1.Spatial distribution of radiation dose field from mobile CT head scanning
Jinge ZHANG ; Wanlin PENG ; Zhenlin LI ; Chunchao XIA ; Jin PU
Chinese Journal of Radiological Medicine and Protection 2017;37(4):302-305
Objective To identify the spatial distribution of stray radiation from mobile CT head scanning for the purpose of radiation protection.Methods The head series of CareTom mobile CT were scanned and the radiation dose was measured using TLD (LiF:Mg,Cu,P).The isodose maps of radiation dose field were plotted using Matlab software.Results Radiation dose in the front of the mobile CT was slightly higher than that in the back.The maximum value of 0.255 mGy was found to be at 0.5 m from the scanning hole center.Conclusions The stray radiation dose from mobile CT head scanning was relatively low.However in order to avoid the damage to the operators and other medical workers from long-term low dose exposure,it should keep 2 m away from mobile CT,beside or behind,when in operation.
2.Expression of microRNA-203 and P63 in human epidermal stem cells and keratinocytes.
Zhi-fang SONG ; Dewu LIU ; Yan PENG ; Jin LI ; Zhiwei ZHANG ; Pu NING ; Yanghong HU
Chinese Journal of Burns 2014;30(4):344-348
OBJECTIVETo observe the changes in expression of microRNA-203 and P63 in human epidermal stem cells and KCs, and to investigate their effects and significance in the epidermal proliferation and differentiation.
METHODS(1) Five normal foreskin tissue specimens were collected from 5 patients by circumcision in Department of Urinary Surgery of the First Affiliated Hospital of Nanchang University from March to June in 2013. Then single cell suspension was obtained by separating epidermis with trypsin digestion method. The cells were divided into quick adherent cells and non-quick adherent cells by type IV collagen differential adherent method. The biological characteristics of cells were observed by inverted phase contrast microscope immediately after isolation and on post culture day (PCD) 3. The expression of CD29, keratin 19, keratin 1, and keratin 10 was identified by immunocytochemical staining. The expression of microRNA-203 and mRNA of P63 was determined by real-time fluorescent quantitative RT-PCR. The protein expression of P63 was determined by Western blotting. Data were processed with t test and Pearson correlation analysis.
RESULTS(1) Immediately after isolation, quick adherent cells were small, round, and dispersed uniformly. On PCD 3, the cells adhered firmly, and they grew in clones. Immediately after isolation, non-quick adherent cells appeared in different shapes and sizes, and dispersed unevenly. On PCD 3, the cells adhered precariously and did not show clonal growth. Quick adherent cells showed positive expression of CD29 and keratin 19, while non-quick adherent cells showed positive expression of keratin 1 and keratin 10. Quick adherent cells were identified as epidermal stem cells, and non-quick adherent cells were identified as KCs. (2)The expression level of microRNA-203 in epidermal stem cells (0.74 ± 0.20) was lower than that in KCs (3.66 ± 0.34, t =16.582, P <0.001). The mRNA expression level of P63 in epidermal stem cells (4. 16 ± 0.28) was higher than that in KCs (2.90 ± 0.39, t =5. 850, P =0.001). The protein expression level of P63 in epidermal stem cells (1.42 ± 0.05) was higher than that in KCs (0.73 ± 0.03, t =26.460, P <0. 001). (3) The expression level of microRNA-203 was in significantly negative correlation with the expression levels of mRNA and protein of P63 (with r values respectively - 0. 94 and -0.98 , P values below 0.05).
CONCLUSIONSThe expression levels of microRNA-203 and P63 in human epidermal stem cells and KCs were significantly different, which might be related to the different characteristics of proliferation and differentiation of the cells.
