1.Studies on pharmacokinetics of loganin and morroniside in Cornus officinalis injection in mice.
Lan-tong ZHANG ; Lei-ming REN ; Jin-kun WUN
China Journal of Chinese Materia Medica 2003;28(6):509-512
OBJECTIVETo establish a revered-phase HPLC method for the study of pharmacokinetics of loganin and morroniside in Cornus officinalis injectionin mice after a single oral and intravenous administrations.
METHODThe Diamonsil C18 column (4.6 mm x 250 mm, 5 microns) was used as the analytical column and the mobile phase consisted of acetonitrile-methanol-0.2% formic acid (12:8:80) with the flow rate at 1.0 mL.min-1. The UV detection was set at 237 nm.
RESULTThe calibration curves of loganin and morroniside were linear in the range from 0.38 to 68.25 mg.L-1(r = 0.9999), and from 0.66 to 117.22 mg.L-1(r = 0.9999), respectively. The lowest determination concentrations of loganin and morroniside were 0.10 and 0.16 mg.L-1, respectively. The recoveries and relative standard deviations of loganin were 99.6% (2.0%), 102.0% (1.0%), 87.9% (7.2%), and those of morroniside were 99.2% (2.5%), 104.1% (1.2%), 92.7% (4.2%), respectively. The relative standard deviations of within-day and between-day precision for the method were all less than 6.8%. After a single intravenous administration of Cornus officinalis injection to mice, the mean plasma concentration-time courses were found to fit a two-compartment open model, the main pharmacokinetic parameters of loganin were as follows: T1/2(alpha), T1/2(beta), K21, K12, K10, V(c), AUC, CL were 3.2 min, 25.1 min, 5.997 h-1, 4.981 h-1, 3.564 h-1, 0.551 L.kg-1, 13.59 mg.L-1.h, 1.965 L.kg-1.h-1, respectively and those of morroniside were 3.6 min, 21.5 min, 5.926 h-1, 3.833 h-1, 3.797 h-1, 0.647 L.kg-1, 27.15 mg.L-1.h, 2.457 L.kg-1.h-1, respectively.
CONCLUSIONIt is the first time to establish the revered-phase HPLC method to determine concentrations of loganin and morroniside in plasma and to obtain their pharmacokinetic parameters and characteristics.
Administration, Oral ; Animals ; Area Under Curve ; Chromatography, High Pressure Liquid ; Cornus ; chemistry ; Drugs, Chinese Herbal ; administration & dosage ; isolation & purification ; pharmacokinetics ; Female ; Injections, Intravenous ; Iridoids ; blood ; Male ; Mice ; Plants, Medicinal ; chemistry
2.Evaluation of Weaning Criteria from Mechanical Ventilatory Support.
Young Joo LEE ; Haeng Jae KIM ; Taeg Hwan BAE ; Sang Kun HAN ; Keum Hee CHUNG ; Jang Wun YUN ; Jae Woo JIN ; Chol KIM
The Korean Journal of Critical Care Medicine 1998;13(1):79-84
Introduction: A number of indices have been proposed as accurate predictors of weaning, but several studies have questioned the accuracy of these weaning indices in predicting the capability of independent breathing. The purpose of the study was to assess six standard bedside weaning criteria of mechanically ventilated patients in Surgical intensive care unit (SICM). METHOD: : The study was performed on 72 SICU patients who were mechanically ventilated. According to the outcome of weaning, they were divided into two groups, weaning success (n=62) and weaning failure (n=10) group. All subjects should have PaO2 above 60 mm Hg at an FIO2 of 0.4 and PEEP of 3~5 cm H2O in the extubated patients and no PEEP in the tracheostomy patients. Six bedside weaning criteria were tidal volume above 5 ml/kg, respiratory rate below 25/min, vital capacity above 10 ml/kg, maximum inspiratory pressure below -20 cm H2O, minute volume below 10 L/min and PaO2/FIO2 above 200. Weaning failure was regarded as follows; changes of systolic blood pressure 20 mm Hg or diastolic pressure 10 mm Hg, changes of pulse rate 20 beat per minute, respiratory rate above 30 per minute or increased respiratory rate above 10 per minute, PaO2 below 60 mm Hg or PaCO2 above 55 mm Hg, and presence of paradoxical respiratory pattern. RESULTS: PaO2/FIO2 and minute volume (VE) were showed statistically significant difference between two groups (P=0.048, P=0.003 respectively). Linear discriminant function was D=-1.422-0.005-xPaO2/FIO2+0.336xVE. CONCLUSION: Our study demonstrates that PaO2/FIO2 and minute volume accurately predicts the weaning outcome in the surgical patients with mechanical support.
Blood Pressure
;
Discriminant Analysis
;
Heart Rate
;
Humans
;
Critical Care
;
Respiration
;
Respiration, Artificial
;
Respiratory Rate
;
Tidal Volume
;
Tracheostomy
;
Vital Capacity
;
Weaning*