1.Design of method comparison study and bias estimation for albumin assays
Jian GUO ; Jiehong XIE ; Haijian ZHAO
Chinese Journal of Laboratory Medicine 2000;0(06):-
Objective It describes procedures for designing an analyzing a method comparison experiment for serum albumin(ALB) assay and determining the relative bias between two methods using split patient samples.Method According to the procedure described by the NCCL approved guideline: method comparison and bias estimation using patient samples; 40 patient samples were analyzed in 5 operating days, analyze each patient sample in duplicate using both BCG and BCP method. The duplicates were assessed for each method within the same run. The coefficient of correlation was calculated as well as the bia between the methods.Results In the patient′s serum sample, the bias between BCG and BCP methods were 1.8% at 50g/L or 5.5% at 40 g/L or 11.6% at 30 g/L for albumin. In the commercial quality control serum products, the bias between the two methods varied up to 36%.Conclusion In determination of the patient′s ALB, the bias between BCG and BCP goes up when the concentration of ALB is decreased. But the bias between the two methods varies up to 36% when the quality control serum is determined.
2.External quality assessment for the quantitative detection of HCV RNA in China
Kuo ZHANG ; Lunan WANG ; Rui ZHANG ; Jiehong XIE ; Jinming LI
Chinese Journal of Laboratory Medicine 2010;33(10):977-981
Objective Anti-RNase virus-like particles containing HCV RNA 5'-UTR were used as positive samples in national external quality assessment ( EQA ) to evaluate the competency of clinical Laboratories for the quantification of HCV RNA and analyze the possible problems of domestic kits. Methods The quality control samples with target values in EQA panels were distributed nationally twice by National Center of Clinical Laboratory (NCCL) to participating laboratories for the quantification of HCV RNA in 2008 and 2009. Each panel consisted of 5 samples. All participants were required to carry out the detection and to return results in expected time. Positive samples were virus-like particles which had been calibrated against the WHO HCV International Standard (NIBSC96/798)and the results of positive samples from participants should be in the range of target value of logarithm ± 0. 5. The 2nd panel in 2008 contained the common HCV genotypes and the 2nd panel in 2009 contained serial diluted samples of genotype 1b. The results of positive samples detected with 3 different lots reagent (21001,21078 and 21097) from the 2nd EQA in 2009 were statistically analyzed using the analysis of variance, then Dunnett'S T3 and Tamhane'S T2 were used if heterogeneity of variance was found. Results There was 390 participating laboratories in 2008 and 428/426 in 2009. The percentages of laboratories within the range of target value of logarithm ± 0. 5 for varied genotypes were different. The percentages of laboratories for 1b were more than 91%, for 2a were 93.7% and 74. 2% ,for6 were 83.3% and 80. 3%. The CVfor the low-level sample was higher than that for the high-level sample in the same year. The numbers of laboratories reporting false-negative samples in 2008and the 2nd in 2009 were 5, 1 and 10 respectively. Statistical differences were found among the results of four quality control serum samples using 3 different reagents( F = 288.23, 324. 79, 291.98 and 261.16,P <0. 01 ). Conclusion The competency for detecting low concentration samples and samples with genotype 2a or 6 needs to be improved.
3.External quality assessment of autoantibodies detection in clinical laboratories during 2006-2011 in China
Rui ZHANG ; Kuo ZHANG ; Lunan WANG ; Jiehong XIE ; Jinming LI
Chinese Journal of Laboratory Medicine 2012;35(3):271-276
ObjectiveTo evaluate the performance of antinuclear antibody (ANA) detection in clinical laboratories.Methods There were 2 external quality assessments (EQA) scheme for nuclear antibody detection.The panel consisting of 5 samples was distributed.Each participant laborotory of the EQA program was required to report the ANA qualitative results,patterns,titers and anti-double strain DNA (dsDNA) antibody,anti-extractable nuclear antigen(ENA) antibody,the percent agreements of which were calculated respectively.ResultsThe number of laboratories performing ANA test with IIF increased from 77.6% ( 149/192 )in 2006 to 82.2% (342/416) in 2011,while the number of laboratories performing ANA test with ELISA was in the range of 14.5% ( 53/365 ) and 16.0% ( 52/326 ).The positive percent agreements of IIF was over 98%.The positive percent agreement of ELISA were all over 90%.IIF showed more satisfying positive percent agreements than ELISA every year.Over 90% of the laboratories reported correct results for samples with granular ANA pattern except 0613 and 0624.Over 95% of the laboratories reported correct results for samples with homogeneous ANA pattern.Two samples with centromere pattern were correctly detected by 88.5% ( 161/182 ),79.0% ( 147/186 ) of the laboratories in 2007,while the sample with centromere pattern was correctly detected by 98.4% (299/304), which indicated an improvement in the detection of centromere pattern.In ANA positive results,the lowest percentage of the laboratories reporting the median result was 36% (94/261),while the highest percentage was only 85.5%(224/262).The satisfied results of anti-ENA antibody were over 90%.And those of anti-dsDNA antibody was over 85%.ConclusionsIIF is the most common method for ANA screening in clinical laboratories.ELISA is also used in some laboratories.The two methods reported satisfying results in ANA test.The detection of anticentromere antibodies is improved.But the results of ANA titer reported are unsatisfactory. ANA detection in routine practice needs to be improved by standardization.
