; Ya-Ni HE ; Jian-Hui ZHOU ; Shi-Ren SUN ; Li-Ning MIAO ; Wen CHEN ; Jing-Ai FANG ; Ming WANG ; Nian-Song WANG ; Hong-Li LIN ; Jian LIU ; Zhao-Hui NI ; Wen-Hu LIU ; Yu NA ; Jiu-Yang ZHAO ; Zhi-Yong GUO ; Hong-Guang ZHENG ; Wei SHI ; Geng-Ru JIANG ; Guang-Yan CAI ; Xiang-Mei CHEN
Chinese Medical Journal 2018;131(23):2785-2791
Background:
Automated peritoneal dialysis (APD) can cater to individual needs, provide treatment while asleep, take into account the adequacy of dialysis, and improve the quality of life. Currently, independent research and development of APD machines made in China are more conducive to patients. A randomized, multicenter, crossover study was conducted by comparing an APD machine made in China with an imported machine. The safety, effectiveness, and manipulability of the two machines were compared.
Methods:
Two hundred and sixty patients who underwent peritoneal dialysis (PD) on a regular basis in 18 centers between August 2015 and February 2016 were included. The inclusion criteria include age ≥18 years and PD ≥30 days. The exclusion criteria were as follows: hemodialysis; exit site or tunnel infection; and peritonitis ≤30 days. The patients were randomly divided into Group A, who were first treated with a FM machine made in China, then changed to an imported machine; and Group B, who were treated using the reverse sequence. APD treatment was performed with 10 L/10 h and 5 cycles of exchange. After 72 h, the daily peritoneal Kt/V, the accuracy of the injection rate, accuracy of the injection temperature, safety, and manipulability of the machine were assessed. Noninferiority test was conducted between the two groups.
Results:
The daily peritoneal Kt/V in the APD machine made in China and the imported APD machine were 0.17 (0.14, 0.25) and 0.16 (0.13, 0.23), respectively. There was no significant difference between the groups (Z = 0.15, P = 0.703). The lower limit of the daily Kt/V difference between the two groups was 0.0069, which was greater than the noninferiority value of -0.07 in this study. The accuracy of the injection rate and injection temperature was 89.7% and 91.5%, respectively, in the domestic APD machine, which were both slightly better than the accuracy rates of 84.0% and 86.8% in the imported APD machine (89.7% vs. 84.0%, P = 0.2466; 91.5% vs. 86.8%, P = 0.0954). Therefore, the APD machine made in China was not inferior to the imported APD machine. The fuselage of the imported APD machine was space-saving, while the APD machine made in China was superior with respect to body mobility, man-machine dialog operation, alarm control, and patient information recognition.
Conclusions:
The FM machine made in China was not inferior to the imported APD machine. In addition, the FM machine made in China had better operability.
Trial Registration
Clinicaltrials.gov, NCT02525497; https://clinicaltrials.gov/ct2/results?cond=&term=NCT02525497&cntry=& state=&city=&dist=.
Adult
;
China
;
Cross-Over Studies
;
Female
;
Humans
;
Male
;
Middle Aged
;
Multicenter Studies as Topic
;
Peritoneal Dialysis
;
adverse effects
;
instrumentation
;
methods
;
Quality of Life
;
Temperature