1.Guidance value of multi-slice computed tomography in D2 radicaltotal gastrectomy for gastric cancer
Journal of Practical Radiology 2015;(10):1628-1630,1634
Objective To evaluate the application value of multi-slice spiral CT(MSCT)in D2 radical total gastrectomy for gastric carcinoma.Methods CT and clinical data of 353 cases with D2 radical total gastrectomy for gastric carcinoma was analyzed retro-spectively.Results Operative time was 236 (1 91-35 1)mins VS.245 (189-308)mins,no significant difference was observed be-tween the CT scan group and the non-CT scan group(P >0.05).The number of lymph nodes dissected was (27 ±3)VS.(20±2), there was significant difference between the CT group and the non-CT group (P <0.05).The blood loss in the CT group and no CT group was less 168 (110-600)mL and 280 (150-720)mL respectively(P<0.01).Postoperative hospital stay was shorter (11.2±2.1)days in CT group than no CT group (14.5±2.0)days (P <0.01).Postoperative complications developed in 1 7 patients in the CT group and in 29 patients in the non-CT group.The difference didn’t show statistically significant between the two groups (P >0.05).Conclusion Multi-slice computed tomography scanning has a great value in D2 radical total gastrectomy for gastric carcinoma.
2.Colorectal carcinoma:preoperative staging with water enema spiral CT
Sheng GUAN ; Jianbo GAO ; Yintai LI
Chinese Journal of Radiology 2001;0(04):-
Objective To determine the value and limitation of water enema spiral CT (WESCT) in staging of colorectal carcinoma.Methods Forty-eight patients with histologically proven rectum or colon carcinoma were included in this study. All of them were examined by SCT ,and the preoperative staging of TNM and Duke were used based on the findings of SCT.The results of WESCT were compared with those of surgical and pathological examination in all cases. Results All lesions in the 47 cases were demonstrated clearly by WESCT and the sensitivity was 97.9% ; 39 cases of 48 patients were correctly staged with TNM and 42 cases with Duke , the accuracy was 81.3% and 87.5% respectively, which were higher than the overall 50 % accuracy reported by references ;⑶The accuracy of WESCT was 89.6% (43/48) in T stage and 81.3% (39/48) in N stage. Three casas in M stage were all diagnosed correctly;Conclusion WESCT scan is a better method of depicting the colorectal carcinoma. It allows for accurate depiction and staging of colorectal carcinoma, especially detecting the invasion of adjacent tissues and distant metastasis. It is the best imaging method for staging the colorectal carcinoma . However the value of WESCT for early T staging in colorectal carcinoma and minute metastasis of lymph nodes or liver is limited.
3.Induced pneumoperitoneum in spiral CT evaluation of gastric cancer
Hua GUO ; Jianbo GAO ; Yintai LI
Chinese Journal of Radiology 1994;0(06):-
Objective To evaluate the diagnostic value and clinical significance of preoperative staging in gastric cancer with induced pneumoperitoneum in spiral CT (SCTPP). Methods Both routine SCT and SCTPP were performed in 52 lean patients suffered from gastric cancers, and comparison was made between SCT findings and surgical and histopathologic findings. Results The accuracy of routine SCT and SCTPP in determining the T-staging was 72% and 96%, respectively (?2=8.0, P0.05). The sensitivity in determining M-staging was 61% and 100%, respectively (?2=0.04, P
4.The Implication of Ionic Contrast Media Made in China in Contrast-Enhanced CT
Jianbo GAO ; Hua GUO ; Xuehua YANG
Chinese Journal of Medical Imaging Technology 2001;17(3):283-285
Purpose To evaluate the clinical safety of ionic contrast media made in china and compare with nonionic contrast media being imported. Methods Among contrast-enhanced CT 1096 cases, 76% meglumine diatrizoate were administed in 864 cases and ultravist in 232 cases , comparative studies on adverse drug reactions(ADRs) and image quality were performed. Results In 76% meglumine diatrizoate group , the prevalence of overall and mild -middle ADRs was higher than in the ultravist group , the prevalence of severe and potentially life-threatening ADRs was approximate in the ultravist group , the image quality was well than in the ultravist group.Preventive inoculation alleviated ADRs at all levels. Conclusion Ionic contrast media made in china was safe and effective in patients without hyperthyroidism after preventive inoculation.
