1.Signal preprocessing of non-contact life parameters detection by radar technology
Xijing JING ; Jianqi WANG ; Guohua LU ; Ansheng NI ; Yang ZHANG
Chinese Medical Equipment Journal 2003;0(11):-
This paper introduces the means and characteristics of signal acquisition of the non-contact life parameters detection system as well as the design of preprocessor circuit.The results show that the preprocessor is designed reasonably,which can provide the computer with high quality signals.
2.Comparing the differences between domestic and imported EIA-HIV screening results for voluntary blood donors
Liqiang XU ; Xiuwen NI ; Jianhua LI ; Jianqi SUN ; Huina MAO
Chinese Journal of Blood Transfusion 2017;30(7):813-815
Objective To compare the differences of two kinds of EIA reagents for HIV-1/2 (Ab/Ag) screening results of voluntary blood donors,in addition to find out the feasibility of reducing 1 times of EIA detection.Methods To collect data of HIV 1/2 screening positive results and confirmatory test for voluntary blood donors from 2009 to 2014 in Jiaxing area,and to compare the relationship of screeing test results with that of the confirmatory test,and then to analyze the relevance between S/CO values of screening test and confirmatory test.Results Screening positive rates of domestic and imported reagents,which were 9.58/10 000 and 12.43/10 000,respectively;and the confirmatory coincidence rates were 11.84% and 9.12%,respectively.There was no significant difference (x2 =1.11,P>0.05).The double-reagent joint detection positive rate was 1.37/10 000,and its positive predictive value was 82.86%.Single-reagent test result compared with that of double-reagent test,which had significant differences (x2domestic =94.04,P<0.05 and x2ximported =124.86,P<0.05).When the S/CO value was more than 6,domestic and imported reagents positive predictive values were 93.55% (29/31) and 87.50% (28/32),respectively.Conclusion There is no difference between domestic and imported reagents EIA-HIV1/2.
3.Study on second filtering algorithm based on tracing the interfering spectral peaks of radar non-contact life-parameter detection system.
Guohua LU ; Guosheng YANG ; Jianqi WANG ; Ansheng NI ; Xijing JING
Journal of Biomedical Engineering 2006;23(4):695-698
To develop a filtering algorithm which could trace the spectral peaks of the interference and which was used to extract the breath signal with the same band interference in radar non-contact life-detecting system, second filtering algorithm was studied. Through first filtering,the probable interfering spectral peaks (ISP) could be detected by Yule-Walker spectrum estimating and could be located by calculating the coefficients of normalized cross-correlation function according to standard breath signal. Thus the breath signal could be extracted through a second filtering. By using the second filtering algorithm (SFA), the same band interfering spectral peaks with breath signal could be recognized and inhibited. So we conclude that the same band mono-ISP could be inhibited by using SFA and breath signals could be effectively extracted.
Adult
;
Algorithms
;
Artifacts
;
Humans
;
Male
;
Monitoring, Physiologic
;
instrumentation
;
methods
;
Radar
;
instrumentation
;
Signal Processing, Computer-Assisted
4.Study on eliminating self-dithering interference of the system for non-contact detecting life parameters based on an adaptive algorithm.
Jianqi WANG ; Guohua LU ; Haibing WANG ; Xijing JIN ; Ansheng NI ; Chongxun ZHENG
Journal of Biomedical Engineering 2004;21(5):749-752
The non-contact life parameters detecting systems can detect many important life parameters such as heartbeat and breathing at certain distance. In practice, the self-dithering interference of the system is produced by some factors; it makes the signal-to-noise ratio (SNR) of the recorded signal lower. This paper is discussed an adaptive technology based on a variable step-size LMS algorithm, which is used to eliminate the self-dithering interference of the system and hence to raise the SNR of the detecting signal. A method to obtain the reference signal by vibration sensor is brought forward and the optimum parameters settings are discussed. The results show that the reference signal is an integral part of output signal of the vibration sensor and has a relationship with the setting direction of the sensor. The conclusion is that the method is effective and feasible; also the algorithm is well convergent.
