1.CT and MRI manifestations of the intrathoracic ganglioneuroma
Yubao GUAN ; Weidong ZHANG ; Jianxing HE ; Qingsi ZENG ; Guoqin CHEN ; Yongxia LEI ; Yuan QIU ; Nanshan ZHONG
Chinese Journal of Radiology 2011;45(12):1136-1138
ObjectiveTo evaluate CT and MRI findings of the intrathoracic ganglioneuroma and to improve its diagnosis and differential diagnosis ability.MethodsClinical,CT( n = 14),MRI (n = 6) and pathology manifestations of 20 patients with the intrathoracic ganglioneuroma were retrospectively analyzed.All 20 cases had chest CT and MRI plain scanning and multiphase enhance scanning before operation.ResultsSeventeen of 20 lesions were located in posterior mediastinum,2 in pleura side and 1 in right thorax cavity.The CT value of the plain scans ranged from 20 to 40 HU ( mean 30.5 HU),Tubercle calcification were detected in four masses,one case with fat density was showed on CT scanning.After injecting contrast media,CT value ranged from 0 to 12 HU (mean 6.2 HU) in artery phase,ranging from 10 to 20 HU ( mean 14.3 HU) in delay phase.Five of 6 cases of MRI signals were homogeneously low intensity on T1 WI,1 case with fat signal was imhomogeneously low intensity on T1WI.Six cases were imhomogeneously high intensity on T2WI.A whorled appearance was visualized in one tumor on T2WI.The post-contrast enhancement MR images was slight enhancement imhomogeneously in artery phase and gradual increasing enhancement in delay phase.ConclusionOn CT and MR imaging,no enhancement or slight enhancement in artery phase and gradual increasing enhancement in delay phase are characteristic manifestations of ganglioneuroma in the thorax.
2.The sub-microsecond pulser applied for electroporation effect.
Yafang TAN ; Hongchun YANG ; Jianxing WU ; Xiaolin YANG ; Yi ZHANG ; Gang ZENG ; Xiaoyu ZHANG
Journal of Biomedical Engineering 2012;29(4):615-619
A sub-microsecond pulse generation applied for electroporation effects of tumor cell is presented in this paper. The principle of the generator is that the expected pulse waveform is intercepted from the RC discharge curve by controlling the on-off states of two IGBT modules with a synchronous controller. Experimental tests indicate that the generator can produce adjustable pulse waveform parameters with 0.5-3.5kV amplitude, 300-800 ns pulse duration, 1-400Hz repetition frequency rate, and it is suitable for the study of the electroporation effect experiments.
Animals
;
Cell Line, Tumor
;
Cell Membrane
;
Electricity
;
Electroporation
;
instrumentation
;
methods
;
Equipment Design
;
Microtechnology
;
instrumentation
;
Neoplasms
;
ultrastructure
3.Analysis of risk factors for intra-abdominal infection after hepatectomy for primary liver neoplasms
Yupeng TANG ; Xiaoling YU ; Yajuan LAI ; Jianxing ZENG ; Meiyi HUANG
Chinese Journal of Hepatobiliary Surgery 2022;28(12):881-885
Objective:To study the risk factors of intra-abdominal infection after hepatectomy in patients with primary liver neoplasms.Methods:The clinical data of patients with primary liver neoplasms who underwent hepatectomy at the Department of Hepatobiliary Surgery, Mengchao Hepatobiliary Hospital of Fujian Medical University from January 2019 to December 2021 were retrospectively analyzed. Of 1 229 patients who were enrolled, 48 patients developed postoperative abdominal infection. There were 45 males and 3 females, with age of 58.0 (45.0, 66.0) years old in the infected group. Forth-eight patients without postoperative abdominal infection were selected based on the random number formula to be allocated to the uninfected group to include 44 males and 4 females with age of 58.5 (48.5, 64.8) years old. The general data, preoperative and postoperative laboratory test results, types of liver neoplasms and hepatectomy, pathogenic infective microorganisms and their drug sensitivity tests were collected. Univariate analysis was used to analyze the related factors of intra-abdominal infection after hepatectomy, and significant factors were included in logistic multivariate regression analysis.Results:Of 24 pathogenic strains which were detected in the 143 samples of abdominal infection, the positive rate of culture was 16.78%(24/143). Multivariate logistic regression analysis showed that prealbumin <180 mg/L ( OR=3.757, 95% CI: 1.117-12.634), intraoperative blood transfusion ( OR=6.363, 95% CI: 1.301-31.113) and the time of drainage tube placement ≥7 d ( OR=31.098, 95% CI: 6.906~140.029) were independent risk factors of intra-abdominal infection after hepatectomy. Conclusion:Prealbumin <180 mg/L, intraoperative blood transfusion and the time of drainage tube placement ≥7 d were independent risk factors of intra-abdominal infection after hepatectomy for primary liver neoplasms.
