1.Expression of β-tubulin Ⅲ in colon adenocarcinoma tissue and its clinical significance
Junzhong SHI ; Jianbin ZHUANG ; Chuanshan ZHANG ; Xianming LIU ; Dalu KONG
Journal of Jilin University(Medicine Edition) 2017;43(4):770-775,前插4
Objective:To detect the expression and clinical significance of β-tubulin Ⅲ in cancer tissue of the patients with colon adenocarcinoma,and to explore its clinical significance.Methods:A total of 111 colon adenocarcinoma tissue samples were obtained.According to the location of β-tubulin Ⅲ positive cells, all patients were divided into front group (n=72) and non-front group (n=39).The positive expression rate of β-tubulin Ⅲ in the patients with colon adenocarcinoma was detected with immunohistochemistry.The correlations among the expression of β-tubulin Ⅲ and gender,age,tumor differentiation, clinical stage, lymph node metastasis, recurrence and death were analyzed.Results: The expression levels of β-tubulin Ⅲ had no significant differences between the patients with different gerder,age,lymph node metastasis,clinical stages,death and recurrence.The positive expression rates of β-tubulin in cancer tissue of the patients had significant difference between front and non-front groups (χ2=8.76, P=0.01).Lowly-to-moderately differentiated tissue was more common in front group, and highly-differentiated tissue was more common in non-front group(χ2=6.88, P=0.03).There were significant differences in the expression levels of β-tubulin Ⅲ between cancer tissues with different differentiation degrees (χ2=5.74, P=0.04).In non-front group, lymph node metastasis was closely correlated with the expression of β-tubulin Ⅲ (χ2=6.02,P=0.05).The results of immunohistochemical staining showed that the β-tubulin Ⅲ positive-expressing cells were colored brown-yellow.The number of cells with positive β-tubulin Ⅲ expression was significantly increased in highly differentiated tissue compared with low-differentiated tissue.Conclusion:The expression of β-tubulin Ⅲ is closely related to tumor differentiation in colon adenocarcinoma tissue.The highly differentiated colon adenocarcinoma tissue is more common in non-front group in which the expression of β-tubulin Ⅲ is related to lymph node metastasis.
2.Effects of transcatheter arterial chemoembolization in combination with portal vein chemotherapy on survival of patients after resection of hepatocellular carcinoma
Jianbin ZHUANG ; Yijun WANG ; Zhi DU ; Fuhua NIE ; Guiming SHU ; Jun WANG ; Chengjun LU ; Qiang YUAN
Chinese Journal of Hepatobiliary Surgery 2010;16(8):579-581
Objective To study the value of transcatheter arterial chemoembolization (TACE)in combination with portal vein chemotherapy (PVC) after resection of hepatocellular carcinoma to prolong survival. Methods From January 2000 to July 2007, 168 patients with hepatocellular carcinoma (HCC) underwent tumor resection in our hospital. After operation, TACE in combination with PVC was performed in 48 patients (combined group), TACE alone in 26 (TACE group), PVC alone in 50 (PVC group) and none of the above in 44 (control group). All the patients were followed up for 17-96 months. The 1-, 3-and 5-year survival rates were compared among the 4 groups. Results Accumulative 1-, 3-and 5-year survival rates were higher in the combined and TACE groups than in PVC and control groups. Conclusion After resection of HCC, combined use of TACE and PVC is the same as TACE in prolonging patient survival. However, it is better than PVC alone and non-surgical procedure.