Cell Differentiation ; Cells, Cultured ; Epidermis ; cytology ; growth & development ; Epithelial Cells ; cytology ; metabolism ; Gene Expression Profiling ; Gene Expression Regulation, Developmental ; Humans ; Integrin beta1 ; Keratin-10 ; genetics ; metabolism ; Keratin-19 ; genetics ; metabolism ; Keratinocytes ; Male ; Membrane Proteins ; genetics ; metabolism ; MicroRNAs ; genetics ; metabolism ; Stem Cells ; cytology ; metabolism
3.Imaging findings of coronary sinus with left atrium muscle connections on dual-source CT coronary angiography
Zehua PENG ; Weifang KONG ; Hong PU ; Lin BAI ; Jiayuan CHEN ; Jin JIANG ; Gang LI
Chinese Journal of Radiology 2012;46(10):890-895
ObjectiveTo investigate the morphologic features of coronary sinus (CS)-left atrium muscle connections,and evaluate the function and anatomical features of coronary sinus on dual-source CT coronary angiography (DSCTCA).MethodsImages of DSCTCA of 144 patients [ control group consisted of 96 patients,and atrial fibrillation (AF) group consisted of 48 patients] were reviewed.The existence of coronary sinus-right atrium muscle connections was indirectly evaluated by measuring the cross-sectional area changes of the CS during atrial systole and atrial diastolic.The number,location,length of the CS-left atrium muscle connections andthe relationship between CS-left atrium muscle connections and CS morphological characteristics were studied.The t test for continuous variables and Chi-square test for categorical variables were used in statistical analysis.Results( 1 )The anatomic course of the CS in relation to the mitral ring was straight,mild curvature and high riding of 62,16 and 18 cases in control group and 10,8 and 30 cases in AF group,respectively.There was not statistical significance between the 2 group (x2 =0.093,P=0.954). (2)The CS length was (34.1 ±9.1),(33.8 ±8.9)mm in Control group and AF group,respectively.There was no statistical significance between the 2 group ( t =- 0.486,P =0.628 ).(3) Coronary sinus-left atrium muscle connections were seen in 131 of the 144 patients (91.0%).A single connection was seen in 103 of the 144 patients,with a mean length of (22.6 ± 12.7)mm within (6.3 ± 5.8 ) mm of the coronary sinus ostium.28 patients had two connections; distal connections measured ( 13.2 ± 6.2)mm in length within (16.7 ± 6.8 ) mm of the coronary sinus ostium,and proximal connections measured ( 11.1 ± 3.6 ) mm in length within (2.1 ± 1.9) mm of the coronary sinus ostium.And there was no statistical difference the number and length of CS-left atrium connections in between Control group and AF group (P > 0.05 ).(4)The CS narrowed 22.4% (44.5/198.8 )in cross-sectional area from atrial diastolic to atrial systole in control group( t =- 21.076,P < 0.01 ),while the CS had no obvious contraction in AF group(t =0.374,P > 0.05).The cross-sectional area of the coronary sinus during diastole was obviously larger in the AF group than in the control group[( 230.4 ±77.0) mm2 vs (198.8 ±65.4) mm2,respectively,t =- 2.579,P =0.01 ].In control group ( n =9 ),the coronary sinus-left atrium connection was not seen,however,all showed a CS constriction during atrial systole,indicating that coronary sinus-left atrium muscle continuity is not likely the primary cause for coronary sinus contractions. Conclusions DSCTCA can clearly show the anatomical characteristics of CS,it can help to understand the length,number and location of the CS-left atrium muscle connection.
4.Abdominal CT scan in predicting complications of acute pancreatitis
Zehua PENG ; Lin BAI ; Hong PU ; Longlin YIN ; Jiayuan CHEN ; Jin JIANG ; Ning AN
Chinese Journal of General Surgery 2012;27(10):789-793
Objective To evaluate abdominal CT scan in predicting complications and mortality of acute pancreatitis patients. Methods CT imaging data of 606 AP patients from June 2010 to October 2011 were analyzed retrospectively. Fatty liver, pleural effusion, suprahepatic space effusion, biliary tract disease,gastric bare area involvement (GBAI),adrenal gland involvement (AGI) and perirenal space involvement (PSI) were evaluated,and the relationship between CT findings and complications and mortality was analyzed. Results (1) The Logistic regression analysis showed six risk factors for complications of AP,including obesity,fatty liver,PSI,AGI,GBAI and suprahepatic space effusion.The sensitivity,specificity and accuracy of Logistic regression model for predicting complications were 81.3%,89.1% and 85.3 %,respectively. (2) The Logistic regression analysis showed four risk factors for mortality of AP,including obesity,AGI,GBA and suprahepatic space effusion.The sensitivity,specificity and accuracy of Logistic regression model for predicting mortality were 33.3%, 98.6%, 96.0%, respectively.Conclusions Abdominal CT scan effectively indicates the signs of tissue and organ involvement in AP.These CT findings relate with the prognosis of AP.
