1.Safety and Efficacy of Pivot-Balloon for Severe Tricuspid Regurgitation:The First-in-Man Experiences
Eun Kyoung KIM ; Min-Ku CHON ; Hyun-Sook KIM ; Yong-Hyun PARK ; Sang-Hyun LEE ; Ki Seok CHOO ; Hyung Gon JE ; Dae-Hee KIM ; Tae Oh KIM ; Yoon Seok KOH ; Jae-Hyeong PARK ; Jae-Hwan LEE ; Young Jin CHOI ; Eun Seok SHIN ; Hyuck-Jun YOON ; Seung-Whan LEE ; Joo-Yong HAHN
Korean Circulation Journal 2025;55(1):20-31
Background and Objectives:
Among various emerging catheter-based treatments for severe tricuspid regurgitation (TR), the spacer device can reduce the regurgitation orifice without manipulating the valve leaflet. However, its clinical application has been hampered by traumatic anchoring to the myocardium and the coaxial alignment of the balloon resulting in insufficient TR reduction. This study aimed to evaluate the early-stage safety, technical feasibility, and preliminary efficacy of the novel atraumatic vertical spacer in patients with isolated severe TR.
Methods:
All procedures were guided by fluoroscopy and transthoracic echocardiography.The maximum device placement time with an inflated balloon was 24 hours. Changes in the amount of TR, right ventricular function, and patient hemodynamics were measured during balloon deployment.
Results:
A total of 7 patients (median age 74), underwent successful device implantation without procedure-related complications. During balloon inflation (median 25 minutes), there were no symptoms or signs indicative of TR intolerance. TR was reduced by 1 grade or greater in all patients, with 2 patients exhibiting a reduction of 3 grades, from torrential TR to a moderate degree. Mild TR after balloon inflation was achieved in 3 patients with baseline severe TR. The TR reduction observed during initial balloon deployment was sustained during the subsequent balloon maintenance period.
Conclusions
The Pivot-balloon procedure was safe, technically feasible, and effective in reducing TR in patients with severe TR. No periprocedural complications or adverse cardiovascular events were reported during device placement with TR reduction observed in all patients. However, longer-term follow-up is needed to confirm safety and treatment effect.
2.Safety and Efficacy of Pivot-Balloon for Severe Tricuspid Regurgitation:The First-in-Man Experiences
Eun Kyoung KIM ; Min-Ku CHON ; Hyun-Sook KIM ; Yong-Hyun PARK ; Sang-Hyun LEE ; Ki Seok CHOO ; Hyung Gon JE ; Dae-Hee KIM ; Tae Oh KIM ; Yoon Seok KOH ; Jae-Hyeong PARK ; Jae-Hwan LEE ; Young Jin CHOI ; Eun Seok SHIN ; Hyuck-Jun YOON ; Seung-Whan LEE ; Joo-Yong HAHN
Korean Circulation Journal 2025;55(1):20-31
Background and Objectives:
Among various emerging catheter-based treatments for severe tricuspid regurgitation (TR), the spacer device can reduce the regurgitation orifice without manipulating the valve leaflet. However, its clinical application has been hampered by traumatic anchoring to the myocardium and the coaxial alignment of the balloon resulting in insufficient TR reduction. This study aimed to evaluate the early-stage safety, technical feasibility, and preliminary efficacy of the novel atraumatic vertical spacer in patients with isolated severe TR.
Methods:
All procedures were guided by fluoroscopy and transthoracic echocardiography.The maximum device placement time with an inflated balloon was 24 hours. Changes in the amount of TR, right ventricular function, and patient hemodynamics were measured during balloon deployment.
Results:
A total of 7 patients (median age 74), underwent successful device implantation without procedure-related complications. During balloon inflation (median 25 minutes), there were no symptoms or signs indicative of TR intolerance. TR was reduced by 1 grade or greater in all patients, with 2 patients exhibiting a reduction of 3 grades, from torrential TR to a moderate degree. Mild TR after balloon inflation was achieved in 3 patients with baseline severe TR. The TR reduction observed during initial balloon deployment was sustained during the subsequent balloon maintenance period.
Conclusions
The Pivot-balloon procedure was safe, technically feasible, and effective in reducing TR in patients with severe TR. No periprocedural complications or adverse cardiovascular events were reported during device placement with TR reduction observed in all patients. However, longer-term follow-up is needed to confirm safety and treatment effect.