3.Results analysis of serum alanine transaminase measurement in 23 clinical laboratories with target value assigned by reference method
Weimin ZOU ; Junhua ZHUANG ; Xianzhang HUANG ; Zengwen LIN ; Yun LI ; Jianbin WANG ; Jiaqi LI
Chinese Journal of Laboratory Medicine 2015;(5):318-320
Objective To explore the feasibility of inter-laboratory comparison and trueness evaluation among clinical laboratories, and assess the quality of participants′measurement, by measuring the activity of alanine aminotransferase ( ALT ) in patient serum samples.Methods Method comparison study was used.Five patients serum samples, whose target values were assigned by two international candidate reference laboratory with reference method of ALT without pyridoxal phosphate, were measured by 23 routine laboratories.The bias between measurement result of each participant and the mean of reference laboratories was calculated, and then compared to allowable bias 6%.Calculate the mean value and the relative bias.Results Compared with the mean of reference laboratories, the maximum absolute value of bias among the 23 routine laboratories was 31.27%.The rate range which bias was less than the allowable bias was 26.09%-73.91 %.The bias acceptability of 8 participants were more than or equal to 80%;15 participants were less than or equal to 60%; and 3 participants were 0%.Conclusions Using patient serum samples and values assigned by reference method is an effective way to carry out inter-laboratory comparison and trueness evaluation.It can reflect the quality of measurement more truly.
4.Clinical observation of preventive use of antibiotic inguinal hernial repair without tension and its significance
Junzhong SHI ; Jianbin ZHUANG ; Huijun SUN ; Yuzhuo CHEN ; Weiliang SONG ; Xiangchao MENG
Journal of Jilin University(Medicine Edition) 2017;43(3):622-625
Objective:To explore the necessity of the preventive use of antibiotics and the effects of age and operation time on the efficacy of inguinal hernia repair without tension,and to elucidate the clinical significance of the preventive application of prophylactic antibiotics in inguinal hernia repair without tension.Methods:A total of 228 patients with inguinal hernia repair without tension were selected,amomg them 42 cases with high infection factors were treated with antibiotics (treated group),and 186 cases were not treated with antibiotics(untreated group) during the preoperative period.The prophylactic antibiotics were given 30 min before surgery,and the conventional dose was not used more than 48 h after surgery.All the cases were treated with artificial repair materials for the procedure of inguinal hernial repair without tension.The age,highest body temperature,white blood cell count,operation time,hospitalization time,and postoperative body temperature of all the 228 cases were recorded and analyzed statistically.Results:The preoperative and postoperative white blood cell counts had significant differences between the patients<60 years and the patients≥60 years in untreated group (P<0.05);there were no significant differences in the operation time,hospitalization time and body temperature between the patients<60 years and the patients≥60 years in untreated group (P>0.05).Compared with the patients with the operation time>90 min,the white blood cell count and hospitalization time of the patients with the operation time ≤90 min were increased (P<0.05).There were no significant differences of the body temperature and age between the patients with the operation time >90 min and the patients with the operation time≤90 min (P>0.05).The white blood cell count,operation time,hospitalization time and postoperative body temperature of the patients between treated group and untreated group had no significant differences (P>0.05).Conclusion:The use of antibiotics in the high-risk patients and non-use of antibiotics in the majority of elective inguinal hernia repair without tension can ensure the safe and performability of the patients.
5.The design and clinical application of a new type of disposable heparin free dialysis tube
Chunyan WU ; Yiyu ZHUANG ; Jianbin SHI ; Yingjuan YING ; Caiping ZHOU ; Jian FENG
Chinese Journal of Practical Nursing 2017;33(18):1374-1377
Objective To investigate the clinical effect of a new type of disposable heparin freedialysis tube in uremic patients without heparin dialysis. Methods A total of 110 patients withoutheparin dialysis were divided into control group and observation group by random digits table method with55 cases each. Based on the same pre dialysis and dialysis for heparin saline flushing of discontinuoussaline on the control group using the traditional dialysis pipe for hemodialysis without heparin, theobservation group used disposable non heparin dialysis pipe for hemodialysis without heparin. The numberof patients with venous catheter blockage, blood loss and completion of dialysis time in two groups wasrecorded. Results The number of patients with venous catheter blockage, blood loss and completion ofdialysis time was 6, 6, 47 cases in control group and 0, 0, 54 cases in observation group. The differences were statistically significant (χ2=4.407, 4.407, 4.356, P<0.05). Conclusions The new disposableheparin free dialysis tube can reduce the loss of blood and prolong the treatment time, and the operation issimple, safe and effective, and has good application value and application prospect.