1.Clinical Considerations of Intoxication Caused by a Herbicide Containing Glufosinate Ammonium: 6 Cases Analysis.
Ji Hun KANG ; Young Ho JIN ; Jae Baek LEE
Journal of the Korean Society of Emergency Medicine 1998;9(4):652-658
Basta(R) is one of the Phospho-amino acid group herbicide. It consist of glufosinate ammonium (18.5%), alkylether sulfate as surfactant (30%) and some solvents. Although it's WHO classification is Bade III, the intoxicated patient appears an serious clinical findings and have a 20% mortality rate. Nowadays, in Korea the ingestion of herbicidal agents for suicidal attempts is Sequent. The literature for intoxication of bipyridilium (Gramoxon(R)) as herbicide is varied, but the information for Basta(R) is poor even though the use of it tends to increase. Recently, We experienced six cases of Basta(R) intoxication and found that the patient expressed a gradually progressed depression of mentation, recent memory disturbances, convulsions, hypotension, or bradycardia because of CNS or cardiovascular effects of Basta(R) We report these cases with literature review.
Ammonium Compounds*
;
Bradycardia
;
Classification
;
Depression
;
Eating
;
Humans
;
Hypotension
;
Korea
;
Memory
;
Mortality
;
Seizures
;
Solvents
2.Median Raphe Cyst of the Penis.
Won hyoung KANG ; Seung Hun LEE ; Jin Soo KANG ; Sung Nack LEE
Korean Journal of Dermatology 1981;19(6):951-955
Median raphe cyst is not a cornmon disease and represents a defect in the embryologic development of male genitalia. It occurs most commonly near the glans penis, but may occur anywhere from the urethral meatus to the anus, and is lined by entodermal or ectodermal epithelium. Surgical excision is the treatment of choice. Recently we observed a 29-year-old male patient who had had a typical median raphe cyst since childhood on the ventral aspect of the glans penis. On histological examination, the cyst was lined by stratified columnar epithelium varied from four to eight cells in thickness.
Adult
;
Anal Canal
;
Ectoderm
;
Epithelium
;
Genitalia, Male
;
Humans
;
Male
;
Penis*
3.A Clinical Analysis of Acute Drug Intoxication in Emergency Department Setting.
Ji Hun KANG ; Hyun No LEE ; Young Ho JIN ; Jae Baek LEE
Journal of the Korean Society of Emergency Medicine 1999;10(3):431-440
BACKGROUND: Nowadays, acute drug intoxication is a important section of emergency medicine. The purpose of this study was to determine what is the best-way to manage acutely intoxicated patients with drug in emergency department setting. METHODS: Clinical assessment were made on 135 cases of drug intoxication visited to emergency center of Hospital during one year from June 1997 to May 1998. RESULTS: 1. The total number of cases of acute drug intoxication was 135 which is 0.5% of total patients presented to emergency center. 2. There was no sexual difference in incidence, but the highest incidence of age group was in 3rd decade(23.7%) and the next was 7th decade(20.0%). 3. High frequency of acute intoxication was observed in autumn. October had the largest portion in monthly distribution. The largest portion of presumed time of poisoning was noon - 4 p.m. and of the time on arrival to emergency center was 8 p.m. -midnight. 4. Suicidal attempt was the most common motive of intoxication (72.6%). 5. The most common drug of intoxication was insecticides (35.7%) and the others were centrally active agents, herbicides in orders. 6. Mental change was observed in 20.7% of patients and the abnormal vital signs were hypertension, tachycardia, and hypotension in order on arrival to emergency center. 7. Mean duration of treatment was 36.1 hours. Mortality rate of the cases was 7.4%. CONCLUSION: The mortality rate was high in patients who ingested relatively fatal drugs (i.e. herbicides, antimicrovials, insecticides), showed mental change on arrival or received mechanical ventilatory care(p<0.05).