5.Pharmaceutical evaluation of hydroxycamptothecin nanosuspensions with the action of inhibiting P-gp.
Xiaohui PU ; Jin SUN ; Yimeng QIN ; Xiao ZHANG ; Peng ZHANG ; Zhonggui HE
Acta Pharmaceutica Sinica 2011;46(7):834-8
Oral hydroxycamptothecin nanosuspension (HCPT-Nano) with high supersaturated dissolution level, high permeation and well physical stability, was manufactured by microprecipitation-high press homogenization method. Its pharmaceutical properties were investigated, such as size and distribution, zeta potential, particle shape, physical existence condition, supersaturated dissolution level and so on. Particle size was measured by laser diffraction, and the mean diameters before and after lyophilization were 138 +/- 11.72 nm and 175 +/- 12.74 nm, respectively, for HCPT-Nano. Zeta potentials of HCPT-Nano was over -20 mV. The nanoparticles, being observed by transmission electron microscopy (TEM), were claviform or column in shape. DSC and X-ray diffraction revealed that HCPT existed in the form of crystal for HCPT-Nano. And HCPT-Nano could maintain higher supersaturated dissolution level for long time. So it supplied the possibility of improving oral bioavailability of HCPT when combining together admoveatur of P-gp inhibitor, CsA.
6.Imaging findings of Bachmann bundle and its arterial supply on dual-source CT coronary angiography
Zehua PENG ; Hong PU ; Lin BAI ; Longlin YIN ; Jiayuan CHEN ; Jin JIANG ; Gang LI
Chinese Journal of Radiology 2011;45(1):26-31
Objective To investigate the morphologic features of Bachmann bundle (BB) and its vascular supply on dual-source CT coronary angiography(DSCTCA) in healthy volunteers and patients with coronary artery lesion (CAL). Methods Clinical histories, electrocardiograms (ECGs), and images of DSCTCA of 106 patients ( CAL group) and 100 healthy volunteers ( Control group) were reviewed. All 106 patients underwent conventional coronary angiography ( CCA ). The Gensini scoring system was used to assess the results of CCA. The patients were divided into three groups according to their Gensini scores. The length, width and superoinferior diameter, CT value, and vascular supply of BB were studied. Rank sum test for continuous variables and Chi-square test for categorical variables were used in statistical analysis.Results ( 1 ) BB visualization rate of control group was higher than CAL group [86.0% (86/100) vs 51.9%(55/106), x2 = 27.726, P < 0.01]. The higher the Gensini score of CAL subgroup, the lower the visualization rate of its BB [80.0% ( 28/35 ), 55.6% ( 20/36 ), 20.0% ( 7/35 ), x2 = 25.530, P < 0.01].(2)The median of measurements of length,width and superoinferior diameter of control and CAL group were 13.0 vs 13.8,5.0 vs 5.2 and 5.9 vs 6.2 mm, respectively ( P > 0.05 ). (3) The CT value of the BB region in control group( median :42.6 HU ) was higher than that of CAL group( median: 13.0 HU) ( Z = - 7.061, P <0.01). The CT values of BB regions in patients with nonvisualized BB (median: -16.0 HU) were lower. The CT values of the BB regions in CAL group were negatively-correlated with Gensini scores( median:19.0) (r = -0.553, P <0.01 ). (4)The blood supply of BB and BB region was provided by right sinuatrial node artery ( SNA, 58.7%, 121/206 ), left SNA ( 35.9%, 74/206 ) or both SNAs ( 5.3%, 11/206 ).Conclusions DSCTCA could can show the anatomical characteristics of BB and its arterial supply. The serious the degree of CAL , the lower the BB display rate, and the higher the abnormal ECG incidence,which indicate that the occurrence of BB lesions is probably related to ischemia.
