1.Analysis on mycoplasma infection status in genital tract and its drug susceptibility
Jinghong PENG ; Jun LIU ; Guoying ZHANG ; Weizhong ZHUANG ; Yanqiang HOU
International Journal of Laboratory Medicine 2014;(13):1738-1739
Objective To understand the status of mycoplasma infection and drug susceptibility to provide reference basis for clinical rational drug use.Methods The reagents kits produced by Shanghai Aopu Biopharmaceutical Co.,Ltd.were adopted to per-form the mycoplasma culture,identification and susceptibility test.Results Among 1 745 specimens,896 cases of mycoplasma in-fection were detected with the total detection rate of 51 .35%,including Ureaplasma urealyticum (Uu)infection in 841 cases (48.19% ),Uu combined Mycoplasma hominis(Mh)infection in 92 cases(5.27% )and Mh infection in 17 cases(0.97%).The de-tection rate was 9.46% in males and 41 .89% in females,the infection rate in females was obviously higher than that of males.The results of drug susceptibility test showed that the sensitive rate to doxycycline,josamycin and minocycline was higher than 95%, while the resistant rate to norfloxacin and lincomycin was higher than 75%.Conclusion Mycoplasma infection in this hospital is dominated by Uu.Doxycycline,josamycin and minocycline can be used as the empirical medication to treat mycoplasma infections in this hospital.But before clinical treatment,the mycoplasma culture and the drug susceptibility test should be performed as possible for rational and standardized medication.
2.Dosimetric analysis of 3D-printed coplanar template-assisted and CT-guided 125I seed implantation for the treatment of malignant tumors
Ran PENG ; Yuliang JIANG ; Zhe JI ; Fuxin GUO ; Haitao SUN ; Jinghong FAN ; Xu LI ; Junjie WANG
Chinese Journal of Radiation Oncology 2017;26(9):1062-1066
Objective To compare the pre-and post-operative tumor target volume and to examine the consistency in physical dosimetric parameters of organs at risk (OAR) following 3D-printed coplanar template (3D-PCT)-assisted and CT-guided radioactive seed implantation.Methods The 3D-printed coplanar template was designed using a computer software, and the coordinate system was established where the center was used as the basis for setting the x axis and y axis.Crosses defining the center of treatment were drawn on the patient''s body and matched with the corresponding central point, x axis, and y axis of the coplanar template.3D-PCT-assisted and CT-guided radioactive seed implantation was performed based on the pre-operative plan, and the pre-operative, operative, and post-operative plans were designed to evaluate the target tumor volume and the normal dose received by the tissues.In addition, dosimetric parameters, including D90(minimum dose received by 90% of the gross target volume), V100, V150, V200(percentage of GTV that received 100%, 150%, and 200% of the prescribed dose, respectively), minimum peripheral dose (MPD), conformal index (CI), external index (EI), and homogeneity index (HI) in the pre-operative and post-operative plans were also assessed and compared using the Wilcoxon test. Results Fourteen patients treated in our institution from August to October, 2016 were included in this study. The median age of the patients was 61.5 years, and the median Karnofsky Performance Scale score was 80. A total of 14 lesions from the 14 patients were treated by seed implantation in the neck (n=4), chest (n=3), abdomen (n=5), and pelvis (n=2). Of the 14 patients that underwent implantation, 8 had previously received radiation therapy, and 6 had not received radiation therapy. Dosage optimization was performed for all patients during the operation. The median activity of the implanted seeds was 0.625 mCi (0.55-0.75 mCi,1 Ci=3.7×1010 Bq), and the preoperatively planned median number of needling and implanted seeds were 9(4-34) and 45.5(10-162), respectively. However, the actual median number of needling and implanted seeds were 9.5(4-34) and 45.5(10-162), respectively. Dosimetric analysis showed that there were no significant changes in tumor volume (P=0.135), D90(P=0.208), MPD (P=0.104), V100(P=0.542), V150(P=0.754), V200(P=0.583), CI (P=0.426), EI (P=0.326), and HI (P=0.952) after implantation. Conclusions 3D-PCT guidance and dosage optimization can result in good consistency between pre-and post-operative plans for radioactive seed implantation. 3D-PCT is a convenient and cheap technique suitable for large-scale clinical application.