Emergencies*
;
Emergency Medicine
;
Emergency Service, Hospital*
;
Herbicides
;
Humans
;
Hypertension
;
Hypotension
;
Incidence
;
Insecticides
;
Mortality
;
Poisoning
;
Tachycardia
;
Vital Signs
4.A Comparative study of the Implants used in the Management of Blowout Fracture.
Kwon JOO ; Sang Hun CHUNG ; Ki Taek HAN ; Ho KWON ; Jin Soo IM ; Yoon Jai KANG
Journal of the Korean Society of Plastic and Reconstructive Surgeons 1999;26(3):470-476
We developed an animal model to recreate the condition of an open fracture in communication with the maxillary sinus. We then studied wound healing of the sinus wall structures following fracture in the presence of autogenous bone and alloplastic implant. This model is designed to simulate the repair of an orbital floor fracture in humans. The New Zealand White rabbit was used as the animal model. Standardized 8mm defects were made bilaterally in the maxillary sinuses to include bone and mucosa in 36 rabbits. Two different implants and autogenous calvarial bone graft were placed in the soft-tissue pockets to obturate the defects, exposing one surface of the implant to the open sinus. Medpor porous polyethylene, silicone and calvarial bone implant were compared. Animals were killed at 1, 2 and 8 weeks after implantation. Gross examination of the specimens for the amount of mucosal closure and implant tissue fixation was performed. Histological sections were evaluated for bone and soft-tissue morphology juxtaposed to the implant. Complete closure of the mucosal defect was demonstrated with each type of implant. Medpor implants showed both vascular and soft-tissue ingrowth into pores by week 1. Bone ingrowth was seen by week 2. Closure of the Medpor obturated defects occurred more rapidly than in the silicone group. The Medpor implants and calvarial bone demonstrated bone and soft-tissue fixation, callus formation and maturation, while mature overlying mucosa was reconstituted over the defects. Silicone implants demonstrated a fibrous tissue reaction within 1 week of implantation and they never became fixed to bone or soft tissue. Maxillary sinus wall regeneration occurred in all defects. This study supports clinical observations of maxillary sinus wall regeneration in humans.
Animals
;
Bony Callus
;
Fractures, Open
;
Humans
;
Maxillary Sinus
;
Models, Animal
;
Mucous Membrane
;
New Zealand
;
Orbit
;
Polyethylene
;
Rabbits
;
Regeneration
;
Silicones
;
Tissue Fixation
;
Transplants
;
Wound Healing
5.Solitary Fibrofolliculoma: A case report.
Hun Kyung LEE ; Lee So MAENG ; Seok Jin KANG ; Soo Il CHUNG ; Sun Moo KIM
Korean Journal of Pathology 1996;30(5):460-462
The clinical and pathological features of solitary fibrofolliculoma are presented. Solitary fibrofolliculoma is very rarely encountered and to our knowledge, only 7 cases have been reported in the Western literature and no cases have been published in Korea. We experienced a case of solitary fibrofolliculoma occurring in a 56-year-old female, who had a 1.0 cm-sized and slowly growing nodule on her chin. A brief review of the literature, was made especially in relation to the pathological findings and histogenesis of solitary fibrofolliculoma.
Female
;
Humans
6.Comparative Measurement of Skin Surface Hydration Using a Hydrometer and Corneometer.