4.The induction of systemic lupus erythematosus by human cytomegalovirus pp65
Yuan ZHANG ; Yang PAN ; Kuo ZHANG ; Rui ZHANG ; Jiehong XIE ; Jinming LI ; Lunan WANG
Chinese Journal of Microbiology and Immunology 2012;32(8):689-695
Objective To investigate the potential role of human cytomegalovirus lower matrix phosphoprotein 65 (HCMV pp65) in murine systemic lupus erythematosus (SLE).Methods The prokaryotic vector pET-28b and eukaryotic vector pcDNA 3.0 were constructed to express the HCMV pp65 protein.All the C57BL/6 mice were inoculated with pp65 eukaryotic vector intramuscularly five times at 2-week intervals and then were bled via the retro-orbital vein.Subsequently,indirect ELISA was used to evaluate the concentration of anti-pp65 IgG,anti-dsDNA and ANA.At the same time,IL-1 b,IL-6,and TNF-α were determined by competitive ELISA.Results The early onset of autoantibodies and an overexpression of IL-6 were observed in immunized male C57BL/6 mice.Conclusion HCMV pp65 triggers the deregulation of humoral immunity in C57BL/6 mice,which indicates that the immune responses induced by HCMV pp65 may be involved in the development of SLE.
5.Effects of general anesthesia combined thoracic paravertebral block on postoperative pain and fast track in single-port video-assisted thoracoscopic surgery
Yanling ZHU ; Jie PENG ; Youping WU ; Jiehong XIE ; Xingan ZHANG ; Weifeng TU
The Journal of Clinical Anesthesiology 2015;(12):1153-1156
Objective To explore the effects of general anesthesia combined thoracic paraverte-bral block on postoperative pain and fast track single-port video-assisted thoracoscopic surgery (VATS).Methods Thirty patients,including male 20 and female 10,received single-port VATS were randomly and equally divided into two groups:group C received general anesthesia only,and group T received ultrasound-guided thoracic paravertebral nerve block combined with general anesthe-sia.Both groups did not use the patient-controlled analgesia,if insufficient analgesia happened (rest-ing VAS scores>4),than used dezocine intravenously as additional analgesia (a single-dose 5-20 mg, no more than 120 mg per day).The Ramsay scores at 1,4,8,12 h after the surgery and the mechani-cal withdrawal threshold on the day before the surgery,at 4,8,12,24 h after the surgery were recor-ded.The first time of post-operation pain feedback,the consumption of dezocine in the first 24 h after surgery,the incidence rates of side effects,the first time off-bed and the hospital stays were also re-corded.Results Compared with group C,the Ramsay scores at 8,12 h postoperatively in group T significantly decreased (P <0.05),and the mechanical withdrawal threshold at 4,8 h postoperatively significantly increased (P <0.05).The first time of post-operation pain feedback in group T was sig-nificantly longer than group C (P <0.05).The consumption of dezocine in the first 24 h after surgery significantly decreased in group T (P <0.05).The first time off-bed and the hospital stays in group T were shorter than group C (P <0.05).Also,the incidence rates of nausea,vomiting in the first 24 h postoperatively were lower in group T (P < 0.05 ).Conclusion General anesthesia combined with single-injected thoracic paravertebral nerve block can effectively relieve the postoperative pain in pa-tients undergoing single-port VATS,reduce the consumption of opioids in the first 24 h postopera-tively,cutting down the occurring rates of adverse reactions,which was beneficial to early ambulate and shortened the hospital stays.
