1.Study on the design of X-ray Flash-RT equipment with high power petal accelerator
Shuqing LIAO ; Xiaozhong HE ; Liu YANG ; Ruo TANG ; Tao WEI ; Zhuo ZHANG ; Jinshui SHI ; Jianjun DENG
China Medical Equipment 2024;21(1):21-23,28
Objective:To study and design one kind of flash radiotherapy(Flash-RT)equipment with ultra-high dose rate,which can be used in the mechanism research of Flash-RT with ultra-high dose rate.Methods:Based on the technique roadmap of high-power petal accelerator,the Flash-RT equipment can realize the requirement of Flash-RT for ultra-high dose rate and multiple irradiation angles.The corresponding design and research work were carried out on the basis of the overall design of the equipment,the main components and characteristics,the dynamics design of beam,the construction of movable and preliminary experimental platform,etc.Result:The dose rate of the designed equipment can reach to 100 Gy/s at a distance of 0.8 meters from the target point,which is easy to realize the radiotherapy method with multi angles.Conclusion:The designed X-ray equipment based on the technique roadmap of high-power petal accelerator can realize the research for the mechanism of medical Flash-RT equipment with ultra-high dose rate.
2.Research advance of clinical application of X-ray Flash-RT equipment
Ruo TANG ; Xiaozhong HE ; Pengfei ZHU ; Zhuo ZHANG ; Ziping HUANG ; Shuqing LIAO ; Tao WEI ; Liu YANG ; Jinshui SHI
China Medical Equipment 2024;21(1):24-28
The protection effect of flash-radiotherapy(Flash-RT)with super-high dose on normal tissue has obtained wide attention in therapeutic radiology since it was found in 2014 year.The increasing research demand of Flash-RT with super-high dose-rate proposed new challenge for the existing radiotherapy equipment.Based on the demands of FLASH-RT research and clinical application,this review analyzed the proposed new requirement of Flash-RT for equipment,and introduce current scientific facilities with the experimental ability of X-ray FLASH-RT,as well as the situation of the specialized FLASH-RT equipment which were developing.The research of Flash-RT mechanism need the existing equipment with high-energy X-ray source develop toward high power,while the clinical application of Flash-RT demand these transient high-power devices should possess a series of radiotherapy techniques such as multi angle irradiation,conformal radiotherapy and others.Currently,China's X-ray FLASH-RT research is at the forefront of the world,which is expected to achieve the first breakthrough of high-end medical equipment in the X-ray Flash RT field.
3.Application of theranostic nuclide in the era of accelerator
Jinshui SHI ; Zhengguo CHEN ; Yang DU ; Li ZHOU ; Yu LIU ; Pengfei ZHU
Chinese Journal of Nuclear Medicine and Molecular Imaging 2023;43(10):636-640
Irradiation based on accelerator is the main method of radionuclide production. In recent years, with the development of theranostics of nuclear medicine, there is a new demand for the preparation of accelerator radionuclides. In this paper, the nuclides and nuclide pairs of theranostics prepared by accelerators are divided into the three categories: nuclides of theranostics, nuclide pairs of theranostics of same element and different elements. The physical properties and current applications of some nuclides and nuclide pairs are introduced. The problems in the application of accelerator radionuclides preparation in China are analyzed, and the application prospect of the integration of accelerator radionuclides diagnosis and treatment is prospected.