1.Secondary migration of a pre-existing central venous catheter due to a Swan-Ganz catheter insertion – A case report –
Joonho CHO ; Byung Hoon YOO ; Jihwan PARK ; Yun Hee LIM ; In-jung JUN ; Kye-min KIM
Anesthesia and Pain Medicine 2023;18(1):46-50
The entanglement of multiple central venous catheters is a rare and seriouscomplication. The Swan-Ganz catheter is a responsible for various cases.Case: A 66-year-old male patient was under general anesthesia for a coronary artery bypassgraft surgery. As he had a pre-existing Perm catheter in the right subclavian vein, a SwanGanz catheter was inserted into the left internal jugular vein. Chest radiograph after catheterplacement revealed that the Perm catheter had migrated to the left brachiocephalic vein.The surgeon attempted to reposition it manually, but postoperative radiograph showed thatit had rolled into a loop. On postoperative day 1, radiological intervention was performed tountangle the loop, which was successful.Conclusions: After placing a Swan-Ganz catheter in patients with a pre-existing central venous catheter, the presence of entanglement should be assessed. In such cases, radiology-guided correction is recommended, as a blind attempt to disentangle can aggravate thecondition.
2.Management of a Remnant Electrode in a Patient With Cardioverter-Defibrillator Infection After Refusal of Intravascular Electrode Removal.
Sunghwahn HAHN ; Jihwan KIM ; Jung Hyun CHOI ; Seong Hoon LIM ; Tae Soo KANG ; Byoung Eun PARK ; Myung Yong LEE
Korean Circulation Journal 2011;41(1):46-50
Treatments of choice for cardiac implantable electronic device (CIED) infections are the removal of the entire CIED system, control of infection, and new device implantation. Occasionally, a complete CIED removal can not be performed for several reasons, such as very old age, severe comobidity, limited life expectancy, or refusal by a patient. We encountered a male patient who developed traumatic CIED infection five years after cardioverter-defibrillator implantation. An intravenous electrode could not be removed by a simple transvenous extraction procedure, and he refused surgical removal of the remnant electrode. After control of local infection, the tips of the electrode were separated and buried between muscles, and the wound was closed with a local flap. CIED infection did not recur for 12 months even without relying on long-term antimicrobial treatment.
Defibrillators, Implantable
;
Disulfiram
;
Electrodes
;
Electrodes, Implanted
;
Electronics
;
Electrons
;
Humans
;
Life Expectancy
;
Male
;
Muscles
3.Age, Sex, and Body Mass Index Should Be Considered When Assessing Spleen Length in Patients with Compensated Advanced Chronic Liver Disease
Han Ah LEE ; Seung Up KIM ; Jihwan LIM ; Moon Young KIM ; Sang Gyune KIM ; Ki Tae SUK ; Jae Young JANG ; Hyonggin AN ; Hyung Joon YIM ; Yeon Seok SEO
Gut and Liver 2023;17(2):299-307
Background/Aims:
We investigated the factors related to spleen length and the diagnostic accuracy of a model using spleen length corrected by related factors, for the prediction of varices needing treatment (VNT).
Methods:
Various prediction models for VNT including spleen length were analyzed in the cohort of compensated advanced chronic liver disease (cACLD), defined as liver stiffness (LS) ≥10 kPa in a recent study. The associated factors for spleen length were identified in healthy subjects to improve the prediction of VNT.
Results:
Among 1,218 cACLD patients, VNT was noted in 249 patients (20.4%). On multivariate analysis, longer spleen length, lower platelet count, and higher LS value were independent predictors for VNT (all p<0.001). In multivariate analysis of 1,041 healthy subjects, age (β=–0.027), sex (β=0.762), and body mass index (β=0.097) were found to be significant factors for spleen length (all p<0.001). Using the β values, the estimated spleen length was calculated. To improve the prediction of VNT, the ratio of measured and estimated spleen length was calculated. Based on binary regression analysis results, the LS value-spleen ratio to platelet score (LSRPS) was calcu-lated as follows: 0.027×LS value (kPa)+2.690×measured/estimated spleen ratio–0.011×platelet count (cells×10 9 /L)–4.215. The area under the receiver operating characteristic of the LSRPS for VNT was 0.820, which was significantly higher than 0.797 of LS value-spleen diameter to plateletratio score (LSPS) (p=0.006).
Conclusions
Spleen length is influenced by age, sex, and body mass index in the Asian population. The LSRPS using the measured/estimated spleen ratio had higher diagnostic accuracy than LSPS in predicting VNT in patients with cACLD.