7.Clinical applications of routine subtraction and dual-energy subtraction cervical arteries computed tomographic angiography for cervical arteries imaging.
Hong PU ; Lin BAI ; Ze-hua PENG ; Jia-yuan CHEN ; Jin JIANG
Acta Academiae Medicinae Sinicae 2010;32(6):611-614
OBJECTIVETo compare with the clinical applications of routine-subtraction and dual-energy subtraction cervical arteries computed tomographic angiography (CTA) for cervical arteries imaging.
METHODSScanning was performed in 45 patients with clinically suspected cervical arteries disease with dual-source CT. The data of two different energy were collected only at one scanning. The data post processing include: conventional bone-removal digital subtraction (routine-subtraction) was performed with plain and 80 kV enhanced scanning. Volume render (VR) and maximum intensity projection (MIp) reconstruction were finished. Direct bone-removal digital subtraction (dual-energy subtraction) was performed with 80 and 140kV enhanced scanning that have different energy, and saving the data of subtraction. VR and MIp reconstruction were finished. The image quality, which was divided into four grades, was compared between these two groups. The effective radiation dose was also compared.
RESULTSFor normal vessels, no abnormality was found in 24 of 45 cases, with the common carotid artery and its branches clearly displayed with both two methods. The image quality was not significantly different between dual-energy subtraction CTA and routine subtraction CTA (P>0.05) . For stenotic vessels, 45 stenotic vessels in 21 cases were clearly displayed clearly with both two methods (P>0.05) . The effective radiation dose was decreased by 17.3 % for dual-energy subtraction CTA when compared with routine-subtraction CTA (P<0.01) .
CONCLUSIONSBoth routine-subtraction and dual-energy subtraction CTA can clearly display normal and stenotic vessels. The radiation exposure dose is relatively lower in dual-energy CTA. The dual-energy subtraction CTA has better effectiveness when used for non-cooperation patients.
Adult ; Aged ; Aged, 80 and over ; Angiography, Digital Subtraction ; methods ; Carotid Artery Diseases ; diagnostic imaging ; Female ; Humans ; Male ; Middle Aged ; Radiation Dosage ; Sensitivity and Specificity ; Tomography, X-Ray Computed ; methods
8.The clinical value of anteroposterior and lateral scout image combined with Care Dose 4D and Care kV in reducing radiation dose of chest CT scanning
Fei ZHAO ; Lei LI ; Jin PU ; Wanlin PENG ; Yuming LI ; Kai ZHANG ; Jinge ZHANG ; Keling LIU ; Chunchao XIA ; Zhenlin LI
Chinese Journal of Radiological Medicine and Protection 2017;37(5):389-392
Objective To investigate the feasibility and clinical value of anteroposterior and lateral scout scan combined with Care Dose 4D and Care kV in chest CT scan.Methods A total of 60 patients of clinical diagnosis with lung tumor were enrolled.Those patients were randomly divided into test group and control group.Control group underwent a scan protocol with lateral scout scan combined with Care Dose 4D and Care kV,while anteroposterior and lateral scout scan combined with Care Dose 4D and Care kV were performed in test group.The signal-to-noise ration (SNR),contrast-to-noise ratio (CNR),and overall image quality of two groups of images and diseased tissues were analyzed and evaluated by two high-grade radiologists using double-blind method.Effective doses (E) were also calculated.Results All the 60 patients had successfully completed the chest CT scans.Test group overall image quality (4.57 ± 0.45) and control group overall image quality (4.73 ± 0.45) had no statistically significant difference (P > 0.05).The control group image SNR,CNR and diseased tissue SNR,CNR compared with test group had no statistical significance difference (P > 0.05).The difference of the volume CT dose index (CTDIvol),dose-length product (DLP) and effective dose (E) of test group and control group was statistically significant (t =8.514,8.464,8.464,P < 0.001).Compared with control group,the effective dose of test group decreased by 33.3%.Conclusions Compared with lateral scout scan,the technology of anteroposterior and lateral scout scan combined with Care Dose 4D and Care kV can decrease radiation dose without reducing the image quality.This technology can therefore be considered as a regular imaging modality for chest CT scan.
