1.Preliminary efficacy observation of 3D printed functional spinal external fixation brace combined with McKenzie therapy in the treatment of lumbar disc herniation.
Ning-Xia WANG ; Ping CHEN ; Hai-Dong WANG ; Jing JI ; Fang-Hong NIAN ; Xin LIU ; Chong-Fei JIN ; Duo-Ming ZHAO ; Hao-Lin LI ; Wei-Gang CHENG ; Gui-Lin LAI ; Guo-Biao WU
China Journal of Orthopaedics and Traumatology 2025;38(10):1047-1054
OBJECTIVE:
To observe the clinical efficacy of 3D printing spinal external fixator combined with McKenzie therapy for patients with lumbar dics herniation (LDH).
METHODS:
Sixty patients with LDH between January 2022 and January 2023 were enrolled. Among them, 30 patients were given McKinsey training. According to different treatment methods, all patients were divided into McKenzie group and McKenzie + 3D printing group, 30 patients in each group. The McKenzie group provided McKenzie therapy. The McKenzie + 3D printing group were treated with 3D printing spinal external fixation brace on the basis of McKenzie therapy. Patients in both groups were between 25 and 60 years of age and had their first illness. In the McKenzie group, there were 19 males and 11 females, with an average age of (48.57±5.86) years old, and the disease duration was (7.03 ±2.39) months. The McKenzie + 3D printing group, there were 21 males and 9 females, with an average age of (48.80±5.92) years old, and the disease duration was(7.30±2.56) months. Pain was evaluated using the visual analogue scale (VAS), and lumbar spine function was assessed using the Oswestry disability index (ODI) and the Japanese Orthopaedic Association (JOA) score. VAS, ODI and JOA scores were compared between two groups before treatment and at 1, 3, 6, 9 and 12 months after treatment.
RESULTS:
All patients were followed up for 12 months. The VAS for the McKenzie combined with 3D printing group before treatment and at 1, 3, 6, 9, and 12 months post-treatment were(6.533±0.860), (5.133±1.008), (3.933±0.868), (2.900±0.759), (2.067±0.640), (1.433±0.504), respectively. In the McKenzie group, the corresponding scores were (6.467±0.860), (5.067±1.048), (4.600±0.968), (3.533±1.008), (2.567±0.728), (1.967±0.809), respectively. The ODI of the McKenzie group before treatment and at 1, 3, 6, 9, and 12 months post-treatment were (41.033±6.810)%, (37.933±6.209)%, (35.467±6.962)%, (27.567±10.081)%, (20.800±7.531)%, (13.533±5.158)%, respectively. For the McKenzie combined with 3D printing group, the corresponding ODI were(38.033±5.605)%, (33.000±6.192)%, (28.767±7.045)%, (22.200±5.517)%, (17.700±4.836)%, (11.900±2.771)%, respectively. The JOA scores of the McKenzie combined with 3D printing group before treatment and at 1, 3, 6, 9, and 12 months post-treatment were(8.900±2.074), (13.133±2.330), (15.700±3.583), (20.400±3.480), (22.267±3.084), (24.833±2.640), respectively. In the McKenzie group, the corresponding scores were(9.200±2.091), (12.267±2.406), (15.333±3.198), (18.467±2.240), (20.133±2.751), (22.467±2.849), respectively. Before the initiation of treatment, no statistically significant differences were observed in the VAS, ODI, and JOA scores between two groups (P>0.05). At 3, 6, 9, and 12 months post-treatment, the VAS in the McKenzie combined with 3D printing group was significantly lower than that in the McKenzie group, and the difference was statistically significant (P<0.05). The comparison of ODI between two groups at 1, 3, 6, 9, and 12 months post-treatment revealed statistically significant differences (P<0.05). At 6, 9, and 12 months post-treatment, the JOA score in the McKenzie combined with 3D printing group was significantly higher than that in the McKenzie-only group, and the difference was statistically significant (P<0.05).
CONCLUSION
The combination of 3D printed functional spinal external fixation brace with McKenzie therapy can significantly improve and maintain lumbar function in patients with LDH.
Humans
;
Male
;
Female
;
Middle Aged
;
Printing, Three-Dimensional
;
Intervertebral Disc Displacement/surgery*
;
External Fixators
;
Lumbar Vertebrae/surgery*
;
Adult
;
Braces
;
Treatment Outcome
2.Prognostic Significance of Endothelial Activation and Stress Index in Mantle Cell Lymphoma.
