1.TRIB3 promotes lung cancer cell survival and inhibits apoptosis through NRF2 activation
Jiao-jiao YU ; Cheng ZHANG ; Yu-jin XIANG ; Zhuo-wei HU ; Bing CUI ; Fang HUA
Acta Pharmaceutica Sinica 2021;56(5):1352-1359
The nuclear transcription factor nuclear factor erythroid 2-related factor 2 (NRF2) plays a crucial role in maintaining cellular redox homeostasis. The aberrant NRF2 signaling confers enhanced antioxidant capacity, which is linked to tumor progression and therapeutic resistance. The current study investigates the biological effects and molecular mechanism of tribbles homolog 3 (TRIB3), a stress-induced protein, in regulating cell survival and apoptosis in lung cancer. This study first performed the RNA sequencing data analysis with 576 lung adenocarcinoma patients from the cancer genome atlas (TCGA) database. The NRF2- antioxidant response element (ARE) signature was enriched in patients with high TRIB3 expression. Dual-luciferase reporter assay and real-time quantitative polymerase chain reaction (PCR) were used to confirm the effect of TRIB3 on the kelch-like ECH-associated protein-1 (KEAP1)-NRF2 pathway. Abrogation of
2.Correlation study of carotid artery stenosis and the degree of homocysteine in ischemic stroke patients
Yan JIAO ; Rong JIN ; Zonghua ZHANG ; Meng ZHAO ; Zheng CUI
International Journal of Biomedical Engineering 2015;38(2):91-94,后插5
Objective To study the relationship between the stenosis content of carotid artery and the degree of homocysteine (Hcy) by analyzing the level changes of Hcy in ischemic stroke patients.Methods One hundred and thirty patients of carotid artery stenosis with ischemic stroke were divided into four groups based on the degrees of carotid artery stenosis determined by ultrasound Doppler flow imaging:the slight stenosis group (32patients),the moderate group (35 patients),the severe group (33 patients) and the total occlusion group (30 patients).Meanwhile,30 healthy people were chosen as the control group.The levels of serum homocysteine (Hcy),total cholesterol (TC),triglyceride (TG) and low density lipoprotein (LDL) of each group were measured,and the results were compared with those of the control group.Results It was found that the serum Hcy level in ischemic stroke group were significantly higher than that in the control group (P<0.05),whereas the variations ofTC,TG,HDL and LDL levels between the ischemic stroke group and the control group could be neglected (P>0.05).An obviously increased order of serum Hcy levels was observed as the following,the control group,the slight stenosis group,the moderate group,the severe group as well as the total occlusion group.The difference between every two groups was statistically significant (P<0.05).The level of serum Hcy was positive correlated to the content of carotid artery stenosis (r=0.835,P<0.05).However,no correlation was found between the carotid artery stenosis and each level of TC,TG and LDL (r=0.031,0.012,0.018,respectively,P>0.05).Conclusions The serum Hcy level is closely related to the degree of carotid artery stenosis,and high level Hcy is suggested to be one of major risk factors for ischemic stroke.
4.Expression of autophagy related factors LC3 and Bnip-3 and apoptosis related factors Bcl-2 and Bax in brain tissue of experimental diabetic rats
Fan GAO ; Jin HU ; Xiaoli ZHANG ; Hong JIAO
Military Medical Sciences 2016;40(3):230-233
Objective To evaluate the effect of autophagy-related factors LC3 and Bnip-3 and apoptosis related factors Bcl-2 and Bax on brain damage in experimental diabetic rats .Methods Thirty SD rats were randomly divided into diabetic group and control group .The diabetic group was injected with 1% streptozotocin ( 60 mg/kg body mass ) and the control group with citrate buffer .The rats were sacrificed after 12 weeks feeding and brain tissues were obtained .Pathological chan-ges were observed and the expression of LC 3, Bnip-3, Bcl-2 and Bax in brain tissues of the rats was detected by immuno-histochemical SP method .Results Compared with the control group ,the diabetic rat brain pathology showed that the cell arrangment was more disorderly and distributed more unevenly , the cell body was smaller , cytoplasm was lighter red , and the number of nerve cells of normal morphology was smaller .The positive number of LC3, Bnip-3 and Bax in brain tissues of diabetic rats was significantly larger than in the control group ,and the difference was statistically significant (P<0.05). However ,the positive number of Bcl-2 was significantly smaller than in the control group ,and the difference was statistically significant (P<0.001).In diabetic rats, LC3 and Bnip-3 showed a weak positive correlation(P<0.05), Bcl-2 and Bax were irrelevant, Bnip-3 and Bax were positively weakly-correlated(P<0.05),Bcl-2 was not correlated;and Bcl-2 and Bax were irrelevant.Conclusion LC3,Bnip-3 and Bax in the brain tissue of diabetic rats are overexpressed , while Bcl-2 shows weak expression , indicating that autophagy factors and apoptotic factors are involved in the process of brain injury in diabet -ic rats, which may be one of the mechanisms of brain tissue damage .
