1.Analysis of the Histopathology of ASCUS Diagnosed by Liquid-based Cervical Cytology
Jing PING ; Donghua ZHOU ; Jie LIU ; Jie TIAN ; Yan QIN
Journal of Kunming Medical University 2013;(12):65-67
Objective To analyze the histopathology of patients with atypical squamous cells of undetermined significance (ASCUS),and provide evidence for further classification and clinical treatment of ASCUS.Methods The histopathology of cervical biopsy specimens from 249 patients with ASCUS diagnosed by liquid-based cervical cytology examination was analyzed retrospectively. Results Among the 249 ASCUS patients, the proportion of patients with inflammation was 34.14% (85/249), morphological change by human papillomaviral infection was 19.28%(48/249), CIN I was 32.53%(81/249),CIN II was 8.84%(22/249),CIN III was 3.21%(8/249), infiltrating squamous cell carcinoma was 1.20%(3/249),and endometrioid adenocarcinoma was 0.80%(2/249) . Conclusion It is very important to to further definitude the diagnosis of ASCUS, because a certain proportion of cervical cancer and precancerous leisions woud be confirmed.
2.Design and Construction of an Embedded Telemetry System for Potentiometric Sensors
Taichun QIN ; Xiaogang LI ; Jie HAO ; Ping YU ; Lanqun MAO
Chinese Journal of Analytical Chemistry 2015;(3):457-462
A new embedded telemetry system for potentiometric sensors was developed. The system consisted of a transmitter unit, a receiver unit and a personal computer ( PC) . The transmitter unit included a current amplifier, a∑-Δanalog-to-digital converter ( ADC) , a microcontroller unit ( MCU) and a radio module. The receiver unit was composed of a radio module, a microcontroller unit and a serial-to-USB converter module. The receiver unit was connected to an upper computer via a universal serial bus ( USB ) . The embedded software written in C language controlled the signal acquisition and transmission. The computer software written in LabVIEW language was used for data storage and display. The range of the acquisition voltages was from-1. 17 V to +1. 17 V. In order to verify the accuracy and reliability of this system, a control experiment had been done with this system and a digital multimeter. Moreover, a response test of acidity changes had been done with the self-made H+ selective electrode. The results showed that the accuracy of this system could be up to 0. 1 mV and it had strong anti-noise ability. The square of the linear correlation coefficient of the response of the changes in pH values was 0 . 998 . The curve of the results measured by this system was consistent with that measured by the commercial electrochemical analyzer. The system was built with standard hardware components and the size of the transmitter unit was only 29 mm×14 mm×11 mm. It can be easily used for remote and real-time detection for the potentiometric sensor.
4.Sturge-Weber syndrome: report of a case.
Xue-qin CHEN ; Ni CHEN ; Xiao-jie WANG ; Ping HUA ; Ji-min GU ; Qiao ZHOU
Chinese Journal of Pathology 2006;35(8):503-504
5.Fever and splenic lesion.