Xin-Yue ZHOU ; Zhi-Qin YANG ; Jin HU ; Feng-Yi LU ; Qian-Nan HAN ; Huan-Huan ZHAO ; Wen-Xia GAO ; Yu-Han MA ; Hu-Jun LI ; Zhen-Yu LI ; Kai-Lin XU ; Wei CHEN
Journal of Experimental Hematology 2025;33(4):1051-1056
OBJECTIVE:
To investigate the predictive value of endothelial activation and stress index (EASIX) for the prognosis of patients with mantle cell lymphoma (MCL).
METHODS:
A retrospective analysis was conducted to assess prognosis and compare the clinical features of patients diagnosed with MCL who were admitted to the Affiliated Hospital of Xuzhou Medical University from January 2010 to June 2023, had therapeutic indications and received standard treatment.
RESULTS:
A total of 66 patients were included and divided into high EASIX group and low EASIX group, according to a cutoff value of 0.97 determined by the receiver operating characteristic (ROC) curve. Multivariate Cox regression analysis showed that prealbumin <0.2 g/L, high EASIX, and ECOG PS score ≥2 were independent risk factors influencing overall survival (OS) in MCL patients. The median OS of patients in the high and low EASIX group was 13.0 and 37.5 months, and the median progression-free survival was 8.8 and 26.0 months, respectively. The proportions of patients with ECOG PS score ≥2 and prealbumin <0.2 g/L at onset significantly increased in the high EASIX group compared to those in the low EASIX group.
CONCLUSION
At the time of initial diagnosis, EASIX can serve as an independent prognostic indicator impacting OS in patients with MCL. Furthermore, patients in the high EASIX group experience a poorer prognosis and shorter survival duration compared with those in the low EASIX group.
Humans
;
Lymphoma, Mantle-Cell/pathology*
;
Prognosis
;
Retrospective Studies
;
Male
;
Female
;
Middle Aged
;
Aged
;
ROC Curve
3.Correlation between the Observer's Assessment of Alertness/Sedation score and bispectral index in patients receiving propofol titration during general anesthesia induction.
Lihong CHEN ; Huilin XIE ; Xia HUANG ; Tongfeng LUO ; Jing GUO ; Chunmeng LIN ; Xueyan LIU ; Lishuo SHI ; Sanqing JIN
Journal of Southern Medical University 2025;45(1):52-58
OBJECTIVES:
To explore the relationship between the Observer's Assessment of Alertness/Sedation (OAAS) score and the bispectral index (BIS) during propofol titration for general anesthesia induction and analyze the impact of BIS monitoring delay on anesthetic depth assessment.
METHODS:
This study was conducted among 90 patients (ASA class I-II) undergoing elective surgery under general anesthesia. For anesthesia induction, the patients received propofol titration at the rate of 0.5 mg·kg-1·min-1 till OAAS scores of 4, 3, 2, and 1 were reached. After achieving an OAAS score of 1, remifentanil (2 μg·kg⁻¹) and rocuronium (0.6 mg·kg⁻¹) were administered, and tracheal intubation was performed 2 min later. BIS values, mean arterial pressure (MAP), heart rate (HR), and propofol dosage at each OAAS score were recorded, and the correlation between OAAS scores and BIS values was analyzed. The diagnostic performance of BIS values for determining when the OAAS score reaches 1 was analyzed using ROC curve.
RESULTS:
All the patients successfully completed tracheal intubation. BIS values of the patients at each of the OAAS scores differed significantly (P<0.01), and the mean BIS value decreased by 4.08, 8.32, 5.43 and 5.24 as the OAAS score decreased from 5 to 4, from 4 to 3, from 3 to 2, and from 2 to 1, respectively. There was a significant correlation between the OAAS score and BIS values (ρ=0.775, P<0.001). The median BIS value for an OAAS score of 1 was 76, at which point 83.33% of the patients had BIS values exceeding 60. ROC curve analysis showed that for determining an OAAS score of 1, BIS value, at the optimal cutoff value of 84, had a sensitivity of 88.9%, a specificity of 73.3%, and an area under the curve of 0.842 (0.803-0.881).
CONCLUSIONS
OAAS score during induction of general anesthesia is strongly correlated with BIS value and is a highly sensitive and timely indicator to compensate for the delay in BIS monitoring.
