1.The progress of fibroblast growth factor receptor 3 in breast cancer
Hao WU ; Yongdong JIANG ; Da PANG
Journal of International Oncology 2015;(8):622-624
Fibroblast growth factor receptor 3(FGFR3)plays important roles in cell proliferation,diffe rentiation,and angiogenesis.Recent studies have demonstrated that FGFR3 is associated with progression of breast cancer and has effects in endocrine therapy resistance breast cancer.It has also been showed that FGFR3 is correlated with breast cancer prognosis.
2.Operation Mode and Problems of TCM Decoction for Patients
Hao JIANG ; Zhenhua WU ; Yongbing NI
China Pharmacy 2015;26(31):4333-4335
OBJECTIVE:To provide new ideas for the supervision of TCM decoction for patients. METHODS:The mode of outsourced TCM decoction for patients in Nanjing and Hangzhou area were investigated and analyzed,especially their operation mode. The safety problems of quality of the mode were analyzed from the legitimacy and standardization. RESULTS & CONCLU-SIONS:The present problems include the mismatch of professional and technical personnel of TCM decoction pieces and their qua-lification requirements;the lack of communication of pharmacists and prescribers;no restrictions for outsourced decoction of toxic TCM decoction pieces for patients;the insufficient attention for the quality and safety of packaging materials;being difficult to im-plement the main responsibility of medical institutions,etc. It is suggested to establish the filing system of centralized TCM decoc-tion institution for patients;the stationed system of pharmacy technician in medical institutions;the training and evaluation system of dispensing,decocting and other stations;the regular inspection system of health and pharmaceutical administration department;the quality evaluation system of TCM decoction for patients by following up medical staff and patients. So that it can explore a new idea for monitoring ofclearing the powers of regulatory,full participation in medical institutions,standardization and management of pharmaceutical wholesale enterprises,active supervision by patients.
3.The Postoperative Analgesic Effects of Parecoxib for Laparoscopic Urological Surgery
Hao WU ; Zhong JIANG ; Zhengliang MA
Journal of Medical Research 2006;0(03):-
Objective To evaluate the postoperative analgesic effects of parecoxib for laparoscopic urological surgery.Methods Forty patients with ASA scale ofⅠto Ⅲ underwent laparoscopic urological surgery were randomly divided into two groups: the flurbiprofen group(group Ⅰ,n=20) with IV flurbiprofen 100 mg at 2 hours after operation,and 100 mg twice a day during 3 days after operation;and the parecoxib group(group Ⅱ,n=20)with IV parecoxib 40 mg at 2 hours after operation,and 40 mg twice a day during 3 days after operation.The VAS score at 2,4,16,24 and 48 hours after operation and the adverse effects were recorded.Results The average VAS score of the two groups was 4 to 5 at 2 hours after operation,and was 0~3 at other time points.There was no significant difference among two groups in the VAS score.Conclusion Parecoxib can provid effective postoperative analgesia for patients underwent laparoscopic urological surgery as flurbiprofen.
4.Quantitative measurement of human immunodeficiency virus type 1 RNA in seminal plasma with Nuclisens HIV-1 QT
Maofeng QIU ; Hao WU ; Yan JIANG
Chinese Journal of Blood Transfusion 1988;0(03):-
Objective To evaluate NucliSens HIV-1 QT(bioMerieux,Netherlands) in quantitating human immunodeficiency virus type 1(HIV-1) RNA in whole semen or seminal plasma from HIV-1-infected people.Methods Five levels of HIV-1 RNA were spiked to whole semen,seminal plasma and blood plasma samples from healthy people,and then measured by NucliSens HIV-1 QT.The same method was used to measure HIV-1 RNA in seminal plasma and blood plasma samples from 15 HIV-1 infected people.Results Nucleic acid amplification inhibitors were found in whole semen but not in seminal plasma when using NucliSens HIV-1 QT.No significant difference was found between normal seminal plasma and blood plasma samples spiked with HIV-1 RNA,and no false positive result was found in 10 normal seminal plasma samples.For 15 cases of HIV-1 infection,HIV-1 was detected in 80%(12/15) of the plasma samples and 40%(6/15) of the seminal plasma samples,with viral loads of
5.The clinical applicationof amended concave position in gynecological laparoscopy surgery
Hao WU ; Wei ZHANG ; Zhong JIANG
China Medical Equipment 2016;13(3):91-93,94
Objective:To evaluate the clinical effects of amended concave position in gynecological laparoscopy surgery.Methods: Eighty ASAⅠ~Ⅱ patients with gynecological laparoscopy surgery were randomly divided into two groups, the patients in group A were adopted Trendelenburg position; the patients in group B were adopted amended concave position. The Ppeak and PETCO2 in the two groups were recorded during surgery, the time of extubation and the adverse effects as nausea, vomiting, shivering was recorded after surgery.Results: The Ppeak and PETCO2 of group A were higher than that of group B(t=2.526,t=2.838, t=2.881;P<0.05). The time of extubation of group A were higher than that of group B after surgery(t=2.515,t=2.436;P<0.05).Conclusion: Adopting amended concave position can reduce Ppeak and PETCO2 in gynecological laparoscopic surgery, and it is helpful for postoperative recovery of the patients with gynecological laparoscopy surgery.