6.Analysis of the results of external quality assessment for hepatitis C virus RNA tests
Rui ZHANG ; Lunan WANG ; Kuo ZHANG ; Jiehong XIE ; Yu SUN ; Jinming LI
Chinese Journal of Laboratory Medicine 2013;(3):271-276
Objective To evaluate the performance of HCV RNA detection in the first EQA program in 2012 and analyze possible problems in clinical laboratories.Methods The panel consisting of 5 samples was distributed to 927 laboratories.Each panel contains one negative sample and 4 positive samples,which were virus-like particles calibrated by international standard.The pere ent agreements of all the laboratories for qualitative and quantitative results were calculated.Genomic means (GM) and standard deviations (s) of all laboratories and each reagent were calculated.The overall GM and the GM of each reagent were compared with expected results and correlation curves were calculated.Results The percent agreements of sample 1211,1212,1213,1214 for qualitative results wcrc 99.5% (403/405),98.5% (400/406),100.0% (405/405),100.0% (406/406),respectively.The percent agreement of the negative sample was 99% (401/405).The percent agreements of sample 1211,1212 and 1213 for quantitive results were similar,which were 93.8% (549/585),92.3 % (541/586) and 94.5% (554/586).However,the agreement of sample 1214 was only 87.7% (514/586)and the agreement of sample 1214 for reagent A was 67.2% (92/137).The overall GM agreed with expected results,while GMs of reagent C,E and G deviated from expected results.GMs of sample 1211,1212,1213 and 1214 reported by labs using reagent C were 4.22,3.56,5.16 and 5.90,respectively.GMs of sample 1211,1212,1213 and 1214 reported by labs using reagent E were 4.52,3.78,5.55 and 6.29,respectively.GMs of sample 1211,1212,1213 and 1214 reported by labs using reagent G were 4.83,4.36,5.72 and 6.56,respectively.Conclusions The overall results of HCV RNA qualitative and quantitative detection are satisfactory.However,some problems still exist,such as deviation of GM of some reagents,the interassay variability,systematic deviation and accidental deviation,which show that the quality of reagents should be improved.
7.External quality assessment of antinuclear antibodies titer report from clinical laboratories in 2012 in China
Rui ZHANC ; Pu WANG ; Lunan WANG ; Kuo ZHANG ; Jiehong XIE ; Jinming LI
Chinese Journal of Laboratory Medicine 2013;36(7):648-652
Objective To evaluate the agreement of antinuclear antibody (ANA) titer reported in clinical laboratories and analyze possible problems in clinical laboratories.Methods Experiment survey.The panel consisting of 5 samples was distributed to 533 laboratories.Each panel contains one negative sample and 4 positive samples,which were from individuals of autoimmune disease.ANA titer system was divided into traditional titer system with two-fold dilution and titer system with 3.2 times dilution.Clinical laboratories were required to report the ANA titers and initial screening dilution according to the standard used in routine work.Results were expressed as median titers and range for acceptable performance.As to titer system with two-fold dilution,acceptable performance on proficiency testing was defined by a result equal to median titer ± two two-fold dilutions.While as to titer system with 3.2 times dilution,acceptable performance on proficiency testing was defined by a result equal to median titer ± 3.2 times dilutions.The laboratories percentages with acceptable performance were calculated to evaluate their agreements.Results 412 laboratories reported ANA titer results,of which 11.9% (49/412)reported results with two-fold dilution titer system,88.1% (363/412)reported results with 3.2 times dilution titer system.The median titers of sample 1211,1212,1213 and 1215 reported with two-fold titer system were 1 ∶ 640,1∶ 320,> 1 ∶ 1280 and1∶ 160,respectively.The agreement within the median ANA titer reported with two-fold dilution titer system ranged from 24.5% (12/49) to 57.1% (28/49) and the lowest percentage of the results within the acceptable limits was 87.8% (43/49).The median titers of sample 1211,1212,1213 and 1215 reported with 3.2 times dilution titer system were 1 ∶ 1000,1∶ 1000,> 1 ∶ 3200 and 1 ∶ 320,respectively.The agreement within the median ANA titer reported with 3.2 times dilution titer system ranged from 63.3% (31/49)to 83.7% (41/49).The lowest percentage of the results within the acceptable limits was 98.0% (48/49).Conclusions The results of ANA titer reported are unsatisfactory.Standardization for reagent,microscopy,procedure and result interpretation is necessary to improve the agreement of ANA titer report in different laboratories.
