1.Effects of Intermittent Catheterization Methods on Detecting Urine Bacteria in Patients with Spinal Cord Injury
Meihong ZHU ; Xudong GU ; Yumei JIN ; Meifang SHI ; Mei JIN
Chinese Journal of Nosocomiology 2009;0(20):-
OBJECTIVE To investigate the influence of intermittent catheterization methods and indwelling catheterization methods on the urinary tract infection in patients with spinal cord injury.METHODS After eighty cases of spinal cord injury,the urine retention patients caused by bladder dysfunction were respectively used intermittent catheterization and indwelling catheterization.The urinary tract infection rates of regucally urine culture were compared.By use of intermittent catheterization,the bladder function was trained.Bacteria culture and identification of the urine from the patients were conducted after 15 or 30 days of intermittent catheterization and indwelling catheterization respectively.RESULTS The rates of urinary tract infection(colony count≥1?10 CFU/ml) after 15 or 30 days of intermittent catheterization were 32.6% and 31.5%,respectively.Which were significantly lower than those of indwelling catheterization(100%)(P
2.The establishment of hemodialysis access with long-term venous indwelling catheter under DSA guidance
Xuming BAI ; Yongbing SHI ; Mei TANG ; Xingshi GU ; Yong JIN
Journal of Interventional Radiology 2010;19(2):134-137
Objective To discuss the management, complication and effectiveness of establishing a prolonged hemodialysis access with a long-term venous indwelling catheter. Methods During the penod of July 2007-February 2009, a total of 64 long-term venous indwelling catheters for hemodialysis were placed in 62 patients with terminal chronic renal insufficiency. Results Of the total 64 catheter-placements, 62 were pereformed under DSA guidance and 2 at bed-side. Because of blocked flow, adjustment of the catheter was carried out in 4 cases, replacement of catheter in 2 cases and thrombolytic therapy in one case. In 62 patients, the arterial flow rate after the procedure reached to 230-300ml/min. In 57 cases the indwelling catheter remained in working condition so far. Five cases died within 6 months. Conclusion For establishing a prolonged hemodialysis access. The placement of a long-term venous indwelling catheter is feasible. The main complication is the blocked flow. Which is mainly related to the disposition of the catheter itself or its tip. The right intemal jugular vein is the indwelling site of choice, the tip of double-lumen catheter should be within the superior vein cava. With the help of DSA guidance, the procedure can be performed accurately, safely and easily.
3.Dynamic Change of Cerebral Blood Flow of Newborns with Hypoxic-Ischemic Encephalopathy
shi-qing, SHAO ; dong-mei, NING ; shu-fang, JIN
Journal of Applied Clinical Pediatrics 2004;0(12):-
Objective To observe the dynamic change of cerebral blood flow of newborns with hypoxic-ischemic encephalopathy(HIE).Methods Cerebral blood flow of middle cerebral artery and pulsatility index(PI) on 75 newborns with HIE and 50 normal infants were examined with transcranial doppler sonography at different time points,and the relations between cerebral blood flow and clinic indexes were analyzed.Results The blood velocity of normal infants increased gradually, and PI decreased from 2 to 5 days.The velocities were lower than that of normal infants,and PI was higher at 12th hour and 1st day, but during 2-5 days,the velocities got higher and PI got lower, in which the decrease of velocities correlated positively with Apgar scores and the increase of velocities were negatively correlative to Apgar scores.Compared with the neonates who had poor prognosis retrospectively with those had good prognosis, the velocity changes were found to be more significant.Conclusion The change of cerebral blood flow can show the pathophysiology of HIE and prognosticate the prognosis of neonates with HIE.
4.A case report of cerebral malaria combined with cyanotic congenital heart disease in a child and literature review
JIN Mei ; LIANG Juanjuan ; SHI Lei ; HE Fengxiao
China Tropical Medicine 2024;24(5):624-
Abstract: Malaria is one of the deadliest vector-borne infectious diseases in Africa, seriously endangering human life and health. Among them, cerebral malaria (CM) has a higher morbidity and mortality rate in children, with clinical manifestations primarily involving neurological symptoms, and comprehensive treatment mainly using artemisinin derivatives. When children with cerebral malaria are complicated by congenital heart disease and induce acute hypoxic attacks, the diagnosis and treatment face great difficulties in the absence of effective examination and monitoring treatments. Similar cases have rarely been reported at home and abroad. The paper summarizes and reports a case of a child with cerebral malaria combined with cyanotic congenital heart disease, treated during an aid mission to Africa, who was improved and discharged from the hospital after receiving multidisciplinary anti-malarial, intracranial pressure lowering, neurotrophic and symptomatic supportive treatment. This paper also discusses the diagnosis and treatment process of this child under difficult conditions, combined with current literature reports, in hopes of providing a reference for clinical treatment.
