1.Analyze the practice results of digital subtraction angiography composite operating room hundred grade purification
Minxin WANG ; Lijian LIN ; Jianrong LUO
Chongqing Medicine 2014;(9):1107-1109
Objective To discuss the practice effect about the waiting area in the hospital building of the daping hosptial ,the third military medical university to be reformed into digital subtraction angiography (DSA) composite operating room .Methods We reasonably choiced the form of purify conditioning ,medical C arm ,smallpox air supply ,and the efficient screening device layout at the end of smallpox air supply .Results The main parameters of the measured results met the national standards of indexes .The fan frequency was 48 Hz running at hundred grade ,and its operation energy consumption was about 25 kw/h ;the fan frequency was 35 Hz running at ten thousand grade ,and its operation energy consumption was about 12 kw/h;the conversion time was very short between hundred grade and ten thousand grade running ,about 10 minutes .Conclusion On the condition that the building environ-ment is not fit to install hanging medical C arm ,we can thorough choose floor type C arm ,adopt “leakage resistance type clean air supply smallpox” ,reasonably modify the form of purify air conditioning to design or modify a hundred grade operating room meet-ing requirement .
2.Diagnosis of early gastric cancer with mucosa biopsy after compound Staining under gastroscopy
Xianke LUO ; Dadong WANG ; Jianrong TAN
Chinese Journal of Primary Medicine and Pharmacy 2009;16(3):389-390
Objective To investigate the diagnosis rate of early gastric calleer(EGC)with mucosa biopsy after compound staining under gastroseopy.Methods Two hundreds and six pafients who suspected tO be EGC by gastroscopy were randomly divided into two groups,the mucosa in control group(n=103)was biopsy directly under gastrescopy,and the experimental group(n=103)was biopsy after compound staining.Compared the diagnosis rate of ECG between these two groups.Results Twelve cases were confirmed to be EGC by surgery plus pathology among all the patients.Two cases were from control group,the other ten cases were from experimental group.Type Ⅱ c+Ⅲ accounted for 58.3%of twelve EGG.Eleven cases(91.7%)were positive with helicobacter pylori(Hp).Conclusion Compound staining may improve diagnosis rate of ECG.There is significant deference between directed and mueosa biopsy after compound staining under gastrescopy(P=0.033).TypeⅡc+Ⅲwere main type in endoscope of EGC.Hp infection is closely related to early gastric cancer.
3.Quality control of Scutellaria baicalensis extract with fingerprint characteristic
Hongmei YANG ; Bo GHEN ; Qi LUO ; Jianrong MIAO
Chinese Traditional and Herbal Drugs 1994;0(06):-
Objective To determine standard of Scutellaria baicalensis extract with fingerprint characteristic. Methods HPLC technique had been used to determine the content of eight flavones in S. baicalensis extract by HPLC. Results S. baicalensis extract had relative stability of fingerprint characteristic. The characterization method of fingerprint and analysis mothod were precise and rapid. Conclusion The standard of S. baicalensis extract with fingerprint characteristic has been obtained. It can be used to control the quality of S. baicalensis extract and it can support the component of Chinese materia medica.
4.Diffusing effect of DTT and 2-ME during SDS-PAGE electrophoresis
Ping YANG ; Minhui LI ; Shan CHANG ; Jianrong HE ; Xingyan LUO ; Yang LIU ; Qiang ZOU
Journal of Medical Postgraduates 2003;0(09):-
Objective: Dithiothreitol(DTT) and ?-Mercaptoethanol(2-ME) are important reducing agents for SDS-PAGE.This study is to observe the diffusing effect of DTT and 2-ME during electrophoresis,and to find a way of avoiding this effect.Methods: We placed protein samples containing reducing agents and non-reduced protein samples separately in the sample wells at intervals for SDS-PAGE electrophoresis,and determined whether or not the electrophoretic lanes of the non-reduced samples were interfered by the adjacent lanes.Results: DTT and 2-ME diffused to the neighboring lane,so that the non-reduced samples were reduced partially.The spreading effect was positively correlated with the content of the reducing agent.Conclusion: DTT and 2-ME have a diffusing effect during SDS-PAGE electrophoresis.In separating the reduced and non-reduced proteins in the same gel at the same time,at least a blank lane should be set up in between them in order to avoid the diffusing effect.
