1.An exploration of contributing factors to the oocyte utility rate of high responders in an in vitro fertilization cycle
Duoduo ZHANG ; Jingran ZHEN ; Qi YU
Chinese Journal of Obstetrics and Gynecology 2021;56(3):185-191
Objective:To figure out the clinical factors contributing to the oocytes utility rate (OUR) of high responders in in vitro fertilization (IVF)-embryo transfer treatment.Methods:OUR was defined by the number of usable embryos for transfer and (or) cryopreservation divided by the number of oocytes retrieved in a freeze-all cycle. The cycles with ≥15 eggs were included from January 2013 to December 2019. Those with OUR at the top 10% (Group A) and the bottom 10% (Group B) were picked and compared for patients′ characteristics, parameters relating to ovary stimulation and pregnant outcomes. Multifactorial logistic regression was applied to reveal the risk factors affecting OUR in them.Results:A total of 43 patients were included in Group A (OUR: 77.4%, 601/776) and 47 for Group B (OUR: 11.9%, 104/874). Previous IVF/intracytoplasmic sperm injection (ICSI; OR=0.10, 95% CI: 0.01-0.81) and endometriosis ( OR=0.16, 95% CI: 0.03-0.84) were negative factors for OUR ( P<0.05); dual suppression protocol ( OR=3.74, 95% CI: 1.06-26.86) and longer days of stimulation ( OR=3.24, 95% CI: 1.25-8.42) were protective factors in terms of ovarian stimulation ( P<0.05), on contrary to that, any decline of estradiol during the stimulation led to poorer OUR ( OR=0.16, 95% CI: 0.04-0.64). Although two groups had similar quantities of eggs and metaphase of meiosis Ⅱ (MⅡ) oocytes, distinguished cumulative clinical pregnancy rate and cumulative live birth rate were seen in Group A and group B respectively [95.3% (41/43) vs 40.4% (19/47) and 90.7% (39/43) vs 31.9% (15/47), all P<0.01]. Conclusions:High responders with attempted IVF/ICSI and endometriosis should be considered as risk factors for OUR. Over ovarian stimulation, dual suppression and a slightly longer stimulating duration could be tried; besides, estradiol decline should be prevented for a better OUR.
2.Cost-effectiveness analysis of two therapeutic methods for prolactinoma
Jingran ZHEN ; Qi YU ; Yuhui ZHANG ; Wenbin MA ; Shouqing LIN
Chinese Journal of Obstetrics and Gynecology 2008;43(4):257-261
Objective To evaluate the therapeutic responses to transsphenoidal surgery and medical therapy in terms of normalization of prolactin(PRL),mortality,morbidity and the cost-effectiveness of PRL normalization in order to establish an individualized therapeutic protocol for the patients with prolactinoma.Methods A retrospective study was undertaken of a consecutive series of patients with prolactinoma who were followed for at least 1 year after transsphenoidal surgery or medical treatment.The clinical characteristics and the long-term outcomes(normalization of PRL,morbidity or mortality)were assessed.Utilizing the principle of medical economics and data from the two types of treatment,we worked out a Markov chain and calculated the lowest cost of two kinds of therapeutic protocols.Results(1)The success rate of normalizing serum PRL through surgical treatment in microadenoma was 85%(22/26),and that of medical treatment was 95%(19/20).There was no statistical difference between the two therapies(P>0.05).The success rate of normalizing serum PRL through surgical treatment in macroadenoma was45%(19/42),and that of medical treatment was 5/5.There was a statistical difierence between the two therapies(P<0.05).(2)According to the Markov model,it would cost a microprolactinoma patient 25 129.25 yuan to normalize serum PRL by surgical treatment.This is comparable to the cost of medical treatment which would be 24 943.99 yuan.Whereas for a macroprolactinoma patient surgery would cost 35 208.20 yuan and medical treatment would cost 25 344.38 yuan.Conclusions Medical therapy is superior to surgical treatment in regard to complication rate and cost-effectiveness for macro-and extra big prolactinomas.Transsphenoidal surgery remains an option for patients with microadenomas.Markov model is an effective way to predict the treatment cost for patients with hyperprolactinoma at different ages and with different canses
3.Relationship between endometriosis fertility index and pregnancies after laparoscopic surgery in endometriosis-associated infertility
Daimin WEI ; Qi YU ; Aijun SUN ; Qinjie TIAN ; Rong CHEN ; Chengyan DENG ; Zhengyi SUN ; Jingran ZHEN ; Fangfang HE
Chinese Journal of Obstetrics and Gynecology 2011;46(11):806-808