5.Comprehensive rehabilitation intervention for stroke patients with unilateral spatial neglect
Xudong GU ; Meihong ZHU ; Meifang SHI ; Jianmin FU ; Yunhai YAO ; Mei JIN ; Minmin JIN ; Meixia YANG
Chinese Journal of Physical Medicine and Rehabilitation 2009;31(3):177-180
Objective To observe the iffectiveness of comprehensive rehabilitationinterventions on stroke patients with unilateral spatial neglect (USN). Methods A total of 245 cases if strijd were examined to diagnose USN. Of the 245 patients,86 cases were diagnosed as being with USN, and divided into a control group(n=43 cases) and a treatment group (n=43 cases) randomly. The control group was treated with Bobath and Rood techniques in addition to routine clinical medical interventions, while the treatment group was treated with a comprehensive rehabilitation protocol for USN in addition to the same interventions for the control group. Both groups were assessed with regard to motor, balance function, walking performance, and USN severity as well as the activities of daily living (ADL) performance. Results After 8 weeks of treatment,both groups improved, but there showed a significantly statistical difference between the 2 groups in terms of Fugl-Meyer motor function scores (P<0.01), balance function scores (P<0.01) Holden walding function classifications (P<0.01), Barthel index(P<0.001) and USN severity scores(P<0.01). Conclusion Comprehensive USN rehabilitation intervention could improve motor, balance, walking functions and ADL performance and alleviate the USN severity in stroke patients with USN.
6.Repeatability and reproducibility of retinal straylight measurement using C-Quant compensation comparison method
Jin-hai, HUANG ; Shi-shi, LIN ; Qin-mei, WANG ; Bo, ZHENG ; Si-si, CHEN ; Rong-rong, GAO
Chinese Journal of Experimental Ophthalmology 2012;30(2):160-163
BackgroundIn an ideal eye there would be no light scattering at all,but the eye media is not optically ideal.Intraocular straylight causes a veil of light and reduction in the contrast of the retinal image and thus decrease the quality of vision.ObjectiveThe present study was to investigate the repeatability and reproducibility of C-Quant straylight meter( Oculus,Germany)in measuring retinal straylight of myopia and post-laser in situ keratomileusis(LASIK) corneas.MethodsThis is a prospective research.The consecutive 35 eyes of 21 myopic patients and 34 eyes of 22 patients who received LASIK were included in this trail.Retinal straylight was measured for 7 times at a period of time and analyzed quantificational to evaluate the repeatability of measurement.Thirty-eight eyes of 19 patients were measured again at 3-7 days for 3 times at a period of time to assess the reproducibility of C-Quant straylight meter.The mean standard difference (SD) and coefficient of variation (CV) were used as the credibility evaluation.This clinical study complied with Helsinki Declaration and the informed consent was obtained prior to the medical procedure.ResultsThe straylight Log(s) of 7 times measurement were all less than 0.95.The mean Log(s) were 0.92±0.12 and 0.93±0.17 respectively in myopia group and post-LASIK group,without statistically significant differences among 7 times measurement( F=0.335,P=0.812;F=1.000,P=0.409).The mean SD for the 7 times measurement was 0.07 Log units.SD and CV increased with the number of measurements.The differences of mean SD and CV between 3 times result and 6 times result were significant different (t =-2.080,P =0.045;t =-2.190,P =0.035 ).No difference was found between different time periods( t =-0.531,P=0.598 ).The difference of the results between two measurements from the same patient was 0.013.ConclusionsC-Quant is a noncontact,noninvade,rapid and convenient method for the measurement of straylight in myopia and post-LASIK eyes due to the high repeatability and reproducibility.
7.Comparison of anterior chamber depth and central corneal thickness measuring values between Sirius and Pentacam
Yan, LI ; Shi-ming, CHENG ; Xin, YANG ; Jin-hai, HUANG ; Qin-mei, WANG
Chinese Journal of Experimental Ophthalmology 2012;30(3):262-265
Background Biometry of the anterior ocular segment parameter is very important for the diagnosis and treatment of glaucoma and ocular injury as well as measurement of intraocular lens(IOL).Objective This study was to compare the differences in the anterior chamber depth(ACD) and the central corneal thickness (CCT) between Sirius and Pentacam and evaluate the agreement of these two measurement methods.Methods The ACD and the CCT of 38 right eyes from 38 health volunteers aged 23- 32 years were measured with both Pentacam and Sirius.Three times of measurement were pedormed on each eye for each method to obtain the average values.The repeatability and agreement from each method were assessed as intraclass correlation coefficient( ICC ) and coefficient of variation(CV) and the agreement between these two methods were evaluated using Bland-Altman mode.ResultsThe mean ACD value was( 3.18±0.21 ) mm from Pentacam with the ICC 0.995 and CV 0.066.The mean ACD value from Sirius was (3.22 ±0.21 )mm with the ICC 0.996 and CV 0.065.The difference value in ACD between two methods was 0.04 mm,showing a significant difference( t =-6.225,P<0.05 ) and a positive correlation (r=0.977) between two methods.The 95% limit of agreement was( -0.04-0.13)mm within 1 standard difference (SD) of the mean value( ±0.21mm),which was acceptable for clinical measurement.The CCT was( 535±33 )μm from Pentacam with the ICC 0.994 and CV 0.062.The CCT was(537±36)pm from Sirius with the ICC 0.999 and CV 0.067.The difference value in the CCT between two methods was about 2 μm,presenting a in significant difference ( t =1.771,P>0.05 ) and positive correlation ( r =0.985 ).The 95 % limit of agreement was ( - 11.64-15.65 ) μm within 1 SD of the mean value( ±34.27 pm),which was acceptable for clinical measurement.ConclusionsSirius and Pentacam show good agreement in the measurement of ACD and CCT.The two methods offer an alternative choice for the biological measurement of the anterior ocular segment.