5.Using non-daily cone-beam computed tomography reduce dosimetric effect of set-up errors in intensity-modulated radiotherapy for nasopharyngeal cancer
Runye WU ; Li GAO ; Minghui LI ; Jianrong DAI ; Junlin YI ; Xiaodong HUANG ; Suyan LI ; Jingwei LUO ; Jianping XIAO ; Guozhen XU
Chinese Journal of Radiation Oncology 2011;20(5):379-383
ObjectiveTo assess the impact of set-up correction on dosimetry using non-daily kilovolt cone-beam computed tomography (KVCBCT) for nasopharyngeal cancer patients treated with intensitymodulated radiotherapy (IMRT). MethodsThe mean shift values from 14 nasopharyngeal cancer patients received KVCBCT scans during the first 5 treatment fractions were calculated as prediction of systemic set-up errors and used for off-line correction at 1.5 mm threshold level. Presumed that the systemic errors can be corrected by moving couch without residual errors, the pre-correction set-up errors in the remaining fractions were the sum of actual set-up errors and predicted errors. The dosimetric effects of non-daily protocol were simulated in the planning system and analyzed with physical dose parameters in 14 IMRT plans. ResultsIn 10 patients with predicted systemic errors > 1.5 mm, target dose was reduced significantly. The mean reduction of GTV-D98 ( dose received by 98% of the volume of GTV ), CTVnx-D95 ( dose received by 95% of the volume of CTVnx ), CTV1 -D98 ( dose received by 98% of the volume CTV1 ) were 3. 8 Gy ( Z =- 2. 81,P =0. 005 ) ,4. 8 Gy ( Z =- 1.96, P =0. 050 ), 1.0 Gy ( Z =- 2. 82, P =0. 005 ), respectively. The effect on dose to CTV2 was much less. After correction, mean 3D vector positioning errors was reduced from 3. 6mm to 2. 3 mm (t =2.00,P =0. 000). After correction, the dose led to increase in GTV-D98, CTVns-D95,CTV1-D95 was 3.8 Gy (t=-2. 70,P=0.007),5.0 Gy (t =-2. 15,P=0.030),0.9 Gy (Z=-2.80,P=0. 005 ) respectively, and reduced the dose deviation greater than 3% or 5% for organs at risk.Conclusion Non-daily KVCBCT correction reduced dosimetric effect of set-up errors in IMRT for nasopharyngeal cancer patients.
6.Dose evaluation of conventional radiotherapy using facial-cervical fields in nasopharyngeal carcinoma
Yanxin ZHANG ; Jingwei LUO ; Zhong ZHANG ; Guozhen XU ; Li GAO ; Jianrong DAI ; Junlin YI ; Xiaodong HUANG ; Jianping XIAO ; Suyan LI
Chinese Journal of Radiation Oncology 2009;18(4):308-311
Objective To evaluate the dose distribution of the target volume and the cranial base in nasopharyngeal carcinoma ( NPC ) treated with facial-cervical fields, and to analyze the differences of dose distribution using different isoeenters with the CT-simulator and treatment planning system (TPS). Methods Eleven patients with nasopharyngeal carcinoma were treated by conventional radiotherapy as their primary treatment. All patients were simulated by the conventional simulator and the field borders were marked with thin lead wires on the mask. Then the patients were scanned by the CT-sim with the same immobilization. The planning CT images were transferred to the TPS and the field borders were copied on the DRR, and then GTV and the cranial base were contoured on the coronal CT slices. Two isoeenters were chosen, including one in front of the 1 st cervical vertebra to measeure the depth of the nasopharynx and the other in front of the 3rd cervical vertebra to measure the depth of the upper neck. The prescription dose of 36 Gy was given in 18 fractions. Dose distributions of GTV and the cranial base were calculated with TPS. Results The actual dose of 95% volume of GTV was 33.31 -35.54 Gy (median 34.83 Gy) and 31.43 -33.36 Gy (median 32.44 Gy) when the isoeenters were set in the nasopharynx and the superior neck, respectively. The corre-sponding actual dose of 95% volume of the cranial base was 17.76 - 34.60 Gy ( median 30.28 Gy ) and 16.52 -32.60 Gy (median 28.52 Gy), respectively. Conclusions For NPC patients treated with conven-tional radiotherapy using facial-cervical fields, the actual dose of GTV and the cranial base is lower than the prescribed dose whenever the isocenter is set in the nasopharynx or the upper neck,which is more significant in the latter. The isocenter should be set in the nasopharynx when the conventional radiotherapy is applied and a boost of 4- 8 Gy should be given when the cranial base is involved.