Wen-yan ZHANG ; Gan-di LI ; Xiao-jie WANG ; Hui QIN ; Wei-ping LIU
Chinese Journal of Pathology 2010;39(4):270-271
Adult
;
Antineoplastic Combined Chemotherapy Protocols
;
therapeutic use
;
CD56 Antigen
;
metabolism
;
Cyclophosphamide
;
therapeutic use
;
Doxorubicin
;
therapeutic use
;
Fever of Unknown Origin
;
etiology
;
Humans
;
Lymphoma, Extranodal NK-T-Cell
;
complications
;
metabolism
;
pathology
;
therapy
;
Male
;
Prednisone
;
therapeutic use
;
Splenectomy
;
Splenic Neoplasms
;
complications
;
metabolism
;
pathology
;
therapy
;
Vincristine
;
therapeutic use
;
Young Adult
6.Comparison of robot assistant radical prostatectomy by transperitoneal versus extraperitoneal approach
Dan XIA ; Ping WANG ; Jie QIN ; Taile JING ; Sunyi YE ; Shuo WANG
Chinese Journal of Urology 2016;37(3):165-168
Objective To compare the safety and oncological results of robot-assisted laparoscopic radical prostatectomy performed between transperitoneal and extraperitoneal approach.Methods 79 patients underwent transperitoneal robot-assisted laparoscopic radical prostatectomy (Tp-RLRP).The other 86 consecutive patients went through extraperitoneal robot-assisted laparoscopic radical prostatectomy (Ep-RLRP).Results All procedures were performed successfully without conversion.Total procedure time for Ep-RLRP was shorter than it for Tp-RLRP[(218.1 ± 54.4) min vs.(180.2 ± 47.1) min,P < 0.001].Docking time for Ep-RLRP was longer than Tp-RLRP [(21.5 ± 7.1) min vs.(19.5 ± 5.7) min,P < 0.001] Blood lost of Tp-RLRP was lesser than Ep-RLRP[(122.4 ± 71.0) ml vs.(140.4 ± 90.7) ml,P < 0.05].There were no significant differences between two groups in terms of bowel function recovery,drainage tube reserve,foley catheter duration,etc.There were 19 patients (24.1%)and 4 patients (4.7%)were suffered lymph leakage in two groups separately,P < 0.001.One delayed vesiclurethra hemorrhagic patient and one mesenteric torsion patient were happened in Tp-RLRP group.There were no significant differences between two groups in terms of surgical margin,biochemical recurrence and urine continence.Conclusion Compared to Tp-RLRP,Ep-RLRP can provide similar short-term oncological control,recovery of postoperative urine continence,shorter operation time and lower complication rates.
7.Design and Implementation of Embedded Telemetry System for Amperometric Detection
Xiaogang LI ; Binqian GUO ; Taichun QIN ; Jie HAO ; Ping YU ; Lanqun MAO
Chinese Journal of Analytical Chemistry 2016;44(9):1465-1470
A new micro embedded telemetry system was developed for the amperometric sensing detection. Its output voltage range was ±0. 5 V and resolution was<1 mV. The current acquisition range was ±1μA and the minimum resolution was 0. 2 nA. This telemetry system was designed based on microprocessor ADuCM360, including a potentiostat, a current detection module and a radio module. And the size was only 24 mm × 13 mm × 11 mm. The computer software written in LabVIEW language was used for data storage and display. In order to verify the accuracy and reliability of this system, an electrical performance test was performed. The current response for ascorbic acid with different concentration was recorded by using the telemetry system. The potential of working electrode was set as 30 mV, and the current response of ascorbic acid electrode had a good linear relationship with its concentration within the concentration range of 50-300 μmol/L. Linear equation was I(nA) = 2. 98CAA(μmol/L)-137. 39, and linear correlation coefficient R2=0. 984. Moreover, the applicability of the instrument in the study for living animals was explored by using the cerebral ischemia as model.
8.Establishment of assessment of rabbit model of total limbal stem cell deficiency
Hong-qin, KE ; Lei, LIU ; Jing, LI ; Hu-jie, WANG ; Dong-ping, LI
Chinese Journal of Experimental Ophthalmology 2013;(2):151-155
Background The deficiency of limbus stem cells will cause various kinds of the disorder of eye surface,in serious condition,it will lead to corneal conjunctivalization,chronic inflammation,lasting deficiency of corneal epithelium and corneal opacity accompanying long-term visual loss.Objective The aim of this study was to investigate how to establish and evaluate the successful model of total limbal stem cell deficiency (LSCD).Methods Twenty Japanese white rabbits aged 3-5 months were selected.The limbus corneal epithelium was removed from 1 mm inner to 2 mm outer of the limbus 100-150 μm in deep,and the total central epithelium and shallow stroma were simultaneously removed in the left eyes using scalpel.The experimental eyes were examined by slitlamp 2,3,4,5 weeks after operation,and the inflammatory score was performed according to corneal opacity,corneal neovascularization and corneal flurescein dye using international universal rating criteria of LSCD model.Cornea tissue was obtained in various time points mentioned above to examine the structural change and goblet cells.The expression of cytokeratin 3(CK3) in the cornea was detected using indirect immuno-fluorescence staining.Fisher Exact Probability method was used to compare the successful rate of models in different time points.Results The successful rate of models rate was 12.5%,62.5%,81.3% and 87.5%,respectively 2,3,4,5 weeks after operation,showing a significant difference between the 3-week group and 2-week group (P =0.009).However,no significant differences were found in the model successful rate between the 3-week group and the 4-week group,the 4-week group and the 5-week group (P =0.465,0.200).There was a little difference between the 3-week group and the 5-week group(P=0.049).The mean time of achieving successful model was(3.21 ±0.80) weeks.The result of hematoxylin & eosin staining showed the edema of cornea stroma,a mass of inflammatory cells infiltration and new vessels.Goblet cells could be found by Periodic acid-Schiff staining 5 weeks after operation.Expression of CK3 was absent in the corneas of successful model eyes.Conclusions The LSCD model can be successfully established by cutting off the epithelium of limbus and central cornea,and the average time of model formation is about 3.2 weeks.
