1.Simulating the Effect of Junction Setup Error in Dual-Isocentric Volumetric Modulated Arc Therapy for Pelvic Radiotherapy with a Large Target
Hojeong LEE ; Dong Woon KIM ; Ji Hyeon JOO ; Yongkan KI ; Wontaek KIM ; Dahl PARK ; Jiho NAM ; Dong Hyeon KIM ; Hosang JEON
Progress in Medical Physics 2024;35(2):52-57
Purpose:
The use of two adjacent radiation beams to treat a lesion that is larger than the maximum field of a machine may lead to higher or lower dose distribution at the junction than expected. Therefore, evaluation of the junction dose is crucial for radiotherapy. Volumetric modulated arc therapy (VMAT) can effectively protect surrounding normal tissues by implementing a complex dose distribution; therefore, two adjacent VMAT fields can effectively treat large lesions. However, VMAT can lead to significant errors in the junction dose between fields if setup errors occur due to its highly complex dose distributions.
Methods:
In this study, setup errors of ±1, ±3, and ±5 mm were assumed during radiotherapy for treating large lesions in the lower abdomen, and their effects on the treatment dose distribution and target coverage were analyzed using gamma pass rate (GP) and homogeneity index (HI). All studies were performed using a computational simulation method based on our radiation treatment planning software.
Results:
Consequently, when the setup error was more than ±3 mm, most GP values using a 3%/3-mm criterion decreased by <90%. GP was independent of the direction of the field gap (FG), whereas HI values were relatively more affected by negative values for FG.
Conclusions
Therefore, the size and direction of setup errors should be carefully managed when performing dual-isocentric VMATs for large targets.
2.Simulating the Effect of Junction Setup Error in Dual-Isocentric Volumetric Modulated Arc Therapy for Pelvic Radiotherapy with a Large Target
Hojeong LEE ; Dong Woon KIM ; Ji Hyeon JOO ; Yongkan KI ; Wontaek KIM ; Dahl PARK ; Jiho NAM ; Dong Hyeon KIM ; Hosang JEON
Progress in Medical Physics 2024;35(2):52-57
Purpose:
The use of two adjacent radiation beams to treat a lesion that is larger than the maximum field of a machine may lead to higher or lower dose distribution at the junction than expected. Therefore, evaluation of the junction dose is crucial for radiotherapy. Volumetric modulated arc therapy (VMAT) can effectively protect surrounding normal tissues by implementing a complex dose distribution; therefore, two adjacent VMAT fields can effectively treat large lesions. However, VMAT can lead to significant errors in the junction dose between fields if setup errors occur due to its highly complex dose distributions.
Methods:
In this study, setup errors of ±1, ±3, and ±5 mm were assumed during radiotherapy for treating large lesions in the lower abdomen, and their effects on the treatment dose distribution and target coverage were analyzed using gamma pass rate (GP) and homogeneity index (HI). All studies were performed using a computational simulation method based on our radiation treatment planning software.
Results:
Consequently, when the setup error was more than ±3 mm, most GP values using a 3%/3-mm criterion decreased by <90%. GP was independent of the direction of the field gap (FG), whereas HI values were relatively more affected by negative values for FG.
Conclusions
Therefore, the size and direction of setup errors should be carefully managed when performing dual-isocentric VMATs for large targets.
3.Simulating the Effect of Junction Setup Error in Dual-Isocentric Volumetric Modulated Arc Therapy for Pelvic Radiotherapy with a Large Target
Hojeong LEE ; Dong Woon KIM ; Ji Hyeon JOO ; Yongkan KI ; Wontaek KIM ; Dahl PARK ; Jiho NAM ; Dong Hyeon KIM ; Hosang JEON
Progress in Medical Physics 2024;35(2):52-57
Purpose:
The use of two adjacent radiation beams to treat a lesion that is larger than the maximum field of a machine may lead to higher or lower dose distribution at the junction than expected. Therefore, evaluation of the junction dose is crucial for radiotherapy. Volumetric modulated arc therapy (VMAT) can effectively protect surrounding normal tissues by implementing a complex dose distribution; therefore, two adjacent VMAT fields can effectively treat large lesions. However, VMAT can lead to significant errors in the junction dose between fields if setup errors occur due to its highly complex dose distributions.
Methods:
In this study, setup errors of ±1, ±3, and ±5 mm were assumed during radiotherapy for treating large lesions in the lower abdomen, and their effects on the treatment dose distribution and target coverage were analyzed using gamma pass rate (GP) and homogeneity index (HI). All studies were performed using a computational simulation method based on our radiation treatment planning software.