7.Establishment of EA-D-IgA antibody detection method and its diagnostic efficacy for nasopharyngeal carcinoma in different clinical stage
Ruixue WANG ; Lizhong ZHANG ; Jianrong RONG ; Junping ZHANG ; Minqi LUO ; Feifei QIAO
Cancer Research and Clinic 2018;30(7):477-480
Objective To establish a serological detection method for EA-D-IgA antibody,and to evaluate its diagnostic efficacy for nasopharyngeal carcinoma in different clinical stage.Methods EA-D-IgA antibody serological detection method was established by using the polypropylene microplate with eukaryotic expression product of BMRF1 whole gene fragment of EB virus.Fifteen early stage (stage Ⅰ and Ⅱ) and 48 advanced (stage Ⅲ and Ⅳ) patients with nasopharyngeal carcinoma in Shanxi Provincial Cancer Hospital and Shanxi Dayi Hospital from April 2012 to August 2017,and serum samples from 40 patients with rhinitis who were treated at Shanxi Dayi Hospital from October 2016 to October 2017 were examined respectively by using the constructed EA-D-IgA antibody detection method.The positive detection rate of EA-D-IgA antibodies in different groups was calculated.When the patients with rhinitis were used as the differential control,the diagnostic efficacy of this index for different stages of nasopharyngeal carcinoma was evaluated.Results EA-D-IgA antibody serological method was successfully established.The positive detection rate of EA-D-IgA antibody in early nasopharyngeal carcinoma,advanced nasopharyngeal carcinoma and rhinitis control was 60.0 % (10/15),68.3 % (33/48) and 5.0 % (2/40) respectively.The differences between early stage nasopharyngeal carcinoma and the rhinitis control,advanced nasopharyngeal carcinoma and the rhinitis control were statistically significant (x2 =20.625,P =0.000;x2 =37.017,P =0.000).The difference between early nasopharyngeal carcinoma and advanced nasopharyngeal carcinoma was not statistically significant (x2 =0.394,P =0.530).When compared with the patients with rhinitis,the diagnostic sensitivity,specificity,positive predictive value,negative predictive value was 60.0 % and 68.3 %,95.0 % and 95.0 %,81.8 % and 94.3 %,86.4 % and 71.7 % respectively in early nasopharyngeal carcinoma and advanced nasopharyngeal carcinoma.Conclusion The method constructed in this study effectively improves the efficacy of EA-D-IgA antibody detection in serological diagnosis of nasopharyngeal carcinoma,which can be used as an adjunct for early diagnosis of nasopharyngeal carcinoma,yet not as a reference for clinical staging.
8.Dose distribution variation of target volumes in nasopharyngeal carcinoma treated with intensity modulated radiotherapy
Ximei ZHANG ; Minghui LI ; Jianzhong CAO ; Jingwei LUO ; Guozhen XU ; Li GAO ; Junlin YI ; Xiaodong HUANG ; Jianping XIAO ; Suyan LI ; Jianrong DAI
Chinese Journal of Radiation Oncology 2010;19(3):197-200
Objective To analyze the dose distributions of changing target volumes during intensity modulated radiotherapy (IMRT) for nasopharyngeal carcinoma (NPC). Methods Twenty-one NPC patients received definitive IMRT. A total of 126 computed tomography (CT) planning images were acquired, including the first CT scan for the primary plan and a series of scans taken weekly from the start of treatment to the fifth week. The images were registered to the planning images. Target volumes (GTV_(nx), CTV_1 ,CTV_2 ,PTV, and PTV_2) and normal structures (the parotid, brain stem and spinal cord) were re-contoured on the fusion CT images. Results The D_(mean) D_(95), D_(90), D_(10), D_5 and V_(100) of GTV_(nx) were 15.44 -15.60 Gy (F=0.07,P=0.996),14.66 -14.92 Gy (F=0. 11,P=0.990),14.81 -15.06 Gy (F= 0. 12,P=0.988),15.88 -16.29 Gy (F =0.28,P=0.924),16.00 -16.38 Gy (F=0.25,P =0. 940) and 98. 1% -99. 5 % (F = 0. 08, P = 0. 995), CTV_1 with 14. 75 -14. 98 Gy (F = 0. 07,P = 0. 997), 13.39 -13.73 Gy (F=0.20,P=0.964),13.74 -13.96 Gy (F=0.08,P=0.995), 15.65 -15.90 Gy (F= 0.09,P=0.994),15.91 -16.05 Gy (F=0. 10,P=0.992), 98.2% -99.5% (F=0.02,P= 1.000), and CTV_2 with 13.34 -13.64 Gy (F=0. 18,P=0.970),12.71 -13. 18 Gy (F=0.32,P=0.898), 12.89 -13.28Gy(F=0.23,P=0. 949) ,13.79 -14.03Gy(F=0. 12,P=0. 987) ,13.92 -14. 16 Gy (F=0. 12,P=0.987), 94.4% -99.6% (F=0.25,P=0.937), respectively. Conclusions No significantly different dose distributions exists with the changes of the target volumes, even on the largest variations of external contours. The primary plan could ensure adequate doses to the changing target volumes. The replanning is unnecessary in terms of the change of target volumes during radiotherapy.
9.Effects of zhuhong ointment on mercury cumulation and renal organization modality in skin-impaired model rat.
