1.Incidence and Risk Factors of the Caudal Screw Loosening after Pelvic Fixation for Adult Spinal Deformity: A Systematic Review and Meta-analysis
Jian ZHAO ; Zheng NIE ; Jiangjun ZHOU ; Dongfa LIAO ; Da LIU
Asian Spine Journal 2024;18(1):137-145
The purpose of this study was to assess the factors affecting caudal screw loosening after spinopelvic fixation for adult patients with spinal deformity. This meta-analysis calculated the weighted mean difference (WMD) and odds ratio (OR) using Review Manager ver. 5.3 (RevMan; Cochrane, London, UK). The loosening group was older than the control group (WMD, 2.17; 95% confidence interval [CI], 0.48–3.87; p=0.01). The S2 alar-iliac (S2AI) could prevent the caudal screw from loosening (OR, 0.43; 95% CI, 0.20–0.94; p=0.03). However, gender distribution (p=0.36), the number of fusion segments (p=0.24), rod breakage (p=0.97), T-score (p=0.10), and proximal junctional kyphosis (p=0.75) demonstrated no difference. Preoperatively, only pelvic incidence (PI) in the loosening group was higher (WMD, 5.08; 95% CI, 2.71–7.45; p<0.01), while thoracic kyphosis (p=0.09), lumbar lordosis (LL) (p=0.69), pelvic tilt (PT) (p=0.31), pelvic incidence minus lumbar lordosis (PI–LL) (p=0.35), sagittal vertical axis (SVA) (p=0.27), and T1 pelvic angle (TPA) demonstrated no difference (p=0.10). PI–LL (WMD, 6.05; 95% CI, 0.96–11.14; p=0.02), PT (WMD, 4.12; 95% CI, 0.99–7.26; p=0.01), TPA (WMD, 4.72; 95% CI, 2.35–7.09; p<0.01), and SVA (WMD, 13.35; 95% CI, 2.83–3.87; p=0.001) were higher in the screw loosening group immediately postoperatively. However, TK (p=0.24) and LL (p=0.44) demonstrated no difference. TPA (WMD, 8.38; 95% CI, 3.30–13.47; p<0.01), PT (WMD, 6.01; 95% CI, 1.47–10.55; p=0.01), and SVA (WMD, 23.13; 95% CI, 12.06–34.21; p<0.01) were higher in the screw loosening group at the final follow-up. However, PI–LL (p=0.17) demonstrated no significant difference. Elderly individuals were more susceptible to the caudal screw loosening, and the S2AI screw might better reduce the caudal screw loosening rate than the iliac screws. The lumbar lordosis and sagittal alignment should be reconstructed properly to prevent the caudal screw from loosening. Measures to block sagittal alignment deterioration could also prevent the caudal screw from loosening.
2.A new assembly of locking compression plate for treatment of femoral shaft comminuted fracture:a biomechanical study
Qianhuan GUI ; Min ZHAO ; Chunlin XIAO ; Jiangjun ZHOU ; Zhuanyi YU ; Qiuxin CHENG ; Jingxiang CHEN ; Meiqing FU ; Jun YANG ; Bona SI
Chinese Journal of Trauma 2018;34(5):426-431
Objective To compare the biomechanical characteristics of new assembly of locking compression plate (NALCP) and locking compression plate (LCP) in internal fixation of femoral shaft comminuted fractures.Methods The preparation of a femoral shaft wedge fracture model (AO type 32-C2.1),six pairs of (12) femoral specimens were collected and divided into two groups randomly,with six in each group.The Group A was made up of the new assembly of locking compression plate fixation model (NALCP),and Group B the locking compression plate fixation model (LCP).The biomechanical properties of steel plates in two groups were tested by axial loading and torsional loading tests.The relative maximum displacement of fracture blocks in two groups on the X,Y and Z axes (the coronal axis was set as X axis,through the medial and lateral femur;the transverse axis was set as Z axis,through the femoral intercondylar fossa,perpendicular to the X axis;the sagittal axis was set as Y axis,perpendicular to the X and Z axis),the maximum strain,and the average strain of the steel plate were recorded.Strain distribution nephogram was produced,and the axial loading fatigue test results of Group A were recorded.Results Axial loading test:the relative maximum displacement of fracture in Group A on X,Y and Z axis were smaller than those in Group B (P <0.05 or 0.01);the main strain of Group A was greater than that of Group B (P <0.01);there was no significant difference in the average strain between Group A and Group B (P > 0.05).Torsional loading test:The relative maximum displacement of fracture in Group A on X and Z axis was smaller than that of Group B (P < 0.01);there was no statistically significant difference between the two groups on the Y axis (P > 0.05);the main strain of plate in Group A was greater than that in Group B (P < 0.01);there was no statistically significant difference in the average strain between Group A and Group B (P > 0.05).There was no obvious difference in strain distribution between the two groups.In Group A,the fatigue test of axial cyclic loading was performed for 1 million times,and the NALCP was intact without deformation,loosening,or rupture.Conclusion NALCP can provide strong mechanical stability for comminuted femoral fracture.The design of bridge steel plate is reasonable,which can effectively avoid stress concentration,reduce the stress shielding of steel plate,and facilitate bone healing.