Objective To evaluate the relationship between endometriosis fertility index (EFI) and pregnancies after laparoscopic surgery in endometriosis-associated infertility.Methods From Jan.2005 to Jan.2010,medical documents of 350 infertile patients due to endometriosis undergoing laparoscopic surgery were studied retrospectively.Pregnancy outcomes were followed up by telephone.EFI was calculated by history factors,least function score and some aspects of the revised American Fertility Society (r-AFS) endometriosis stage.The cumulative pregnancy rate was calculated and compared by Kaplan-Meier survival analysis.Results Within 3 years after surgery,the cumulative pregnancy rates among patients with EFI score 8,9,10 were 62.5%,69.8% and 81.1%,respectively.There was no significant difference in pregnancy rates among those three groups of patients ( P =0.24 ).The cumulative pregnancy rates among patients with EFI score 5,6,7 were 49.8%,43.9% and 41.6%,respectively,which did not reach statistical difference ( P =0.83 ).The cumulative pregnancy rates of EFI score 8 - 10 was significantly higher than that of EFI score 5 -7 (71.8% vs.44.4%,P =0.000).The patients with EFI score 0 -4 was quite small with only 33 cases,among which 15 cases were pregnant.Conclusions There is relationship between EFI and pregnancy in patients with endometriosis-associated infertility.EFI is meaningful to guide post surgical treatment.
4.Development and clinical feasibility of intelligent quality control system in gastroscopy
Jingran SU ; Zhen LI ; Xiaoyun YANG ; Xiuli ZUO ; Yanqing LI
Chinese Journal of Digestion 2020;40(11):751-757
Objective:To develop intelligent quality-control system (IQCS) based on deep convolutional neural networks (DCNN), and to prospectively evaluate the clinical feasibility of this system.Methods:Aimed at quality control objectives during gastroscopy such as the observation integrity of gastric mucosal, gastric mucosa visibility, time spent on gastroendoscopy and suspicious gastric cancer detection, four DCNN models including gastroscopic scanning location recognition model, gastric mucosa visibility recognition model, in vivo and in vitro identification model and gastric cancer detection model were designed. A total of 98 385 white light gastroscopy images were retrospectively collected from multiple centers for training and testing the DCNN models. The accuracy, sensitivity and specificity of each model were calculated and the receiver operating characteristic (ROC) curve was drawn. The models were integrated and formed the multi-function integrated IQCS. At the center of gastroendoscopy, Qilu Hospital of Shandong University, 100 consecutive patients who underwent routine gastroscopy were prospectively enrolled. The feasibility of IQCS in real clinical practice was evaluated. The condition of each quality control function of the system (average error point out or correct rate) and the detection of lesions after the examination were recorded. Results:The accuracy, sensitivity and specificity of the model of gastroscopic scanning location recognition to identify each site were 98.40% to 99.85%, 61.95% to 100.00% and 98.65% to 100.00%, respectively; the area under curve (AUC) of ROC curve ranged from 0.997 6 to 1.000 0. The accuracy, sensitivity and specificity of the model of gastric mucosa visibility recognition to identity the mucosal visibility were 97.02% to 98.27%, 85.14% to 99.28% and 93.72% to 100.00%, respectively. The accuracy, sensitivity and specificity of the model of in vivo and in vitro identification were 97.27%, 99.85% and 94.50%, respectively; the AUC of ROC was 0.961 5. The accuracy, sensitivity and specificity of the model of gastric cancer detection were 95.92%, 95.64% and 96.05%, respectively; the AUC of ROC was 0.975 9. The results of feasibility evaluation of IQCS indicated that in the quality control of gastric mucosa observation integrity, the system average error was 0.32 time/case; in the quality control of mucosal visibility, the system average error was 0.47 time/case; the correct rate of intelligent timing during gastroscopy was 96.00%, in the quality control of suspicious gastric cancer detection, the system average error was 0.36 time/case. A total of 3 cases of gastric cancer and 1 case of high grade gastric intraepithelial neoplasia were detected. The system could accurately identify the location. Conclusions:Gastroscopy IQCS can accurately achieve quality control in the observation integrity of gastric mucosa, gastric mucosa visibility, time spent on gastroendoscopy and suspicious gastric cancer detection in actual examination, which makes accurate and efficient gastroscopy quality control possible.