1.Nevus Comedonicus Associated with Epidermal Cyst.
Bo Kyung KIM ; Jin Wook LEE ; Sung Ku AHN
Korean Journal of Dermatology 2015;53(4):338-341
No abstract available.
Epidermal Cyst*
;
Nevus*
2.Nevus Comedonicus Associated with Epidermal Cyst.
Bo Kyung KIM ; Jin Wook LEE ; Sung Ku AHN
Korean Journal of Dermatology 2015;53(4):338-341
No abstract available.
Epidermal Cyst*
;
Nevus*
3.A case of cutaneous metastasis from carcinoma of the urinary bladder.
Sung Ku AHN ; Jin Hyong WON ; Ho KWACK ; Seung Hun LEE ; Sungnack LEE
Korean Journal of Dermatology 1991;29(2):271-274
A 70 year-old male visited with 1 month history of dark brown, hard, non-movable subcutaneous nodule on the anterior chest. Histopathologic findings were compatible with the metastatic transitional cell carcinoma of the urinary bladder.
Aged
;
Carcinoma, Transitional Cell
;
Humans
;
Male
;
Neoplasm Metastasis*
;
Thorax
;
Urinary Bladder*
4.A case of rifampicin induced thrombocytopenic purpura.
Jin Hyoung WON ; Won HUR ; Sung Ku AHN ; Seung Hun LEE ; Kyung Joo LEE
Korean Journal of Dermatology 1991;29(6):817-821
No abstract available.
Purpura, Thrombocytopenic*
;
Rifampin*
5.A Case of Congenital Arteriovenous Fistula at Left Subclavian Artery Accompanied by Notching on Superior Aspect of Rib.
Ick Mo CHUNG ; Seung Yun CHO ; Seung Jung PARK ; Woong Ku LEE ; Jin Suk SEO
Korean Circulation Journal 1989;19(1):139-145
High output heart failure due to congenital arteriovenous fistula is a rare disease and is difficult to treat. A 27 year old man, suffering from dyspnea, palpitation, lower extremity edema, and abdominal distension admitted May, 1987. At admission there were continuous thrill and bruit at left supraclavicular and infraclavicular area. The heart sound was irregular and rapid, and grade IV/VI pansystolic murmur was audible at the apex. Chest PA showed marked cardiomegaly with pleural effusion and notching at superior aspect of left 2nd rib. Selective left subclavian artery angiogram showed extensive congenital arteriovenous fistula at the area of left subclavian artery and its branches. After setrial feeding artery embolization and palliative operation, the fistula size decreased much with clinical improvement.
Adult
;
Arteries
;
Arteriovenous Fistula*
;
Cardiomegaly
;
Dyspnea
;
Edema
;
Fistula
;
Heart Failure
;
Heart Sounds
;
Humans
;
Lower Extremity
;
Pleural Effusion
;
Rare Diseases
;
Ribs*
;
Subclavian Artery*
;
Thorax
6.Verruca Vulgaris Developed on the Skin Tag.
Jin Hyoung WON ; In Hwan NAM ; Seung Hun LEE ; Sung Ku AHN ; Joong Gie KIM
Annals of Dermatology 1994;6(1):105-107
Skin tags are very common skin tumors in middle age. In spite of their frequent occurrence, there was no reported cases of verruca vulgaris developing on the soft fibroma. We report a case of verruca vulgaris developing on the bag-like skin tag. We think that the incidence of HPV infection on the large skin tags may be higher than on normal skin due to their protrusion and repetitive irritation.
Fibroma
;
Humans
;
Incidence
;
Middle Aged
;
Skin*
;
Warts*
7.A study on in vitro developmental promoting effect of pronucleate I-cell mouse embryos by human amniotic fluid.
Ku Min CHUNG ; Shin Yong MOON ; Jin Yong LEE ; Yoon Seok CHANG
Korean Journal of Fertility and Sterility 1991;18(2):173-179
No abstract available.
Amniotic Fluid*
;
Animals
;
Embryonic Structures*
;
Female
;
Humans*
;
Mice*
8.Comparative Measurement of Skin Surface Hydration Using a Hydrometer and Corneometer.
