2.Effects of vertebral height restoration of vertebroplasty for osteoporotic vertebra compression fractures.
Hai-Peng LI ; Tian-Sheng SUN ; Fang LI ; Kai GUAN ; Guang-Min ZHAO ; Jian-Lin SHAN ; Zhi-Cheng ZHANG
China Journal of Orthopaedics and Traumatology 2012;25(8):667-669
OBJECTIVETo evaluate the effect of vertebral height restoration of vertebroplasty for osteoporotic vertebra compression fractures (VCFs).
METHODSFrom October 2004 to June 2007, a total of 37 patients with 40 VCFs were treated by vertebroplasty. There were 12 males and 25 females with a mean age of (72.4 +/- 12.7) years (ranged, 48 to 87). Pain easement state was evaluated by visual analog scale (VAS) before and after operation, as well as in followed-up. Preoperative and postoperative vertebral height, kyphosis angle at fractured levels were measured on X-rays.
RESULTSAll of patients were followed-up for 12 to 47 months (averaged, 35.8 +/- 9.6). The VAS score was 8.4 +/- 1.6 before operative, 2.1 +/- 1.2 at the 2nd day after operative, there were significant difference between pre-and postoperative (P < 0.05); the average follow-up VAS was 1.6 +/- 0.9, there were significant difference as compared with the preoperative (P < 0.05). Lateral X-ray showed that the preoperative degree of vertebral height in the of anterior and middle vertebral were (72.0 +/- 10.6)% and (68.0 +/- 15.6)%, and postoperative were (76.0 +/- 8.6)% and (73.0 +/-6.1)%, respectively. There were no significant difference in vertebral height between preoperative and postoperative. The vertebral kyphosis angle was corrected from preoperative (7.8 +/- 2.7) degree to postoperative (8.1 +/- 2.3) degree.
CONCLUSIONVertebroplasty is a safe and effective method for treatment of osteoporotic VCFs, it can relieve the pain effectively. Failure to restore vertebaral height does not seem to interfere with the excellent pain management.
Aged ; Aged, 80 and over ; Female ; Fractures, Compression ; complications ; diagnostic imaging ; surgery ; Humans ; Male ; Middle Aged ; Osteoporosis ; complications ; Radiography ; Spinal Fractures ; complications ; diagnostic imaging ; surgery ; Spine ; diagnostic imaging ; pathology ; surgery ; Treatment Outcome ; Vertebroplasty ; methods
3.Emergency repair of severe complex defect in forearm by transplantation of free flap and functional reconstruction
Shu-Jian HOU ; Guo-Liang CHENG ; Guang-Rong FANG ; Zhen-Jun WANG ; Le-Tian SUN ; Xu HE ; Hong-Xun ZHANG ;
Chinese Journal of Microsurgery 2006;0(05):-
Objective To report the outcome of emergency repair of severe complex defect in forearm by transplantation of free flap and simultaneous functional reconstruction.Methods From Mar.1994 to Aug.2003,4 cases with severe complex defect in forearm was repaired by transplantation of free skin flap, free skin flap combined with fibula flap,or fibula osteocutaneous flap in emergency.Simultaneously the flexion and extension function were repaired by muscle transfer and/or tendon grafting,tenonectomy.Results All the cases were successful.Follow-up period ranged from 1 to 3 years postoperatively.The blood-supply,tex- ture and elasticity of transferred flaps were excellent with good bone healing.Opposition of thumb with four fin- gers was good.Sensory recovery of the hand was satisfactory.Conclusion Transplantation of free flap com- bined with simultaneous functional reconstruction is an ideal method in emergency repair of severe complex de- fect in forearm.