5.CT features of renal carcinoma associated with xp11 .2 translocations/TFE3 genes fusions
Bing SHAO ; Yonggao ZHANG ; Jianbo GAO
Journal of Practical Radiology 2017;33(3):415-417,421
Objective To analyze the CT features of renal carcinoma associated with Xp11.2 translocations/TFE3 gene fusions (Xp11.2 RCC),and to improve the diagnostic accuracy.Methods Clinical data,CT imaging and pathological features of 12 cases with pathology proved Xp11.2 RCC were analyzed retrospectively.Results All the 12 cases were solid masses.11 cases were oval or quasi-circular,1 case was irregular.Tumors were iso-density or hyperdensity on CT plain scan images.The density was heterogene-ous,combined with necrosis in 11 cases and spotty or patchy calcification in 7 cases.After injection of contrast,moderate or obvious enhancement of tumors was found,1 case had retroperitoneal lymph node metastasis,1 case was found with mass formation in the re-nal hilus,1 case had adrenal metastasis.Another one was found with psoas major muscle and lumbar 5 invaded.Conclusion The Xp11 .2 RCC has certain CT characteristics.This disease should be considered when a renal tumor is iso-density or hyperdensity on the CT plain scan images and has moderate or obvious enhancement,combined with necrosis or calcification.
6.Relationship of CT features and pathological grades of malignancy in gastric stromal tumors
Ge GAO ; Pan LIANG ; Jianbo GAO ; Yan CHEN
Journal of Practical Radiology 2014;(10):1665-1669
Objective To study the relationship between the CT features and pathological grade of malignancy of the gastric stro-mal tumors (GST).Methods A retrospective review was performed based on the database of 80 consecutive patients with GST.Age and gender of the patients were recorded,and the CT findings of GST including growth pattern,morphology,tumor site,boundary, mucosa,serosa,ulcer,volume and maximum diameter of the tumor were also measured.The patients were divided into three groups:very low and low risk group,intermediate risk one and high risk one according to the pathology.All parameters were ana-lyzed by one-way ANOVA or Fisher’s exact test.Results The patients in 3 groups (from low risk to high one)were 30,30 and 20 respectively.There were no significant differences in age,gender,location and mucosa among 3 groups(P>0.05).However,the growth pattern,morphology,boundary,serosa,ulcer,volume and maximum diameter of the tumor were significantly different (P<0.05).Conclusion The CT features including growth pattern,morphology,boundary,serosa,ulcer,volume and maximum diameter of the tumor can be used to evaluate the grades of malignancy in GST.
7.Experimental study on CT lymphography in evaluating axillary sentinel lymph nodes of rabbit's breast cancer using 3D and curved planar reformation
Pange WANG ; Hongna TAN ; Bo WANG ; Huijuan XIAO ; Jianbo GAO
Journal of Practical Radiology 2017;33(4):615-618
Objective To study the value of CT lymphography (CT-LG) in evaluating axillary sentinel lymph nodes (SLN) of rabbit with breast cancer using 3D and curved planar reformation (CPR).Methods CT-LG examinations were completed on the VX2 rabbit models bearing breast cancer established by tumor tissue mass suspension injection.All raw data were transferred to a postprocessing workstation, then the 3D and CPR were used to show lymphatic vessel and lymph nodes.On the CT-LG images, one or several lymph nodes displayed firstly in the lymphatic drainage pathway was defined as the SLN which was then confirmed by the biopsy.Results (1) 20 rabbits bearing tumor underwnet CT-LG examinations, and both SLNs and draining lymphatic vessels were detected using 3D and CPR techniques.70% (14/20) of experimental rabbits had fine images, and 16 SLNs and 7 non-SLNs were demonstrated on 14 rabbits on CT-LG images with good quality.(2) 8 continuous lymphatic vessels displayed well, exhibiting a homogeneous and continuous tube with uniform contrast-medium filling on CPR images.Most lymphatic vessels demonstrated well, and the 14 vessels with local interrupt or fuzzy on 3D images showed continuous tubular contrast-filling with heterogeneous high-density on the CPR images from the injection sites to axillary SLN.Among 6 rabbits with poor images, 3 rabbits showed the SLN but without lymphatic vessels on 3D images, 2 showed only initial segment of lymphatic vessel,and 1 had no lymphatic vessel and SLN.(3) A total 24 SLNs were obtained by SLNB,including 18 metastatic SLNs and 6 negative ones.On CT-LG images, there were statistical differences between the metastatic and negative SLNs in the maximum diameter and filling defect (P=0.041 and P=0.001, respectively).However, the short diameter, shape and margin of SLNs had no statistical differences between the two groups (all P>0.05).Conclusion On CT-LG examinations, 3D and CPR images may show axillary SLNs and lymphatic vessels effectively,and CPR can demonstrate more details than 3D.The maximum diameter and fillingdefect of SLN are helpful for distinguishing metastatic and negative SLNs.