Seung Hun LEE ; Joon CHUNG ; Sung Ku AHN ; Jin Soo KANG ; Oh Kyu KWON
Korean Journal of Dermatology 1994;32(4):599-608
BACKGROUND: Hydration, the water content of the stratum corneum, is an important factor in both the appearance and the barrier function of the skin. Many non-invasive methods have been developed in order to assesa the hydration state of the skin and the effect of various moisturizers. The hydrometer and carneometer are commercially available instruments which are widely used in dermatologic research. OBJECTIVE: Our purpose was to compare the measuring usefulnes of both instruments on normal subjects with a wide range of hydration states of the hornylayer. METHODS: We measured the conductance with the hydrometer and the capacitance with the corneometer in various hydrating eonditions and compared both insruments. RESULTS: Conductance had a non linear correlation with capacita ice. Capacitance measured with the corneometer had a high sensitivity to moisture in a wide range of hydration levels. On the other hand, conductance guaged with the hydrometer showed a few sensitivity to moisture at a low level. When the hydretion level was measured after a moiturizer was added, 10 % urea cream showed a sharp increase by 256% in terms of conductanae, and H-base by 97.8%. Mineral oil decreased by 41.5% and petrolatum by 62% respectively. On the other hand, when measured in terms of capacitance under the same conditions as above, 38.9 increase in 10% urea cream, 19.3% increase in H-base, 20% decrease in mineral oil, and 43.5 % decrease in petrolatum were reported. Conductance showed a higher hygroscopicity and a lower water holding capacity than capacitance did. When the measurement of the moisture level iri virious parts of the human body is performed, the corneometer provided us with more stable alies than the hydrometer. While the hydrometer can not the available and appropriate under the condition of insulation, the corneometer can measure moisture levels even down at the depth of 250mm. When measured after the oily surface of the forehead was cleansed with soft tissue, conductance and capacitance revealed higher values of moisture levels than before the eleanin. However, there is no statistical significance in these values. CONCLUSION: The hydrometer is a more appropriate tool for the measurement of moisture at a high level, and the corneometer at a low moisture level. The hydrcmeter is a more sensitive method of measuring the increase and the decrease in the moisture level.
Forehead
;
Hand
;
Human Body
;
Ice
;
Lasers, Gas
;
Mineral Oil
;
Petrolatum
;
Skin*
;
Urea
;
Water
;
Wettability
9.Comparative Measurement of Skin Surface Hydration Using a Hydrometer and Corneometer.
Seung Hun LEE ; Joon CHUNG ; Sung Ku AHN ; Jin Soo KANG ; Oh Kyu KWON
Korean Journal of Dermatology 1994;32(4):599-608
BACKGROUND: Hydration, the water content of the stratum corneum, is an important factor in both the appearance and the barrier function of the skin. Many non-invasive methods have been developed in order to assesa the hydration state of the skin and the effect of various moisturizers. The hydrometer and carneometer are commercially available instruments which are widely used in dermatologic research. OBJECTIVE: Our purpose was to compare the measuring usefulnes of both instruments on normal subjects with a wide range of hydration states of the hornylayer. METHODS: We measured the conductance with the hydrometer and the capacitance with the corneometer in various hydrating eonditions and compared both insruments. RESULTS: Conductance had a non linear correlation with capacita ice. Capacitance measured with the corneometer had a high sensitivity to moisture in a wide range of hydration levels. On the other hand, conductance guaged with the hydrometer showed a few sensitivity to moisture at a low level. When the hydretion level was measured after a moiturizer was added, 10 % urea cream showed a sharp increase by 256% in terms of conductanae, and H-base by 97.8%. Mineral oil decreased by 41.5% and petrolatum by 62% respectively. On the other hand, when measured in terms of capacitance under the same conditions as above, 38.9 increase in 10% urea cream, 19.3% increase in H-base, 20% decrease in mineral oil, and 43.5 % decrease in petrolatum were reported. Conductance showed a higher hygroscopicity and a lower water holding capacity than capacitance did. When the measurement of the moisture level iri virious parts of the human body is performed, the corneometer provided us with more stable alies than the hydrometer. While the hydrometer can not the available and appropriate under the condition of insulation, the corneometer can measure moisture levels even down at the depth of 250mm. When measured after the oily surface of the forehead was cleansed with soft tissue, conductance and capacitance revealed higher values of moisture levels than before the eleanin. However, there is no statistical significance in these values. CONCLUSION: The hydrometer is a more appropriate tool for the measurement of moisture at a high level, and the corneometer at a low moisture level. The hydrcmeter is a more sensitive method of measuring the increase and the decrease in the moisture level.
Forehead
;
Hand
;
Human Body
;
Ice
;
Lasers, Gas
;
Mineral Oil
;
Petrolatum
;
Skin*
;
Urea
;
Water
;
Wettability
10.A Case of Congenital Solitary Morphea Profunda.
Hyung Jin AHN ; Eung Ho CHOI ; Sung Ku AHN ; Sang Min HWANG ; Sung Hun LEE
Annals of Dermatology 2000;12(4):306-309
A 4-year-old boy has had a solitary sclerotic depressed plaque on the right anterior chest since birth. The histopathologic findings are consistent with morphea profunda: thickening, hyalinization, and homogenization of collagen bundles in the dermis and subcutaneous tissues, admixture with a prominent lymphocytic and plasma cell infiltrate, and sweat glands en-trapped between the thickened collagen bundles. We report a case of congenital solitary morphea profunda.
Child, Preschool
;
Collagen
;
Dermis
;
Humans
;
Hyalin
;
Male
;
Parturition
;
Plasma Cells
;
Scleroderma, Localized*
;
Subcutaneous Tissue
;
Sweat Glands
;
Thorax