Algorithms
;
Data Interpretation, Statistical
;
Electrophysiology
;
methods
;
Equipment Design
;
Heart Rate
;
physiology
;
Models, Biological
;
Reference Values
;
Respiration
;
Signal Processing, Computer-Assisted
;
Software
5.The efficacy of thin struct bare stents for the treatment of spontaneous isolated dissection of the superior mesenteric artery
Jianqi NI ; Xinxin FAN ; Changsheng HE ; Liu XU ; Lan SHEN ; Qin JIN ; Guoliang WANG ; Zaiping JING ; Yudong SUN
Chinese Journal of Surgery 2023;61(11):1001-1004
Objective:To examine the effectiveness of thin struct bare stents for the treatment of spontaneous isolated dissection of the superior mesenteric artery (SIDSMA).Methods:The data of 32 patients admitted to First Hospital of Jiaxing (20 cases) and Jinling Hospital (12 cases) with SIDSMA from January 2016 to January 2021 were retrospectively analyzed. There were 27 males and 5 females, aging (54.8±9.4) years (range: 36 to 75 years). All patients were treated with thin struct bare stents. Controllable spring coils were used to fulfill the false lumen in 2 cases. Symptoms, vascular remodeling pattern at the SIDSMA lesion, and patency of the stents were observed during follow-up.Results:The surgical success rate was 100%. According to the length of the lesions and stents, the number of stents implanted was 1 in 17 cases, 2 in 11 cases and 3 in 4 cases. The angiography showed that blood flow in the stent was smooth. The numerical rating scale for abdominal pain decreased from 6.1±1.5 (range: 4 to 10) preoperatively to 1.0 (1.0) (range: 0 to 3) 1 hour postoperatively ( W=528, P<0.01). The compression rate of the true lumen of the superior mesenteric artery decreased from (92.3±6.7)% (range: 25% to 94%) preoperatively to 0.8 (1.2)% (range: 0 to 3.2%) 1 month postoperatively ( W=528, P<0.01). The primary patency rate of CT angiography at 1 month postoperatively was 100%. The vascular remodeling rate was (92.3±6.7)% (range: 80% to 100%). All patients were followed for (46.3±17.0) months (range: 24 to 76 months). The cumulative patency rates in 1, 2 and 5 years were all 100%. Conclusion:The use of thin struct bare stents for SIDSMA could obtained the expected safety and efficacy.
6.The efficacy of thin struct bare stents for the treatment of spontaneous isolated dissection of the superior mesenteric artery
Jianqi NI ; Xinxin FAN ; Changsheng HE ; Liu XU ; Lan SHEN ; Qin JIN ; Guoliang WANG ; Zaiping JING ; Yudong SUN
Chinese Journal of Surgery 2023;61(11):1001-1004
Objective:To examine the effectiveness of thin struct bare stents for the treatment of spontaneous isolated dissection of the superior mesenteric artery (SIDSMA).Methods:The data of 32 patients admitted to First Hospital of Jiaxing (20 cases) and Jinling Hospital (12 cases) with SIDSMA from January 2016 to January 2021 were retrospectively analyzed. There were 27 males and 5 females, aging (54.8±9.4) years (range: 36 to 75 years). All patients were treated with thin struct bare stents. Controllable spring coils were used to fulfill the false lumen in 2 cases. Symptoms, vascular remodeling pattern at the SIDSMA lesion, and patency of the stents were observed during follow-up.Results:The surgical success rate was 100%. According to the length of the lesions and stents, the number of stents implanted was 1 in 17 cases, 2 in 11 cases and 3 in 4 cases. The angiography showed that blood flow in the stent was smooth. The numerical rating scale for abdominal pain decreased from 6.1±1.5 (range: 4 to 10) preoperatively to 1.0 (1.0) (range: 0 to 3) 1 hour postoperatively ( W=528, P<0.01). The compression rate of the true lumen of the superior mesenteric artery decreased from (92.3±6.7)% (range: 25% to 94%) preoperatively to 0.8 (1.2)% (range: 0 to 3.2%) 1 month postoperatively ( W=528, P<0.01). The primary patency rate of CT angiography at 1 month postoperatively was 100%. The vascular remodeling rate was (92.3±6.7)% (range: 80% to 100%). All patients were followed for (46.3±17.0) months (range: 24 to 76 months). The cumulative patency rates in 1, 2 and 5 years were all 100%. Conclusion:The use of thin struct bare stents for SIDSMA could obtained the expected safety and efficacy.