1.A Study on the Availability of the On-Board Imager (OBI) and Cone-Beam CT (CBCT) in the Verification of Patient Set-up.
Jino BAK ; Sung Ho PARK ; Suk Won PARK
The Journal of the Korean Society for Therapeutic Radiology and Oncology 2008;26(2):118-125
PURPOSE: On-line image guided radiation therapy (on-line IGRT) and (kV X-ray images or cone beam CT images) were obtained by an on-board imager (OBI) and cone beam CT (CBCT), respectively. The images were then compared with simulated images to evaluate the patient's setup and correct for deviations. The setup deviations between the simulated images (kV or CBCT images), were computed from 2D/2D match or 3D/3D match programs, respectively. We then investigated the correctness of the calculated deviations. MATERIALS AND METHODS: After the simulation and treatment planning for the RANDO phantom, the phantom was positioned on the treatment table. The phantom setup process was performed with side wall lasers which standardized treatment setup of the phantom with the simulated images, after the establishment of tolerance limits for laser line thickness. After a known translation or rotation angle was applied to the phantom, the kV X-ray images and CBCT images were obtained. Next, 2D/2D match and 3D/3D match with simulation CT images were taken. Lastly, the results were analyzed for accuracy of positional correction. RESULTS: In the case of the 2D/2D match using kV X-ray and simulation images, a setup correction within 0.06degrees for rotation only, 1.8 mm for translation only, and 2.1 mm and 0.3degrees for both rotation and translation, respectively, was possible. As for the 3D/3D match using CBCT images, a correction within 0.03degrees for rotation only, 0.16 mm for translation only, and 1.5 mm for translation and 0.0degrees for rotation, respectively, was possible. CONCLUSION: The use of OBI or CBCT for the on-line IGRT provides the ability to exactly reproduce the simulated images in the setup of a patient in the treatment room. The fast detection and correction of a patient's positional error is possible in two dimensions via kV X-ray images from OBI and in three dimensions via CBCT with a higher accuracy. Consequently, the on-line IGRT represents a promising and reliable treatment procedure.
Cone-Beam Computed Tomography
;
Humans
;
Radiotherapy, Image-Guided
2.On-line Image Guided Radiation Therapy using Cone-Beam CT (CBCT).
Jino BAK ; Kyoungkeun JEONG ; Ki Chang KEUM ; Suk Won PARK
The Journal of the Korean Society for Therapeutic Radiology and Oncology 2006;24(4):294-299
PURPOSE: Using cone beam CT, we can compare the position of the patients at the simulation and the treatment. In on-line image guided radiation therapy, one can utilize this compared data and correct the patient position before treatments. Using cone beam CT, we investigated the errors induced by setting up the patients when use only the markings on the patients' skin. MATERIALS AND METHODS: We obtained the data of three patients that received radiation therapy at the Department of Radiation Oncology in Chung-Ang University during August 2006 and October 2006. Just as normal radiation therapy, patients were aligned on the treatment couch after the simulation and treatment planning. Patients were aligned with lasers according to the marking on the skin that were marked at the simulation time and then cone beam CTs were obtained. Cone beam CTs were fused and compared with simulation CTs and the displacement vectors were calculated. Treatment couches were adjusted according to the displacement vector before treatments. After the treatment, positions were verified with kV X-ray (OBI system). RESULTS: In the case of head and neck patients, the average sizes of the setup error vectors, given by the cone beam CT, were 0.19 cm for the patient A and 0.18 cm for the patient B. The standard deviations were 0.15 cm and 0.21 cm, each. On the other hand, in the case of the pelvis patient, the average and the standard deviation were 0.37 cm and 0.1 cm. CONCLUSION: Through the on-line IGRT using cone beam CT, we could correct the setup errors that could occur in the conventional radiotherapy. The importance of the on-line IGRT should be emphasized in the case of 3D conformal therapy and intensity-modulated radiotherapy, which have complex target shapes and steep dose gradients.
Cone-Beam Computed Tomography*
;
Hand
;
Head
;
Humans
;
Neck
;
Pelvis
;
Radiation Oncology
;
Radiotherapy
;
Radiotherapy, Image-Guided*
;
Radiotherapy, Intensity-Modulated
;
Skin
3.Radiation Dose-escalation Trial for Glioblastomas with 3D-conformal Radiotherapy.