8.Diagnostic value of MSCT in cystic nephroma
Yinshi ZHENG ; Yuzhou LI ; Chunrong LI ; Jianbo GAO
Journal of Practical Radiology 2016;32(12):1909-1911
Objective To discuss the diagnostic performance of MSCT in cystic nephroma(CN).Methods The MSCT findings of CN in 7 patients proved by operation and pathology were retrospectively reviewed.Results All of 7 cases were isolated cystic lesion, including 5 males and 2 females.MSCT scanning showed cystic tumor in the renal parenchyma with well-defined boundary.All cases showed regular cystic wall and septa with no attached cystic wall nodule.The cystic wall and septa appeared homogeneous enhancement on contrast-enhanced CT,while the cystic space showed inhomogeneous density and lack of enhancement.Conclusion The MSCT findings of CN may benefit the definite diagnosis.
9.Application value of monoenergetic-plus imaging in the diagnosis of early gastric cancer
Rui LI ; Jianbo GAO ; Pan LIANG ; Jingjing XING
Journal of Practical Radiology 2017;33(2):276-279
Objective To explore the value of dual-source CT monoenergetic-plus imaging in the diagnosis of early gastric cancer. Methods Imaging data of 2 6 cases with pathologically proven early gastric cancer who underwent dual-energy scanning were analyzed retrospectively.Monoenergetic-plus images with energy levels at 40 keV,50 keV,60 keV and 70 keV were reconstructed by using an advanced monoenergetic software (syngo.via.VA30A,Dual energy Mono+).Contrast-to-noise ratio (CNR)of the lesion,image noise,overall image quality score and lesion conspicuity score were com pared between different monoenergetic-plus images and conventional polychromatic images at 1 2 0 kVp.Results The CNRs (3 .2 4 ± 0 .7 6 ,2 .9 4 ± 0 .9 2 ,2 .4 7 ± 0 .7 9 ,2 .3 7 ± 0.98 and 1.22±0.40 respectively)and image noises [(32.7±1.82)HU,(25.6±2.61)HU,(20.30±2.1 7)HU,(1 7.03±2.1 5)HU and (18.15±2.12)HU respectively]among 40 keV,50 keV,60 keV,70 keV and 120 kVp groups all had statistical differences (F =24.654 and 227.05,P <0.01).The CNR in 50 keV group was higher than that in 60 keV,70 keV and 120 kVp groups,but similar to that in 40 keV group (P >0.05).The SD value in 50 keV group was lower than that in 40 keV group,but higher than that in other three groups (P <0.05).The overall image quality score (3.08±0.27,3.65±0.49,3.31±0.47,3.23±0.43 and 3.1 5±0.37,respectively) and lesion conspicuity score (4.15±0.67,3.92±0.48,3.27 ±0.45,3.08±0.27 and 3.04±0.20)among the five groups all had statistical differences (Z =25.343 and 70.426,P <0.05).The overall image quality score of 50 keV group was higher than that of the other four groups (P <0.05).Lesion conspicuity score in 50 keV group was higher than that in 60 keV,70 keV and 120 kVp groups and similar to that in 40 keV group (P =0.1 52).Conclusion The 50 keV monoenergetic-plus images can increase the CNR value of early gastric cancer while maintaining the overall image quality.
10.The Study on the Correlation between Spiral CT Features and Expression of Cyclooxygenase-2, nm23 in Esophageal Carcinoma
Lijuan DU ; Jianbo GAO ; Xiaoan ZHANG ; Kuisheng CHEN ; Yiqiang LIU
Journal of Practical Radiology 2001;0(06):-
Objective To evaluate the correlation between spiral CT ( SCT ) features and expression of cyclooxygenase-2 , nm23 in esophageal carcinoma.Methods Spiral CT scans were preformed in 44 patients with esophageal carcinoma before operation, and the results were compared with that of operation and pathology. Immunohistochemical streptavidin peroxidase conjugate method was used to analyze the expression of Cox-2 and nm23 in esophageal carcinoma. Statistical analysis was performed with SPSS 12.0 software. Results (1) The accuracy of spiral CT scan in judging adjacent- infiltration and lymph node metastasis in 44 patients was 88.6%(39 of 44) and 90.9% (40 of 44) respectively,there was significant coincidence with operation and pathology(P