8.Determination of serum urea by isotope dilution gas chromatography mass spectrometry:a candidate reference method
Tianjiao ZHANG ; Jiangtao ZHANG ; Chuanbao ZHANG ; Haijian ZHAO ; Jing WANG ; Jiehong XIE ; Donghuan WANG ; Cuihua HU ; Rong MA ; Ziyu SHEN ; Wenxiang CHEN
Chinese Journal of Laboratory Medicine 2008;31(5):536-539
Objective To develop a candidate reference method for the measurement of urea in human serum based on isotope dilution/gas chromatography/mass spectrometry.Methods [13C,15N2]Urea used as internal standard Was added to the serum sample and equilibrated with endogenous nonlabeled urea.The serum samples were treated with anhydrous ethanol to emove proteins by precipitation.The serum urea and labeled urea were converted into a trimethylsilyl derivative of 2-hydroxypyrimidine and analyzed by gas chromatography/mass spectrometry system with selected ion monitoring.The concentration of serum ureaWas calculated by the theory of bracketing method.Results The average value of within-run oefficient of vailation(CV),between-run CV and total CV of the procedure were 0.38%(ranged from 0.12%to 0.47%),O.62%(ranged form 0.49% to 0.87%)and 0.73%(ranged from 0.51% to 0.93%).Respectively.The analytical recoveries ranged from 99.37% to 100.95%.The resuhs of analyzing the certified refefence material SRM909b(Level Ⅰand Ⅱ)showed a bias less than 0.2%.Conclusion The procedure for measuring urea in serum is a highly accurate and precise method and can be used as a candidate reference method for serum urea assays.
9.Evaluation of matrix effect of processed materials in serum total glycerol measurements
Weiyan ZHOU ; Haijian ZHAO ; Jiangtao ZHANG ; Tianjiao ZHANG ; Jing WANG ; Jiehong XIE ; Rong MA ; Cuihua HU ; Donghuan WANG ; Wenxiang CHEN ; Chuanbo ZHANG
Chinese Journal of Laboratory Medicine 2008;31(5):568-573
Objective To evaluate the matrix effect of processed materials in serum total glycerol measurement and to assess the accuracy of routine test systems.Methods With an isotope dilution liquid chromatography tandem mass spectrometry method as the comparative method,matrix effects of 28 processed materials on 8 routine test systems were evaluated ccording to the NCCLS EP 14 protocol.The processed materials and 20 flesh patient specimens were analyzed with both the comparative method and each of the evaluated methods and results obtained with the two methods were plotted.Two-tailed 95% prediction intervals for the mean of the flesh patient specimen were computed and results on the processed aterials were compared with these intervals for evaluation of matrix effect.Results with the two methods on fresh samples were also compared for assessment of the accuracy of the routine test systems.Results Some of the processed samples showed matrix effects on some of the routine test systems.The observed matrix effects were system-specific and aused either positive or negative biases.Calibration biases were also observed on some test systems.Conclusion Matrix effect and calibration bias have been observed in serum total glycerol measurements.Continued efforts are needed for improving the accuracy of serum total glycerol measurements.
10.Evaluation of matrix effects in serum urea measurements
Haijian ZHAO ; Tianjiao ZHANG ; Chuanbao ZHANG ; Weiyan ZHOU ; Jiangtao ZHANG ; Jing WANG ; Jiehong XIE ; Rong MA ; Cuihua HU ; Donghuan WANG ; Ziyu SHEN ; Wenxiang CHEN
Chinese Journal of Laboratory Medicine 2008;31(3):270-275
Objective To evaluate the matrix effects in serum urea measurements of external quality assessment(EQA)materials and commercial reference materials(calibrators or controls)on enzymatic methods and to verify the trueness of the enzymatic methods.Methods The Clinical and Laboratory Stadards Institute(CLSI)EP 14-A2 protocol was used for the evaluation of matrix effect.An isotope dilution gas chromatography mass spectrometry method was used as the comparative method.Twenty five fresh patient serum samples,15 EQA materials and 13 calibrators or controls were analyzed with 7 enzymatic methods (evaluated methods)and the comparative method and results were processed according to the protocol. The trueness of the evaluated methods were also assessed by comparing the fresh sample results obtained with the evaluated and comparative methods.Results Eight of 15 EQA materials and 3 of 13 calibrators or controls showed no matrix effects on all the 7 routine methods.One processed sample showed matrix effect on all the routine methods.Method dependent matrix effects of other materials were observed on other materials.Calibration biases were also observed on some enzymatic methods.Conclusions Matrix effects and calibration bias have been observed in serum urea measurements.Continued efforts are needed for improving the accuracy and the comparability of serum urea measurements.