3.Safety and Efficacy of Pivot-Balloon for Severe Tricuspid Regurgitation:The First-in-Man Experiences
Eun Kyoung KIM ; Min-Ku CHON ; Hyun-Sook KIM ; Yong-Hyun PARK ; Sang-Hyun LEE ; Ki Seok CHOO ; Hyung Gon JE ; Dae-Hee KIM ; Tae Oh KIM ; Yoon Seok KOH ; Jae-Hyeong PARK ; Jae-Hwan LEE ; Young Jin CHOI ; Eun Seok SHIN ; Hyuck-Jun YOON ; Seung-Whan LEE ; Joo-Yong HAHN
Korean Circulation Journal 2025;55(1):20-31
Background and Objectives:
Among various emerging catheter-based treatments for severe tricuspid regurgitation (TR), the spacer device can reduce the regurgitation orifice without manipulating the valve leaflet. However, its clinical application has been hampered by traumatic anchoring to the myocardium and the coaxial alignment of the balloon resulting in insufficient TR reduction. This study aimed to evaluate the early-stage safety, technical feasibility, and preliminary efficacy of the novel atraumatic vertical spacer in patients with isolated severe TR.
Methods:
All procedures were guided by fluoroscopy and transthoracic echocardiography.The maximum device placement time with an inflated balloon was 24 hours. Changes in the amount of TR, right ventricular function, and patient hemodynamics were measured during balloon deployment.
Results:
A total of 7 patients (median age 74), underwent successful device implantation without procedure-related complications. During balloon inflation (median 25 minutes), there were no symptoms or signs indicative of TR intolerance. TR was reduced by 1 grade or greater in all patients, with 2 patients exhibiting a reduction of 3 grades, from torrential TR to a moderate degree. Mild TR after balloon inflation was achieved in 3 patients with baseline severe TR. The TR reduction observed during initial balloon deployment was sustained during the subsequent balloon maintenance period.
Conclusions
The Pivot-balloon procedure was safe, technically feasible, and effective in reducing TR in patients with severe TR. No periprocedural complications or adverse cardiovascular events were reported during device placement with TR reduction observed in all patients. However, longer-term follow-up is needed to confirm safety and treatment effect.
4.Safety and Efficacy of Pivot-Balloon for Severe Tricuspid Regurgitation:The First-in-Man Experiences
Eun Kyoung KIM ; Min-Ku CHON ; Hyun-Sook KIM ; Yong-Hyun PARK ; Sang-Hyun LEE ; Ki Seok CHOO ; Hyung Gon JE ; Dae-Hee KIM ; Tae Oh KIM ; Yoon Seok KOH ; Jae-Hyeong PARK ; Jae-Hwan LEE ; Young Jin CHOI ; Eun Seok SHIN ; Hyuck-Jun YOON ; Seung-Whan LEE ; Joo-Yong HAHN
Korean Circulation Journal 2025;55(1):20-31
Background and Objectives:
Among various emerging catheter-based treatments for severe tricuspid regurgitation (TR), the spacer device can reduce the regurgitation orifice without manipulating the valve leaflet. However, its clinical application has been hampered by traumatic anchoring to the myocardium and the coaxial alignment of the balloon resulting in insufficient TR reduction. This study aimed to evaluate the early-stage safety, technical feasibility, and preliminary efficacy of the novel atraumatic vertical spacer in patients with isolated severe TR.
Methods:
All procedures were guided by fluoroscopy and transthoracic echocardiography.The maximum device placement time with an inflated balloon was 24 hours. Changes in the amount of TR, right ventricular function, and patient hemodynamics were measured during balloon deployment.
Results:
A total of 7 patients (median age 74), underwent successful device implantation without procedure-related complications. During balloon inflation (median 25 minutes), there were no symptoms or signs indicative of TR intolerance. TR was reduced by 1 grade or greater in all patients, with 2 patients exhibiting a reduction of 3 grades, from torrential TR to a moderate degree. Mild TR after balloon inflation was achieved in 3 patients with baseline severe TR. The TR reduction observed during initial balloon deployment was sustained during the subsequent balloon maintenance period.
Conclusions
The Pivot-balloon procedure was safe, technically feasible, and effective in reducing TR in patients with severe TR. No periprocedural complications or adverse cardiovascular events were reported during device placement with TR reduction observed in all patients. However, longer-term follow-up is needed to confirm safety and treatment effect.