Humans
;
Propofol/administration & dosage*
;
Male
;
Female
;
Middle Aged
;
Anesthesia, General/methods*
;
Adult
;
Consciousness Monitors
;
Aged
;
Young Adult
;
Monitoring, Intraoperative/methods*
;
Electroencephalography
4.Expert consensus on the prevention and treatment of enamel demineralization in orthodontic treatment.
Lunguo XIA ; Chenchen ZHOU ; Peng MEI ; Zuolin JIN ; Hong HE ; Lin WANG ; Yuxing BAI ; Lili CHEN ; Weiran LI ; Jun WANG ; Min HU ; Jinlin SONG ; Yang CAO ; Yuehua LIU ; Benxiang HOU ; Xi WEI ; Lina NIU ; Haixia LU ; Wensheng MA ; Peijun WANG ; Guirong ZHANG ; Jie GUO ; Zhihua LI ; Haiyan LU ; Liling REN ; Linyu XU ; Xiuping WU ; Yanqin LU ; Jiangtian HU ; Lin YUE ; Xu ZHANG ; Bing FANG
International Journal of Oral Science 2025;17(1):13-13
Enamel demineralization, the formation of white spot lesions, is a common issue in clinical orthodontic treatment. The appearance of white spot lesions not only affects the texture and health of dental hard tissues but also impacts the health and aesthetics of teeth after orthodontic treatment. The prevention, diagnosis, and treatment of white spot lesions that occur throughout the orthodontic treatment process involve multiple dental specialties. This expert consensus will focus on providing guiding opinions on the management and prevention of white spot lesions during orthodontic treatment, advocating for proactive prevention, early detection, timely treatment, scientific follow-up, and multidisciplinary management of white spot lesions throughout the orthodontic process, thereby maintaining the dental health of patients during orthodontic treatment.
Humans
;
Consensus
;
Dental Caries/etiology*
;
Dental Enamel/pathology*
;
Tooth Demineralization/etiology*
;
Tooth Remineralization
5.Developing a polygenic risk score for pelvic organ prolapse: a combined risk assessment approach in Chinese women.
Xi CHENG ; Lei LI ; Xijuan LIN ; Na CHEN ; Xudong LIU ; Yaqian LI ; Zhaoai LI ; Jian GONG ; Qing LIU ; Yuling WANG ; Juntao WANG ; Zhijun XIA ; Yongxian LU ; Hangmei JIN ; Xiaowei ZHANG ; Luwen WANG ; Juan CHEN ; Guorong FAN ; Shan DENG ; Sen ZHAO ; Lan ZHU
Frontiers of Medicine 2025;19(4):665-674
Pelvic organ prolapse (POP), whose etiology is influenced by genetic and clinical risk factors, considerably impacts women's quality of life. However, the genetic underpinnings in non-European populations and comprehensive risk models integrating genetic and clinical factors remain underexplored. This study constructed the first polygenic risk score (PRS) for POP in the Chinese population by utilizing 20 disease-associated variants from the largest existing genome-wide association study. We analyzed a discovery cohort of 576 cases and 623 controls and a validation cohort of 264 cases and 200 controls. Results showed that the case group exhibited a significantly higher PRS than the control group. Moreover, the odds ratio of the top 10% risk group was 2.6 times higher than that of the bottom 10%. A high PRS was significantly correlated with POP occurrence in women older than 50 years old and in those with one or no childbirths. As far as we know, the integrated prediction model, which combined PRS and clinical risk factors, demonstrated better predictive accuracy than other existing PRS models. This combined risk assessment model serves as a robust tool for POP risk prediction and stratification, thereby offering insights into individualized preventive measures and treatment strategies in future clinical practice.