Han LIN ; Xuhui ZHANG ; Jianxun DONG ; Jianrong LI ; Rong HE ; Bo PENG ; Qihua XU ; Leping WANG ; Ling LUO
China Journal of Chinese Materia Medica 2012;37(6):739-743
OBJECTIVETo study the effects of Zhuhong ointment on accumulation in the body of mercury and the pathological morphology changes of kidney, via the measurement of related indicators of the skin-impaired model rat.
METHODEighty-eight SD rats were randomly divided into the impairment control group, and high-, middle-, low-dose Zhuhong ointment groups. Each group was treated by corresponding methods for 4 weeks, and recovering for 4 weeks. Urinary potein (PRO), pH, Beta N-acetyl aminoglycosidase enzymes (NAG) and beta2-microglobulin (beta2-MG) contents in urine were taken as monitoring indexes, blood urea nitrogen (BUN) and serum creatinine (SCr) in blood and the levels of mercury in urine, blood and kidney were tested, and the pathological morphology changes of kidney were observed.
RESULTAfter treatment for 4 weeks, compared with impairment control group, the levels of mercury in urine, blood and kidney in every dose group increased significantly (P < 0.01). And the relation exists between toxicity and dose on Zhuhong ointment. After recovery for 4 weeks, the levels of mercury in urine and blood in every dose group restore normal, while the level of mercury in kidney in high- dose group still increased (P < 0.01). The level of NAG increased only in high-dose group. There was no significant difference in NAG contents between Zhuhong ointment groups and the impairment control group (P < 0.05).
CONCLUSIONExcess using Zhuhong ointment repeatedly may lead to accumulation of mercury and pathological morphology changes of kidney. So the levels of mercury in the body and related indicators of renal functions should be tested in clinical when long-term using Zhuhong ointment.
Acetylglucosaminidase ; drug effects ; urine ; Animals ; Blood Urea Nitrogen ; Creatinine ; blood ; Disease Models, Animal ; Drugs, Chinese Herbal ; pharmacology ; toxicity ; Female ; Hydrogen-Ion Concentration ; drug effects ; Kidney ; drug effects ; enzymology ; metabolism ; pathology ; Male ; Mercury ; blood ; metabolism ; urine ; Ointments ; Random Allocation ; Rats ; Rats, Sprague-Dawley ; Retinol-Binding Proteins ; drug effects ; urine ; Skin ; drug effects ; injuries ; Time Factors ; beta 2-Microglobulin ; urine
10.Effect of zhuhong ointment on renal antioxidant capability in skin ulcer model rats.
Leping WANG ; Jianrong LI ; Jianxun DONG ; Ling LUO ; Rong HE ; Bo PENG ; Qihua XU ; Han LIN ; Xuhui ZHANG
China Journal of Chinese Materia Medica 2012;37(6):735-738
OBJECTIVETo study the effect of repeated administration of Zhuhong ointment on renal antioxidant capability of ulcerous skin in rats, in order to further discuss the mechanism of mercury contained in Zhuhong ointment on the antioxidant capability of kidney in skin ulcer rats.
METHODEighty SD rats were randomly divided into eight groups: Zhuhong ointment A, B, C, D, E (1.219, 0.609, 0.305, 0.152, 0.76 g x kg(-1)) groups, the vaseline group, the ulcer model group and the impairment control group. The levels of NAG and RBP of toxicity for early kidney tubular injury and T-AOC, SOD, GSH-PX and GSH in kidney were determined after consecutive administration for 14 days.
RESULTCompared with ulcer model group, the levels of RBP in groups A, B, C and D increased, while the levels of NAG increased only in the group A. The level of T-AOC increased in groups A, B and C. The level of T-SOD increased in the group E, while it dropped down greatly in the group A. The level of GSH-PX increased in groups A, B and C. The content of GSH increased in every dose groups.
CONCLUSIONAntioxidant capacity in rats can be increased in a reasonable dose of Zhuhong ointment, but some antioxidant activity can be notably inhibited by with the increase of dose.
Acetylglucosaminidase ; drug effects ; urine ; Animals ; Antioxidants ; analysis ; metabolism ; Disease Models, Animal ; Dose-Response Relationship, Drug ; Drugs, Chinese Herbal ; administration & dosage ; pharmacology ; toxicity ; Glutathione ; drug effects ; metabolism ; Glutathione Peroxidase ; drug effects ; metabolism ; Kidney Tubules ; drug effects ; injuries ; metabolism ; Male ; Mercury ; metabolism ; Ointments ; Random Allocation ; Rats ; Rats, Sprague-Dawley ; Retinol-Binding Proteins ; drug effects ; urine ; Skin Ulcer ; metabolism ; microbiology ; Specific Pathogen-Free Organisms ; Staphylococcal Skin Infections ; metabolism ; Superoxide Dismutase ; drug effects ; metabolism ; Time Factors