5.Caregiver Burden of Patients With Huntington’s Disease in South Korea
Chan Young LEE ; Chaewon SHIN ; Yun Su HWANG ; Eungseok OH ; Manho KIM ; Hyun Sook KIM ; Sun Ju CHUNG ; Young Hee SUNG ; Won Tae YOON ; Jin Whan CHO ; Jae-Hyeok LEE ; Han-Joon KIM ; Hee Jin CHANG ; Beomseok JEON ; Kyung Ah WOO ; Seong-Beom KOH ; Kyum-Yil KWON ; Jangsup MOON ; Young Eun KIM ; Jee-Young LEE
Journal of Movement Disorders 2024;17(1):30-37
Objective:
This is the first prospective cohort study of Huntington’s disease (HD) in Korea. This study aimed to investigate the caregiver burden in relation to the characteristics of patients and caregivers.
Methods:
From August 2020 to February 2022, we enrolled patients with HD from 13 university hospitals in Korea. We used the 12-item Zarit Burden Interview (ZBI-12) to evaluate the caregiver burden. We evaluated the clinical associations of the ZBI-12 scores by linear regression analysis and investigated the differences between the low- and high-burden groups.
Results:
Sixty-five patients with HD and 45 caregivers were enrolled in this cohort study. The average age at onset of motor symptoms was 49.3 ± 12.3 years, with an average cytosine-adenine-guanine (CAG)n of 42.9 ± 4.0 (38–65). The median ZBI-12 score among our caregivers was 17.6 ± 14.2. A higher caregiver burden was associated with a more severe Shoulson–Fahn stage (p = 0.038) of the patients. A higher ZBI-12 score was also associated with lower independence scale (B = -0.154, p = 0.006) and functional capacity (B = -1.082, p = 0.002) scores of patients. The caregiving duration was longer in the high- than in the low-burden group. Caregivers’ demographics, blood relation, and marital and social status did not affect the burden significantly.
Conclusion
HD patients’ neurological status exerts an enormous impact on the caregiver burden regardless of the demographic or social status of the caregiver. This study emphasizes the need to establish an optimal support system for families dealing with HD in Korea. A future longitudinal analysis could help us understand how disease progression aggravates the caregiver burden throughout the entire disease course.
6.Evaluating the Validity and Reliability of the Korean Version of the Scales for Outcomes in Parkinson’s Disease–Cognition
Jinse PARK ; Eungseok OH ; Seong-Beom KOH ; In-Uk SONG ; Tae-Beom AHN ; Sang Jin KIM ; Sang-Myung CHEON ; Yoon-Joong KIM ; Jin Whan CHO ; Hyeo-Il MA ; Mee Young PARK ; Jong Sam BAIK ; Phil Hyu LEE ; Sun Ju CHUNG ; Jong-Min KIM ; Han-Joon KIM ; Young-Hee SUNG ; Do Young KWON ; Jae-Hyeok LEE ; Jee-Young LEE ; Ji Seon KIM ; Ji Young YUN ; Hee Jin KIM ; Jin Yong HONG ; Mi-Jung KIM ; Jinyoung YOUN ; Hui-Jun YANG ; Won Tae YOON ; Sooyeoun YOU ; Kyum-Yil KWON ; Su-Yun LEE ; Younsoo KIM ; Hee-Tae KIM ; Joong-Seok KIM ; Ji-Young KIM
Journal of Movement Disorders 2024;17(3):328-332
Objective:
The Scales for Outcomes in Parkinson’s Disease–Cognition (SCOPA-Cog) was developed to assess cognition in patients with Parkinson’s disease (PD). In this study, we aimed to evaluate the validity and reliability of the Korean version of the SCOPACog (K-SCOPA-Cog).
Methods:
We enrolled 129 PD patients with movement disorders from 31 clinics in South Korea. The original version of the SCOPA-Cog was translated into Korean using the translation-retranslation method. The test–retest method with an intraclass correlation coefficient (ICC) and Cronbach’s alpha coefficient were used to assess reliability. Spearman’s rank correlation analysis with the Montreal Cognitive Assessment-Korean version (MOCA-K) and the Korean Mini-Mental State Examination (K-MMSE) were used to assess concurrent validity.
Results:
The Cronbach’s alpha coefficient was 0.797, and the ICC was 0.887. Spearman’s rank correlation analysis revealed a significant correlation with the K-MMSE and MOCA-K scores (r = 0.546 and r = 0.683, respectively).