Humans
;
Female
;
Pelvic Organ Prolapse/epidemiology*
;
Middle Aged
;
Risk Assessment/methods*
;
China/epidemiology*
;
Multifactorial Inheritance
;
Aged
;
Risk Factors
;
Genome-Wide Association Study
;
Genetic Predisposition to Disease
;
Case-Control Studies
;
Adult
;
Polymorphism, Single Nucleotide
;
Genetic Risk Score
;
East Asian People
6.Development of portable medical oxygen purity analyzer
Lin-Xia LI ; Jun-Bo GAO ; Rong FAN ; Ting WU ; Ya-Jiao XU ; Yan-Qi LIU ; Jin MA ; Yun-Ying WANG
Chinese Medical Equipment Journal 2024;45(3):36-40
Objective To develop a portable medical oxygen purity analyzer capable of real-time detection of multi-compo-nent gases in medical oxygen or aviation oxygen to ensure the safety of oxygen consumption.Methods The portable medical oxygen purity analyzer with STM3F103RC as the main controller involved in a management module,an oxygen detection module,a carbon monoxide/chlorine detection module,a flow/carbon dioxide detection module and a dew point detection module as its hardware components,which had its human-machine interface programmed with DGUS supervision,control and data acquisition(SCADA)software and system program developed with C language under Keil MDK environment.The performance verification of the analyzer developed was carried out in terms of oxygen detection error and stability and errors for measuring carbon monoxide,chlorine and carbon dioxide.Results The analyzer showed high precision when used to detect oxygen with high volume fraction,with long-term stability and the absolute error restrained within±0.1%;the erros for measuring carbon monoxide,chlorine and carbon dioxide were all limited within±5%FS to meet the desired requirements.Condusion The portable medical oxygen purity analyzer developed with high precision,stability and portability can be used for detection of medical oxygen and aviation oxygen.[Chinese Medical Equipment Journal,2024,45(3):36-40]
7.Development of low-oxygen mixed gas generator for pilot hypoxia testing
Lin-Xia LI ; Jia-Ling XU ; Guo-Yun MAO ; Yao-Xuan JI ; Jin MA ; Yun-Ying WANG
Chinese Medical Equipment Journal 2024;45(7):24-28
Objective To develop a low-oxygen mixed gas generator to make up for the deficiencies of low-pressure chambers and load-resistant hypoxia trainers during pilot hypoxia tolerance testing.Methods The device prepared the low-oxygen gas with the principle of gas separation,which was composed of a Sunsource OLF1100D-220AF air compressor,a SMC IDG75SAM4-03 filter,a buffer tank,an AIR Products PA3010 integrated assembly,a control box,sensors and regulators.The sensors included the pressure sensor,flow sensor,concentration sensor and dew point temperature sensor,and the control box consisted of a main control board,a power supply module,a transmission module,a communication module,a display and a housing.The embedded control software of the device was developed with KEIL 5 and C++.Results The device developed prepared the low-oxygen gas with the volume fraction being 4%to 18%and the maximum error of volume fraction being 0.05%,and the main components of the prepared gas met the technical requirements of medical oxygen as stipulated in GB 8982-2009 Oxygen supplies for medicine and aircraft breathing.Conclusion The low-oxygen gas prepared by the device has its volume fraction precisely controlled and can be used for hypoxia tolerance testing and acclimation training for pilots.[Chinese Medical Equipment Journal,2024,45(7):24-28]
8.Safety profile of tenofovir amibufenamide therapy extension or switching in patients with chronic hepatitis B: a phase Ⅲ multicenter, randomized controlled trial
Zhihong LIU ; Qinglong JIN ; Yuexin ZHANG ; Guozhong GONG ; Guicheng WU ; Lvfeng YAO ; Xiaofeng WEN ; Zhiliang GAO ; Yan HUANG ; Daokun YANG ; Enqiang CHEN ; Qing MAO ; Shide LIN ; Jia SHANG ; Huanyu GONG ; Lihua ZHONG ; Huafa YIN ; Fengmei WANG ; Peng HU ; Xiaoqing ZHANG ; Qunjie GAO ; Peng XIA ; Chuan LI ; Junqi NIU ; Jinlin HOU
Chinese Journal of Hepatology 2024;32(10):893-903
Objective:In chronic hepatitis B (CHB) patients with previous 96-week treatment with tenofovir amibufenamide (TMF) or tenofovir disoproxil fumarate (TDF), we investigated the safety profile of sequential TMF treatment from 96 to 144 weeks.Methods:Enrolled subjects that previously assigned (2:1) to receive either 25 mg TMF or 300 mg TDF with matching placebo for 96 weeks received extending or switching TMF treatment for 48 weeks. Safety profiles of kidney, bone, metabolism, body weight, and others were evaluated.Results:666 subjects from the initial TMF group and 336 subjects from TDF group with at least one dose of assigned treatment were included at week 144. The overall safety profile was favorable in each group and generally similar between extended or switched TMF treatments from week 96 to 144. In subjects switching from TDF to TMF, the non-indexed estimated glomerular filtration rate (by non-indexed CKD-EPI formula) and creatinine clearance (by Cockcroft-Gault formula) were both increased, which were (2.31±8.33) ml/min and (4.24±13.94) ml/min, respectively. These changes were also higher than those in subjects with extending TMF treatment [(0.91±8.06) ml/min and (1.30±13.94) ml/min]. Meanwhile, switching to TMF also led to an increase of the bone mineral density (BMD) by 0.75% in hip and 1.41% in spine. On the other side, a slight change in TC/HDL ratio by 0.16 (IQR: 0.00, 0.43) and an increase in body mass index (BMI) by (0.54±0.98) kg/m 2 were oberved with patients switched to TMF, which were significantly higher than that in TMF group. Conclusion:CHB patients receiving 144 weeks of TMF treatment showed favorable safety profile. After switching to TMF, the bone and renal safety was significantly improved in TDF group, though experienceing change in metabolic parameters and weight gain (NCT03903796).