6.Application of ATP bioluminescence assay in surveillance of terminal disinfection of effects
Ting JIANG ; Ying JIANG ; Lu GAN ; Hao WU ; Bo ZHANG
International Journal of Laboratory Medicine 2015;(14):1961-1962
Objective To summarize the application of ATP bioluminescence assay in surveillance of terminal disinfection of effects ,so as to provide the basis for intervention of disinfected effects .Methods ATP bioluminescence assay were employed to randomly test the surfaces of operating objects in therapeutic rooms and beside tables in wards ,total 144 object surfaces ,of each clinical departments in the whole hospital .The values of ATP bioluminescence assay were read on‐site ,0-250 RLU was recognized as qualification ,while disqualification when >250 RLU .The disqualified object surfaces were performed on‐site intervention that all of them were re‐disinfected ,the results were compared .Results Both the surfaces of operating objects and beside tables were dis‐qualified before disinfection ,and the values of ATP bioluminescence assay were 780 ± 10 .34 RL and 853 ± 13 .29 RLU respectively . The pass rates of ATP bioluminescence assay was 61 .97% of operating surfaces and 79 .45% of beside table surfaces the first dis‐infection .The disqualified sites were retested following on‐site intervention .The values of ATP bioluminescence assay were 431 .02 ± 0 .53 before intervention and 1 .43 ± 0 .59 after intervention ,and the difference was statistically significant .Conclusion ATP bi‐oluminescence assay can get more immediately ,simple and timesaving in evaluating the effect of disinfection and estimate the effi‐ciency of disinfection timely ,which can also provide the scientific basis on on‐site intervention so as to improve the execution power of hospital infection management .
7.Dosimetric comparison of volumetric modulated Arc therapy with conventional intensity-modulated radiotherapy for preoperative radiotherapy of rectal cancer
Fan JIANG ; Hao WU ; Jian GONG ; Shukui HAN
Chinese Journal of Radiological Medicine and Protection 2011;31(3):322-325
Objective To compare the dosimetric difference between RapidArc and fixed gantry angle dynamic intensity modulated radiotherapy (dIMRT) in developing the pre-operative radiotherapy for rectal cancer patients.Methods Two techniques,RapidArc and dIMRT,were used respectively to develop the synchronous intensity modulated plans for 10 stage Ⅱ and Ⅲ rectal cancer patients at the dose of gross tumor volume (GTV) of 50.6 Gy divided into 22 fractions and planning target volume (PTV) of 41.8 Gy divided into 22 fractions.Both plans satisfied the condition of 95% of PTV covered by 41.8 Gy.The dose-volume histogram data,isodose distribution,monitor units,and treatment time were compared.Results The two kinds of dose volume histogram (DVH) developed by these two techniques were almost the same.The conformal indexes of GTV and PTV by RapidArc were better than those by dIMRT (t =7.643,8.226 ,P < 0.05),while the homogeneity of target volume by dIMRT was better (t =-10.065,-4.235 ,P <0.05).The dose of rectum and small bowel planned by RapidArc was significantly lower than that by dIMRT (t =2.781 ,P <0.05).There were no significant differences in the mean doses of bladder and femoral head between these two techniques.The mean monitor units of RapidArc was 475.5,fewer by 48.5% in comparison with that by the dIMRT (924.6).The treatment mean time by RapidArc was 1.2min,shorter by 79.5% in comparison with that by dIMRT (5.58 min).Conclusions There is no significant dosimetric difference between the two plans of RapidArc and dIMRT.Compared with dIMRT,RapidArc achieves equal target coverage and organs at risk(OAR) sparing while using fewer monitor units and less time during radiotherapy for patient with rectal cancer.