Conclusion
Our results demonstrate that the K-SCOPA-Cog has good reliability and validity.
7.Establishment of a registry of clinical data and bioresources for rare nervous system diseases
Dayoung KIM ; Sooyoung KIM ; Jin Myoung SEOK ; Kyong Jin SHIN ; Eungseok OH ; Mi Young JEON ; Joungkyu PARK ; Hee Jin CHANG ; Jinyoung YOUN ; Jeeyoung OH ; Eunhee SOHN ; Jinse PARK ; Jin Whan CHO ; Byoung Joon KIM
Osong Public Health and Research Perspectives 2024;15(2):174-181
Rare diseases are predominantly genetic or inherited, and patients with these conditions frequently exhibit neurological symptoms. Diagnosing and treating many rare diseases is a complex challenge, and their low prevalence complicates the performance of research, which in turn hinders the advancement of therapeutic options. One strategy to address this issue is the creation of national or international registries for rare diseases, which can help researchers monitor and investigate their natural progression. In the Republic of Korea, we established a registry across 5 centers that focuses on 3 rare diseases, all of which are characterized by gait disturbances resulting from motor system dysfunction. The registry will collect clinical information and human bioresources from patients with amyotrophic lateral sclerosis, spinocerebellar ataxia, and hereditary spastic paraplegia. These resources will be stored at ICreaT and the National Biobank of Korea. Once the registry is complete, the data will be made publicly available for further research. Through this registry, our research team is dedicated to identifying genetic variants that are specific to Korean patients, uncovering biomarkers that show a strong correlation with clinical symptoms, and leveraging this information for early diagnosis and the development of treatments.
8.Safety and Efficacy of Everolimus-Eluting Bioresorbable Vascular Scaffold Versus Second-Generation Drug-Eluting Stents in Real-World Practice
Joo Myung LEE ; Hyun Sung JOH ; Ki Hong CHOI ; David HONG ; Taek Kyu PARK ; Jeong Hoon YANG ; Young Bin SONG ; Jin-Ho CHOI ; Seung-Hyuk CHOI ; Jin-Ok JEONG ; Jong-Young LEE ; Young Jin CHOI ; Jei-Keon CHAE ; Seung-Ho HUR ; Jang-Whan BAE ; Ju-Hyeon OH ; Kook-Jin CHUN ; Hyun-Joong KIM ; Byung Ryul CHO ; Doosup SHIN ; Seung Hun LEE ; Doyeon HWANG ; Hyun-Jong LEE ; Ho-Jun JANG ; Hyun Kuk KIM ; Sang Jin HA ; Eun-Seok SHIN ; Joon-Hyung DOH ; Joo-Yong HAHN ; Hyeon-Cheol GWON ; On behalf of the SMART-REWARD Investigators
Journal of Korean Medical Science 2023;38(5):e34-
Background:
The risk of device thrombosis and device-oriented clinical outcomes with bioresorbable vascular scaffold (BVS) was reported to be significantly higher than with contemporary drug-eluting stents (DESs). However, optimal device implantation may improve clinical outcomes in patients receiving BVS. The current study evaluated mid-term safety and efficacy of Absorb BVS with meticulous device optimization under intravascular imaging guidance.
Methods:
The SMART-REWARD and PERSPECTIVE-PCI registries in Korea prospectively enrolled 390 patients with BVS and 675 patients with DES, respectively. The primary endpoint was target vessel failure (TVF) at 2 years and the secondary major endpoint was patientoriented composite outcome (POCO) at 2 years.
Results:
Patient-level pooled analysis evaluated 1,003 patients (377 patients with BVS and 626 patients with DES). Mean scaffold diameter per lesion was 3.24 ± 0.30 mm in BVS group.Most BVSs were implanted with pre-dilatation (90.9%), intravascular imaging guidance (74.9%), and post-dilatation (73.1%) at proximal to mid segment (81.9%) in target vessel.Patients treated with BVS showed comparable risks of 2-year TVF (2.9% vs. 3.7%, adjusted hazard ratio [HR], 1.283, 95% confidence interval [CI], 0.487–3.378, P = 0.615) and 2-year POCO (4.5% vs. 5.9%, adjusted HR, 1.413, 95% CI, 0.663–3.012,P = 0.370) than those with DES. The rate of 2-year definite or probable device thrombosis (0.3% vs. 0.5%, P = 0.424) was also similar. The sensitivity analyses consistently showed comparable risk of TVF and POCO between the 2 groups.
