1.Relationship Between Renin-angiotensin-aldosterone System and Syndrome Patterns in Patients with Ventricular Remodeling Following Myocardial Infarction
Journal of Guangzhou University of Traditional Chinese Medicine 1999;0(02):-
【Objective】To investigate the relationship of plasma renin activity(PRA),angiotensin Ⅱ(Ang Ⅱ) and aldosterone(ALD) activities with syndrome patterns in patients with ventricular remodeling following myocardial infarction,and to supply neuroendocrine evidence for syndrome differentiation of ventricular remodeling following myocardial infarction.【Methods】Sixty patients with ventricular remodeling following myocardial infarction were classified as Qi stagnation and blood stasis(pattern 1,n=16),phlegm-turbidity blockage(pattern 2,n=15),yangQi deficiency(pattern 3,n=16) and yin-blood deficiency(pattern 4,n=13).Radioimmunoassay(RIA) was used to measure plasma renin,Ang Ⅱ and ALD levels in acute myocardial infarction patients 7 days after onset,and cardiac color ultrasound was used to examine left ventricular function.【Results】In patients with ventricular remodeling following myocardial infarction,left ventricular end diastolic diameter(LVEDD),left ventricular end diastolic volume(LVEDV),left ventricular end systolic volume(LVESV),and left ventricular ejection fraction(EF) increased as compared with those in the healthy.LVEDD,LVESV and LVEDV became larger in patients with pattern 3 and pattern 1 than those in patients with pattern 2 and pattern 4(P
2.Correction of upper eyelid depression by transposition of orbital septum fat.
Qingyang LIU ; Shuya PAN ; Da CHEN ; Qigang ZHU ; Yilan SONG ; Jiting QIU ; Xinwen GUO
Chinese Journal of Plastic Surgery 2015;31(2):100-102
OBJECTIVETo discuss the operation method and characteristic of correcting upper eyelid depression by transposition of orbital septum fat.
METHODSDuring the double eyelid surgery, we set.the lateral orbital septum fat completely free, while the bottom is still connected with the middle orbital septum fat. We separate a tunnel from the middle to the inner side in orbital septum, and the separated orbital septum fat is transposed to the inner side of orbital septum by the tunnel with suturing fixation.
RESULTSFrom March 2008 to October 2013, 51 cases with upper eyelid depression were treated successfully. Patients were followed up for 3 months to 3 years (average, 7. 5 months) with sustained aesthetic results.
CONCLUSIONSOrbital septum fat transposition can successfully correct the upper eyelid depression. It should become a regular procedure in blepharoplasty.
Adipose Tissue ; transplantation ; Blepharoplasty ; methods ; Esthetics ; Eyelids ; abnormalities ; surgery ; Humans ; Orbit
3.The value of ischemia-modified albumin in early diagnosis of acute myocardial infarction
Mingzheng XU ; Zhigang XI ; Guozhong YU ; Jifeng HE ; Quanyou LIU ; Jiting REN
Clinical Medicine of China 2011;27(10):1012-1014
Objective To investigate the value of ischemia modified albumin (IMA) detection in preliminary diagnosis of acute myocardial infarction (AMI).Methods The levels and variations of IMA,cTnI and CK-MB in 103 patients with acute chest pain were measured continuously at 0,4,6,12,24 hours after admission respectively.Thirty healthy subjects were observed as normal controls.Results Twenty three patients were diagnosed as AMI in the end,the sensitivity and specificity rates right after admission were 89.3% and91.3% for IMA,48.4% and 92.3% for CK-MB,30.6% and 93.7% for cTnI respectively.The sensitivity values at the 6th hours after admission were 91.3% for IMA,52.2% for CTnI and 34.8% for CK-MB respectively.The specificity was 100.0% when the IMA was detected in combination with CK-MB or cTnI.The sensitivity of co-detection was significantly higher than that any single detection at sixth hours after admission (x2 =15.99,P < 0.01 ).Conclusion Plasma IMA assessment is helpful for early diagnosis of AMI,and will significantly improve the sensitivity early diagnosis of AMI.The co-detection of IMA and CK-MB or cTnI obviously surpasses any single detection,and has extremely vital clinical significance.
4.Value of ischemia modified albumin detection method in the early diagnosis of acute coronary syndrome.