5.The 1 000 Hz-Tympanometry of 47 Newborns Failed the Initial Hearing Screening
Jiao CUI ; Jinshan LU ; Jin ZHANG ; Liang TANG
Journal of Audiology and Speech Pathology 2013;(5):480-482
Objective To investigate the clinical characteristic of 1 000 Hz probe tone tympanometry obtained from neonates who didn’t pass the TEOAE screening . .Methods TEOAE screening were performed to screen the hearing with GSI -70 Automated OAE(Grason-Stadler ,USA) .Then neonates were detected the 1 000 Hz probe tone tympanograms by GSI Tympstar Version Ⅱ Middle Ear Analyzer(Grason-Stadler ,USA) .The relative infor-mation ,including tympanometric peak pressure (Tpp) ,peak admittance(Yp) ,peak compensated static acoustic ad-mittance (Ypc)、tympanometric width(TW) were collatea .The of 1 000 Hz probe tone tympanometry of 47 ears that didn’t pass the first TEOAE and 1 300 ears that passed the first TEOAE were asnpared .Results We found in the single-peak type ,the ratio of the experimental group(59 .57% ) was less than that of the control group(74 .00% ) , and in the flat type the ratio of the the experimental group (23 .40% ) was more than that of the control group (8 . 54% ) ,there was a statistical significance between the two groups in each different type proportion (P<0 .05) .But there is not a statistical significance in the relative values of single -peak type admittance between the two groups , such as tympanometric peak pressure (Tpp)、peak admittance(Yp) etc .Conclusion The majority of 1000Hz tympa-nograms of the neonates who passed TEOAE is the single -peak type ,but the neonates who didn’t pass the first TEOAE mostly shored the flat type The .
6.The safety and feasibility of dual axis rotational angiography for the diagnosis of coronary artery disease in aged Chinese patients
Jiao ZHANG ; Yuanyuan DUAN ; Zhigeng JIN ; Huiliang LIU
Journal of Interventional Radiology 2014;(9):757-761
Objective To evaluate the clinical safety and feasibility of dual-axis rotational coronary angiography (XperSwing) in diagnosing coronary artery disease in aged Chinese patients through comparing it with standard coronary angiography. Methods During the period from April 2011 to December 2012, a total of consecutive 151 patients with an age ≥ 65 years underwent diagnostic coronary angiography at authors’ hospital. The patients were randomly divided into the standard angiography group (n = 75) and XperSwing group (n = 76). The used dose of contrast, radiation exposure dose and operation time of each patient were recorded. Besides, the occurrence of procedure-related symptoms and arrhythmia during the procedure was recorded, and the blood pressure (BP), heart rate (HR) and creatinine level immediately before-and-after the procedure were estimated. The number of additional acquisition needed to be performed was used to evaluate the efficacy of the two methods. Results Coronary angiography was successfully accomplished in all patients of the two groups, and no significant difference in the number of additional acquisition existed between the two groups (P > 0.05). The used dose of contrast in XperSwing group was reduced by 44% when compared with that in the standard angiography group, i.e. (29.28 ± 5.06) ml vs(22 755.97 ± 11 239.22) mGycm2, (P<0.001). No statistically significant differences in the occurrence of procedure-related symptoms and arrhythmia during the procedure, in the operation time as well as in the postoperative changes of BP and HR existed between the two groups (P > 0.05). No contrast- induced nephropathy occurred in both groups, although the difference in postoperative changes of creatinine level between the two groups was statistically significant (P < 0.05). Conclusion This study indicates that in diagnosing coronary artery disease in aged Chinese patients, dual-axis rotational coronary angiography is more safe and effective than conventional coronary angiography, as XperSwing can significantly reduce the contrast dose and radiation exposure for the patients.