3.Dosimetric assessment of CT-guided radioactive seed implantation assisted by 3D printing non-coplanar template in treatment of chest malignant tumor
Zhe JI ; Yuliang JIANG ; Fuxin GUO ; Ran PENG ; Haitao SUN ; Jinghong FAN ; Junjie WANG
Chinese Journal of Radiation Oncology 2017;26(7):754-758
Objective To compare the preoperative and postoperative dosimetric results of radioactive seed implantation assisted by 3D printing template in the treatment of chest malignant tumor, and to examine the effect this technique on the precision of radioactive seed implantation.Methods A total of 21 patients who received 3D printing template-assisted CT-guided 125I seed implantation for chest tumors in 2016 were included in the study.The prescribed dose of the treatment was 110-180 Gy.Preoperative planning, individual template production, and puncture and seed implantation were performed in all patients, and the postoperative dosimetric results were then compared with the preoperative plan by assessing various dosimetric parameters including D90, MPD, V100, V150, CI, EI, and HI of gross tumor volume (GTV), D2cc of the spinal cord and aorta, and Dmean and V20 of the affected side of the lung.Statistical analysis was performed using the Wilcoxon non-parametric test.Results A total of 21 3D printing templates were designed and produced.The mean GTV volume (preoperative) of all patients was 77.1 cm3, and the mean number of implanted seeds was 68.In addition, the mean D90 of the postoperative GTV was 147.3 Gy.There were slight changes in the dosimetric parameters after treatment (P>0.05).Conclusions 3D printing template allows for accurate positioning and implantation of radioactive seeds during the treatment of chest tumor.Postoperative dosimetric parameters were consistent with those in the preoperative planning, indicating that the 3D printing template provides high precision for the treatment of chest tumor.
4.Aromatase inhibitors and TAM in the treatment of post-menopausal Luminal B breast cancer patients
Jinghong ZHANG ; Yan LIU ; Xiaomeng HAO ; Rui HUI ; Fenglin ZANG ; Peng LIU ; Yuanxi ZHU ; Yi YANG ; Jin ZHANG
Chinese Journal of General Surgery 2010;25(6):449-452
Objective To evaluate a therapeutic strategy using aromatase inhibitors and TAM in postmenopausal Luminal B breast cancer patients. Methods The clinical data of 733 primary breast cancer cases receiving postoperative endocrine thempy from July 2002 to Mar 2005 in Tianjin Cancer Hospital were retrospectively analyzed.Diagnosis was confirmed by pathology in all the cases.All patients were post-menopausal and ER-positive.501 patients were given tamoxifen(TAM 2.5 mg qd,po),232 patients were given aromatase inhibitors(Letrozole 10 mg bid,po).The follow-up time ranged from 36 to 90 months.Median follow-up time was 46 months.Results The disease-free-survival(DFS)rate of Luminal B breast cancer patients in aromatase inhibitors(AIS)group was higherthan that in TAM group(90.6% vs.88.6%,P=0.038).In TAM group,subgroup analysis showed 3-year DFS of node-positive with HER2(+)is lower than that of node-positive with Her-2-negative(88.2% vs.90.4%,P=0.037);3-year DFS of ER+/PR+ group in HER2(+) patients was higher than that of ER+/PR-group(90.8% vs.89.5%.P=0.032).In AIs group,in spite of the axillary lymph node status,there was no significant difference of 3-year DFS between HER2(+)patients and HER2(-)ones(P>0.05).3-year DFS of ER+/PR+with HER2(+) patients was higher than that of ER+/PR-ones with HER2(+)(91.9% vs.90.5%,P=0.029).Hot flush,vaginal bleeding and thromboembolics in AIS group is less frequent,but muscle pain and bone fracture is more common than that in TAM group(P<0.05).Conclusion Compared to TAM, AIs is more effective and safer with postmenopausal Luminal B patients,and the effect is independent on node stams.