8.Comparison of axial length and anterior chamber depth measurements by IOLMaster, Axis- Ⅱ A-scan and ODM 1000A sonograph
Shi-ming, CHENG ; Jin-hai, HUANG ; Yan, LI ; Xin, YANG ; Qin-mei, WANG
Chinese Journal of Experimental Ophthalmology 2011;29(11):1023-1026
Background Axial length and anterior chamber depth are important parameters for the calculation of diopter of intraocular lens ( IOL ). Objective This study was to investigate and compare the measuring outcomes of axial length and anterior chamber depth with IOLMaster,Axis- Ⅱ A-scan and ODM 1000A sonograph.Methods This a observational study.Axial length and anterior chamber depth were measured in 83 eyes of 48 patients with IOLMaster,Axis-Ⅱ A-scan and ODM 1000A sonograph by the same operator.The measuring results were compared among the three methods.Results The axial length were(25.79±0.85) mm,(25.72± 0.82 )mm and ( 26.00 ±0.83 )mm respectively with Axis- Ⅱ,ODM 1000A sonograph and IOLMaster.The difference between Axis-Ⅱ and DM 1000A sonograph was (0.07 ± 0.35 )mm without statistical difference between them (t=1.711,P =0.091 ).The difference of axial length between IOLMaster and DM 1000A sonograph was ( 0.27 ±0.29) mm with a statistical difference between them ( t =-8.570,P =0.000 ).The difference between IOLMaster and Axis- Ⅱ was (0.21 ±0.32 ) mm and showed a statistical difference ( t =- 5.931,P < 0.01 ).The positive correlations were found in the axial length values by the each other comparison among the three instruments( r=0.916,0.938,0.928,P<0.01 ).The anterior chamber depth values were ( 3.81 ±0.21 ) mm,( 3.84 ±0.25 ) mm and ( 3.83 ±0.18 )mm respectively with Axis-Ⅱ,0DM 1000A sonograph and IOLMaster.The difference of anterior chamber depth between Axis- Ⅱ and DM 1000A was (0.03 ±0.17 ) mm without statistical difference between them ( t =- 1.324,P =0.189 ).The difference in the anterior chamber depth between IOLMaster and DM 1000A was (0.01 ±0.15 ) mm and that between IOLMaster and Axis-Ⅱ was( 0.01 ±0.12)mm without any statistical differences among them (t =0.815,P=0.417 ;t=-0.900,P=0.371 ).The high correlation between anterior chamber depth measurements were found by the each other comparison in the three instruments ( r =0.735,0.813,0.823,P < 0.01 ).Conclusions ODM 1000A sonograph can provide precise axial length and anterior chamber depth values.However,ODM 1000Asonograph can not substitute for IOLMaster in the measurement of the anterior chamber depth and axial length.