4.Comparison of temperature rise curve and steady state temperature during thulium and holmium laser lithotripsy
Lei LIANG ; Bo XIAO ; Tianfu DING ; Xue ZENG ; Chaoyue JI ; Jianxing LI
Chinese Journal of Urology 2023;44(2):134-139
Objective:To compare the temperature rise curve and steady-state temperature of thulium and holmium laser in lithotripsy.Methods:This study was conducted from November to December 2021. Firstly, we designed an experimental water tank(10 cm×10 cm×10 cm) that can carry out constant temperature water bath, with a 8ml simulated renal pelvis, and can carry out constant velocity perfusion in the simulated renal pelvis. A 1 cm×1 cm×1 cm cubic artificial stone was placed in the simulated renal pelvis to perform 36.5℃-37.5 ℃ water bath. The simulated renal pelvis was closed with an oak plug, the temperature measuring probe and flexible ureteroscope were placed through the hole on the oak plug and entered into the simulated renal pelvis. Flexible ureteroscope was carried out by urologists. The lithotripsy lasted a total of 180 seconds for thulium and holmium laser respectively under different parameter settings (10 Hz×1.0 J, 10 Hz×2.0 J, 10 Hz×3.0 J, 20 Hz×0.5 J, 20 Hz×1.0 J, 20 Hz×1.5 J, the corresponding gravel power is 10 W, 20 W and 30 W respectively), the constant speed water pump flow rate was separate as the high flow rate group (35 ml/min) and low flow rate group (15ml/min), and leave a temperature probe 5mm around the optical fiber. Water temperature change during the lithotripsy was recorded by probes, the average of 10 temperature values of two probes measured every 5 seconds was taken as the water temperature value of this period, with a total of 216 time points in 6 parameter settings. Under the same parameter settings, the temperature of two lasers at each time point was plotted and compared to form the corresponding temperature rise curve. The average temperature in the last 30 seconds during lithotripsy in the record was used as the steady-state temperature, which of thulium and holmium laser lithotripsy was compared under the same parameter setting and the same water flow velocity. Finally, 43℃ was taken as the safety threshold temperature to evaluate whether the temperature of the two lasers during lithotripsy exceeds the safety threshold.Results:According to the temperature rise curve, the water temperature of thulium laser during lithotripsy was higher than that of holmium laser at 77.7% (168/216)of time points. At the flow rate of 15 ml/min, thulium laser was significantly higher than that of holmium laser at 10 Hz×1.0 J[(32.43±2.19℃)vs. (30.99±0.90)℃, P<0.01], 10 Hz×2.0 J[(41.21±3.30℃) vs. (38.13±1.26)℃, P<0.01], 10 Hz×3.0 J[(49.54±2.44)℃vs. (44.91±0.65)℃, P<0.01], 20 Hz×0.5 J[(32.75±1.41)℃vs. (30.84±1.16)℃, P<0.01], 20 Hz×1.0 J[(41.67±1.76)℃vs. (37.51±1.25)℃, P<0.01], 20 Hz×1.5 J [(47.54 ± 3.48)℃vs. (46.12±1.04)℃, P<0.01]. At the flow rate of 35 ml/min, the thulium laser was significantly higher than that of holmium laser at 10 Hz×1.0 J[(28.01±0.57)℃ vs. (26.84±0.97)℃, P<0.01], 10 Hz×2.0 J[(31.31±1.07)℃vs.(30.41±1.39)℃, P<0.01], 10 Hz×3.0 J[(33.29±0.70)℃vs.(32.25±2.55)℃, P<0.01], 20 Hz×0.5 J[(28.36±0.99)℃vs.(26.22±0.66)℃, P<0.01], 20 Hz×1.0 J [(30.80±2.06)℃vs.(30.08±0.78)℃, P=0.012], and the steady-state temperature was not significant different between two laser at 20 Hz×1.5 J [(34.54±3.08)℃ and(33.93±1.49)℃, P=0.163]. In the low flow rate group, thulium laser at 10 Hz×1.0 J, 10 Hz×2.0 J, 20 Hz×0.5 J and 20 Hz×1.0 J does not exceed the safety threshold temperature, while in the high flow rate group, any combination of laser parameters of the two lasers does not exceed the safety threshold temperature. Conclusion:Under the same laser parameter setting and flow rate, the thermal eff of thulium laser is more obvious. When using thulium laser for lithotripsy, the flow rate in the process of lithotripsy being faster than that of holmium laser with the same laser setting should be ensured to avoid tissue damage.
