1.Clinical validation of the 2020 diagnostic approach for pediatric autoimmune encephalitis in a single center.
Jina Dong WANG ; Lei XIE ; Xiao FANG ; Zhi Hong ZHUO ; Pei Na JIN ; Xiao Lei FAN ; Hai Ying LI ; Hui Min KONG ; Yao WANG ; Huai Li WANG
Chinese Journal of Pediatrics 2022;60(8):786-791
Objective: To evaluate the value of the 2020 diagnostic criteria (Cellucci criteria) for pediatric autoimmune encephalitis (AE) in children with suspected AE in a single center. Methods: The clinical data of 121 children hospitalized at the First Affiliated Hospital of Zhengzhou University from October 2019 to October 2021, with a diagnosis of suspected AE, were retrospectively collected and analyzed. The children were divided into definite antibody-positive AE (dAPAE), probable antibody-negative AE (prANAE), possible AE (pAE) and non-AE groups according to the Chinese expert consensus and the Graus criteria. A new diagnosis was made according to the Cellucci criteria which was compared with the clinical diagnosis to evaluate the diagnostic value of the Cellucci criteria. The Mann-Whitney U test, Kruskal-Wallis test, and χ2 test were used to compare the differences among groups. The sensitivity and specificity were used to evaluate efficacy of the Cellucci criteria. Results: Among the 121 children, 72 were males and 49 were females, with an age of 10.3 (6.5, 14.0) years at disease onset. There were 99 cases diagnosed as AE according the clinical diagnosis (58 males and 41 females), of which 43 cases were diagnosed as dAPAE, 14 cases as prANAE and 42 cases as pAE, and the other 22 cases were not AE (14 males and 8 females). The top 2 initial symptoms in the 99 children with AE were seizures (53 cases, 53.5%) and abnormal mental behaviors (35 cases, 35.4%). And the most common symptoms during the course of the disease were abnormal mental behaviors (77 cases, 77.8%) and seizures (64 cases, 64.6%). There were statistically differences in the incidence of consciousness disorders, autonomic dysfunctions during the course of the disease and the length of hospitalization among the 4 groups (χ2=21.63, 13.74, H=22.60, all P<0.05). Ninety-six of the 121 children were tested for AE-related antibodies, of which 45 cases (46.9%) were antibody-positive. According to the Cellucci criteria, 42 cases were diagnosed as dAPAE, 34 cases as prANAE and 14 cases as pAE. Compared with the clinical diagnosis, the sensitivity of the Cellucci criteria for the diagnosis of the 3 types of AE were 93.02%, 92.86% and 87.88%, and the specificity were 96.23%, 74.39% and 86.36%, respectively. Conclusions: The Cellucci criteria has a high sensitivity and specificity for the diagnosis of pAE and dAPAE in the clinical management of children with suspected AE, while a high sensitivity but low specificity for the diagnosis of prANAE. Therefore, it is recommended to apply the Cellucci criteria selectively in clinical practice according to the actual situation, especially in the diagnosis of prANAE.
Child
;
Encephalitis/diagnosis*
;
Female
;
Hashimoto Disease/diagnosis*
;
Humans
;
Male
;
Retrospective Studies
;
Seizures
2.HbA1c comparison and diagnostic efficacy analysis of multi center different glycosylated hemoglobin detection systems.