9.Comparison among different noncontact specular microscopes for the detection of corneal endothelial cell density
Shi-ming, CHENG ; Jin-hai, HUANG ; Yan, LI ; Xin, YANG ; Rong-rong, GAO ; Qin-mei, WANG
Chinese Journal of Experimental Ophthalmology 2012;30(2):150-154
Background Clinical research showed that the corneal endothelial cell density value from different corneal specula microscopies exist diversity.The relevant literature of SP02,Tomey EM-3000 and SP3000P is still seldom up to now. Objective This research was to assess the repeatability of endothelial cell density measurements by SP02,Tomey EM-3000 and SP3000P respectively and the agreement among 3 kinds of endothelial microscopes.MethodsFifty-four healthy volunteers with the age 17-38 years old were included this research.The written informed consent was obtained from each subject before examination.The corneal endothelial cell densities in the right eyes were analyzed with SP02,Tomey EM-3000 and SP3000P respectively for 3 times under the automatic mode,and the analytical procedure of SP3000P measurement were divided into automatic mode SP3000P (A) and manual correction modes SP3000P( M).The repeatability of each specula microscopy was analyzed by calculating the intraclass correlation coefficients (ICC) and coefficient of variation ( CV ),and the 95% confidence intervals and plotting Bland-Altman graphs were used to analyze the agreement among these methods.ResultsThe mean corneal endothelial cell densities in the population <24 years were significantly higher than the ones ≥ 24 years (t =3.692,P<0.05 ),but no statistical difference was found between different gender ( t =0.335,P =0.739 ).The mean corneal endothelial cell densities were ( 3058 ± 260 ),( 2954 ± 229 ),( 2668 ± 258 ),( 2734 ± 268 ) cell/mm2 ; the ICCs were 0.957,0.940,0.972 and 0.972 and the CV were 0.063,0.061,0.056,0.058 for SP02,Tomey EM-3000,SP3000P (A) and SP3000P ( M ) respectively.The 95% confidence intervals were ( - 100.8 - 306.8 ),( 162.6 - 617.4 ),( 109.9-494.1 ) and ( -0.6 - 132.6 ) cell/mm2 for between SP02 and Tomey EM-3000,SP3000P ( A ) and SP02,SP3000P(A) and Tomey EM-3000,SP3000P(A) and SP 3000P(M) respectively.ConclusionsSP02,Tomey EM-3000 and SP3000P(A) have good repeatability in the measurement of corneal endothelial cell density,however the outcome is different.Therefore,it is not interchangeable for the detection of corneal endothelial cell density.The differences of corneal endothelial cell density obtained from these instruments shall be paid high attention for their differences.SP3000P(A) and SP3000P(M) can be used interehangeably and SP3000P(A) is a preferable choice due to its convenience and quickness.
10.Comparison of anterior segment measuring parameters in myopia after laser in situ keratomileusis between Sirius and Pentacam
Zhen, XU ; Jin-hai, HUANG ; Shi-ming, CHENG ; Yi-fan, FENG ; Qin-mei, WANG
Chinese Journal of Experimental Ophthalmology 2013;(6):572-577
Background Sirius system,a new Scheimpflug camera combined with Placido topography,improved the capability of imaging the anterior eye segment significantly.However,the study of assessing the repeatability and agreement between Sirius and Pentacam is still lack up to now.Objective This study was to evaluate the repeatability and agreement of the anterior ocular segment measuring parameters by Sirius and Pentacam in myopia received laser in situ keratomileusis (LASIK).Methods Thirty-five myopic eyes of 35 patients received LASIK were included in School of Optometry and Ophthalmology Eye Hospital from 2010 May through 2010 July.Corneal power flat keratometry (Kf),step keratometry (Ks),mean keratometry (Km),thinnest corneal thickness(TCT),the location of TCT,anterior chamber depth (ACD) and anterior chamber volume (ACV) were measured by Sirius and Pentacam in all the eyes,respectively.The repeatability of the measuring results were evaluated using intraclass correlation coefficients (ICC) and Cronbach's coefficient alpha (CoA),and the agreement of measuring parameters between Sirius and Pentacam was analyzed using Bland-Altman plot.Results Both Sirius and Pentacam demonstrated high intraobserver repeatability,with all ICC and CoA more than 0.90.No significant differences were found in Kf values and Ks values between the two methods (t =-1.533,-1.750,P>0.05).Km value was (39.14 ± 1.95) D by Sirius measurement,which was sígnificantly higher than (39.05 ± 1.91) D by Pentacam measurement (t =3.572,P =0.001).The TCT was (457.6 ± 40.9) μm by Sirius method,showing a significant reduce in comparison with (465.4±37.5) μm of Pentacam method (t =-6.689,P<0.001).A positive correlation was seen in the TCT between the two methods (r=0.988,P<0.001).The Bland-Alrman plots showed the 95% CI-21 μm to 6 pm in the TCT value between the two devices.Pairwise comparison of the location of TCT measurements showed significant differences between the two devices (t =-4.132,-5.696,P<0.001),with a good correlation (r=0.751,0.775) and the 95% CI (-0.36-0.17 mm,-0.35-0.12 mm).A very good agreement was seen in ACD between the two devices (-0.02-0.12 mm),but the agreement result was not very well in the ACV between the two devices with the 95% CI (-27.70-6.20 mm3).Conclusions Sirius and Pentacam measurements for anterior ocular segment parameters have a very good repeatability in post-LASIK eyes.In addition,good agreement results are exhibited in corneal power,TCT and ACD between Sirius and Pentacam with an acceptable maximal different value between them.Sirius and Pentacam can be used interchangeably in clinical examination.However,the two devices can not interchangeably for ACV measurement and TCT location.