1.CADCAE Modeling Research of Mandibular Calibration of the Projection Images Rotation Center in Micro CT System
Chinese Medical Equipment Journal 1989;0(04):-
Objective To provide research means for study of buccal cavity vitodynamics and design of optimized dental prosthetic restoration and prosthesis,give model for virtual surgery effectiveness analysis of the varied mandible surgery program.Methods A middle-aged man with normotrophic temporomandibular system was chosen and 123 widths of two-dimensional CT scan images were obtained through scanning his mandible by spiral CT scanner.The precise shaped mandible CAD mode was established through surface fitting by CATIA of three-dimensional spot-cloud transformed from two-dimensional CT images by image processing software,and the finite element model required for mandible surgery program was established by MSC.Patran.Results The full dentition mandible CAD models and three-dimensional finite element models were established.Conclusion The normal three-dimensional finite element mandible model can really reflect the geometrical feature of mandible and has good similarity to physical mandible and it can be used as a research means for biomechanical studies.The model can be also provided pre-operative designed quantitative method for the variety of mandible surgeries.
2.The design of heat dissipation of the field low temperature box for storage and transportation.
Jiancang WEI ; Jianjun SUIN ; Jian WU
Journal of Biomedical Engineering 2013;30(1):76-79
Because of the compact structure of the field low temperature box for storage and transportation, which is due to the same small space where the compressor, the condenser, the control circuit, the battery and the power supply device are all placed in, the design for heat dissipation and ventilation is of critical importance for the stability and reliability of the box. Several design schemes of the heat dissipation design of the box were simulated using the FLOEFD hot fluid analysis software in this study. Different distributions of the temperature field in every design scheme were constructed intimately in the present study. It is well concluded that according to the result of the simulation analysis, the optimal heat dissipation design is decent for the field low temperature box for storage and transportation, and the box can operate smoothly for a long time using the results of the design.
Cryopreservation
;
instrumentation
;
Drug Storage
;
Equipment Design
;
Specimen Handling
;
instrumentation
;
Thermal Conductivity
;
Transportation
3.Design of a medical folding fridge.
Jianjun SUN ; Jiancang WEI ; Taihu WU ; Xingju MENG
Chinese Journal of Medical Instrumentation 2011;35(4):266-268
This article introduces a design of a medical folding fridge, which consists of three major components, base, folding frame and insulated cover. The base has a cooling system. The frame and cover are expanded during normal use and folded during storage or transportation. The device is compact, durable, transportable and well environmental adaptable. The system design is proved proper and the temperature inside is reliable. It is very suitable for temperature sensitive supplies stored in the medical emergency field.
Emergency Medicine
;
instrumentation
;
Equipment Design
;
Refrigeration
;
instrumentation