Ping LI ; Ying WU ; Yan XIE ; Feng CHEN ; Shao qiang CHEN ; Yun Hao LI ; Qing Qing LU ; Jing LI ; Yong Wei LI ; Dong Xu PEI ; Ya Jun CHEN ; Hui CHEN ; Yan LI ; Wei WANG ; Hai WANG ; He Tao YU ; Zhu BA ; De CHENG ; Le Ping NING ; Chang Liang LUO ; Xiao Song QIN ; Jin ZHANG ; Ning WU ; Hui Jun XIE ; Jina Hua PAN ; Jian SHUI ; Jian WANG ; Jun Ping YANG ; Xing Hui LIU ; Feng Xia XU ; Lei YANG ; Li Yi HU ; Qun ZHANG ; Biao LI ; Qing Lin LIU ; Man ZHANG ; Shou Jun SHEN ; Min Min JIANG ; Yong WU ; Jin Wei HU ; Shuang Quan LIU ; Da Yong GU ; Xiao Bing XIE
Chinese Journal of Preventive Medicine 2023;57(7):1047-1058
Objective: Compare and analyze the results of the domestic Lanyi AH600 glycated hemoglobin analyzer and other different detection systems to understand the comparability of the detection results of different detectors, and establish the best cut point of Lanyi AH600 determination of haemoglobin A1c (HbA1c) in the diagnosis of diabetes. Methods: Multi center cohort study was adopted. The clinical laboratory departments of 18 medical institutions independently collected test samples from their respective hospitals from March to April 2022, and independently completed comparative analysis of the evaluated instrument (Lanyi AH600) and the reference instrument HbA1c. The reference instruments include four different brands of glycosylated hemoglobin meters, including Arkray, Bio-Rad, DOSOH, and Huizhong. Scatter plot was used to calculate the correlation between the results of different detection systems, and the regression equation was calculated. The consistency analysis between the results of different detection systems was evaluated by Bland Altman method. Consistency judgment principles: (1) When the 95% limits of agreement (95% LoA) of the measurement difference was within 0.4% HbA1c and the measurement score was≥80 points, the comparison consistency was good; (2) When the measurement difference of 95% LoA exceeded 0.4% HbA1c, and the measurement score was≥80 points, the comparison consistency was relatively good; (3) The measurement score was less than 80 points, the comparison consistency was poor. The difference between the results of different detection systems was tested by paired sample T test or Wilcoxon paired sign rank sum test; The best cut-off point of diabetes was analyzed by receiver operating characteristic curve (ROC). Results: The correlation coefficient R2 of results between Lanyi AH600 and the reference instrument in 16 hospitals is≥0.99; The Bland Altman consistency analysis showed that the difference of 95% LoA in Nanjing Maternity and Child Health Care Hospital in Jiangsu Province (reference instrument: Arkray HA8180) was -0.486%-0.325%, and the measurement score was 94.6 points (473/500); The difference of 95% LoA in the Tibetan Traditional Medical Hospital of TAR (reference instrument: Bio-Rad Variant II) was -0.727%-0.612%, and the measurement score was 89.8 points; The difference of 95% LoA in the People's Hospital of Chongqing Liang Jiang New Area (reference instrument: Huizhong MQ-2000PT) was -0.231%-0.461%, and the measurement score was 96.6 points; The difference of 95% LoA in the Taihe Hospital of traditional Chinese Medicine in Anhui Province (reference instrument: Huizhong MQ-2000PT) was -0.469%-0.479%, and the measurement score was 91.9 points. The other 14 hospitals, Lanyi AH600, were compared with 4 reference instrument brands, the difference of 95% LoA was less than 0.4% HbA1c, and the scores were all greater than 95 points. The results of paired sample T test or Wilcoxon paired sign rank sum test showed that there was no statistically significant difference between Lanyi AH600 and the reference instrument Arkray HA8180 (Z=1.665,P=0.096), with no statistical difference. The mean difference between the measured values of the two instruments was 0.004%. The comparison data of Lanyi AH600 and the reference instrument of all other institutions had significant differences (all P<0.001), however, it was necessary to consider whether it was within the clinical acceptable range in combination with the results of the Bland-Altman consistency analysis. The ROC curve of HbA1c detected by Lanyi AH600 in 985 patients with diabetes and 3 423 patients with non-diabetes was analyzed, the area under curve (AUC) was 0.877, the standard error was 0.007, and the 95% confidence interval 95%CI was (0.864, 0.891), which was statistically significant (P<0.001). The maximum value of Youden index was 0.634, and the corresponding HbA1c cut point was 6.235%. The sensitivity and specificity of diabetes diagnosis were 76.2% and 87.2%, respectively. Conclusion: Among the hospitals and instruments currently included in this study, among these four hospitals included Nanjing Maternity and Child Health Care Hospital in Jiangsu Province (reference instrument: Arkray HA8180), Tibetan Traditional Medical Hospital of TAR (reference instrument: Bio-Rad Variant Ⅱ), the People's Hospital of Chongqing Liang Jiang New Area (reference instrument: Huizhong MQ-2000PT), and the Taihe Hospital of traditional Chinese Medicine in Anhui Province (reference instrument: Huizhong MQ-2000PT), the comparison between Lanyi AH600 and the reference instruments showed relatively good consistency, while the other 14 hospitals involved four different brands of reference instruments: Arkray, Bio-Rad, DOSOH, and Huizhong, Lanyi AH600 had good consistency with its comparison. The best cut point of the domestic Lanyi AH600 for detecting HbA1c in the diagnosis of diabetes is 6.235%.
Pregnancy
;
Child
;
Humans
;
Female
;
Glycated Hemoglobin
;
Cohort Studies
;
Diabetes Mellitus/diagnosis*
;
Sensitivity and Specificity
;
ROC Curve