1.An improved software design of ultrasound bone densitometer.
Zhengtao YU ; Lian YANG ; Shijie XU ; Jiangjun DENG ; Qingqing DONG ; Aijun HE
Journal of Biomedical Engineering 2014;31(5):1061-1064
In order to meet the requirements of ultrasound bone density measurement, we proposed a software solution to improve the accuracy and speed of measurement of bone mineral density of the ultrasound bone densitometer. We used a high-speed USB interface chip FT232H, along with a high-speed AD converter chip to calculate speed of sound (SOS), broadband ultrasound attenuation (BUA ) and other bone density parameters in the PC software. This solution improved the accuracy of the measurement data, reduced the measurement time and increased the quality of the displayed image. It is well concluded that the new software can greatly improve the accuracy and transmission speed of bone density measurement data through a high-speed USB interface and a software data processing technology.
Absorptiometry, Photon
;
Bone Density
;
Software
;
Sound
;
Ultrasonics
2.A new assembly of locking compression plate for treatment of femoral shaft comminuted fracture:a biomechanical study
Qianhuan GUI ; Min ZHAO ; Chunlin XIAO ; Jiangjun ZHOU ; Zhuanyi YU ; Qiuxin CHENG ; Jingxiang CHEN ; Meiqing FU ; Jun YANG ; Bona SI
Chinese Journal of Trauma 2018;34(5):426-431
Objective To compare the biomechanical characteristics of new assembly of locking compression plate (NALCP) and locking compression plate (LCP) in internal fixation of femoral shaft comminuted fractures.Methods The preparation of a femoral shaft wedge fracture model (AO type 32-C2.1),six pairs of (12) femoral specimens were collected and divided into two groups randomly,with six in each group.The Group A was made up of the new assembly of locking compression plate fixation model (NALCP),and Group B the locking compression plate fixation model (LCP).The biomechanical properties of steel plates in two groups were tested by axial loading and torsional loading tests.The relative maximum displacement of fracture blocks in two groups on the X,Y and Z axes (the coronal axis was set as X axis,through the medial and lateral femur;the transverse axis was set as Z axis,through the femoral intercondylar fossa,perpendicular to the X axis;the sagittal axis was set as Y axis,perpendicular to the X and Z axis),the maximum strain,and the average strain of the steel plate were recorded.Strain distribution nephogram was produced,and the axial loading fatigue test results of Group A were recorded.Results Axial loading test:the relative maximum displacement of fracture in Group A on X,Y and Z axis were smaller than those in Group B (P <0.05 or 0.01);the main strain of Group A was greater than that of Group B (P <0.01);there was no significant difference in the average strain between Group A and Group B (P > 0.05).Torsional loading test:The relative maximum displacement of fracture in Group A on X and Z axis was smaller than that of Group B (P < 0.01);there was no statistically significant difference between the two groups on the Y axis (P > 0.05);the main strain of plate in Group A was greater than that in Group B (P < 0.01);there was no statistically significant difference in the average strain between Group A and Group B (P > 0.05).There was no obvious difference in strain distribution between the two groups.In Group A,the fatigue test of axial cyclic loading was performed for 1 million times,and the NALCP was intact without deformation,loosening,or rupture.Conclusion NALCP can provide strong mechanical stability for comminuted femoral fracture.The design of bridge steel plate is reasonable,which can effectively avoid stress concentration,reduce the stress shielding of steel plate,and facilitate bone healing.