9.Frequency of transfusion transmitted virus in healthy infants in Jiujiang city Jiangxi province.
Yi-hong PENG ; Ji-hong CAO ; Qing WANG ; Lie-pu HU ; Xue-sen ZHAO ; Jin PENG
Chinese Journal of Epidemiology 2004;25(1):54-57
OBJECTIVETransfusion transmitted virus (TTV) DNA was detected in serum samples obtained from healthy infants and volunteer blood donors living in Jiujiang city in an attempt to shed light on the prevalence of TTV infection and the transmission route of TTV infection in infants.
METHODSModified untranslated region, polymerase chain reaction (UTR PCR) and N22 PCR were performed to test TTV DNA in serum samples from 86 infants and 58 blood donors.
RESULTSTTV DNA was detected by UTR PCR in 51 (53.5%) infants and 58 (100%) in blood donors, while that tested by N22 PCR was 14 (16.3%) and 22 (37.3%) in infants and blood donors, respectively. Among infants younger than 30 days, 1 - 6 months and 7 - 12 months of age, TTV DNA was detected by UTR PCR and N22 PCR at rates of 0, 33.3%, 95.0% and 0, 7.4%, 30.0%, respectively.
CONCLUSIONThe prevalence rates of TTV DNA detected by UTR PCR were 95% in infants of 7 - 12 months after birth and 100% in healthy blood donors in Jiujiang city. However the results obtained by N22 PCR were much less frequently in the same population. Results showed that significant difference did exist in the prevalence of TTV DNA detected by the two different PCR systems. Age-dependent increase of TTV infection was observed in early childhood, while environmental sources were considered to be the most common route of TTV acquisition as the primary infection in infants. However, the prevalence of TTV in infants of 7 - 12 months was similar to that in healthy adults in the same region.
Base Sequence ; China ; epidemiology ; DNA Virus Infections ; epidemiology ; virology ; DNA, Viral ; chemistry ; genetics ; Humans ; Infant ; Infant, Newborn ; Molecular Sequence Data ; Polymerase Chain Reaction ; Prevalence ; Sequence Analysis, DNA ; Sequence Homology, Nucleic Acid ; Torque teno virus ; genetics
10.Construction of multifunctonal nano-delivery system crossing blood brain barrier.
Peng YAO ; Jie HUANG ; Chun-Sheng KANG ; Pei-Yu PU ; Jin CHANG
Acta Academiae Medicinae Sinicae 2006;28(4):481-485
OBJECTIVETo construct multifunctonal nano-delivery system crossing the blood brain barrier (BBB).
METHODSThe magnetic nanoparticles were preprared with O-carboxylmethylated chitosan (O-CMC) and conjugated with a peptide sequence from the human immunodeficiency virus 1-tat protein and transferrin (Tf), and anti-tumor drug methotrexate (MTX), and thus constructed a O-CMC magnetic nanoparticles carrier system conjugating with Tat and Tf (O-MNPs-Tat-Tf) that combines multiple functions including crossing BBB, magnetism, receptor-mediated dual targets and anti-tumor capabilities. The appearance, diameter, and magnetism of MTX-O-MNPs-Tat-Tf carrier system were characterized with transmission electronic microscopy, atomic force microscopy and vibrating samples magnetometer. The cytotoxicity of MTX-loaded O-MNPs-Tat-Tf was investigated with C6 glioma cells. The ability of O-MNPs-Tat-Tf crossing BBB was investigated in rats by single photon emission computed tomography.
RESULTSThe mean particle diameter was 75 nm, along with good anti-tumor property. The multi-functioned carrier system successfully crossed the BBB in rat.
CONCLUSIONThe establishment of MTX-O-MNPs-Tat-Tf carrier model implies a promising future for its application in therapy of cerebral diseases.
Blood-Brain Barrier ; drug effects ; metabolism ; Chitosan ; analogs & derivatives ; chemistry ; Drug Carriers ; Drug Delivery Systems ; Humans ; Magnetics ; Nanoparticles ; Transferrin