1.Relationship of Lp-PLA2 and Severity of Coronary Plaque and Effects of Rosuvastatin at Different Doses on the Concentration of Lp-PLA2
Wentao DU ; Xue SHI ; Yan QIAO ; Jiangyong YUAN ; Guijing LIU
China Pharmacist 2016;19(6):1126-1129
Objective:To analyze the relationship of lipoprotein associated phospholipase A 2 (Lp-PLA2) and severity of coronary atherosclerosis, and evaluate the effects of rosuvastatin at different doses on the concentration of plasma Lp -PLA2.Methods: Totally 152 cases of patients with suspected coronary heart disease were treated with coronary angiography .According to the results of angiogra-phy, the patients were divided into the coronary heart disease group ( n=117 ) and the normal control group ( without coronary heart disease,n=35).Gensini integral scale was performed and referring to the number of diseased coronary arteries , the degree of coronary atherosclerosis was evaluated .The concentration of serum Lp-PLA2 was detected and the relationship of Lp-PLA2 and the severity of coronary plaque was evaluated .Meanwhile , the patients with coronary heart disease were divided into 2 groups and orally treated with rosuvastatin respectively at the routine dose (10 mg· d-1 ) and the loading dose (20 mg· d-1 ).The changes of the plasma concentra-tion of Lp-PLA2 before the treatment, in the 2nd, 4th,8th and 12th week after the medication were measured and the effect of atorvastatin at different doses on the plasma concentration of Lp-PLA2 was summarized .Results: The plasma Lp-PLA level in the control group was (22.22 ±1.75) μmol· ml-1, while that in the coronary heart disease group was (29.03 ±3.99) μmol· ml-1(P<0.05).The differences in Lp-PLA2 levels between the groups with different Gensini scores of coronary heart disease were statistically significant ( P<0.05).The higher scores were, the higher Lp-PLA2 levels were.The results of multivariate analysis showed that the severity of cor-onary atherosclerosis was significant and positive correlated with Lp-PLA2 level (OR=1.613,P<0.05).In the 2nd, 4th, 8th and 12th week after the medication , Lp-PLA2 levels in the loading dose group were significantly lower than those in the routine dose group ( P<0.05).In the 2nd, 4th, 8th and 12th week after the medication, the degree scores of coronary artery stenosis in the loading dose group were reduced.The decreasing range was significantly greater than that in the routine dose group (P<0.05).The incidence of adverse cardiovascular events in the routine dose group (27.12%) was significantly higher than that in the loading dose group (6.90%) ( P<0.05).The incidence of adverse drug reactions in the routine dose group was 11.86%, while that in the loading dose group was 18.97%(P>0.05).Conclusion:Lp-PLA2 is correlated with the severity of coronary plaque .High dose of rosuvastatin can reduce plasma Lp-PLA2 concentration in the patients .
2.Biological characteristics and whole-genome sequencing analysis of a strain of sheep-derived Streptococcus equi
Hongcai MA ; Jiangyong ZENG ; Zhenjie YUAN ; Jia WANG ; Dongjing WANG
Chinese Journal of Veterinary Science 2024;44(6):1148-1155
In order to study the biological characteristics and whole-genome sequence of Streptococ-cus equi,a sheep-derived Streptococcus equi preserved in our laboratory was subjected to recovery,biochemical experiments,drug susceptibility tests and animal experiments,and followed by whole genome sequencing and annotation of the gene functions of the genome by using the biogenetic da-tabase.The biochemical identification results showed that this strain could ferment sugars,but the results of nitrate,catalase,V-P test,and M-R test were negative;the drug susceptibility test results showed that this strain was highly sensitive to most antibiotics and was resistant to kanaphylaxis.It was resistant to amikacin and amikacin;animal experiments showed that the lethality rate of this strain to mice was 100%,and the median lethal dose of this strain was measured to be 4.86X 106 CFU/kg.According to the pathological section results of mice,it showed that the lungs,liver,kidneys,and spleen all had varying degrees of lesions.The whole genome sequencing results showed that the total genome length of this strain is 2 272 497 bp,the G+C content was 41.1%,and it was predicted to contain 2 124 CDS regions.The RNA prediction results showed that the number of rRNA and tRNA was 15,and the number of tRNA was 57.There were four prophages and gene islands,and there were 362 pathogenicity-related genes in the VFDB database without CRISPR sequences.This study analyzed the complete genome of Streptococcus equi derived from sheep,and also provided a theoretical basis for the treatment,prevention and control of the disease.
3.Three-dimensional printed 316L stainless steel cardiovascular stent's electrolytic polishing and its mechanical properties.
Zhiang CHEN ; Jingtao MIAO ; Qilong WANG ; Suxia HUANG ; Jingjing CAO ; Hezong LI ; Liguo ZHAO ; Jiangyong YUAN
Journal of Biomedical Engineering 2023;40(3):552-558
The interventional therapy of vascular stent implantation is a popular treatment method for cardiovascular stenosis and blockage. However, traditional stent manufacturing methods such as laser cutting are complex and cannot easily manufacture complex structures such as bifurcated stents, while three-dimensional (3D) printing technology provides a new method for manufacturing stents with complex structure and personalized designs. In this paper, a cardiovascular stent was designed, and printed using selective laser melting technology and 316L stainless steel powder of 0-10 µm size. Electrolytic polishing was performed to improve the surface quality of the printed vascular stent, and the expansion behavior of the polished stent was assessed by balloon inflation. The results showed that the newly designed cardiovascular stent could be manufactured by 3D printing technology. Electrolytic polishing removed the attached powder and reduced the surface roughness Ra from 1.36 µm to 0.82 µm. The axial shortening rate of the polished bracket was 4.23% when the outside diameter was expanded from 2.42 mm to 3.63 mm under the pressure of the balloon, and the radial rebound rate was 2.48% after unloading. The radial force of polished stent was 8.32 N. The 3D printed vascular stent can remove the surface powder through electrolytic polishing to improve the surface quality, and show good dilatation performance and radial support performance, which provides a reference for the practical application of 3D printed vascular stent.
Humans
;
Stainless Steel
;
Powders
;
Cardiovascular System
;
Constriction, Pathologic