9.Overview of the establishment of Shanghai twin birth cohort
Shan JIN ; Naisi QIAN ; Weixiao LIN ; Liping FANG ; Lei CHEN ; Bo FANG ; Tian XIA ; Chunfang WANG ; Huiting YU
Shanghai Journal of Preventive Medicine 2024;36(1):16-20
ObjectiveTo establish the Shanghai twin birth cohort (STBC) and analyze the effects of genetic factors, shared environment, and non-shared environment interactions on birth health and growth and development of newborns. MethodsBased on the population-wide birth cohort in Shanghai, a comprehensive survey was conducted on the families with double and multiple babies born after January 1, 2015 to collect information on birth health, growth and development, and the family environment of the babies. ResultsBy December 31, 2021, a total of 7 195 pairs (14 405 cases) of twins were successfully included in the STBC survey. The average birth length of twins was 47.2 cm and average birth weight was 2 465.3 g. Heterozygous twins accounted for 69.05% and preterm babies accounted for 57.07%. The average age of the mothers of twins was 31.82 years, and the average age of the fathers was 33.87 years, with more than 80% of the parents having a college degree or above. 44.50% of the mothers used assisted reproductive technologies, 7.40% had illnesses during pregnancy, and 15.90% were exposed to passive smoking during pregnancy. During the survey period, the average monthly increase in the length of the twin infants was 2.09 cm, and the average monthly weight gain was 0.53 kg. ConclusionThe incidence of adverse outcomes such as maternal cesarean section rate, preterm birth, and low birth weight is higher in the twin birth population. Information on birth health as well as growth and development in childhood and adolescence in the twin birth population is collected based on STBC, which can provide a solid data foundation for studying children’s chronic non-communicable diseases, psychological and behavioral disorders and other complex health problems caused by the combined effects of genetics and the environment.
10.The noise level in metro platforms and halls in a city
Xuebo HOU ; Xia ZHANG ; Yong NING ; Lin ZHANG ; Jianhui GAO ; Kai WANG ; Jin SU
Shanghai Journal of Preventive Medicine 2024;36(3):237-240
ObjectiveTo investigate the noise level and influencing factors in metro platforms and station halls, thereby providing the scientific basis for the establishment of hygienic standards. MethodsDuring the morning peak(7:00‒9:30)and off-peak (9:30‒17:00) on weekdays, the noise levels were measured with noise meters at 39 monitoring points of 13 station platforms and 31 monitoring points of 6 station halls. The monitoring points arrangement and detection methods referred to the Examination methods for public places—Part 1: physical parameters(GB/T 18204.1‒2013). ResultsThe measured noise level in the station ranged from 69.25 to 86.17 dB(A), accounting for 44.74% below 75 dB(A), 89.47% below 80 dB(A) and 97.37% below 85 dB(A).The noise level of the platform [(76.38±4.19) dB(A)] was higher than that of the station hall [(74.24±4.50) dB(A)](P<0.01). The noise level of the elevated platforms [(80.01±2.25) dB(A)] was higher than that of the underground platforms [(75.73±4.13) dB(A)](P<0.01), and the noise level of the platforms without platform screen doors(PSD) [(80.21±5.08) dB(A)] was higher than that of platforms with PSD[(74.73±3.16) dB(A)] (P<0.01). No statistical significant differences were observed among the different areas of the platforms, monitoring periods, platform depth, exit mode and operation years (P>0.05). ConclusionThe noise level in metro stations in the city does not fully meet the requirements of current relevant standards. It is suggested to take noise reduction measures to reduce the noise of metro stations.

Result Analysis
Print
Save
E-mail