1.Preparation and Quality Control of Slow-released Implantable Adriamycin Tablets
Jiaqing FAN ; Yunshu TU ; Yong DING
China Pharmacy 2001;0(11):-
OBJECTIVE:To prepare the slow_released implantable adriamycin tablets and to establish the standard of quality control METHODS:Slow_released implantable adriamycin tablets were prepared with polylactic acid as carrier and were implanted into rabbit’s eyes for observation UV_spectrophotometer was used to determine the content of adriamycin in impla_ntable tablet RESULTS:The average weight of the implantable tablet was 4 56mg The absorption value and concentration showed a good linearity in a range of 0 86~10 72?g/ml(r=0 9 993) The average recovery was 99 20%,RSD=0 43%(n=5) CONCLUSION:The slow_released adriamycin tablet is simple in preparation technic and feasible in quality control method
2.Literature Analysis of Ceftizoxime-induced Hemolytic Anemia
Wangdong FAN ; Dandi CHEN ; Jiaqing ZHOU ; Li JIANG
China Pharmacy 2016;27(25):3595-3597
OBJECTIVE:To provide reference for clinical prevention and treatment of ceftizoxime-induced hemolytic anemia by investigating the situation of ceftizoxime-induced hemolytic anemia. METHODS:Using Chinese and English“ceftizoxime”“he-molysis”and other words as key words,related literatures during 1986-2015 were retrieved from CNKI,Wanfang database and PubMed database. Those literatures were analyzed statistically in respects of general information,clinical drug use and manifesta-tion,occurrence time and outcome,etc. The mechanisms of hemolytic anemia were analyzed to put forward prevention and treat-ment measures. RESULTS & CONCLUSIONS:A total of 11 literatures were retrieved,including 4 foreign literatures and 7 domes-tic ones. There were 15 cases in total,including 5 foreign cases and 10 domestic cases. According to the patient’s age,there were 7 cases of infants,4 cases of the elderly,3 cases of middle-aged people and 1 case of youth. The hemolytic anemia often occurred on the 2-7 day(8 cases). Most of the patients were improved after treatment,but there were 3 patients who died. The mechanism of hemolytic anemia mainly included the production of immune complex and non-immunologic protein adsorption. It is suggested to investigate allergic reaction history,pay attention to sensitization test on skin,select suitable drug dosage and avoid drug combina-tion. The patient’s medications should be monitored closely. Once hemolytic anemia occurs,it should be immediately stop using the drug and take appropriate measures as hormone treatment,comprehensive treatment,blood transfusion treatment,to avoid en-dangering the life safety of patients.
3.Evaluation and clinical significance of coronal bone structure matching in distal radius fractures
Xin ZHANG ; Jiaqing JI ; Ying YAO ; Shanzhu LI ; Jiaqian ZHOU ; Yong YIN ; Feng YUAN ; Jian FAN
Chinese Journal of Orthopaedics 2021;41(6):368-375
Objective:To study the coronal bone structure matching of distal radius in normal population and some patients with postoperative distal radius fracture, and to explore the clinical significance of coronal bone structure reduction of distal radius fracture.Methods:CT scans of 80 asymptomatic wrists were performed. Mimics 20.0 and 3-Matic research software were used to measure the matching data of coronal bone structure of the distal radius. Total of 44 patients with distal radius fractures treated with open reduction and volar plate fixation were collected. According to the data coronal bone structure of the distal radius, the matching group was in the normal range, and the mismatching group was less than the normal range. X-ray films were used to evaluate fracture healing, humeral height, ulnar angle and palm tilt angle at 3 months and 12 months after operation. The clinical indexes of wrist pain, wrist function, grip strength and activity were recorded in 2 groups. The DASH score was used for evaluation, and statistical comparisons was made between the two groups of related indicators.Results:The coronal bone structure matching value of the distal radius in 80 normal adults was 45.0%±16.2%. All the 44 patients with distal radius fracture were followed up for an average of 16 months. The postoperative wound healing was good, and the bone healing standard was reached 3 months after the operation. 3 months after surgery, radius height, ulnar deviation angle and palmar inclination angle of the mismatched group were all smaller than those of the matched group, but the differences had no statistical significance. The pronation angle in the mismatched group (68.82°±11.62°) was lower than that in the matched group (76.91°±9.14°), and the difference was statistically significant ( t=2.567, P=0.014). The DASH score in the mismatched group (15.53±2.36) was higher than that in the matched group (13.62±2.52), and the difference was statistically significant ( t=2.591, P=0.013). 12 months after surgery, the VAS score of the matched group (2.08±2.95) was less than that of the mismatched group (2.95±1.24), and the difference was statistically significant ( t=2.348, P=0.024). There was no significant difference in wrist range of motion, grip strength and DASH score between the two groups. Conclusion:The coronal bone structure matching of distal radius is about 45.0% in normal population. Early wrist dysfunction, limited pronation, and wrist pain may occur when the postoperative matching degree of the distal radius fracture is not within the normal range.
