1.The design and effects of parallel double venous pots hemodialysis tubing set
Chunyan WU ; Zhihong YE ; Jianli CHAI ; Jianbin SHI ; Mingxi LU ; Hua LI
Chinese Journal of Nursing 2017;52(4):496-499
Objective To design and investigate the clinical effects of parallel double venous pots hemodialysis tubing set in patients with heparin-free hemodialysis.Methods Totally 120 patients who received hemodialysis therapy in our hospital from May,2014 to June,2016 were randomly divided into the experimental group (n=60) and the control group(n=60) via random number table.The experimental group received self-designed parallel double venous pots dialysis tubing set,while the control group received the normal dialysis tubing set.The number of preventive replacement of dialyzer and tubing set during heparin-free dialysis,the number of discarded tubing set due to coagulation and the time frame for the first tubing set were recoded from two groups.Results There were statistically significant differences in the number of discarded tubing set due to coagulation and the time frame for the first tubing between two groups(P<0.05).Conclusion Parallel double venous pots dialysis tubing set can reduce the number of discarded tubing set due to coagulation,prolong the time frame for the first tubing.
2.Quality Evaluation of Fructus aurantii and Citrus Changshan-huyou with Their Processed Products
Jianfeng SONG ; Jingqian FENG ; Liping XU ; Weinan HU ; Chuang CHENG ; Chunxian ZHU ; Yichao FANG ; Xinli CHAI ; Siqing ZHAO ; Jianhua HU ; Jianli ZHENG
China Pharmacy 2015;(30):4258-4261
OBJECTIVE: To determine the mass scores of naringin and neohesperidin in Fructus aurantii and Citrus chang-shan-huyou with their processed products and evaluate the quality of Fructus aurantii and Citrus changshan-huyou with their pro-cessed products. METHODS:According to the requirements of Chinese Pharmacopoeia(2010 edition)and Zhejiang Province Tradi-tional Chinese Medicine Preparation Standards (2005 edition),the moisture and ash of F. aurantii and C. changshan-huyou with their processed products were detected. And the contents of naringin and neohesperidin were determined. The ZORBAX SB-C18 column was used with the mobile phase of acetonitrile-water(20∶80,V/V)at the flow rate of 1.0 ml/min. The detection wave-length was set at 283 nm,and the column temperature was 40℃.The samples size was 10μl. RESULTS:The moisture of F. au-rantii and C. changshan-huyou was decreased after processing with no obvious change for ash. The contents of naringin and neohes-peridin were decreased,significantly for F. aurantii,and all consistent with the requirements of Chinese Pharmacopoeia(2010 edi-tion)except F. aurantii. The linear range was 0.028 45-0.284 5μg(r=0.999 7)for naringin and 0.085 9-0.858 6μg(r=0.999 6)for neohesperidin;the RSDs of precision,stability and reproducibility tests were no more than 1.36% and the average recovery was re-spectively 96.45%-100.43%(RSD=1.45%,n=6) and 98.36%-102.00%(RSD=1.26%,n=6). CONCLUSIONS: There was no significant difference in the inspection and determination re-sults in F. aurantii and C. changshan-huyou. It is suggested to adjust the limitation of content determination in the Chinese Pharmacopoeia(2010 edition)and processed standards.