Results:
Consequently, when the setup error was more than ±3 mm, most GP values using a 3%/3-mm criterion decreased by <90%. GP was independent of the direction of the field gap (FG), whereas HI values were relatively more affected by negative values for FG.
Conclusions
Therefore, the size and direction of setup errors should be carefully managed when performing dual-isocentric VMATs for large targets.
4.Simulating the Effect of Junction Setup Error in Dual-Isocentric Volumetric Modulated Arc Therapy for Pelvic Radiotherapy with a Large Target
Hojeong LEE ; Dong Woon KIM ; Ji Hyeon JOO ; Yongkan KI ; Wontaek KIM ; Dahl PARK ; Jiho NAM ; Dong Hyeon KIM ; Hosang JEON
Progress in Medical Physics 2024;35(2):52-57
Purpose:
The use of two adjacent radiation beams to treat a lesion that is larger than the maximum field of a machine may lead to higher or lower dose distribution at the junction than expected. Therefore, evaluation of the junction dose is crucial for radiotherapy. Volumetric modulated arc therapy (VMAT) can effectively protect surrounding normal tissues by implementing a complex dose distribution; therefore, two adjacent VMAT fields can effectively treat large lesions. However, VMAT can lead to significant errors in the junction dose between fields if setup errors occur due to its highly complex dose distributions.
Methods:
In this study, setup errors of ±1, ±3, and ±5 mm were assumed during radiotherapy for treating large lesions in the lower abdomen, and their effects on the treatment dose distribution and target coverage were analyzed using gamma pass rate (GP) and homogeneity index (HI). All studies were performed using a computational simulation method based on our radiation treatment planning software.
Results:
Consequently, when the setup error was more than ±3 mm, most GP values using a 3%/3-mm criterion decreased by <90%. GP was independent of the direction of the field gap (FG), whereas HI values were relatively more affected by negative values for FG.
Conclusions
Therefore, the size and direction of setup errors should be carefully managed when performing dual-isocentric VMATs for large targets.
5.Simulating the Effect of Junction Setup Error in Dual-Isocentric Volumetric Modulated Arc Therapy for Pelvic Radiotherapy with a Large Target
Hojeong LEE ; Dong Woon KIM ; Ji Hyeon JOO ; Yongkan KI ; Wontaek KIM ; Dahl PARK ; Jiho NAM ; Dong Hyeon KIM ; Hosang JEON
Progress in Medical Physics 2024;35(2):52-57
Purpose:
The use of two adjacent radiation beams to treat a lesion that is larger than the maximum field of a machine may lead to higher or lower dose distribution at the junction than expected. Therefore, evaluation of the junction dose is crucial for radiotherapy. Volumetric modulated arc therapy (VMAT) can effectively protect surrounding normal tissues by implementing a complex dose distribution; therefore, two adjacent VMAT fields can effectively treat large lesions. However, VMAT can lead to significant errors in the junction dose between fields if setup errors occur due to its highly complex dose distributions.
Methods:
In this study, setup errors of ±1, ±3, and ±5 mm were assumed during radiotherapy for treating large lesions in the lower abdomen, and their effects on the treatment dose distribution and target coverage were analyzed using gamma pass rate (GP) and homogeneity index (HI). All studies were performed using a computational simulation method based on our radiation treatment planning software.
Results:
Consequently, when the setup error was more than ±3 mm, most GP values using a 3%/3-mm criterion decreased by <90%. GP was independent of the direction of the field gap (FG), whereas HI values were relatively more affected by negative values for FG.
Conclusions
Therefore, the size and direction of setup errors should be carefully managed when performing dual-isocentric VMATs for large targets.
6.Prevalence and Associated Factors of Depression and Anxiety Among Healthcare Workers During the Coronavirus Disease 2019 Pandemic:A Nationwide Study in Korea
Shinwon LEE ; Soyoon HWANG ; Ki Tae KWON ; EunKyung NAM ; Un Sun CHUNG ; Shin-Woo KIM ; Hyun-Ha CHANG ; Yoonjung KIM ; Sohyun BAE ; Ji-Yeon SHIN ; Sang-geun BAE ; Hyun Wook RYOO ; Juhwan JEONG ; NamHee OH ; So Hee LEE ; Yeonjae KIM ; Chang Kyung KANG ; Hye Yoon PARK ; Jiho PARK ; Se Yoon PARK ; Bongyoung KIM ; Hae Suk CHEONG ; Ji Woong SON ; Su Jin LIM ; Seongcheol YUN ; Won Sup OH ; Kyung-Hwa PARK ; Ju-Yeon LEE ; Sang Taek HEO ; Ji-yeon LEE
Journal of Korean Medical Science 2024;39(13):e120-
Background:
A healthcare system’s collapse due to a pandemic, such as the coronavirus disease 2019 (COVID-19), can expose healthcare workers (HCWs) to various mental health problems. This study aimed to investigate the impact of the COVID-19 pandemic on the depression and anxiety of HCWs.