4.Characterization and biocompatibility of human-like collagen-hyaluronic acid scaffold for blood vessel.
Xiujuan SUN ; Daidi FAN ; Chenhui ZHU ; Xiaoxuan MA ; Yane LUO ; Lan CHEN ; Jiaqing GUO
Chinese Journal of Biotechnology 2009;25(4):591-598
Human-like collagen (HLC) was cross-linked with hyaluronic acid by genipin in different ratio. The concentrations of hyaluronic acid in the mixture were 0, 0.01%, 0.05% and 0.1%. The blood vessel tubular grafts were then fabricated by freeze-drying. Microstructure, element composite, mechanical properties, cytotoxicity grade, and biocompatibility of different vascular scaffold groups were studied by scanning electron microscope (SEM), X-ray photoelectron spectroscopy (XPS), tensile test, burst pressure experiment, cytotoxicity experiment, endothelial cells planted in blood vessel scaffolds and hypodermic embedding of mice. The results showed that HLC-HA (0.05%) tubular scaffold exhibited interconnected well-distributed and porous structure and porosity of 94.38%; achieved the desirable mechanical property with stress of (1000.8 +/- 7.9) kPa and burst pressure of (1058.6 +/- 8.2) kPa, hypocytotoxicity, favourable cytocompatibility, hisocompatibility and disposition of degradation.
Adhesives
;
chemistry
;
Animals
;
Biocompatible Materials
;
chemistry
;
Biomimetic Materials
;
chemistry
;
Blood Vessels
;
drug effects
;
physiology
;
Collagen
;
chemistry
;
Humans
;
Hyaluronic Acid
;
chemistry
;
Iridoid Glycosides
;
Iridoids
;
chemistry
;
Materials Testing
;
Mice
;
Tissue Engineering
;
instrumentation
;
methods
;
Tissue Scaffolds
5.Stabilization of dorsal intra-articular fragment in distal radius fracture after volar locking plate fixation
Jiaqing JI ; Jan WANG ; Xin ZHANG ; Feng YUAN ; Jian FAN
Chinese Journal of Orthopaedic Trauma 2022;24(4):345-349
Objective:To explore the risk factors that may affect the stabilization of dorsal intra-articular fragment in distal radius fracture after volar internal fixation.Methods:A retrospective analysis was performed of the patients with distal radius fracture who had been treated by volar internal fixation at Department of Traumatic Orthopedics, Tongji Hospital Affiliated to Tongji University from July 2016 to July 2020. After 3D reconstruction of their preoperative CT scans by software Mimics 20.0, 66 patients with a dorsal intra-articular fragment were screened out. They were 31 males and 35 females, aged from 23 to 78 years (average, 53.4 years). By the AO classification, there were 17 case of type C1, 22 cases of type C2, and 27 cases of type C3. The displacement of dorsal intra-articular fragment was judged by X-ray observation on postoperative day 2 and X-ray follow-up at the outpatient department. The 13 patients with displacement of dorsal intra-articular fragment>2 mm were assigned into a displacement group while the other 53 ones into a displacement-free group. The 2 groups were compared in terms of preoperative general data and anatomical data of the dorsal intra-articular fragment (total preoperative displacement, radius-ulnar length, dorsal-volar length, aspect ratio, proximal-distal length and volume) to analyze the correlations between them and displacement.Results:There was no significant difference in preoperative general data (age, gender, affected side, cause of injury or AO classification) between the 2 groups, showing comparability between groups ( P>0.05). All patients were followed up for 6 to 24 months (mean, 14 months) after surgery. There were no postoperative complications like neurovascular lesion or infection. None of the patients in the displacement group underwent revision surgery, and the fractures healed successfully during the postoperative follow-up. The total preoperative displacement in the displacement group was(10.0±1.3) mm, significantly larger than that in the displacement-free group [(7.8±1.5) mm]; the radius-ulnar length in the displacement group was (8.2±1.3) mm, significantly shorter than that in the displacement-free group [(10.8±2.3) mm]; the aspect ratio of the fragment in the displacement group was 1.2±0.2, significantly lower than that in the displacement-free group (1.4±0.2); the fragment volume in the displacement group was (690.5± 201.4) mm 3, significantly smaller than that in the displacement-free group [(995.8±295.0) mm 3]. There were significant differences in the above items between the 2 groups ( P<0.05). Conclusion:The total preoperative displacement, radius-ulnar length, aspect ratio and volume of a dorsal intra-articular fragment are important factors which may affect the displacement of the dorsal fragment after volar internal fixation.