Conclusion
With meticulous device optimization under imaging guidance and avoidance of implantation in small vessels, BVS showed comparable risks of 2-year TVF and device thrombosis with DES.
9.Validity and Reliability of the Korean-Translated Version of the International Cooperative Ataxia Rating Scale in Cerebellar Ataxia
Jinse PARK ; Jin Whan CHO ; Jinyoung YOUN ; Engseok OH ; Wooyoung JANG ; Joong-Seok KIM ; Yoon-Sang OH ; Hyungyoung HWANG ; Chang-Hwan RYU ; Jin-Young AHN ; Jee-Young LEE ; Seong-Beom KOH ; Jae H. PARK ; Hee-Tae KIM
Journal of Movement Disorders 2023;16(1):86-90
Objective:
The International Cooperative Ataxia Rating Scale (ICARS) is a semiquantitative clinical scale for ataxia that is widely used in numerous countries. The purpose of this study was to investigate the validity and reliability of the Korean-translated version of the ICARS.
Methods:
Eighty-eight patients who presented with cerebellar ataxia were enrolled. We investigated the construct validity using exploratory factor analysis (EFA) and confirmatory factor analysis (CFA). We also investigated the internal consistency using Cronbach’s α and intrarater and interrater reliability using intraclass correlation coefficients.
Results:
The Korean-translated ICARS showed satisfactory construct validity using EFA and CFA. It also revealed good interrater and intrarater reliability and showed acceptable internal consistency. However, subscale 4 for assessing oculomotor disorder showed moderate internal consistency.
Conclusion
This is the first report to investigate the validity and reliability of the Korean-translated ICARS. Our results showed excellent construct and convergent validity. The reliability is also acceptable.
10.Outcomes in Refractory Diffuse Large B-Cell Lymphoma: Results from Two Prospective Korean Cohorts
Jun Ho YI ; Seong Hyun JEONG ; Seok Jin KIM ; Dok Hyun YOON ; Hye Jin KANG ; Youngil KOH ; Jin Seok KIM ; Won-Sik LEE ; Deok-Hwan YANG ; Young Rok DO ; Min Kyoung KIM ; Kwai Han YOO ; Yoon Seok CHOI ; Whan Jung YUN ; Yong PARK ; Jae-Cheol JO ; Hyeon-Seok EOM ; Jae-Yong KWAK ; Ho-Jin SHIN ; Byeong Bae PARK ; Seong Yoon YI ; Ji-Hyun KWON ; Sung Yong OH ; Hyo Jung KIM ; Byeong Seok SOHN ; Jong Ho WON ; Dae-Sik HONG ; Ho-Sup LEE ; Gyeong-Won LEE ; Cheolwon SUH ; Won Seog KIM
Cancer Research and Treatment 2023;55(1):325-333
Purpose:
Diffuse large B-cell lymphoma (DLBCL) is the most common hematologic malignancy worldwide. Although substantial improvement has been achieved by the frontline rituximab-based chemoimmunotherapy, up to 40%-50% of patients will eventually have relapsed or refractory disease, whose prognosis is extremely dismal.
Materials and Methods:
We have carried out two prospective cohort studies that include over 1,500 DLBCL patients treated with rituximab plus CHOP (#NCT01202448 and #NCT02474550). In the current report, we describe the outcomes of refractory DLBCL patients. Patients were defined to have refractory DLBCL if they met one of the followings, not achieving at least partial response after 4 or more cycles of R-CHOP; not achieving at least partial response after 2 or more cycles of salvage therapy; progressive disease within 12 months after autologous stem cell transplantation.
Results:
Among 1,581 patients, a total of 260 patients met the criteria for the refractory disease after a median time to progression of 9.1 months. The objective response rate of salvage treatment was 26.4%, and the complete response rate was 9.6%. The median overall survival (OS) was 7.5 months (95% confidence interval, 6.4 to 8.6), and the 2-year survival rate was 22.1%±2.8%. The median OS for each refractory category was not significantly different (p=0.529).
Conclusion
In line with the previous studies, the outcomes of refractory DLBCL patients were extremely poor, which necessitates novel approaches for this population.

Result Analysis
Print
Save
E-mail