1.Clinical Effects of Levofloxacin Eyedrops in the Treatment of Acute Bacterial Conjunctivitis and Keratitis
Changming YUAN ; Jiawen LI ; Liling ZHANG ; Qiaoshan GUO ; Yan YANG
China Pharmacy 2001;12(6):264-265
OBJECTIVE: To observe the therapeutic effects of 0.3% levofloxacin eyedrops on the acute bacterial conjunctivitis and keratitis.METHODS: The patients were randomly divided into treated group and control group.They were given 0.3% levofloxacin and 0.3% ofloxacin eyedrops respectively.The effects were compared between two groups.RESULTS: From April 1998 to December 1998, 132 cases were enrolled in the study: treated group 67 cases, control group 65 cases.The positive rates of bacterial culture were over 80% in both groups.It showed that there was no significant difference between two eyedrops in the curative and effective rates, but the mean cure day of keratitis in levofloxacin group was significantly shorter than that in ofloxacin group.CONCLUSION: Levofloxacin eyedrops is effective and safe in treating bacterial conjunctivitis and keratitis, and the therapeutic course is short and no obvious ARDs occur.
2.Analysis of related risk factors of elderly T2DM patients with low-extremity arterial disease
Xuebin TAO ; Yuan WU ; Yuping ZENG ; Jiawen ZHU ; Xiaoying MU ; Lihua DONG
Chinese Journal of Practical Nursing 2012;(35):12-14
Objective To investigate the risk factors for lower extremity peripheral arterial disease (LEPAD) in elderly patients with Type 2 diabetes mellitus(T2DM).Methods To detect ankle brachial index (ABI) of 356 elderly patients with T2DM,and analyze whether risk factors had correlation with ABI.Results We found that age,systolic blood pressure,HbAlc,2-hours post-prandial (2hpp) plasma glucose had inverse correlation,yet 2hpp C-peptide plasma level,2-hpp insulin level had positive correlation with ABI by bivariate correlation test.Conclusions Age,systolic blood pressure,2hpp plasma glucose,2hpp C-peptide plasma level,2hpp insulin level were related with lower extremity arterial disease in the elderly with T2DM,among which age was the most important risk factor for LEPAD.
4. Trichloroethylene-induced abnormal methylation on promoter region of SET in hepatic L-02 cells
Jiawen RUAN ; Zhihong CHEN ; Weixue LU ; Hang ZHANG ; Xiaohu REN ; Xinfeng HUANG ; Jianhui YUAN ; Yungang LIU ; Jianjun LIU
Chinese Journal of Industrial Hygiene and Occupational Diseases 2018;36(3):165-168
Objective:
To explore the trichloroethylene-induced alteration of methylation on the promoter region of SET and related mechanisms in hepatic L-02 cells.
Methods:
L-02 cells were treated with different concentrations of TCE(0 mmol/L, 1 mmol/L, 2 mmol/L, 4 mmol/L, 8 mmol/L) for 24 h. The genomic DNA were then extracted and modified by bisulfite sodium. The DNA methylation was then analyzed using bisulfite sequencing PCR (BSP).
Results:
The overall methylation on promoter region of SET was decreased along with the increased concentrations of TCE in hepatic L-02 cells. Moreover, 73 CpG islands were found abnormally altered, among which 9 were predicted in transcriptional factor binding regions.
Conclusion
The decreased levels of CpG islands in the transcriptional factor binding region may contribute to the elevation of SET in TCE-induced hepatotoxicity.
5.Determination of dimethyl carbonate in workplace air by solvent desorption-gas chromatography
Jiaheng HE ; Jing YUAN ; Weifeng RONG ; Jiawen HU ; Ruibo MENG ; Guanlin CHEN ; Banghua WU
China Occupational Medicine 2023;50(2):181-184
6.Analyzing the monitoring results of occupational hazards in the workplace of key industries in Guangdong Province, 2020-2023
Weifeng RONG ; Zuofei XIE ; Jiaheng HE ; Jing YUAN ; Jiawen HU ; Ruibo MENG ; Banghua WU
China Occupational Medicine 2024;51(1):54-59
ObjectiveTo understand the monitoring result of occupational hazard in the workplace of key industries in Guangdong Province from 2020 to 2023. Methods The data of occupational hazards in the workplace of 20 key industries in Guangdong Province from 2020 to 2023 were collected from the “Workplace Occupational Hazard Monitoring System” of the Chinese Disease Prevention and Control System subsystem. The monitoring result of occupational hazard factors, occupational health training, occupational health examination, occupational protection, detection of occupational hazardous agents such as dust, chemical substances and noise were analyzed. Results A total of 13 058 enterprises from key industries were recruited as the monitoring subjects in Guangdong Province. There were 290 large-, 1 342 medium-, 7 635 small-, and 3 791 micro-enterprises, with small and micro-enterprises accounting for 58.5% and 29.0% of the total, respectively. A total of 7 542 enterprises exceeded the national standard in the detection of occupational hazards, with a rate of 57.8%. A total of 1 942 517 workers from 13 058 enterprises were recruited, with 835 567 workers were exposed to occupational hazards, with a rate of 43.0%. The rate of occupational health training for enterprise leaders, occupational health management personnel, and workers was 71.9%, 73.8%, and 86.5%, respectively. The abnormal rate of occupational health examinations for workers exposed to noise, dust, and chemical agents was 2.0%, 0.6%, and 1.0%, respectively. The distribution rate of dust masks, anti-poisoning masks or face masks, and noise prevention earplugs or earmuffs was 83.3%, 71.3%, and 77.8%, respectively. The rate of installation of dust prevention facilities, anti-poisoning facilities, and noise prevention facilities was 85.6%, 81.2%, and 50.1%, respectively. The rate of exceeded the national standard of dust, noise in the worksites/types and workplaces showed a decreasing trend year by year (all P<0.01), while the rate of exceeded the national standard of chemical agents in worksites/types and workplaces showed an increasing trend year by year in various occupational hazards (all P<0.01). Conclusion Occupational hazards in the workplace of key industries in Guangdong Province are relatively common. The proportion of workers exposed to occupational hazards is relatively high. It is necessary to further improve the use of noise prevention facilities and protective equipment, strengthen occupational health training for enterprises throughout the province and regularly monitor occupational hazards to reduce the risk of occupational diseases.
