1.Study on Quality Standard for Shengji Ointment
Da TONG ; Jing QIU ; Ruilian LI
China Pharmacist 2017;20(3):565-567
Objective:To improve the quality standard for Shengji ointment. Methods:A TLC method was used to identify Resina draconis and Olibanum. An HPLC method was used to determine the content of silver sulfadiazine. The detection wavelength was set at 254 nm. The determination was performed on a Wondasil C18 column(250 mm × 4. 6 mm, 5 μm) with the mobile phase consisting of acetonitrile-0. 1% phosphoric acid(8: 92). The injection volume was 5 μl. Results:The TLC spots were clear, specific and repro-ducible. A good linear relationship was obtained between the peak areas and the concentrations of sulfadiazine within the range of 40. 97-1024. 18 μg·ml-1(r=0. 9999). The average recovery was 100. 17% (RSD=0. 64%,n=6). Conclusion: The methods are easy-operated, specific, reproducible and accurate, which can be used for the quality control of the preparation.
2.Determination of Amantadine Hydrochloride in Pediatric Paracetamol and Amanatadine Hydrochloride Granules by GC
Jing QIU ; Da TONG ; Xiaoyan LI
China Pharmacist 2015;(6):1067-1069
Objective:To establish a GC method for determining the content of amantadine hydrochloride in pediatric paracetamol and amanatadine hydrochloride granules. Methods:The ingredients were separated on an Agilent DB-5 quartz capillary column (30 m ×0.25 mm, 0.25 μm), the carrier gas was N2,and the flow rate was 1 ml·min-1. The column temperature was maintained at 130℃, the injection temperature was 250℃,the detection temperature was 280℃ with an FID as the detector , the injection volume was 2 μl, and the split ratio was 20∶1. Results:A good linear relationship was obtained between the peak area and the concentration of amantadine hydrochloride within the range from 0.103 2 to 6.456 0 mg·ml-1(r =0.999 9). The average recovery was 100.18%(RSD=0. 11%, n=6). Conclusion:The method is specific, accurate, reliable and reproducible, which can be used in the quality control of pediatric paracetamol and amanatadine hydrochloride granules.
3.Case of Meige syndrome.
Chinese Acupuncture & Moxibustion 2014;34(12):1178-1178
7.Development of all-direction move device for the leg support of lithotomy position surgical bed
Jianping DA ; Wenfang CHEN ; Jing CHEN
China Medical Equipment 2014;(12):44-45
Objective: To design a convenient and safe leg support of lithotomy position surgical bed. Methods:Put the gas spring in the device to lift and drop the leg support, instead of turning screw, And then use the new leg support in 80 lithotomy position surgeries. Results:The new device can be operated by one man, it is easy operating and labor saving. There was no leg slip occurred in 80 surgeries, operators all expressed satisfaction. Conclusion: This innovation patent solved the problem of toilsome operating and potential safety hazard, It worth widely use in the clinical.
8.Application progress of radiolabeled drugs in new drug research and development in China
Xing-xing DIAO ; Jing-hua YU ; Da-fang ZHONG
Acta Pharmaceutica Sinica 2023;58(2):313-319
The metabolism study of radiolabeled drugs plays an important role in the development of new drugs. It provides information on drug absorption, metabolism, tissue distribution and excretion, and plays an irreplaceable role in the metabolite safety evaluation and mass balance of new drugs. The new guidance draft on clinical trials of radiolabeled drugs recently released by the US FDA puts forward higher standards and has been widely concerned by the industry. In recent years, in the research and development of new drugs in China, 14C labeled drugs have been used to carry out clinical metabolism studies, which has overcome key technical bottlenecks and accumulated experience. This paper summarizes the above research progress, analyzes the existing problems, and preliminarily looks forward to the future technological development and application.
9.Precision of three-dimensional printed brackets
Da ZHANG ; Linchuan WANG ; Yanheng ZHOU ; Xiaomo LIU ; Jing LI
Journal of Peking University(Health Sciences) 2017;49(4):704-708
Objective:This study was based on digital orthodontic diagnosis work flow for indirect bonding transfer tray model design and three-dimensional (3D) printing, and the aim of this paper was to inspect the dimensional accuracyof 3D printed brackets, which is the foundation of the follow up work and hoped that will illuminate the clinical application of the digital orthodontics work flow.Methods: The samples which consisted of 14 cases of patients with malocclusion from Department of Orthodontics Peking University were selected, including 8 cases with tooth extraction and 6 cases without tooth extraction.All the 14 patients were taken intra-oral scan (Trios 3Shape,Denmark)and cone-beam computed tomography (CBCT, NewTom 3G volumetric scanner, Aperio Service,Italy)shooting after periodontal treatment.STL data and DICOM data were obtained from intraoral scans and CBCT images.Data segmentation, registration, fusion, automatic tooth arrangement, virtual positioning of orthodontic appliance and conversion the coordinates of malocclusion model were all done with self-programming software.The data of 3D printing model with brackets on it were output finally and printed out with EDEN260V (Objet Geometries, Israel) to make indirect bonding transfer tray.Digital vernier caliper was used to measure the length and width of upper and lower left brackets and buccal tubes on those 3D models after removal of surrounding supporting material by ultrasonic vibration and water-spray.Intra-examiner reliability was assessed by using intra-class correlation coefficients (ICC), and one-sample T test was used to compare the measurements with the standard dimensional data of the brackets.Results: There were significant differences which range in 0.04-0.17 mm between the 13 items out of the 19 measurement items.Except for the length of the lower left premolars''brackets, mean values of the other items were greater than the test value.Conclusion: Although the measurement results in the width of brackets and the width and length of the buccal tubes obtained experimentally were slightly larger than the test value,this may not reduce the accuracy of indirect bonding procedure in clinic necessarily.Whether the differences which range in 0.04-0.17 mm would actually affect the retention and positioning of brackets needs to be confirmed by further studies.
10.The Assembly of a Novel Enzyme Biosensor for Aflatoxin B_1 Detection
Da-Ling LIU ; Yi SHEN ; Jing ZHANG ; Dong-Sheng YAO ;
China Biotechnology 2006;0(03):-
A novel biosensor for aflatoxin B1 detecting has been reported. The biosensor electrode for AFB1 detecting was assembled by immobilized aflatoxin-oxidoreductase using open-ended multi-walled carbon nanotubes as matrix. Its linear range was between 0.16?M and 3.2?M. And if the specific anti-aflatoxin B1 antibody and aflatoxin oxidoreductase were both immobilized on the electrode with Multi-Walled carbon nanotubes, the detection limit of the modified electrode could be 16 nM with a 10 times improved sensitivity. The aflatoxin enzyme biosensor assembled this way strode one step forward its practical application.