Methods:
A nationwide questionnaire-based survey was conducted on HCWs who worked in healthcare facilities and public health centers in Korea in December 2020. Patient Health Questionnaire-9 (PHQ-9) and Generalized Anxiety Disorder-7 (GAD-7) were used to measure depression and anxiety. To investigate factors associated with depression and anxiety, stepwise multiple logistic regression analysis was performed.
Results:
A total of 1,425 participating HCWs were included. The mean depression score (PHQ-9) of HCWs before and after COVID-19 increased from 2.37 to 5.39, and the mean anxiety score (GAD-7) increased from 1.41 to 3.41. The proportion of HCWs with moderate to severe depression (PHQ-9 ≥ 10) increased from 3.8% before COVID-19 to 19.5% after COVID-19, whereas that of HCWs with moderate to severe anxiety (GAD-7 ≥ 10) increased from 2.0% to 10.1%. In our study, insomnia, chronic fatigue symptoms and physical symptoms after COVID-19, anxiety score (GAD-7) after COVID-19, living alone, and exhaustion were positively correlated with depression. Furthermore, post-traumatic stress symptoms, stress score (Global Assessment of Recent Stress), depression score (PHQ-9) after COVID-19, and exhaustion were positively correlated with anxiety.
Conclusion
In Korea, during the COVID-19 pandemic, HCWs commonly suffered from mental health problems, including depression and anxiety. Regularly checking the physical and mental health problems of HCWs during the COVID-19 pandemic is crucial, and social support and strategy are needed to reduce the heavy workload and psychological distress of HCWs.
7.Analysis of risk factors for disease progression after salvage radiation therapy with androgen deprivation therapy in prostate cancer patients who have prostate-specific antigen persistence after radical prostatectomy
Kyeonghyo LEE ; Dongchan KIM ; Jiho NAM ; Dahl PARK ; Wontaek KIM ; Jihyeon JOO ; Hosang JEON ; Yongkan KI ; Donghyun KIM
Radiation Oncology Journal 2024;42(2):124-129
Purpose:
To assess risk factors of disease progression after salvage radiation therapy (SRT) with androgen deprivation therapy (ADT) in case of prostate-specific antigen (PSA) persistence after radical prostatectomy (RP).
Materials and Methods:
We analyzed 57 patients who received SRT with ADT between 2013 and 2019 due to PSA persistence after RP. The endpoint was disease progression defined by biochemical recurrence or clinical recurrence. Age, Pre-RP PSA level, Gleason score, pathologic stage, presence of pelvic lymph node dissection, surgical margins, and PSA at 6-8 weeks after RP were analyzed as predictive factors for disease progression. Kaplan-Meier method and Cox regression models were used for data analysis.
Results:
At a median follow-up of 38 months (interquartile range, 26–61), 17 patients had disease progression. Pathologic T stage (pT3b vs. pT3a or lower; hazard ratio [HR] = 9.20; p = 0.035) and PSA level at 6-8 weeks after RP (≥2.04 vs. <2.04 ng/mL; HR = 5.85; p = 0.002) were predictors of disease progression. The 5-year disease progression-free survival rate was 46.7% in pT3b group as compared to 92.9 % in pT3a or lower group, and 18.4% for PSA ≥2.04 ng/mL after RP as compared to 79.2% for PSA <2.04 ng/mL.
Conclusion
Pathological T stage (pT3b) and post RP PSA ≥2.04 ng/mL are independent risk factors of disease progression after SRT with ADT in patients with PSA persistence after RP.
8.Modified Charlson comorbidity index as a survival prediction tool for older patients after liver transplantation
Jiho CHOI ; Eun-Woo CHOI ; YoungRok CHOI ; Su young HONG ; Sanggyun SUH ; Kwangpyo HONG ; Eui Soo HAN ; Jeong-moo LEE ; Suk Kyun HONG ; Nam-Joon YI ; Kwang-Woong LEE ; Kyung-Suk SUH
Annals of Surgical Treatment and Research 2023;104(6):358-363
Purpose:
An increasing number of older patients now undergo liver transplantation (LT). Although the overall outcomes in older patients are not different from those of younger patients, there is no tool to predict LT prognosis in older patients.We hypothesized that a modified Charlson comorbidity index (mCCI) and 5-factor modified frailty index (mFI-5) can predict outcomes in older patients after LT.