5.Analysis of effect on infectious diseases outbreak detection performance by classifying provinces for moving percentile method.
Honglong ZHANG ; Qiao SUN ; Shengjie LAI ; Xiang REN ; Dinglun ZHOU ; Xianfei YE ; Lingjia ZENG ; Jianxing YU ; Liping WANG ; Hongjie YU ; Zhongjie LI ; Wei LYU ; Yajia LAN ; Weizhong YANG
Chinese Journal of Preventive Medicine 2014;48(4):265-269
OBJECTIVEProviding evidences for further modification of China Infectious Diseases Automated-alert and Response System (CIDARS) via analyzing the outbreak detection performance of Moving Percentile Method (MPM) by optimizing thresholds in different provinces.
METHODSWe collected the amount of MPM signals, response results of signals in CIDARS, cases data in nationwide Notifiable Infectious Diseases Reporting Information System, and outbreaks data in Public Health Emergency Reporting System of 16 infectious diseases in 31 provinces in Chinese mainland from January 2011 to October 2013. The threshold with the optimal sensitivity, the shortest time to detect outbreak and the least number of signals was considered as the best threshold of each disease in Chinese mainland and in each province.
RESULTSAmong all the 16 diseases, the optimal thresholds of 10 diseases, including dysentery, dengue, hepatitis A, typhoid and paratyphoid, meningococcal meningitis, Japanese encephalitis, scarlet fever, leptospirosis, hepatitis, typhus in country level were the 90(th) percentile (P90), which was the same as provincial level for those diseases.For the other 6 diseases, including other infectious diarrhea, influenza, acute hemorrhagic conjunctivitis, mumps, rubella and epidemic hemorrhagic fever, the nationwide optimal thresholds were the 80th percentile (P80), which was different from that by provinces for each disease. For these 6 diseases, the number of signals generated by MPM with the optimal threshold for each province was decreased by 23.71% (45 557), 15.59% (6 124), 14.07% (1 870), 9.44% (13 881), 8.65% (1 294) and 6.03% (313) respectively, comparing to the national optimal threshold, while the sensitivity and time to detection of CIDARS were still the same.
CONCLUSIONOptimizing the threshold by different diseases and provinces for MPM in CIDARS could reduce the number of signals while maintaining the same sensitivity and time to detection.
China ; Communicable Diseases ; Disease Notification ; Disease Outbreaks ; prevention & control ; Humans ; Population Surveillance ; methods
6.The implement performance of China Infectious Diseases Automated-alert and Response System in 2011-2013.
Zhongjie LI ; Jiaqi MA ; Shengjie LAI ; Honglong ZHANG ; Xiang REN ; Lingjia ZENG ; Jianxing YU ; Liping WANG ; Lianmei JIN ; Hongjie YU ; Jinfeng WANG ; Yajia LAN ; Weizhong YANG
Chinese Journal of Preventive Medicine 2014;48(4):252-258
OBJECTIVETo analyze the implement performance of China Infectious Diseases Automated-alert and Response System (CIDARS) of 31 provinces in mainland China, and to provide the evidences for further promoting the application and improvement of this system.
METHODSThe amount of signals, response situation and verification outcome of signals related to 32 infectious diseases of 31 provinces in mainland China in CIDARS were investigated from 2011 to 2013, the changes by year on the proportion of responded signals and timeliness of signal response were descriptively analyzed.
RESULTSA total of 960 831 signals were generated nationwide on 32 kinds of infectious diseases in the system, with 98.87% signals (949 936) being responded, and the median (the 25(th) percentile to the 75(th) percentile (P25-P75) ) of time to response was 1.0 (0.4-3.3) h. Among all the signals, 242 355 signals were generated by the fixed-value detection method, the proportion of responded signals was 96.37% (62 349/64 703), 98.75% (68 413/69 282) and 99.37% (107 690/108 370), respectively, and the median (P25-P75) of time to response was 1.3 (0.3-9.7), 0.8(0.2-4.9) and 0.7 (0.2-4.2) h, respectively. After the preliminary data verification, field investigation and laboratory test by local public health staffs, 100 232 cases (41.36%) were finally confirmed.In addition, 718 476 signals were generated by the temporal aberration detection methods, and the average amount of signal per county per week throughout the country were 1.53, and 8 155 signals (1.14%) were verified as suspected outbreaks. During these 3 years, the proportion of signal response was 98.89% (231 149/233 746), 98.90% (254 182/257 015) and 99.31% (226 153/227 715), respectively, and the median (P25-P75) of time to response was 1.1 (0.5-3.3), 1.0 (0.5-2.9) and 1.0 (0.5-2.6) h, respectively.