6.A comparative study of three internal fixation techniques for comminuted fractures of humeral greater tuberosity
Jiaqing JI ; Han WU ; Tao CAI ; Feng YUAN ; Jian FAN
Chinese Journal of Orthopaedic Trauma 2023;25(8):649-656
Objective:To compare the clinical outcomes between anatomical locking plate, proximal humerus internal locking system (PHILOS) and anatomical locking plate combined with suture anchors in the treatment of comminuted fractures of humeral greater tuberosity.Methods:A total of 33 comminuted fractures of humeral greater tuberosity were surgically treated from October 2016 to October 2021 at Department of Orthopedics, Tongji Hospital Affiliated to Tongji University. There were 20 males and 13 females, with an age of (53.5±13.6) years. They were assigned into 3 groups according to different internal fixation techniques. Group A of 12 cases was subjected to fixation with anatomical locking plate via the deltoid approach, group B of 10 cases subjected to fixation with PHILOS via the pectoralis major and the deltoid approaches and group C of 11 cases subjected to fixation with anatomical locking plate combined with suture anchors via the deltoid approach. The operation time, intraoperative blood loss, range of shoulder motion, Constant-Murley shoulder score, visual analogue scale (VAS) and postoperative complications were compared between the 3 groups.Results:The 3 groups were comparable because there was no significant difference between them in the general clinical data ( P>0.05). The follow-up duration for all patients was (14.5±4.1) months. All fractures got united at the last follow-up. In groups A, B and C, respectively, the operation time was (57.9±7.8), (73.0±7.1) and (63.6±9.5) min, and the intraoperative blood loss (41.7±18.9), (82.0±22.9) and (46.4±13.6) mL, showing significant differences between the 3 groups ( P<0.05). The operation time and intraoperative blood loss in groups A and C were significantly less than those in group B ( P< 0.05). At the last follow-up, in groups A, B and C, respectively, the shoulder abduction was 144.0°±7.7°, 138.7°±10.7° and 148.5°±6.2°, showing significant differences between the 3 groups ( P<0.05). Group C was significantly better than group B ( P<0.05). There was no statistically significant difference in the forward flexion, external rotation, or internal rotation of the shoulder joint between the 3 groups ( P>0.05). The Constant-Murley scores in groups A, B and C, respectively, were (90.4±5.7), (86.1±6.6) and (93.1±3.4) points, showing significant differences between the 3 groups ( P<0.05). Group C was significantly better than group B ( P<0.05). The VAS scores in groups A, B and C, respectively, were 1 (0, 2), 1 (0, 2), and 1 (0, 1) point, showing insignificant differences between the 3 groups ( P>0.05). Group A had 1 case of shoulder joint stiffness and 1 case of fracture re-displacement complicated with acromial impingement syndrome, group B 1 case of shoulder joint stiffness and 3 cases of fracture re-displacement, but group C no post-operative complication. Conclusions:In the treatment of comminuted fracture of humeral greater tuberosity, all the 3 internal fixation techniques can lead to fine clinical outcomes. Conventional PHILOS may lead to relatively large trauma and a high incidence of postoperative complications. The anatomical locking plate may result in fine functional recovery of the shoulder due to advantages of less invasion, shorter operation time and fewer postoperative complications than PHILOS. The anatomical locking plate combined with suture anchors may lead to the best shoulder functional recovery and the least complications.