Jae Ho CHO ; Chang Geol LEE ; Kyoung Ju KIM ; Jino BAK ; Se Byeoung LEE ; Sam Ju CHO ; Su Jung SHIM ; Dok Hyun YOON ; Hee Jong CHANG ; Tae Gon KIM ; Dong Suk KIM ; Chang Ok SUH
The Journal of the Korean Society for Therapeutic Radiology and Oncology 2004;22(4):237-246
PURPOSE: To investigate the effects of radiation dose-escalation on the treatment outcome, complications and the other prognostic variables for glioblastoma patients treated with 3D-conformal radiotherapy (3D-CRT). MATERIALS AND METHODS: Between Jan 1997 and July 2002, a total of 75 patients with histologically proven diagnosis of glioblastoma were analyzed. The patients who had a Karnofsky Performance Score (KPS) of 60 or higher, and received at least 50 Gy of radiation to the tumor bed were eligible. All the patients were divided into two arms; Arm 1, the high-dose group was enrolled prospectively, and Arm 2, the low-dose group served as a retrospective control. Arm 1 patients received 63~70 Gy (Median 66 Gy, fraction size 1.8~2 Gy) with 3D-conformal radiotherapy, and Arm 2 received 59.4 Gy or less (Median 59.4 Gy, fraction size 1.8 Gy) with 2D-conventional radiotherapy. The Gross Tumor Volume (GTV) was defined by the surgical margin and the residual gross tumor on a contrast enhanced MRI. Surrounding edema was not included in the Clinical Target Volume (CTV) in Arm 1, so as to reduce the risk of late radiation associated complications; whereas as in Arm 2 it was included. The overall survival and progression free survival times were calculated from the date of surgery using the Kaplan-Meier method. The time to progression was measured with serial neurologic examinations and MRI or CT scans after RT completion. Acute and late toxicities were evaluated using the Radiation Therapy Oncology Group neurotoxicity scores. RESULTS: During the relatively short follow up period of 14 months, the median overall survival and progression free survival times were 15+/-1.65 and 11+/-0.95 months, respectively. There was a significantly longer survival time for the Arm 1 patients compared to those in Arm 2 (p=0.028). For Arm 1 patients, the median survival and progression free survival times were 21+/-5.03 and 12+/-1.59 months, respectively, while for Arm 2 patients they were 14+/-0.94 and 10+/-1.63 months, respectively. Especially in terms of the 2-year survival rate, the high-dose group showed a much better survival time than the low-dose group; 44.7% versus 19.2%. Upon univariate analyses, age, performance status, location of tumor, extent of surgery, tumor volume and radiation dose group were significant factors for survival. Multivariate analyses confirmed that the impact of radiation dose on survival was independent of age, performance status, extent of surgery and target volume. During the follow-up period, complications related directly with radiation, such as radionecrosis, has not been identified. CONCLUSION: Using 3D-conformal radiotherapy, which is able to reduce the radiation dose to normal tissues compared to 2D-conventional treatment, up to 70 Gy of radiation could be delivered to the GTV without significant toxicity. As an approach to intensify local treatment, the radiation dose escalation through 3D-CRT can be expected to increase the overall and progression free survival times for patients with glioblastomas.
Arm
;
Diagnosis
;
Disease-Free Survival
;
Edema
;
Follow-Up Studies
;
Glioblastoma*
;
Humans
;
Magnetic Resonance Imaging
;
Multivariate Analysis
;
Neurologic Examination
;
Prospective Studies
;
Radiotherapy*
;
Retrospective Studies
;
Survival Rate
;
Tomography, X-Ray Computed
;
Treatment Outcome
;
Tumor Burden
4.Analysis of the Causes of Subfrontal Recurrence in Medulloblastoma and Its Salvage Treatment.
Jae Ho CHO ; Woong Sub KOOM ; Chang Geol LEE ; Kyoung Ju KIM ; Su Jung SHIM ; Jino BAK ; Kyoungkeun JEONG ; Tae Gon KIM ; Dong Seok KIM ; Joong Uhn CHOI ; Chang Ok SUH
The Journal of the Korean Society for Therapeutic Radiology and Oncology 2004;22(3):165-176
PURPOSE: Firstly, to analyze factors in terms of radiation treatment that might potentially cause subfrontal relapse in two patients who had been treated by craniospinal irradiation (CSI) for medulloblastoma. Secondly, to explore an effective salvage treatment for these relapses. MATERIALS AND METHODS: Two patients who had high-risk disease (T3bM1, T3bM3) were treated with combined chemoradiotherapy. CT-simulation based radiation-treatment planning (RTP) was performed. One patient who experienced relapse at 16 months after CSI was treated with salvage surgery followed by a 30.6 Gy IMRT (intensity modulated radiotherapy). The other patient whose tumor relapsed at 12 months after CSI was treated by surgery alone for the recurrence. To investigate factors that might potentially cause subfrontal relapse, we evaluated thoroughly the charts and treatment planning process including portal films, and tried to find out a method to give help for placing blocks appropriately between subfrotal-cribrifrom plate region and both eyes. To salvage subfrontal relapse in a patient, re-irradiation was planned after subtotal tumor removal. We have decided to treat this patient with IMRT because of the proximity of critical normal tissues and large burden of re-irradiation. With seven beam directions, the prescribed mean dose to PTV was 30.6 Gy (1.8 Gy fraction) and the doses to the optic nerves and eyes were limited to 25 Gy and 10 Gy, respectively. RESULTS: Review of radiotherapy portals clearly indicated that the subfrontal-cribriform plate region was excluded from the therapy beam by eye blocks in both cases, resulting in cold spot within the target volume. When the whole brain was rendered in 3-D after organ drawing in each slice, it was easier to judge appropriateness of the blocks in port film. IMRT planning showed excellent dose distributions (Mean doses to PTV, right and left optic nerves, right and left eyes: 31.1 Gy, 14.7 Gy, 13.9 Gy, 6.9 Gy, and 5.5 Gy, respectively. Maximum dose to PTV: 36 Gy). The patient who received IMRT is still alive with no evidence of recurrence and any neurologic complications for 1 year. CONCLUSION: To prevent recurrence of medulloblastoma in subfrontal-cribriform plate region, we need to pay close attention to the placement of eye blocks during the treatment. Once subfrontal recurrence has happened, IMRT may be a good choice for re-irradiation as a salvage treatment to maximize the differences of dose distributions between the normal tissues and target volume.
Brain
;
Chemoradiotherapy
;
Craniospinal Irradiation
;
Humans
;
Medulloblastoma*
;
Optic Nerve
;
Radiotherapy
;
Recurrence*