Seung Hun LEE ; Joon CHUNG ; Sung Ku AHN ; Jin Soo KANG ; Oh Kyu KWON
Korean Journal of Dermatology 1994;32(4):599-608
BACKGROUND: Hydration, the water content of the stratum corneum, is an important factor in both the appearance and the barrier function of the skin. Many non-invasive methods have been developed in order to assesa the hydration state of the skin and the effect of various moisturizers. The hydrometer and carneometer are commercially available instruments which are widely used in dermatologic research. OBJECTIVE: Our purpose was to compare the measuring usefulnes of both instruments on normal subjects with a wide range of hydration states of the hornylayer. METHODS: We measured the conductance with the hydrometer and the capacitance with the corneometer in various hydrating eonditions and compared both insruments. RESULTS: Conductance had a non linear correlation with capacita ice. Capacitance measured with the corneometer had a high sensitivity to moisture in a wide range of hydration levels. On the other hand, conductance guaged with the hydrometer showed a few sensitivity to moisture at a low level. When the hydretion level was measured after a moiturizer was added, 10 % urea cream showed a sharp increase by 256% in terms of conductanae, and H-base by 97.8%. Mineral oil decreased by 41.5% and petrolatum by 62% respectively. On the other hand, when measured in terms of capacitance under the same conditions as above, 38.9 increase in 10% urea cream, 19.3% increase in H-base, 20% decrease in mineral oil, and 43.5 % decrease in petrolatum were reported. Conductance showed a higher hygroscopicity and a lower water holding capacity than capacitance did. When the measurement of the moisture level iri virious parts of the human body is performed, the corneometer provided us with more stable alies than the hydrometer. While the hydrometer can not the available and appropriate under the condition of insulation, the corneometer can measure moisture levels even down at the depth of 250mm. When measured after the oily surface of the forehead was cleansed with soft tissue, conductance and capacitance revealed higher values of moisture levels than before the eleanin. However, there is no statistical significance in these values. CONCLUSION: The hydrometer is a more appropriate tool for the measurement of moisture at a high level, and the corneometer at a low moisture level. The hydrcmeter is a more sensitive method of measuring the increase and the decrease in the moisture level.
Forehead
;
Hand
;
Human Body
;
Ice
;
Lasers, Gas
;
Mineral Oil
;
Petrolatum
;
Skin*
;
Urea
;
Water
;
Wettability
7.Comparative Measurement of Skin Surface Hydration Using a Hydrometer and Corneometer.
Seung Hun LEE ; Joon CHUNG ; Sung Ku AHN ; Jin Soo KANG ; Oh Kyu KWON
Korean Journal of Dermatology 1994;32(4):599-608
BACKGROUND: Hydration, the water content of the stratum corneum, is an important factor in both the appearance and the barrier function of the skin. Many non-invasive methods have been developed in order to assesa the hydration state of the skin and the effect of various moisturizers. The hydrometer and carneometer are commercially available instruments which are widely used in dermatologic research. OBJECTIVE: Our purpose was to compare the measuring usefulnes of both instruments on normal subjects with a wide range of hydration states of the hornylayer. METHODS: We measured the conductance with the hydrometer and the capacitance with the corneometer in various hydrating eonditions and compared both insruments. RESULTS: Conductance had a non linear correlation with capacita ice. Capacitance measured with the corneometer had a high sensitivity to moisture in a wide range of hydration levels. On the other hand, conductance guaged with the hydrometer showed a few sensitivity to moisture at a low level. When the hydretion level was measured after a moiturizer was added, 10 % urea cream showed a sharp increase by 256% in terms of conductanae, and H-base by 97.8%. Mineral oil decreased by 41.5% and petrolatum by 62% respectively. On the other hand, when measured in terms of capacitance under the same conditions as above, 38.9 increase in 10% urea cream, 19.3% increase in H-base, 20% decrease in mineral oil, and 43.5 % decrease in petrolatum were reported. Conductance showed a higher hygroscopicity and a lower water holding capacity than capacitance did. When the measurement of the moisture level iri virious parts of the human body is performed, the corneometer provided us with more stable alies than the hydrometer. While the hydrometer can not the available and appropriate under the condition of insulation, the corneometer can measure moisture levels even down at the depth of 250mm. When measured after the oily surface of the forehead was cleansed with soft tissue, conductance and capacitance revealed higher values of moisture levels than before the eleanin. However, there is no statistical significance in these values. CONCLUSION: The hydrometer is a more appropriate tool for the measurement of moisture at a high level, and the corneometer at a low moisture level. The hydrcmeter is a more sensitive method of measuring the increase and the decrease in the moisture level.
Forehead
;
Hand
;
Human Body
;
Ice
;
Lasers, Gas
;
Mineral Oil
;
Petrolatum
;
Skin*
;
Urea
;
Water
;
Wettability
8.The Effects of Ventilation Rate and Characteristics of the Hand on Inspiratory Oxygen Concentration and Tidal Volume During Bag-Value Ventilation.