Mingzheng XU ; Zhigang XI ; Guozhong YU ; Jifeng HE ; Quanyou LIU ; Jiting REN
Clinical Medicine of China 2010;26(9):905-907
Objective To discuss the value of ischemia modified albumin (IMA) in the early diagnosis of acute coronary syndrome (ACS). Methods The IMA,cTnI, CK-MB and ECG were detected in 103 patients with suspected ACS (45 cases of NICP and 58 cases of ACS) within 5 hours of acute chest pain onset respectively. 30 healthy subjects were served as normal controls. Receiver operating characteristic (ROC) analysis was used to determine the optimal cutoff of this assay for identifying individuals with ACS from non-ischemic individuals (nonischemic chest pain, NICP). Results of IMA,cTnI,CK-MB and ECG were correlated with the final diagnosis and their diagnostic sensitivities for ACS were evaluated. Results The results suggested that acute phase IMA values between those with ACS and NICP were (89.66 ± 25.82) U/ml, (46.79 ± 17.20) U/ml respectively and showed significant difference. Area under the curve (AUC) of the ROC was 0.935. As the Cut-off point was 71.6 U/ml, the sensitivity, specificity, PPV and NPV of IMA were 90.6%, 71.4% , 82.8% and 83.3%, respectively. The simutanious positive rate of IMA for ischemia origin were 29.3% of cTnI,27.6% of CK-MB and 48.3% of ECG(P< 0.01). Conclusions Plasma IMA assessment is valuable for early diagnosis of acute coronary ischemia, and will improve the early diagnostic sensitivity of ACS significantly.
5.Long term exposure to low doses of sodium arsenite on effect of apoptosis in immortalized human skin cutin forming cells
Chunchun LI ; Hanyi DENG ; Yiping NI ; Yuan MA ; Jiting LIU ; Rui YAN ; Dapeng WANG ; Qingling WANG ; Jie ZHANG ; Yan AN
Chinese Journal of Endemiology 2017;36(4):241-245
Objective To explore the mechanism of cell apoptosis of immortalized human keratinocytes (HaCaT cells) and protein expression related to this process after long term exposure to sodium arsenite (NaAsO2,1.0 μmol/L).Methods Malignant transformation model was set up through long-term exposure of HaCaT cells to 1.0 μmol/L NaAsO2.Cell passage for 0,1,7,14,21,28 and 35 generations in the process of malignant transformation were collected for measurement of cell apoptosis rate by flow cytometry,and apoptosis related proteins by Western blotting,including activation of cysteine protease 3,8 (cleaved-caspase-3,8),C/EBP homologous protein (CHOP),B-cell leukemia/lymphoma 2 (Bcl-2),and Bcl-2 associated X protein (Bax).Results Along with the arsenite treatment,the apoptosis levels were significantly decreased (F =26.770,all P < 0.05),the apoptosis levels (0.307 ± 0.049,0.213 ± 0.055,0.163 ± 0.057,0.147 ± 0.035,0.053 ± 0.012) of the 7th,14th,21st,28th and 35thgenerations of cells after arsenite treatment were lower than that of control group of the 0th generation (0.393 ±0.021,all P < 0.05).Compared between generations,there were statistical differences of the protein expression levels of cleaved-caspase-3,Chop,Bax and Bcl-2 in arsenite group (cleaved-caspase-3:1.000 ± 0.000,1.030 ± 0.027,1.104 ± 0.069,1.016 ± 0.087,0.838 ± 0.075,0.753 ± 0.082,0.677 ± 0.073;Chop:1.000 ± 0.000,1.059 ± 0.018,0.934 ± 0.095,0.976 ± 0.216,0.793 ± 0.136,0.651 ± 0.042,0.564 ± 0.056;Bax:1.000 ± 0.000,1.069 ± 0.037,1.028 ± 0.042,0.954 ± 0.118,0.641 ± 0.135,0.531 ± 0.132,0.429 ± 0.085;Bcl-2:1.000 ± 0.000,1.072 ± 0.023,1.249 ± 0.134,1.334 ± 0.143,1.633 ± 0.221,1.507 ± 0.152,1.461 ± 0.145,F =7.730,7.355,27.802,12.438,all P < 0.05),compared with control group of the 0th generation (1.000 ± 0.000) and the same generation control group (1.000 ± 0.000),after the 21st generation,the differences were statistically significant (all P < 0.05),while there was no difference of the protein expression levels of cleaved-caspase-8 (F =0.832,P > 0.05).Conclusion In the process of malignant transformation,the apoptosis levels of HaCaT cells are inhibited after long term sodium arsenite exposure through mitochondria and endoplasmic reticulum (ER) stress signaling pathways.