9.Clinical value of three-dimensional contrast-enhanced ultrasonography in evaluation of hepatic arteries anatomy types
Mei, LIAO ; Rong-qin, ZHENG ; Jie, REN ; Er-jiao, XU ; Ping, WANG ; Ren, MAO
Chinese Journal of Medical Ultrasound (Electronic Edition) 2010;07(12):2063-2068
Objective To assess the value of three-dimensional contrast-enhanced ultrasonography (3D-CEUS) in evaluation of hepatic arteries variants.Methods Both two-dimensional contrast-enhanced ultrasonography (2D-CEUS) and 3D-CEUS were used to assess 30 patients including living donor candidates and patients with upper abdomen tumors.The reference standard was operation or CTA or DSA or MRA,and the accuracy for detecting hepatic artery variants provided by the two methods was evaluated.Arterial anatomic types were defined by using Michels classification.Results The total accuracy for detecting hepatic artery anatomy types by 2D-CEUS was 40.0% (12/30),while 83.3% (25/30) by 2D-CEUS.For convention anatomy types the accuracy on 2D-CEUS and 3D-CEUS were 40.9%(9/22)and 90.9%(20/22),respectively.The difference was statistically significant (P<0.05).For anatomy variants types the accuracy on 2D-CEUS and 3D-CEUS were 37.5%(3/8)and 62.5%(5/8),respectively.No significant difference between these two methods was observed.Conclusion 3D-CEUS was a new method in diagnosis of hepatic arteries anatomy types with practical clinical value in evaluation of the living liver donors.
10.Changes and Significance of Serum High-Sensitivity C Reactive Protein and Platelet Parameter Levels in Newborns with Hypoxic-Ischemic Encephalopathy
ying, SHAN ; cheng-zhong, ZHENG ; jiong, QIN ; jie, NIU ; yang-ping, ZUO ; jia, HAO
Journal of Applied Clinical Pediatrics 2004;0(12):-
Objective To explore the changes of high-sensitivity C reactive protein(hs-CRP) and platelet parameter levels in newborns with hypoxic-ischemic encephalopathy(HIE)and its clinical significance.Methods Thirty-five infants with HIE and 16 healthy newborns were selected as study cases and controls respectively by automantc biochemistry analyzer.Serum hs-CRP content was measured by reaction rate method;Platelet parameter levels were detected by collecting blood samples from peripheral vascular of heel,and the activity of creatine kinase(CK),creatine phosphokinase isoenzyme(CK-MB),lactate dehydrogenase(LDH),alpha-hydroxybntyric dehydrogenase(?-HBDH),alanine transaminase(ALT),aspartate aminotransferase(AST) were assayed as well.Results 1.The hs-CRP levels in newborns with HIE increased obviously in acute stage,and significant difference were observed compared with controls(P0.05).2.PLT in newborns with HIE decreased significantly in acute stage compared with that of controls(P0.05).3.The values of CK,CK-MB,LDH,?-HBDH,AST,ALT in newborns with HIE were significantly higher than those in controls in acute stage(P