7.Establishment of a method for detecting peripheral blood circulating brain microvascular endothelial cells, a novel biomarker for blood-brain barrier injury.
Yan LI ; Lei DU ; Lin YUAN ; Dexi CHEN ; Jiawen QIU ; Xiaolong HE ; Hong CAO ; Shenghe HUANG
Journal of Southern Medical University 2014;34(12):1733-1737
OBJECTIVETo establish a method for detecting circulating brain microvascular endothelial cells (cBMECs), a novel biomarker of blood-brain barrier (BBB) injury.
METHODSBlood samples were collected from 33 patients with AIDS encephalitis and 13 healthy subjects for detection of cBMECs, cECs and EPCs using magnetic affinity isolation and immune identification technology.
RESULTSThe numbers of cBMECs, cECs and EPCs were significantly higher in the AIDS patients than in the control subjects (t=4.298, P<0.01; t=4.886, P<0.01; t=4.889, P<0.01). An significant association was also noted between HIV load and cBMEC number (r=0.928, P<0.01).
CONCLUSIONWe have successfully established a method for detecting peripheral blood cBMECs, which can be of important value in non-invasive assessment of BBB injury.
Acquired Immunodeficiency Syndrome ; physiopathology ; Biomarkers ; Blood-Brain Barrier ; pathology ; Cell Separation ; methods ; Cells, Cultured ; Endothelial Progenitor Cells ; cytology ; Humans
8.Determination of two isomers of tetrachloroethane by solvent desorption-gas chromatography in workplace air
Jing YUAN ; Weiming XIE ; Fan WU ; Jiaheng HE ; Jiawen HU ; Ruibo MENG ; Weifeng RONG ; Banghua WU ; Chuan WU
China Occupational Medicine 2023;50(2):185-188
9.Qualitative analysis of volatile organic components in chemicals using headspace gas chromatography-mass spectrometry
Ruibo MENG ; Weifeng RONG ; Jiawen HU ; Jiaheng HE ; Jing YUAN ; Jingjing QIU ; Zuokan LIN ; Ziqun ZHANG ; Banghua WU
China Occupational Medicine 2023;50(3):325-329
Objective To establish a rapid qualitative analysis method for volatile organic components in chemicals. Methods Headspace gas chromatography-mass spectrometry was used to qualitatively determine 19 volatile organic components, including benzene, 1,2-dichloroethane, and n-hexane, in chemicals. Different sample amounts, heating temperatures, heating times, and sample volumes were analyzed to assess their effects on detection results and optimize sampling conditions. Results Based on the set chromatography, the optimal sampling process of this method was as follows: 5.0 g sample in a 20.0 mL headspace bottle, incubated at 40 ℃ for 30 minutes in a constant-temperature drying incubator, and a 1.00 mL headspace gas injection. The within-run and between-run relative standard deviations of all components ranged from 0.00% to 21.05% and 0.00% to 33.33%, respectively. The samples stored in sealed glass containers were stable at room temperature for at least 60 days. Conclusion This method offers simplicity, good reproducibility, and stability, making it suitable for rapid qualitative analysis of volatile organic components in chemicals.
10.Simultaneous determination of six aniline compounds in workplace air by high performance liquid chromatography
Ruibo MENG ; Jingjing QIU ; Weifeng RONG ; Weimin XIE ; Jing YUAN ; Jiaheng HE ; Jiawen HU ; Ziqun ZHANG ; Zuokan LIN ; Fan WU ; Banghua WU
China Occupational Medicine 2023;50(4):441-446
Objective To establish a high performance liquid chromatography (HPLC) method for simultaneous determination of six aniline compounds (ADs) in workplace air. Methods GDH-1 air sampling tube was used to collect six co-existing ADs such as aniline, o-toluidine, N-methylaniline, m-methylaniline, p-methylaniline and N,N-dimethylaniline in the vapor and aerosol of workplace air. The samples were desorbed and eluted using a methanol solution containing 1.00% ammonia water, followed by separation on a C18 chromatographic column and detection using a diode array detector. Results The quantification range of the method was 0.19 -253.50 mg/L, with the correlation coefficient of 0.999 9 for all six ADs. The minimum detection range was 0.02-0.06 mg/m3, and the minimum quantitation range was 0.04-0.19 mg/m3 [both calculated for a 15.0 L sample with a desorption (elution) solution volume of 3.00 mL]. The average desorption and elution efficiencies were 92.15%-104.41% (silica gel) and 94.29%-104.29% (filter membrane). The intra-assay relative standard deviation (RSD) ranged from 0.90%-9.72% (silica gel) and 0.57%-6.96% (filter membrane). The inter-assay RSD ranged from 2.03%-9.78% (silica gel) and 2.50%-8.62% (filter membrane). The samples were stable at room temperature for seven days. Conclusion This method can be used for the simultaneous determination of six ADs in workplace air.