6. Application of ICMM Occupational Health Risk Assessment Modelin evaluation of occupational risk of a lead-acid battery enterprise
Lin CHEN ; Xiurong QIAN ; Jiting LIU ; Weijiang HU ; Hengdong ZHANG ; Hong YANG
Chinese Journal of Industrial Hygiene and Occupational Diseases 2018;36(4):298-301
Objective:
ICMM occupational health risk assessment model was be used to evaluate the risk of a lead-acid battery enterprise.
Methods:
In November 2016, a lead-acid battery company in Jiangsu Province was selected as the research object. Based on the occupational health survey data and occupational hazard assessment reports, the ICMM risk assessment model was used to conduct occupational health risks in eight key positions of a lead-acid battery enterprise. The risk assessment results was verified by actual test results.
Results:
In the quantitative assessment model, the occupational health risk assessment results for the castings and welding positions exposed to lead smoke, and the occupational health risk assessment results for the grinding and dividing positions exposed to lead dust existed unacceptable risks. The occupational health risk assessment results for the ball-milled and plated positions exposed to lead dust existed tolerable risks. The occupational health risk assessment results for the lead-plated and soldered positions exposed to sulphuric acid pastes and acids existed potential risks. In qualitative evaluation matrix method, the occupational health risk assessment results for the castings and welding positions exposed to lead smoke, and the occupational health risk assessment results for the grinding and dividing positions exposed to lead dust existed high risks, the occupational health risk assessment results for other four key positions were considered to be with low risks.
Conclusion
The key control points for lead smoke in this enterprise were castings and welding positions; The key control points for lead dust were the grinding and separating brush positions. The quantitative assessment model and the qualitative assessment matrix method in the ICMM model were consistent with the actual test results in the eight health risk assessments of occupational hazards in key positions. Therefore, the method could be applied to the assessment of occupational health risks of the lead-acid battery enterprise. According to the results of the assessment, improvements could be made to high-risk positions and the concentration of occupational hazards in high-risk posts could be reduced to better protect the health of workers.
7. Characteristics of drug resistance and molecular typing of Salmonella enteritidis isolated in Shanxi Province
Suxia YAO ; Rui′e HAO ; Qiuxiang ZHANG ; Hongxia YANG ; Yang WANG ; Jiting HAN ; Xiaohong SONG ; Ye LIU
Chinese Journal of Microbiology and Immunology 2018;38(7):505-509
Objective:
To investigate the antimicrobial resistance status and pulsed field gel electrophoresis (PFGE) patterns of
8.Cyclic Stretch Promotes Migration of MC3T3-E1 Cells via Increasing Runx2 Expression
Xu YAN ; Zitong LI ; Jiting LIU ; Yingxin QI ; Jiong MEI
Journal of Medical Biomechanics 2022;37(1):E162-E168
Objective To investigate the effects of cyclic stretch on migration of MC3T3-E1 cells and its related mechanism. Methods The strain loading system was used to stretch MC3T3-E1 cells cultured in vitro with 15% amplitude, to simulate the mechanical condition in vivo. The wound healing assay was used to detect the migration of MC3T3-E1 cells. Western blotting was used to test Runx2 expression. RNA interfering was used to decrease Runx2 expression. Results Cyclic mechanical stretch with 15% amplitude, 1.25 Hz frequency and lasting for 24 hours could promote the migration of MC3T3-E1 cells and increase the expression level of Runx2. Runx2 interference inhibited the migration of MC3T3-E1 cells in static culture condition. Interference with Runx2 expression in MC3T3-E1 cells could partially reduce the positive effect of cyclic mechanical stretch on cell migration. Conclusions Cyclic stretch can promote the migration of MC3T3-E1 cells, and Runx2 may play an important role in this process. This study provides experimental basis for finding innovative clinical treatment method to promote fracture healing.