3.Establishment and application of infectious disease monitoring, early warning and disposal system
Hexiang JIA ; Longfang JIANG ; Chunli WANG ; Jiani ZHANG ; Yina WEI ; Jianfeng LU ; Yiming QIU ; Jiangjun ZHAO ; Baojian MA
Chinese Journal of Preventive Medicine 2024;58(10):1620-1624
Using big data and artificial intelligence to establish a multi-point monitoring, early warning, and disposal system to achieve early warning and intervention of infectious disease outbreaks is an important means of controlling the spread of the epidemic. Taking Xiaoshan district as an example, this study analyzes the monitoring contents, warning methods, and application effectiveness of the infectious disease monitoring, early warning and disposal system. Based on Xiaoshan′s health big data resources, the system starts with syndrome, disease diagnosis and etiology. Through advanced technologies such as artificial intelligence and block chain, it realizes early identification of infectious disease outbreaks, data fusion, multi-cross collaboration, and closed-loop management. It has improved the sensitivity of clustered outbreaks monitoring and the effectiveness of epidemic disposal and provided a reference for grassroots disease prevention and control departments to establish an infectious disease monitoring and early warning system.
4.Establishment and application of infectious disease monitoring, early warning and disposal system
Hexiang JIA ; Longfang JIANG ; Chunli WANG ; Jiani ZHANG ; Yina WEI ; Jianfeng LU ; Yiming QIU ; Jiangjun ZHAO ; Baojian MA
Chinese Journal of Preventive Medicine 2024;58(10):1620-1624
Using big data and artificial intelligence to establish a multi-point monitoring, early warning, and disposal system to achieve early warning and intervention of infectious disease outbreaks is an important means of controlling the spread of the epidemic. Taking Xiaoshan district as an example, this study analyzes the monitoring contents, warning methods, and application effectiveness of the infectious disease monitoring, early warning and disposal system. Based on Xiaoshan′s health big data resources, the system starts with syndrome, disease diagnosis and etiology. Through advanced technologies such as artificial intelligence and block chain, it realizes early identification of infectious disease outbreaks, data fusion, multi-cross collaboration, and closed-loop management. It has improved the sensitivity of clustered outbreaks monitoring and the effectiveness of epidemic disposal and provided a reference for grassroots disease prevention and control departments to establish an infectious disease monitoring and early warning system.
5.A new assembly of locking compression plate of low elastic modulus for fixation of femoral comminuted fractures: a biomechanical study
Bin CHENG ; Baina SHI ; Jiangjun ZHOU ; Meiqing FU ; Jun YANG ; Zhuanyi YU ; Jingxiang CHEN ; Qiuxin CHENG ; Min ZHAO ; Chunlin XIAO
Chinese Journal of Orthopaedic Trauma 2018;20(9):798-802
Objective To compare the stress and its distribution between our self-designed new assembly of locking compression plate (NALCP) of low elastic modulus versus conventional locking compression plate (LCP) in fixation of femoral comminuted fractures.Methods Six pairs of cadaveric femur were used to create models of middle femoral comminuted fracture.The femoral fracture models were fixated respectively by NALCP of Ti2448 with low elastic modulus (E =30 Gpa) (NALCP group) and conventional LCP of Ti-6Al-4V with high elastic modulus (E =110 Gpa) (LCP group).Axial and torsion loads were applied on the models in the 2 groups to simulate those on one leg when a person slowly walks.The relative maximum displacements on the X,Y and Z axes of fracture fragments,and the maximum and average strains of the plate were recorded in the 2 groups.Nephograms of strain distribution were made for the 2 groups.The results of fatigue test under axial loads were recorded for NALCP group.Results Both the axial and torsion loading tests showed significantly larger principal and average strains in NACLP group than in LCP group (P < 0.05).However,there were no significant differences between the 2 groups in the relative maximum displacements of fracture fragments on X,Y or Z axis (P > 0.05).The plate strain nephograms for the 2 groups showed consistent strain distributions.The plates in NALCP group survived 1,000,000 fatigue tests under axial loads,without any deformation,loosening or breakage.Conclusion As our NALCP of low elastic modulus may be better in stress transmission and distribution,it can effectively reduce the effect of stress-shielding and promote bone healing.
6.Advances in mesenchymal to epithelial transition factor signaling pathway and inhibitors.
Jiangjun CAO ; Zonghui WU ; Tingting TONG ; Qingzong ZHU ; Erhu ZHAO ; Hongjuan CUI
Chinese Journal of Biotechnology 2018;34(3):334-351
As a receptor tyrosine kinase, mesenchymal to epithelial transition factor (MET) is the membrane receptor for hepatocyte growth factor (HGF), which is related with a series of biological functions, such as cell proliferation, progression, apoptosis, metastasis and morphological changes. As research continues, MET is amplified or overexpressed in a wide range of human cancers and closely related with worse prognosis. Therefore, various MET inhibitors are currently being developed as potential treatments for a variety of cancers. Based on our current study we summarize the existing knowledge on structure, biological function and its inhibitors of MET and provide a data phase for future researchers.