8.Dosimetric comparison of RapidArc with fixed gantry dynamic IMRT for loco-regionally advanced nasopharyngeal carcinoma
Hao WU ; Shukui HAN ; Yan SUN ; Fan JIANG
Chinese Journal of Radiation Oncology 2010;19(5):410-413
Objective To compare the dosimetric difference of RapidArc and fixed gantry angle dynamic IMRT (dIMRT) for loco-regionally advanced nasopharyngeal carcinoma.Methods Ten previously treated patients with loco-regionally advanced nasopharyngeal carcinoma were replanned with RapidArc and dIMRT, respectively.The prescription dose was GTV 70 Gy/33 f and PTV 60 Gy/33 f.All plans met the requirement:95% of PTV was covered by 60 Gy.Dose-volume histogram data, isodose distribution, monitor units,and treatment time were compared.Results Dose distribution has no significant difference between the two techniques.RapidArc reduced the dose of the brainstem, mandible, and other normal tissues compared with dIMRT.Mean monitor units were 589.5 and 1381.0 for RapidArc and dIMRT (reduced by 57% relatively).Mean treatment time was 2.33 min and 7.82 min for RapidArc and dIMRT (reduced by 70% relatively).Conclusions Compared with dIMRT, RapidArc achieves equal target coverage and OAR sparing while using fewer monitor units and less time during radiotherapy for patient with loco-regionally advanced nasopharyngeal carcinoma.
9.Application of the system safety theory in medical safety management
Junsheng JI ; Yong ZHANG ; Hao WU ; Jiang LIU
Chinese Journal of Hospital Administration 2009;25(5):328-331
A description of the concept,origin and development,and key contents of the system safety theory,and an analysis of the presence and future of China's medical safety management,holding that such a theory enjoys a promising perspective in medical safety managemenL Medical safety management needs to follow such a theory as fl guideline,and its principles to set system safety objectives,and to determine the scope of the safety system_By building a comprehensive feedback mechanism,clarifying the responsibility borders and advocating a safety culture,medical safety management can be significantly upgraded.
10.The model training of knowledge-based radiotherapy treatment planning and its preliminary application
Fan JIANG ; Yibao ZHANG ; Haizhen YUE ; Qiaoqiao HU ; Hao WU
Chinese Journal of Radiation Oncology 2016;25(11):1223-1227
Objective Knowledge?based radiotherapy ( KBRT ) can reduce the plan quality variability induced by different experiences between physicians and improve the quality of treatment plans. Methods The Varian Rapid Plan system was used to train a dose?volume histogram ( DVH) prediction model. The obtained model was preliminarily applied to semi?automatic design of the preoperative treatment plans for rectal cancer. Eighty high?quality volumetric modulated arc therapy plans were imported into the model training set of the Rapid Plan system. The structures of the plans were matched to the corresponding labels and codes as listed in the library. The training started after the verification of prescription. The residual plots,regression curves,geometric plots for organ at risk ( OAR) ,in?field DVH plots,and model training logs were examined. After removal of the mismatch, the original plans were assessed to rule out outliers and influential data points. More similar plans may be added for another round of training. Ten KBRT plans were designed using the final model and compared with the clinical plans. Results For the two major OARs,the femoral head and bladder,the average goodness of fit of the principal component were 0?999 415/1.0 and 0?999 963/1.0 for the DVH model,and 0?999 651/1.0 and 0?999 945/1.0 for geometry?based expected dose model,respectively. In all the plans, 11 had Cook ’ s distance values exceeding the tolerance and 4 had studentized residual values exceeding the tolerance. The outliers were all kept in the training set to generalize the scope of the model. The 10 KBRT plans had significantly improved homogeneity indices for PGTV and PTV than the original plans (P=0?00,0?04).The 10 KBRT plans also had significantly reduced D50% to the femoral head and bladder as well as significantly reduced mean doses to the bladder than the original plans (P=0?042,0?000,0?005). Conclusions In this study,the Rapid Plan system is used to train a KBRT model for design of preoperative radiotherapy plans for rectal cancer. The results of preliminary application meet the clinical requirements.