CONCLUSIONFrom 2011 to 2013, the proportion of responded signals and response timeliness of CIDARS maintained a rather high level, and further presented an increasing trend year by year. But the proportion of signals related to suspected outbreaks should be improved.
China ; Communicable Diseases ; Disease Notification ; Disease Outbreaks ; prevention & control ; Humans ; Population Surveillance ; methods
7.The indications, efficacy and safety of endoscopic treatment of upper urinary tract urothelial carcinoma
Boxing SU ; Bo XIAO ; Weiguo HU ; Yuzhe TANG ; Meng FU ; Yubao LIU ; Xue ZENG ; Jianxing LI
Chinese Journal of Urology 2021;42(12):901-905
Objective:To summarize the preliminary clinical experience of endoscopic treatment of upper urinary tract urothelial carcinoma, and to analyze its indications and efficacy.Methods:The clinical data of 14 patients underwent endoscopic treatment for upper urinary tract urothelial carcinoma in our hospital from December 2014 to December 2019 were retrospectively analyzed. Among them, there were 5 males and 9 females, with a median age of 75.5(44-84) years. There were 11 patients with hematuria, 2 patients with flank pain and one asymptomatic patient. Five patients had a history of bladder cancer and one had a history of contralateral UTUC. There were 4 patients with solitary kidney, 3 patients with renal insufficiency, 1 patient with bilateral renal pelvis carcinoma, 4 patients prohibitory to nephroureterectomy because of poor general condition (American Society of Anesthesiologists score ≥3), and 2 patients were pathologically diagnosed as low-grade non-invasive urothelial carcinoma and requested renal preservation therapy. A total of 15 renal units included. The main tumor sites were renal pelvis in 6 renal units, upper calyx in 4 renal units, middle calyx in 3 renal units, and lower calyx in 2 renal units. The median tumor diameter was 2.0 (0.8-4.0) cm. All patients were diagnosed with urothelial carcinoma by preoperative computed tomography (CT/CTU), magnetic resonance imaging (MRI), and cytological or pathological biopsy. In 13 patients, ultrasond-guided percutaneous renal access and tract dilation were performed to establish a F24 standard tract. The tumor tissues were vaporized by 1470 semiconductor laser (60-80 W) or thulium laser (15-20 W) under nephroscopy, and electrocoagulation was used to coagulate the bleeding when necessary. Two patients were treated with felxible ureteroscope, under which tumor ablation was performed with 200 μm holmium laser fiber, and neodymium laser was used for hemostasis. The range of tumor vaporization ablation included 0.5-1.0 cm normal renal pelvis mucosa around the tumor, deep to the fatty layer of renal sinus. Biopsy was taken again at the base of the wound after vaporization ablation when necessary.Results:In this study, six sites were pathological high grade, 9 sites were pathological low grade tumors. Eight were in pathological T a stage, 5 in T 1 stage, and 2 in T 2 stage. The median blood loss was 20.0 (2-50) ml. There were 5 postoperative complications, including one patient with fever (body temperature >38.5℃) and 4 patients with hemorrhage requiring blood transfusion (postoperative hemoglobin <70 g/L) with 2-4 U suspended red blood cells.No patient underwent embolization. The median follow-up time were 31(11-70)months. Ten patients experienced recurrence, and the median time to recurrence was 11.3 (4-41) months. Four of them received conservative treatment after recurrence, including immunotherapy and radiotherapy in 1 patient, systemic chemotherapy in 1 patient, and watchful waiting in 2 patients. Three of them received repeated endoscopic treatment after recurrence, including 2 patients with percutaneous nephroscopic laser ablation and 1 patient with transurethral resection of bladder tumor, all of them survived during the follow-up period. Three patients underwent full-length nephroureterectomy after recurrence, 2 died and 1 survived during the follow-up period. Six patients eventually died, and the median time of death after surgery was 21(9-33) months. Five of them died from tumor-specific death and one died from gastric perforation. The median tumor-free survival interval were11 (4-41) months during the follow-up period. The 2-year tumor-specific survival rate was 78.6%, 50% for high-grade patients and 100% for low-grade patients. Conclusions:In patients who were in early stage (≤T 2) and intolerant to the nephroureterectomy, or with solitary kidney, renal insufficiency, or bilateral tumors, endoscopic treatment could be used as an alternative treatment approach for upper urinary tract epithelial carcinoma, especially for low-grade non-invasive patients.
