1.Value of CTA in assessing the relationship between the fat volume around coronary artery plaques and the abnormal coronary artery hemodynamics
Haolei LIU ; Jieli KOU ; Chao LIU ; Lizhou YANG ; Deqiang CHEN
China Medical Equipment 2024;21(9):42-46
Objective:To explore the value of coronary computed tomography angiography(CCTA)in assessing the relationship between the fat volume around coronary plaque and the abnormal coronary hemodynamics.Methods:A total of 218 hospitalized patients admitted to Cangzhou People's Hospital from June 2022 to September 2023 were selected.In these patients,108 patients without coronary heart disease(CHD)were included in the control group,and 110 CHD patients were included in the observation group.All patients underwent CCTA examination to compare the CT imaging values(FFRCT)of the fat volume around heart and blood flow reserve fraction between the two groups.Receiver operating characteristic(ROC)curve was performed to analyze the efficacy of the fat volume around heart and FFRCT values in predicting coronary artery plaques.Additionally,Pearson's method was used to analyze the correlation between fat volume around heart and FFRCT.Results:The fat volume around heart in the observation group was(168.70±38.16)cm3,which was significantly higher than(98.75±21.19)cm3 in the control group,and the FFRCT value(0.78±0.11)of the observation group was lower than(0.89±0.10)in the control group,with statistically significant differences(t=16.688,8.041,P<0.05),respectively.In the observation group,89 patients occurred plaque,and 21 patients did not occur plaque.In the observation group,the fat volume around heart in patients with plaques was(176.63±34.15)cm3,which was significantly higher than(133.52±36.85)cm3 in patients without plaques,and the FFRCT value in patients with plaques was(0.76±0.10),which was significantly lower than(0.85±0.11)in patients without plaques,with statistically significant differences(t=4.945,3.815,P<0.05),respectively.According to Pearson's analysis,there was a negative correlation between the fat volume around heart and FFRCT value.According to Spearman's analysis,with or without plaques appeared positive correlation with the fat volume around heart in CHD patients,and they appeared negative correlation with FFRct value.According to ROC curve analysis,the area under curve(AUC)values of fat volume around heart,FFRCT,and the combination of them were respectively 0.777,0.726 and 0.930 in predicting the plaques of CHD patients.Conclusion:Hemodynamics and fat volume around heart that is measured by CCTA can predict coronary plaque,and there is a certain of relationship between coronary hemodynamics and the fat volume around coronary artery plaques,which appears negative correlation.
2.Clinical value of serum miR-106b-5p and miR-760 combined with low-dose spiral CT in the diagnosis of early lung cancer
Na LIU ; Jieli KOU ; Feng YANG ; Taotao LIU ; Danping LI ; Junrui HAN ; Lizhou YANG
Journal of International Oncology 2024;51(6):321-325
Objective:To investigate the levels of microRNA (miR) -106b-5p and miR-760 in the serum of early lung cancer patients, and the clinical value of the combination of them and low-dose spiral CT in the diagnosis of early lung cancer.Methods:Ninety early lung cancer patients (lung cancer group) who underwent treatment in Cangzhou People's Hospital of Hebei Province from January 2022 to March 2023 were collected as research subjects, meantime, 90 patients with benign pulmonary lesions (benign pulmonary nodules) diagnosed by pathology were selected as the control group. The levels of miR-106b-5p and miR-760 in the serum of two groups were compared, the results of low-dose spiral CT examination were analyzed; receiver operating characteristic curve was drawn to determine the optimal cut-off values of serum miR-106b-5p and miR-760; four grid table method was applied to analyze the diagnostic efficacy of serum miR-106b-5p, miR-760 combined with low-dose spiral CT for early lung cancer.Results:The level of miR-106b-5p in lung cancer group was higher than that in control group (1.39±0.31 vs. 1.04±0.30), serum miR-760 level was lower than that in control group (0.75±0.24 vs. 1.02±0.26), with statistically significant differences ( t=7.70, P<0.001; t=7.24, P<0.001). The area under curve (AUC) of miR-106b-5p, miR-760 and low-dose spiral CT in the diagnosis of early lung cancer was 0.83, 0.81 and 0.82, the accuracy was 76.67%, 77.22% and 81.67%, the sensitivity was 84.44%, 81.11% and 76.67%, and the specificity was 68.89%, 73.33% and 86.67%, respectively. The AUC, accuracy, sensitivity, and specificity of serum miR-106b-5p, miR-760 combined with low-dose spiral CT in diagnosing early lung cancer were 0.96, 90.00%, 94.44%, and 85.56%, respectively. The accuracy of the three combined diagnosis was higher than that of individual diagnosis of miR-106b-5p, miR-760 and low-dose spiral CT ( χ2=11.52, P=0.001; χ2=10.72, P=0.001; χ2=5.14, P=0.023), the sensitivity of the three combined diagnosis was higher than that of individual diagnosis of miR-106b-5p, miR-760 and low-dose spiral CT ( χ2=4.77, P=0.029; χ2=7.46, P=0.006; χ2=11.51, P=0.001), the specificity of the three combined diagnosis was higher than that of individual diagnosis of miR-106b-5p, miR-760 ( χ2=7.11, P=0.008; χ2=4.12, P=0.042) . Conclusion:The serum level of miR-106b-5p is significantly increased in early lung cancer patients, while the serum level of miR-760 is significantly reduced. The combination of miR-106b-5p, miR-760 and low-dose spiral CT has high diagnostic value for early lung cancer.