4.Serum milk fat globule-EGF factor 8 protein as a potential biomarker for metabolic syndrome
Han Ah LEE ; Jihwan LIM ; Hyung Joon JOO ; Young-Sun LEE ; Young Kul JUNG ; Ji Hoon KIM ; Hyunggin AN ; Hyung Joon YIM ; Yoon Tae JEEN ; Jong Eun YEON ; Do-Sun LIM ; Kwan Soo BYUN ; Yeon Seok SEO
Clinical and Molecular Hepatology 2021;27(3):463-473
Background/Aims:
Useful biomarkers for metabolic syndrome have been insufficient. We investigated the performance of serum milk fat globule-EGF factor-8 (MFG-E8), the key mediator of inflammatory pathway, in diagnosis of metabolic syndrome.
Methods:
Subjects aged between 30 and 64 years were prospectively enrolled in the Seoul Metabolic Syndrome cohort. Serum MFG-E8 levels were measured at baseline.
Results:
A total of 556 subjects were included, comprising 279 women (50.2%) and 277 men (49.8%). Metabolic syndrome was diagnosed in 236 subjects (42.4%), and the mean MFG-E8 level of subjects with metabolic syndrome was significantly higher than that of subjects without metabolic syndrome (P<0.001). MFG-E8 level was significantly correlated with all metabolic syndrome components and pulse wave velocity (all P<0.05). Subjects were categorized into two groups according to the best MFG-E8 cut-off value as follows: group 1, MFG-E8 level <4,745.1 pg/mL (n=401, 72.1%); and group 2, MFG-E8 level ≥4,745.1 (n=155, 27.9%). At baseline, metabolic syndrome in group 2 was significantly more prevalent than in group 1 (63.9% vs. 34.2%, P<0.001). During median follow-up of 17 months, metabolic syndrome developed in 122 (38.1%) subjects among 320 subjects without it at baseline. The incidence of metabolic syndrome in group 2 was significantly higher than that in group 1 (55.4% vs. 34.5%, P=0.003). On multivariate analysis, MFG-E8 level ≥4,745.1 pg/mL was an independent predictor for diagnosis and development of metabolic syndrome after adjusting other factors (all P<0.05).
Conclusions
Serum MFG-E8 level is a potent biomarker for the screening and prediction of metabolic syndrome.
5.Serum milk fat globule-EGF factor 8 protein as a potential biomarker for metabolic syndrome
Han Ah LEE ; Jihwan LIM ; Hyung Joon JOO ; Young-Sun LEE ; Young Kul JUNG ; Ji Hoon KIM ; Hyunggin AN ; Hyung Joon YIM ; Yoon Tae JEEN ; Jong Eun YEON ; Do-Sun LIM ; Kwan Soo BYUN ; Yeon Seok SEO
Clinical and Molecular Hepatology 2021;27(3):463-473
Background/Aims:
Useful biomarkers for metabolic syndrome have been insufficient. We investigated the performance of serum milk fat globule-EGF factor-8 (MFG-E8), the key mediator of inflammatory pathway, in diagnosis of metabolic syndrome.
Methods:
Subjects aged between 30 and 64 years were prospectively enrolled in the Seoul Metabolic Syndrome cohort. Serum MFG-E8 levels were measured at baseline.
Results:
A total of 556 subjects were included, comprising 279 women (50.2%) and 277 men (49.8%). Metabolic syndrome was diagnosed in 236 subjects (42.4%), and the mean MFG-E8 level of subjects with metabolic syndrome was significantly higher than that of subjects without metabolic syndrome (P<0.001). MFG-E8 level was significantly correlated with all metabolic syndrome components and pulse wave velocity (all P<0.05). Subjects were categorized into two groups according to the best MFG-E8 cut-off value as follows: group 1, MFG-E8 level <4,745.1 pg/mL (n=401, 72.1%); and group 2, MFG-E8 level ≥4,745.1 (n=155, 27.9%). At baseline, metabolic syndrome in group 2 was significantly more prevalent than in group 1 (63.9% vs. 34.2%, P<0.001). During median follow-up of 17 months, metabolic syndrome developed in 122 (38.1%) subjects among 320 subjects without it at baseline. The incidence of metabolic syndrome in group 2 was significantly higher than that in group 1 (55.4% vs. 34.5%, P=0.003). On multivariate analysis, MFG-E8 level ≥4,745.1 pg/mL was an independent predictor for diagnosis and development of metabolic syndrome after adjusting other factors (all P<0.05).
Conclusions
Serum MFG-E8 level is a potent biomarker for the screening and prediction of metabolic syndrome.