3.Effect of 3D-printed nano-β-tricalcium phosphate in repairing seawater-soaked tibial defects in rabbits
Hongda LAO ; Xiaoyang NIE ; Jialong GU ; Rui YI ; Da LIU ; Zhuanyi YU ; Jiangjun ZHOU ; Hao LI ; Bo XIAO
Chinese Journal of Trauma 2023;39(6):551-557
Objective:To explore the repairing effects of 3D-printed nano-β-tricalcium phosphate (β-TCP) scaffolds loaded with vancomycin and bone morphogenetic protein-2 (BMP-2) for seawater -soaked tibial bone defects in rabbits. Methods:A total of 27 male New Zealand White rabbits were assigned to the normal group using a random number table method, with each group consisting of 9 rabbits. The rabbit tibial bone defect model was created using the osteotomy surgical method. Eight hours after operation, the wounds in the control group and seawater group were immersed in seawater for 2 hours, and those in the normal group were not immersed. After an observation period of 5-7 days, no significant redness or purulent discharge was observed in the wound appearance, then debridement was performed followed by corresponding implantations: the control group with gelatin sponges loaded with vancomycin and BMP-2, and the other two groups with 3D-printed nano-β-TCP scaffolds loaded with vancomycin and BMP-2. After filling the bone defects with the respective materials, all groups underwent layer-by-layer suturing of the wound, followed by disinfection with iodine and injection of gentamicin to prevent infection. The affected limbs were then immobilized using a plaster cast. The affected limbs were imaged using anteroposterior X-ray at 4, 8 and 16 weeks after operation, and the repair effects were evaluated using the Lane-Sandhu X-ray scoring system. At 16 weeks after operation, the bone defect tissues were collected for HE staining to observe bone tissue growth.Results:At 4 weeks after operation, the Lane-Sandhu X-ray score in the control group was significantly lower than that in the normal group [(2.8±1.1)points vs. (1.1±0.9)points] ( P<0.05), and that in the seawater group [(2.2±1.0)points] was not significantly different from those in the other two groups (all P>0.05). At 8 weeks after operation, the seawater group [(6.1±0.9)points] and the control group [(2.8±1.0)points] exhibited lower Lane-Sandhu X-ray score compared to the normal group [(8.2±1.0)points] (all P<0.05), and the seawater group showed a higher score compared to the control group ( P<0.05). At 16 weeks after operation, the control group [(3.8±1.0)points] exhibited a lower Lane-Sandhu X-ray score compared to the normal group [(10.0±1.3)points] and the seawater group [(9.3±1.2)points] (all P<0.05), while no significant difference was noted between the latter two ( P>0.05). At 16 weeks after operation, histological observations revealed varying degrees of bone tissue formation in three groups, with the normal group showing the best bone defect repair effect, followed by the seawater group. Conclusion:The 3D-printed nano-β-TCP scaffolds loaded with vancomycin and BMP-2 are effective for the treatment of seawater -soaked bone defects, which can promote bone tissue repair.
4.A new assembly of locking compression plate of low elastic modulus for fixation of femoral comminuted fractures: a biomechanical study
Bin CHENG ; Baina SHI ; Jiangjun ZHOU ; Meiqing FU ; Jun YANG ; Zhuanyi YU ; Jingxiang CHEN ; Qiuxin CHENG ; Min ZHAO ; Chunlin XIAO
Chinese Journal of Orthopaedic Trauma 2018;20(9):798-802
Objective To compare the stress and its distribution between our self-designed new assembly of locking compression plate (NALCP) of low elastic modulus versus conventional locking compression plate (LCP) in fixation of femoral comminuted fractures.Methods Six pairs of cadaveric femur were used to create models of middle femoral comminuted fracture.The femoral fracture models were fixated respectively by NALCP of Ti2448 with low elastic modulus (E =30 Gpa) (NALCP group) and conventional LCP of Ti-6Al-4V with high elastic modulus (E =110 Gpa) (LCP group).Axial and torsion loads were applied on the models in the 2 groups to simulate those on one leg when a person slowly walks.The relative maximum displacements on the X,Y and Z axes of fracture fragments,and the maximum and average strains of the plate were recorded in the 2 groups.Nephograms of strain distribution were made for the 2 groups.The results of fatigue test under axial loads were recorded for NALCP group.Results Both the axial and torsion loading tests showed significantly larger principal and average strains in NACLP group than in LCP group (P < 0.05).However,there were no significant differences between the 2 groups in the relative maximum displacements of fracture fragments on X,Y or Z axis (P > 0.05).The plate strain nephograms for the 2 groups showed consistent strain distributions.The plates in NALCP group survived 1,000,000 fatigue tests under axial loads,without any deformation,loosening or breakage.Conclusion As our NALCP of low elastic modulus may be better in stress transmission and distribution,it can effectively reduce the effect of stress-shielding and promote bone healing.
5.Research on adaptive pulse signal extraction algorithm based on fingertip video image.
Jiangjun YU ; Liang ZHOU ; Zhaohui LIU ; Zhiguo LI ; Qiusha SHAN
Journal of Biomedical Engineering 2020;37(1):150-157
In order to solve the saturation distortion phenomenon of R component in fingertip video image, this paper proposes an iterative threshold segmentation algorithm, which adaptively generates the region to be detected for the R component, and extracts the human pulse signal by calculating the gray mean value of the region to be detected. The original pulse signal has baseline drift and high frequency noise. Combining with the characteristics of pulse signal, a zero phase digital filter is designed to filter out noise interference. Fingertip video images are collected on different smartphones, and the region to be detected is extracted by the algorithm proposed in this paper. Considering that the fingertip's pressure will be different during each measurement, this paper makes a comparative analysis of pulse signals extracted under different pressures. In order to verify the accuracy of the algorithm proposed in this paper in heart rate detection, a comparative experiment of heart rate detection was conducted. The results show that the algorithm proposed in this paper can accurately extract human heart rate information and has certain portability, which provides certain theoretical help for further development of physiological monitoring application on smartphone platform.