1.Pharmacological inhibition of STING signaling attenu-ates MPTP-induced neuroinflammation and neurode-generation in experimental models of Parkinson's disease
Baozhu WANG ; Jingru QIU ; Shuyan YU ; Deqing SUN ; Haiyan LOU
Chinese Journal of Pharmacology and Toxicology 2023;37(7):506-506
OBJECTIVE To investigate the effects of pharmacological inhibition of STING by C-176,a STING selective inhibitor,in experimental model of Parkinson's disease.METHODS The acute and sub-acute mice mod-els of Parkinson's disease(PD)were established by in-traperitoneal injection of 1-methyl-4-(2′-methylphenyl)-1,2,3,6-tetrahydrophine(MPTP).The selective STING inhibitor C-176 was administered by intraperitoneal injec-tion.The potential neuroprotective effects of C-176 were evaluated by behavioral test,tyrosine hydroxylase(TH)immunostaining,Nissl staining,Western blotting,qPCR and immunofluorescence.For in vitro study,the effects of C-176 on LPS/MPP+-induced inflammatory responses in BV2 microglial cells were determined by real time RT-PCR and Western blotting analysis.RESULTS Our study revealed that C-176 significantly inhibited STING signaling activation,ameliorated MPTP-induced dopami-nergic neurotoxicity,motor deficit and associated neuroin-flammation.Furthermore,pharmacological inhibition of STING in BV2 microglia treated with LPS/MPP+ exhibited decreased inflammatory responses.More importantly,C176 also reduced NLRP3 inflammasome activation both in vitro and in vivo.CONCLUSION The results of our study suggest that pharmacologic inhibition of STING protects against neuroinflammation that may act at least in part through suppressing NLRP3 inflammasome acti-vation and thus ameliorated dopaminergic neurodegener-ation.STING signaling may holds great promise for the development of new treatment strategy for PD as an effective therapeutic target.
2.Study on the dosimetry effect of rotational errors of a multi-channel cylinder applicator of vagina
Wenjun ZHANG ; Lang YU ; Bo YANG ; Jie ZHANG ; Chunli LUO ; Qizhen ZHU ; Jingru YANG ; Jie QIU
China Medical Equipment 2024;21(1):34-39,45
Objective:To investigate the dosimetry effect of rotational errors of multi-channel cylinder vaginal applicator of intravaginal irradiation after surgery of endometrial cancer.Methods:A total of 18 patients who underwent surgery of endometrial cancer at Peking Union Medical College Hospital from June to December 2022 were selected.The plans of patients who adopted the treatment of multi-channel cylinder applicator of vagina were retrospectively analyzed,which maintained the same retained mode with clinical plan.The applicator was rotated clockwise by 22.5? and 45.0?,respectively,simulating the rotational errors that occurred in placing the applicator among clinical inter-fractions.And then,the changes of dosimetry of target area and organs at risk(OAR)under two kinds of rotation amplitudes were further analyzed.Results:When the applicator was rotated as 22.5?,the minimum doses to 90%volumes of CTV by 2.03%than that of clinical plan,which was significantly different(t=5.86,P<0.05),and the maximal doses to 2cc of OARs of bladder and rectum respectively increased 2.35%and 2.71%,and the differences of them were statistically significant(t=-3.49,-2.40,P<0.05),respectively.When the applicator was rotated as 45?,the D90 of the target area decreased by 5.75%than that of clinical plan,which was statistically significant(t=14.07,P<0.05).The D2cc values of the bladder and rectum increased respectively by 6.50%and 9.49%than that of clinical plan,which were statistically significant(t=-7.72,-6.9,P<0.05).The differences of the exposed doses of sigmoid colon and small intestine after the applicator was rotated by 22.5? and 45.0? between the plan and original plan were respectively less,which were not statistical significance.Conclusion:The multi-channel cylinder applicator can provide individualized dose distribution in intravaginal irradiation.However,attention should be paid to the placement of the applicator when patients undergo inter-fractional treatment,in order to avoid deviations in the angular alignment from the original plan.This can impact the dosages of the target area and OARs.