5.Side effect of radioactive 125I seed implantation for recurrent malignant tumor of head and neck assisted by 3D-printing individual guide plate
Yuliang JIANG ; Zhe JI ; Fuxin GUO ; Ran PENG ; Haitao SUN ; Jinghong FAN ; Weiyan LI ; Kai LIU ; Jinhua LEI ; Junjie WANG
Chinese Journal of Radiological Medicine and Protection 2017;37(7):495-499
Objective To investigate the acute side effect of 3D printing individual non-coplanar template for 125I seed implantation in head and neck recurrent/ metastatic carcinoma.Methods Between January 2016 and December 2016,42 patients of local recurrent malignant tumor of head and neck received 3D printing guide plate assist radioactive seeds implantations,and included in the study.The tumor volume ranged from 2.4 to 102.8 cm3 (median 28.6 cm3).The prescribed dose is 110-160 Gy,and the seeds activity were 0.34 to 0.70 mCi (1 Ci =3.7 × 1010 Bq).All patients carried out preoperative planning design,individual guide plate production,seed implantation,postoperative dose assessment,and followup.The side effects of skin,mucous membrane,blood and spinal cord were statistically analyzed.Results All patients were operated successfully.The follow-up time was 4-14 months (median 8.5 months).There were no adverse reactions at grade three or above.Three patients had grade one skin reaction.One patient experienced grade one mucosal reaction,two experienced grade two mucosal reactions.The skin response was correlated with the dose of the skin (x2 =7.067,P =0.032).No hematologic toxicity or radiation myelopathy was observed and no seed displacement was found.Conclusions 3D-printing guide plate can provide good accuracy for positioning and direction.For local recurrent malignant tumor of head and neck,there were no obvious adverse reactions and the operation was simple and the dosage was accurate.
6.3D-printing non-coplanar template assisted CT-guided 125I seed implantation on pelvic recurrent cervical cancer
Ping JIANG ; Fuxin GUO ; Yuliang JIANG ; Zhe JI ; Ran PENG ; Haitao SUN ; Jinghong FAN ; Xu LI ; Weiyan LI ; Junjie WANG
Chinese Journal of Radiological Medicine and Protection 2017;37(7):490-494
Objective To investigate the accuracy of 3D-printing non-coplanar template (3D-PNCT) assisted 125I seed implantation with CT guidance in the pelvic recurrent cervical between the preplan and post-plan dosimetric parameters.Methods Nine patients with pelvic recurrent cervical cancer received 125I seed implantation under CT guidance assisted with 3D-PNCT.A pre-plan based brachytherapy treatment planning system (B-TPS) assisted with 3D-PNCT for seed needle depth,direction and angle was designed.The dosimetry parameters including homogeneity index (HI),dose of 90% target volume (Dg0),mPD,volume percent of 100%,150% and 200% prescribed dose V100,V150 and V200 and organ at risk between the pre-plan and post-plan were compared.Results Total seeds number was 675 (median 44,25-114) according to pre-plan,and 669 (median 47,25-113) seeds were implanted actually.138 needles need implant according to preplan,and 132 needles was implanted actually.The median angle deviation was 1.99 ° ± 2.94°(0 °-13 °).There was no significant difference of HI,EI and CI between perand post-plan.The differences of D90,MPD,V100,V150 and V200 between pre-and post-plan were not significant.Conclusions The confidence of pre-plan and post-plan for 3D-PNCT assisted 125I seed implantation in the pelvic recurrent cervical cancer could be accurately performed under CT guidance.
7.3D-printing non-coplanar template assisted 125I seed implantation for pelvic tumor: individual template design method
Haitao SUN ; Lihong YAO ; Junjie WANG ; Fugen ZHOU ; Yuliang JIANG ; Zhe JI ; Bo LIU ; Fuxin GUO ; Ran PENG ; Jinghong FAN
Chinese Journal of Radiological Medicine and Protection 2017;37(7):485-489
Objective To compare the dosimetric data between preoperative plans and postoperative verification in computed tomography (CT)-guided and 3D-printing non-coplanar templateassisted 125I seed implantation for pelvic tumor,and to explore the feasibility and accuracy of the personalized template designmethod.Methods A total of 51 patients registered from Dec 2015 to Dec 2016 who were applied with 3D-printing guided template assisted radioactive seed implantations in the hospital were included in this study.A prescribed dose of 110-160 Gy was adopted.3D-printing templates were designed and produced for 51 cases.The dosimetric parameters:Dg0,minimum peripheral dose (mPD),V100,V150,V200,conformal index (CI),external index (EI),and homogeneity index (HI) were compared between pre-and post-plans.Results 51 cases' templates were in place well during the operations.Compared with the preoperative planning,the postoperative D90,V100,V150,V200,CI,EI and HI differences had no statistical difference (P > 0.05);mPD is larger than before (t =-2.96,P < 0.05).Conclusions The main dosimetric parameters of postoperative verification were consistent well with the preoperative planning and have good accuracy,which could meet the clinical requirements.