Methods:
This retrospective study included 155 patients (aged >65 years) who underwent LT at Seoul National University Hospital. The recipients were subcategorized into 2 groups based on the mCCI score and mFI-5: the low (0–1) and high (2–5) mCCI groups, and low (≤0.4) and high (>0.4) mFI-5 groups. The independent effect of each variable on post-LT survival was determined using the mCCI subgroup, age at transplantation, sex, Child-Turcotte-Pugh score, model for end-stage liver disease (MELD) score, and mFI-5 subgroup.
Results:
The high-mCCI group (41 patients) showed significantly lower 1- and 3-month and 1-, 3-, and 5-year survival than the low-mCCI group. Using the Cox regression model, the mCCI, sex, and MELD score remained significant. The mFI-5 was not a significant factor to predict patients’ survival.
Conclusion
The mCCI and MELD scores could be used to predict post-LT survival in older patients.
9.Prognostic value of the maximum standardized uptake value for the locoregional control in early glottic cancer
Donghyun KIM ; Yongkan KI ; Jihyeon JOO ; Hosang JEON ; Dahl PARK ; Jiho NAM ; Wontaek KIM
Radiation Oncology Journal 2021;39(4):297-303
Purpose:
To evaluate the prognostic value of the pretreatment maximum standardized uptake value (SUVmax) for locoregional control (LRC) of early glottic cancer treated with primary radiotherapy.
Materials and Methods:
We retrospectively reviewed the medical records of 101 patients with T1-T2N0 glottic cancer treated with helical tomotherapy between 2013 and 2016. The clinical T-stages were T1 in 87 (86.1%) and T2 in 14 (13.9%) patients. The median total dose was 63 Gy (63–67.5 Gy) in 2.25 Gy per fraction. The survival outcomes were plotted using Kaplan-Meier curves. Receiver operating characteristic curves were used to assess the optimal SUVmax cut-off value for predicting locoregional recurrence.
Results:
The median follow-up period was 58 months (range, 11 to 90 months). The 5-year overall survival (OS) and locoregional recurrence-free survival rates were 96.8% and 85.4%, respectively. The median pretreatment SUVmax of the primary tumor for all 101 patients was 2.3 (range, 1.1 to 9.1). The best cut-off value for SUVmax for predicting LRC was 3.3, with a sensitivity of 78.6% and specificity of 73.6%. Univariate analysis showed that T-stage, overall treatment time (≥43 days), and high SUVmax (≥3.3) were significant predictors of LRC. Multivariate analysis showed that LRC was independently affected by a high SUVmax (≥3.3) (hazard ratio = 5.505, p = 0.020).
Conclusion
High pretreatment SUVmax (≥3.3) is a negative prognostic factor for LRC in early glottic cancer patients treated with primary radiotherapy.
10.Adaptive Image Rescaling for Weakly Contrast-Enhanced Lesions in Dedicated Breast CT:A Phantom Study
Bitbyeol KIM ; Ho Kyung KIM ; Jinsung KIM ; Yongkan KI ; Ji Hyeon JOO ; Hosang JEON ; Dahl PARK ; Wontaek KIM ; Jiho NAM ; Dong Hyeon KIM
Journal of the Korean Radiological Society 2021;82(6):1477-1492
Purpose:
Dedicated breast CT is an emerging volumetric X-ray imaging modality for diagnosis that does not require any painful breast compression. To improve the detection rate of weakly enhanced lesions, an adaptive image rescaling (AIR) technique was proposed.
Materials and Methods:
Two disks containing five identical holes and five holes of different diameters were scanned using 60/100 kVp to obtain single-energy CT (SECT), dual-energy CT (DECT), and AIR images. A piece of pork was also scanned as a subclinical trial. The image quality was evaluated using image contrast and contrast-to-noise ratio (CNR). The difference of imaging performances was confirmed using student’s t test.
Results:
Total mean image contrast of AIR (0.70) reached 74.5% of that of DECT (0.94) and was higher than that of SECT (0.22) by 318.2%. Total mean CNR of AIR (5.08) was 35.5% of that of SECT (14.30) and was higher than that of DECT (2.28) by 222.8%. A similar trend was observed in the subclinical study.
Conclusion
The results demonstrated superior image contrast of AIR over SECT, and its higher overall image quality compared to DECT with half the exposure. Therefore, AIR seems to have the potential to improve the detectability of lesions with dedicated breast CT.

Result Analysis
Print
Save
E-mail