1.Usefulness of myocardial performance index for assessing right ventricular function after percutaneous closure of atrial septal defect
Jingdong DING ; Genshan MA ; Yaoyao HUANG ; Xiaoli ZHANG ; Jian ZHU ; Rong YANG
Journal of Geriatric Cardiology 2007;4(4):220-224
Objective Assessment of right ventricular function in patients with atrial septal defect (ASD) is difficult. The Doppler myocardial performance index (MPI) may provide a method of assessing function in these patients. The purposes of this study were to evaluate the right ventricular function and its changes in patients with ASD after transcatheter closure of ASD. Methods MPI, defined as the sum of isovolumic relaxation time and isovolumic contraction time derived by ejection time, was measured from tricuspid inflow and right ventricular outflow; Doppler velocity profiles recorded during routine echocardiography. Twenty nine patients ( 13 men, 16 women;mean age 25.28 ± 12.69, range 6 to 57 years) were diagnosed to secundum ASD [the stretched diameters of ASD were from 9 To 36 (24.91 ±7.98) mm], and had a successfully placed Amplatzer septal occluder (ASO) (the sizes of ASO were from 11 to 40 mm ); there were 81 sex-matched, age-matched healthy people (control group 41men, 40 women; mean age 29.02 ± 14.22, range 4 to 45 years).MPI was measured again on 3 days and 1 month after closure of ASD. Change in the study group was assessed and compared to the control subjects with structurally normal hearts. A complete 2- dimensional and Doppler echocardiographic examination was performed in all study groups. Results 1) The isovolumic relaxation and isovolumic contraction times [respectively(77.59 ± 14.39)ms vs (60.93 ± 12.94)ms, P<0.0001; (28.28 ± 10.88)ms vs (23.64 ± 9.01)ms, P=0.027] were prolonged, and ejection time [(260.65 ± 21.86 )ms vs (271.85 ± 21.92)ms, P=0.033] was shortened in patients with ASD compared with that in control subjects, resulting in a marked increase in the MPI(0.40 ± 0.07 vs 0.31 ± 0.05, P<0.0001) from normal values; 2) by Pearson's correlations, the MPI had no correlation with heart rate and blood pressure in control subjects and patients with ASD, but it correlated positively with age in patients with ASD; 3) by Pearson's correlations, the MPI correlated positively with the diameter of ASD and pulmonary artery pressure; 4) after transcatheter closure of ASD, the MPI decreased markedly. Conclusions 1) MPI is a conceptually new, simple, and reproducible Doppler index in patients with ASD; 2) MPI is free from the effect of age, heart rate and blood pressure; (3) MPI appears to be relatively dependent on changes in the diameter of ASD and pulmonary artery pressure; 4) the right ventricular function was improved after transcatheter closure of ASD.
2.Accuracy of mixed venous oxygen saturation in reflecting change in cardiac output during off-pump coronary artery bypass grafting
Li ZHENG ; Yu ZHEN ; Ning MA ; Guannan DING ; Qingyuan HUAI ; Jingdong KE ; Ming TIAN
Chinese Journal of Anesthesiology 2010;30(5):589-591
Objective To assess the accuracy of mixed venous oxygen saturation ( S(-v)O2 ) in reflecting the change in CO during off-pump coronary artery bypass grafting (OPCABG) .Methods Twenty-five NYHA Ⅰ -Ⅲ patients of both sexes, aged 50-75 yr, weighing 55-85 kg, undergoing OPCABG, were studied. Anesthesia was induced with midazolam, fentanyl, etomidate and pipecuronium and maintained with propofol infusion and intermittent iv boluses of fentanyl and pipecuronium supplemented with isoflurane if necessary. The patients were mechanically ventilated (VT 8-10 ml/kg, RR 8-10 bpm, I:E 1:2). PETCO2 was maintained at 35-45 mm Hg.Radial artery was cannulated and pulmonary catheter was placed. CI, S(-v)O2 and Hb were monitored and recorded before skin incision, during anastomosis with left anterior descending artery (LAD), right coronary artery (RCA)and left circumflex coronary artery (LCX), when the chest was closed, when the patients' body position was changed and the heart was manipulated. S(-v)O2 and CI were scaled immediately after the pulmonary artery catheter was placed and before anastomosing LAD. Results The CO change in S(-v)O2 was real-time and accurate in reflecting the body positioning and elevation of hearts. There was no simultaneous significant change in CI.Conclusion The CO change in S(-v)O2 is real-time and accurate in reflecting the body positioning and elevation of hearts during OPCABG.