Young Ho JIN ; Tae Oh JEONG ; Ji Hun KANG ; Jae Baek LEE
Journal of the Korean Society of Emergency Medicine 1998;9(1):7-13
BACKGROUND: The self-inflating bag-valve resuscitator is an useful breathing support equipment in the cardiopulmonary resuscitation, the transportation of patients who required ventilation assist, or respiratory therapy. The inspiratory oxygen concentration (FiO2) or tidal volume (VT) delivered to the patient depends on various conditions during bag-valve ventilation. METHODS: During bag-valve ventilation without a reservoir at oxygen flow rates of 10 l/min, we evaluated fifty six volunteers to determine the FiO2 and VT at ventilatory frequencies of 10, 12 and 15 cycles per minute and to observe the effect of hand size and grasp power on FiO2 and VT in two-hand compression methods. RESULT: The FiO2 at frequency of 10 cycles/min were 50.1% and it was higher than other ventilatory frequencies. However, the VT was not statistically different among the changes of ventilatory frequency. In the change of VT according to characteristics of the hand, the operator's hand size exerted influence on VT(larger vs. smaller ; 942ml vs. 885ml, p<0.05), but the grasp power of the hand did not significantly affect. Separate analyses with size or grasp power of the hand failed to reveal significant differences of the FiO2. CONCLUSION: The results suggest that a slowing of ventilatory frequency within the allowable ranges for adequate gas exchange increase the FiO2 during bag-valve ventilation without reservoir, and that hand size may exert influence on the VT without FiO2 changes but grasp power may not be a contributing factor to the VT or FiO2 changes.
Cardiopulmonary Resuscitation
;
Hand Strength
;
Hand*
;
Humans
;
Oxygen*
;
Respiration
;
Respiratory Therapy
;
Tidal Volume*
;
Transportation of Patients
;
Ventilation*
;
Volunteers
9.Expression of Met Protein in Colorectal Carcinoma.
Kyung Un CHOI ; Jin Sook LEE ; Chang Hun LEE ; Mee Young SOL ; Kang Suk SUH
Korean Journal of Pathology 2000;34(7):501-508
Met protein is a transmembrane 190 kD heterodimer with tyrosine kinase activity, encoded by c-Met oncogene. It serves as a high affinity receptor for hepatocyte growth factor (HGF)/scatter factor (SF), a cytokine which stimulates cell proliferation, motility, and invasion. In this study, we immunohistochemically evaluated the expression of Met/hepatocyte growth factor receptor in colorectal cancers. Met protein was expressed in 31 of 72 patients (43.1%). The staining pattern was cytoplasmic in nature, present throughout the tumor, and showed variable intensity from case to case. The relationship between the expression rate and intensity, and age and sex of patients, tumor size (p=0.645), tumor site (p=0.902) and tumor differentiation (p=0.844) was not statistically significant. The expression rate and intensity were significantly correlated with lymphovascular invasion (p=0.001), lymph node metastasis (p=0.010), depth of invasion (0.019), and stage (p=0.023). Cytoplasmic accumulation of Met protein was not associated with enhanced PCNA index of tumor cells (p=0.052). These results suggest that Met protein may play an important role in the invasion and metastasis of colorectal cancer cells.
Cell Proliferation
;
Colorectal Neoplasms*
;
Cytoplasm
;
Hepatocyte Growth Factor
;
Humans
;
Lymph Nodes
;
Neoplasm Metastasis
;
Oncogenes
;
Proliferating Cell Nuclear Antigen
;
Protein-Tyrosine Kinases
10.Posttraumatic Aortic Regurgitation: Two Cases.
Bum Ju KIM ; Ji Hun KANG ; Youngho JIN ; Jae Baek LEE
Journal of the Korean Society of Emergency Medicine 2000;11(3):406-410
No abstract available.
Aortic Valve Insufficiency*