8.Prognostic Analysis of Lobectomy versus Sublobar Resection in Patients Aged ≥60 Years with Stage Ia Small Cell Lung Cancer.
Haikang ZENG ; Yang LIU ; Xiaojun XIA ; Jin LI ; Jianxing HE
Chinese Journal of Lung Cancer 2018;21(1):8-15
BACKGROUND:
Currently, the prognosis of lobectomy and sub-lobectomy for the treatment of stage Ia small cell lung cancer (SCLC) is rarely reported. We retrospectively studied T1N0M0 (≤3 cm) SCLC patients aged ≥60 years, aiming to comparatively analyze the prognosis of lobectomy and sub-lobectomy in treating patients with Ia SCLC.
METHODS:
Patients with stage Ia SCLC diagnosed by pathologic between 1992 and 2010 were selected from the "Surveillance, Epidemiology and End Results database"(SEER). Outcome data were compared using Kaplan-Meier (Log-rank test) and Cox model multivariate analysis.
RESULTS:
We identified 515 patients. Median overall survival (OS) of the lobectomy (n=110), sublobar resection (n=57) and non-surgical (n=348) cohort were 45, 23 and 16 months, respectively. The corresponding 5-year OS of the three groups were 44%, 30%, and 14%, respectively. No significant difference in the prognosis of patients with or without lymph node examination/ dissection (P=0.107) and the 5-year OS of patients underwent lobectomy with chemoradiation was 50%. Cox multivariable analysis showed that operation treatment, including lobectomy and sublobectomy, was one of the independent factors associated with the prognosis of early SCLC patients, and patients undergo lobectomy shows a better OS compared with sublobar resection (Lob vs Sub, HR=0.645; 95%CI: 0.433-0.961, P=0.031).
CONCLUSIONS
For age ≥60 years T1N0M0 (≤3 cm) SCLC patients, we recommend anatomical lobectomy combined with adjuvant chemoradiation.
Aged
;
Aged, 80 and over
;
Female
;
Humans
;
Lung Neoplasms
;
diagnosis
;
surgery
;
Male
;
Middle Aged
;
Pneumonectomy
;
Prognosis
;
Retrospective Studies
;
Small Cell Lung Carcinoma
;
diagnosis
;
surgery
9.An in vitro study of temperature variation of super-pulsed thulium fiber laser in ureter
Tianfu DING ; Bo XIAO ; Zhongyue HUANG ; Xue ZENG ; Lei LIANG ; Chaoyue JI ; Jianxing LI
Journal of Modern Urology 2023;28(11):993-997
【Objective】 The thermal effects of super-pulsed thulium fiber laser (TFL) at different powers,lithotripsy modes and irrigation rates were studied using a 3D kidney model to simulate ureteral lithotripsy in vivo. 【Methods】 A thermal effect model was established in vitro. Under the same conditions of laboratory temperature and equipment,the temperature around the optical fiber was measured and compared when different optical fiber diameters,powers,lithotripsy modes and irrigation rates were used to simulate lithotripsy by TFL. 【Results】 There was significant difference in the temperature around the optical fiber caused by two fibers with different diameters under the same conditions (P<0.05). Under the same conditions,different lithotripsic modes produced different temperatures,and the temperature of "high energy and low frequency" was lower than that of "low energy and high frequency" (P<0.05). When the power was 10 W and the minimum irrigation rate was 10 mL/min,the plateau temperature did not reach the safety threshold (43 ℃). When the power was 20 W and the minimum irrigation rate was 10 mL/min,the platform temperature exceeded the safety threshold. When the irrigation rate was 20 mL/min,the platform temperature did not reach the safety threshold. 【Conclusion】 In the study of ureteral lithotripsy in vitro,the power,mode,irrigation rate and optical fiber diameter are factors affecting the thermal effects of TFL. No matter what kind of lithotripsy mode and fiber diameter,the temperature around the fiber is safe when the lithotripsy power is ≤10 W and the irrigation rate is ≥10 mL/min;when the lithotripsy power is ≤20 W and the irrigation rate is ≥20 mL/min,the temperature around the fiber is safe.