3.Evidence-based practice of the puncture management in hemodialysis patients with difficult new arteriovenous fistula
Jianli CHAI ; Chunyan WU ; Wenjuan WANG ; Xixi ZHANG ; Mingxi LU ; Weimin HU
Chinese Journal of Practical Nursing 2022;38(13):973-979
Objective:To explore the puncture management in hemodialysis patients with difficult new arteriovenous fistula based on the finest evidence-based best practice evidence and evaluate the clinical effects.Methods:A team was formed, according to theoretical framework basing on the evidence of continuous quality improvement model, the best evidence-based interventions were obtained by adopting evidence-based practice. Formulated review indicators, evaluated obstacles and promoting factors in the process of practice, and took corresponding action strategies. From February 2020 to June 2020, 30 patients admitted to the dialysis center of Sir Run Run Shaw Hospital of Zhejiang University were recruited in the baseline review group by convenience sampling method. From September 2020 to January 2021, 30 patients from September 2020 to January 2021 were recruited in the after-effect evaluation group. The baseline review group adopted the original difficult new arteriovenous fistula puncture management scheme, and the after-effect evaluation group adopted the difficult autologous new internal fistula puncture management scheme based on the best evidence. The success rate of one puncture of fistula, the incidence rate of hematoma during puncture and dialysis, the incidence rate of discontinuation of treatment and the compliance with examination indexes were compared in the patients before and after applying for the evidences.Results:Compared with the baseline review group, the success rate of one-time puncture of internal fistula in the aftereffect evaluation group increased from 36.7% (11/30) to 73.3% (22/30), the incidence rate of hematoma during puncture and dialysis were decreased from 33.3%(10/30) to 6.67%(2/30) and 40%(12/30) to 0, the incidence rate of discontinuation of treatment were decreased from 40%(12/30) to3.33% (1/30), the difference was statistically significant ( χ2 values were 6.67-11.88, P<0.05). The implementation rate of review indexes in the aftereffect evaluation group was higher than that in the baseline review group, and the difference was statistically significant ( P<0.05). Conclusions:Evidence-based practice can improve the success rate of difficult new arteriovenous fistula, and reduce the incidence of arteriovenous fistula hematoma, reduce treatment interruption, and better maintain the lifeline of patients.
4.Finite element analysis of absorbable screws in Bernese periacetabular osteotomy
Hui CHENG ; Xiaoying MA ; Ningtao REN ; Zhendong ZHANG ; Haigang JIA ; Yong LI ; Jianli ZHANG ; Dianzhong LUO ; Hong ZHANG ; Wei CHAI
Chinese Journal of Orthopaedics 2024;44(6):419-426
Objective:To investigate the stability and feasibility of using absorbable screws during Bernese periacetabular osteotomy.Methods:A retrospective analysis was conducted on a 36 year-old woman diagnosed with developmental dysplasia of the hip, who had undergone Bernese periacetabular osteotomy. Finite element analysis was used to simulate the stability of the acetabulum under loads of 10%, 20%, 50%, and 100% of the patient's weight. The structural stiffness of the pelvis and the maximum equivalent stress on the absorbable screws were observed under different conditions, including whether the acetabular bone block and the ilium were in contact, whether 3 or 4 screws were used, and whether a graft (including fibular cortical bone and PEEK grafts) was used.Results:The structural stiffness of the pelvis fixed with four screws increased by 67%-94% compared to that with three screws. After using a graft, the structural stiffness of the pelvis increased by 50%-83%. As the load increased, the maximum equivalent stress on the screws also increased. When the acetabular bone block and the ilium had no contact, no graft was used, and only three screws were used for fixation, the maximum equivalent stress could reach 518.9 MPa, while this value dropped to 61% when four screws were used (318.7 MPa). When the acetabular bone block and the ilium were in contact, the maximum equivalent stress was about 12% of that when there was no contact, regardless of the number of screws used. When a cortical bone graft or a PEEK graft was used, the maximum equivalent stress could drop to 21%-26% of that without a graft. When the screw strength was 130 MPa, a load of 20% of body weight was applied, and only three screws were used without a graft, the equivalent stress could exceed the strength of the screw; if four screws were used, the equivalent stress was slightly higher than the strength of the screw when a load of 50% of body weight was applied. However, when a graft was used (either cortical bone or PEEK), even when a load of 100% of body weight was applied, the equivalent stress was slightly lower than the strength of the screw.Conclusion:Absorbable screws can provide sufficient stability for Bernese periacetabular osteotomy. The contact between the acetabular bone block and the ilium, an increase in the number of screws, and the use of grafts (cortical bone and PEEK grafts) can further improve stability. Therefore, absorbable screws have broad application prospects in Bernese periacetabular osteotomy.