8.The review of Amomum villosum in Xishuangbanna.
Jian-Ming PENG ; Li-Xia ZHANG ; Jie MA ; Zhi-Bin GUAN
China Journal of Chinese Materia Medica 2006;31(2):97-101
The researches on quality evaluation, chemical composition, pharmacological actions and plantation of Amomum villosum in Xishuangbanna was reviewed. The further research point were proposed.
Amomum
;
chemistry
;
growth & development
;
Analgesics
;
pharmacology
;
Animals
;
China
;
Drugs, Chinese Herbal
;
isolation & purification
;
pharmacology
;
Oils, Volatile
;
isolation & purification
;
pharmacology
;
Plants, Medicinal
;
chemistry
;
growth & development
9.Testing methods for seed quality of Amomum villosum.
Lixia ZHANG ; Xuelan LI ; Deying TANG ; Yanhong GUAN ; Jianming PENG
China Journal of Chinese Materia Medica 2011;36(22):3086-3090
OBJECTIVEThe aim of this study was to optimize the testing methods for seed quality, and to provide a basis for establishing seed testing criterion and quality standard of Amomum villosum.
METHODReferring to the International Seed Testing Rules made by ISTA and Rules for agricultural seed testing, the seed quality of A. villosum from different collection areas was measured.
RESULTThe samples weight of A. villosum for purity analysis were at least 500 g and for test were at least 50 g. Verification of genuineness was assayed by seed appearance comparing and weight of per hundred seeds was determined, the moisture content test was carried out by high temperature drying method (3 hours). The seeds were stored in wet sand for 20 days and then dipping in the 100 mg x L(-1) GA3 for 30 days before germination, seeds on filter papers germinated at 30/20 degrees C. The first germination-counting time was the 15th day of the test and the final time was the 50th day. Seed viability was tested by TTC method.
CONCLUSIONThe seed testing methods for quality items of A. villosum, including sampling, purity analysis, verification of genuineness, weight, moisture content, percentage germination and seed viability of A. villosum had been initially established.
Amomum ; chemistry ; Germination ; Quality Control ; Seeds ; chemistry ; Water ; analysis
10.Dosimetry evaluation for CT guided 125I seeds implantation assisted by three-dimensional-printing coplanar coordinate template in chest malignant tumor
Zhe JI ; Yuliang JIANG ; Fuxin GUO ; Ran PENG ; Haitao SUN ; Jinghong FAN ; Junjie WANG
Chinese Journal of Nuclear Medicine and Molecular Imaging 2018;38(1):4-8
Objective To verify the accuracy of three-dimensional printing coplanar coordinate template (3D-PCCT) technology for 125I seeds implantations in chest tumor at dosimetry level.Methods From January 2016 to June 2017,a total of 22 patients (15 males,7 females;median age 62 years) with chest tumors who received 3D-PCCT assisted 125I seeds implantation in Peking University Third Hospital were enrolled in this retrospective study.There were 8 patients with primary lung cancer and 14 with metastatic carcinoma.The sites for implantation included lung (12 cases),mediastinum (2 cases) and chest wall (8 cases).The prescribed dose was 110-180 Gy.The preoperative plan design,puncture and seeds implantation guided by template were carried out and the dose distribution of postoperative plan was compared with that of preoperative plan.Dose parameters included dose delivered to 90% gross tumor volume (D90),minimum peripheral dose,the percentage of GTV receiving 100% prescription dose (V100),the percentage of GTV receiving 150% prescription dose (V150),conformity index,external index of target volume,uniformity index,D2 cm3 of spinal cord and aorta,and V20 of affected side lung.Wilcoxon signed rank test was used to analyze the data.Results The median D90 was 150.4(125.6,187.0) Gy.Postoperative D90 was higher than the prescribed dose in 68% (15/22) cases.For median value of most parameters,there were no significant differences between the postoperative plans and preoperative plans (all P>0.05) except for the actual V100,which was lower than the preplanned (95.5% vs 97.2%;P=O.040).Conclusion 3D-PCCT could provide good accuracy in 125I seeds implantation for chest tumor.