7.Evaluation of computerized image analysis system for quantification of posterior capsular opacification
Li-Wei, MA ; Jin-Song, ZHANG ; Jun, XU ; Jiao, ZHANG ; Ping, ZHAO
International Eye Science 2007;7(5):1213-1216
AIM: To set up and evaluate a computerized image scoring system for quantification of posterior capsular opacification (PCO) that is independent of examinee.METHODS: The PCO model was made in rabbits. Following dilation of the pupil (>6.5mm), standardized digital images of the PCO were obtained using slit-lamp photographic system(digital camera, computer included). PCO was scored by evaluating retroillumination photograghs. The PCO score was calculated by the formula: PCO score=∑ (OD×AI in CR)×2 +∑(OD×AI in OR), in which OD is opacity density (class 0 to 4),AI is the opacity area fraction, CR is the central region (diameter=3mm), OR is the outer region (3-6mm ring region).To evaluate the reliability of the scoring system, 6 examiners scored the pictures of 5 same eyes (interindividual reliability),and one examiner scored the pictures of 5 eyes on five different days (intraindividual reliability).RESULTS: The PCO scoring system was very reliable. With PCO score range from 0 to 1.5, the interindividual reliability showed standard deviation between 0.05-0.087. Kruskal-Wallis analysis showed no significant difference (H=0.314,P=0.9726). The intraindividual reliability showed standard deviation between 0.041-0.067, no significant difference either (H =0.613, P =0.9616).CONCLUSION: This PCO quantification analysis system evaluates the central area (diameter=6mm) of posterior capsule which is larger than visual acuity or other objective testing. The system revealed high reliability and insignificant investigator-dependent difference. With a standardized photographic setup, systematic errors by the photographic technique were not relevant. This system was proved to be an easy and useful tool to accurately evaluate PCO.
8.Application of microlecture in practice class of aerospace physiology
Lin ZHANG ; Bo JIAO ; Yungang BAI ; Jiuhua CHENG ; Zhibin YU ; Jin MA
Basic & Clinical Medicine 2017;37(9):1336-1339
Aerospace physiology is an important part of aerospace medicine.There are some problems existing in the current practice classes.Microlecture is a new kind of teaching methods.With its advantages, microlecture improved the teaching efficiency, and played a good role in the practice classes for undergraduate students, successfully solving part of the problems and promoting the teaching reform.The microlecture, as an auxiliary means, provides a new way for practice class of aerospace physiology.It`s suggested to be popularized in undergraduate teaching of aerospace medicine.
9.Determination of Uric Acid Based on Active Copper-Containing Carbon Nanodots-modified Electrochemical Biosensor
Hongying LIU ; Tengfei JIN ; Daxiang DAI ; Mingru JIAO ; Cheng HUANG ; Mingzhen ZHANG ; Chunchuan GU
Chinese Journal of Analytical Chemistry 2017;45(8):1103-1108
The active copper-containing carbon nanodots were prepared by hydrothermal method, and then characterized by fluorescence spectroscopy and UV-visible absorption spectroscopy.Subsequently, a highly sensitive and selective electrochemical biosensor was fabricated on the basis of this synthesized carbon nanodots with electro-deposition technique.The electrode behavior was investigated by cyclic voltammetry, electrochemical impedance spectroscopy, and differential pulse voltammetry.Furthermore, the catalysis mechanism was studied.The experimental results indicated that the biosensor exhibited a strong electrocatalytic activity toward the oxidation of uric acid (UA).What′s more, the interference from ascorbic acid and dopamine was eliminated effectively.Under the optimum conditions, there were linear relationships between the anodic peak current and the concentration of UA (1.00-300.0 μmol/L), and the limit detection was 0.30 μmol/L (S/N=3).The prepared biosensor had advantages such as easy fabrication, strong anti-interference ability, high sensitivity, and wide detection range, and could be used for real sample detection.
10.Percutaneous permeability of lidocaine hydrochloride loaded destran-based niosomes
Jiao NIU ; Dong ZENG ; Qin LI ; Sheng WANG ; Jin CHANG ; Yue WANG ; Lianyun ZHANG
Tianjin Medical Journal 2015;(4):353-355,449
Objective To study the percutaneous permeability through mouse skin of lidocaine hydrochloride-loaded destran-based niosomes(LID-HLD-BNs)in vitro and in vivo. Methods HPLC was employed to exam lidocaine hydrochlo?ride. Lidocaine hydro-chloride-loaded conventional liposomes (LID-CLs) and lidocaine hydrochloride injection (LID-IJ) were used as control. Isolated mouse skin was added into Franz diffusion cell to evaluate the permeability of LID-HLD-BNs in vitro. Confocal Laser Scanning Microscopy(CLSM)was used to observe the permeation depth of mouse skin in vivo. Re?sults The permeation rate and cumulative permeation amount were significantly higher in LID-HLD-BNs group than those of LID-CLs and LID-IJ groups (P<0.05). CLSM studies also confirmed that HLD-BNs reached deeper layers of the skin. Conclusion LID-HLD-BNs has good transdermal ability.