7.Internal fixation treatment of AO-C type distal radius fractures accompanied with a dorsoulnar fragment involving 1/8 to 1/3 of the articular surface of the lunate facet
Jiaqing JI ; Xin ZHANG ; Jikui QIAN ; Han WU ; Tao CAI ; Feng YUAN ; Jian FAN
Chinese Journal of Orthopaedics 2024;44(2):87-95
Objective:To explore the clinical outcome of internal fixation in the treatment of AO C-type distal radius fracture accompanied with dorsoulnar fragment involving 1/8 to 1/3 of the articular surface of the lunate facet.Methods:A total of 55 patients of AO C-type distal radius fracture accompanied with dorsoulnar fragment involving 1/8 to 1/3 of the articular surface of the lunate facet from July 2017 to July 2022 in Tongji Hospital Affiliated to Tongji University were retrospectively analyzed. In the volar plate group (volar locking plate treatment alone), there were 22 cases, 11 males and 11 females, aged 56.7±10.1 years, 10 C1 type, 7 C2 type and 5 C3 type. There were 15 patients in the volar plate+dorsal plate group (treated with volar locking plate combined with dorsal plate), including 6 males and 9 females, aged 55.7±8.1 years old, 4 C1 type, 5 C2 type and 6 C3 type. In the volar plate+dorsal screw group (treated with volar locking plate combined with dorsal screw), there were 18 cases, 8 males and 10 females, aged 53.5±11.6 years, 7 cases of C1 type, 5 cases of C2 type, and 6 cases of C3 type. The operation time, postoperative radiographic indicators, wrist range of motion (ROM), disability of arm, shoulder and hand (DASH) score, visual analogue scale (VAS) and postoperative complications were evaluated and compared between the three groups.Results:All operations were successfully completed. Patients were followed up for 14.9 ± 2.2 months (range, 12-18 months), and the fracture healing time was 12.4±2.3 weeks (range, 9-16 weeks). The operative time of patients in the volar plate group, volar plate+dorsal plate group and volar plate+dorsal screw group was 54.3±7.6 min, 70.7±5.9 min and 65.8± 7.1 min, respectively. Patients in the volar plate group had less operative time ( F=27.04, P<0.001). The residual displacement of the dorsoulnar fragment in sagittal, coronal, and axial CT scans in the three groups were (1.3±0.8 mm, 0.6±0.4 mm, 0.7±0.4 mm), (1.1±0.8 mm, 0.6±0.4 mm, 0.6±0.6 mm), (1.4±0.8 mm, 0.7±0.4 mm, 0.7±0.5 mm). The displacement of the dorsoulnar fragment of the two groups of combined volar and dorsal internal fixation was smaller than that of the volar plate group ( P<0.05). The ROM of wrist flexion of the three groups at 3 months after operation were 44.2°±4.6°, 47.7°±5.9°, 48.8°±5.1°, the ROM of wrist extension were 39.8°±6.2°, 44.3°± 4.6°, 44.7°±5.1°, the wrist DASH scores were 23.0±4.2, 20.1±4.1 and 19.4±3.0, and the VAS were 2.3±1.2, 1.6±1.3 and 1.3±1.0, respectively. The ROM of wrist flexion and extension and DASH score in volar plate+dorsal plate group were better than those in volar plate group ( P<0.05). The ROM of wrist flexion and extension, DASH score and VAS in the volar plate+dorsal screw group were better than those in the volar plate group ( P<0.05). There were no significant differences in terms of the wrist ROM, DASH score and VAS at 12 months after operation among the three groups ( P>0.05). There were 2 patients in the volar plate group with reduction loss, 3 patients with wrist chronic pain; 1 patient in the volar plate combined with dorsal plate group with dorsal tendon irritation, and no complications in the volar plate combined with dorsal screw group. Conclusion:For AO C-type distal radius fractures accompanied with a dorsoulnar fragment involving 1/8 to 1/3 of the articular surface of the lunate facet, the use of combined volar and dorsal internal fixation can improve the reduction accuracy and stability of the dorsoulnar fragment, and contribute to the early rehabilitation of postoperative wrist joint function. The effect of combined dorsal screw is comparable to that of dorsal plate internal fixation, but the complications of screw internal fixation are less.