4.Evaluation of visual quality after phakic posterior chamber intraocular lens and iris-claw phakic intraocular lens Implantation for high myopia
Hong-liang, GUO ; Guang-ying, ZHENG ; Song-tian, WANG ; Jie, WANG ; Rui-na, WANG ; Jian-guo, ZHAO ; Li-jun, ZHAO
Chinese Journal of Experimental Ophthalmology 2011;29(5):423-426
Background High myopia can be corrected using laser therapy and intraocular lens(IOL)implantation.IOL implantation is more suitable than laser therapy for high myopia if the patients suffer from thinner cornea.Objective This clinical trail was to assess and compare the visual quality following phakic iris-claw intraocular lens (IOL) and implantable contact lens(ICL) implantation for high myopia.MethodsIris-claw phakic intraocular lens was implanted in 17 eyes of 10 patients with high myopia,and age-,refractive-matched 17 eyes of 9 patients were in implantable contact lens (ICL) implantation group.Uncorrected visual acuity,best correct visual acuity,contrast sensitivity under the 3,6,12 and 18 c/d spatial frequencies,wave-front aberrations,including RMS3,RMS4 and RMSh,were examined in 6 months after operation.Written informed consent was obtained from each patient before surgery.Results There were no significant difference in uncorrected visual acuity,best correct visual acuity between two groups(t=0.489,P>0.05;t=0.853,P>0.05).Non-glare CS under the 3 c/d,6 c/d,12 c/d and 18 c/d spatial frequencies were insignificantly different between two groups ( t = 0. 906, P > 0.05 ; t = 0. 103, P > 0. 05 ; t =0. 694 ,P>0. 05 ; t = 1. 583, P>0. 05), and the similar outcomes were found in glare CS ( t = 0. 323, P>0.05, t =0.041 ,P>0. 05, t = 0.024, P>0. 05; t = 0. 363, P>0.05) in postoperative 6 months. RMS3 and RMSh were significantly elevated in PIOL group compared with ICL group ( t = 11.40, P< 0. 05 ; t = 11.35, P < 0.05), but no evident difference was found in RMS4 between two groups( t = 0. 24,P>0. 05). Conclusion Both PIOL and ICL implantation for high myopia can achieve an equal visual acuity. But clinical outcomes of ICL implantation is much better than PIOL group. A long-term effect should be observed for the further evaluation.
5.Curative effect of capreomycin in adjuvant treatment of multidrug-resistant pulmonary tuberculosis and its effect on quality of life and immune function
HAN Na ; LIU Fan-ping ; LANG Wei-ming ; ZHANG Chen-yu ; TIAN Yan-qing ; WANG Qian ; JIAN Shi-ning ; ZHU Jian-guang
China Tropical Medicine 2023;23(3):246-
Abstract: Objective To investigate the efficacy of capreomycin adjuvant therapy for multidrug-resistant pulmonary tuberculosis (MDR-TB) and its effect on quality of life and immune function. Methods Eighty-eight elderly pulmonary tuberculosis patients admitted to Affiliated Hospital of Hebei University from October 2019 to October 2020 were selected and divided into two groups according to the random number table method. The control group (n=44) used 4-6Am-Mfx(Lfx)-Pto-Cfz-Z-Hhigh-dose-E/5 Mfx(Lfx)-Cfz-Z-E, the research group (n=44) used capreomycin on the basis of the control group. The 6-Minute Walk Test (6MWT) measured value/predicted value and quality of life [36-Item Short Form Health Survey Questionnaire (SF-36)] scores, safety evaluation results, chest CT cavity and lesion absorption rate and sputum culture turned negative were compared between the two groups, and the serum procalcitonin (PCT) expression levels and immune function were detected before and after treatment. Results The 6MWT measured value/predicted value of the research group and control group before the treatment were (0.48±0.11) and (0.64±0.13), which were significantly higher than corresponding (0.51±0.12) and (0.58±0.14) after treatment (t=6.23, 2.520, P<0.05), the measured/expected value of 6MWT increased in both groups after treatment. Compared with the same group before treatment, the SF-36 scores for each dimension increased in both groups after treatment (P<0.01). The expression levels of serum PCT in the research group and control group before the treatment were (0.37±0.09) ng/mL and (0.12±0.03) ng/mL versus (0.36±0.11) ng/mL and (0.21±0.06) ng/mL after treatment (t=17.480, 7.940, P<0.01). Compared with the same group before treatment, serum PCT expression levels decreased in both groups after treatment. Compared with the same group before treatment, CD3+, CD4+ and CD4+/CD8+ were elevated in both groups after treatment (P<0.05 or P<0.01); after treatment, CD3+, CD4+, and CD4+/CD8+ were significantly higher in research group compared to the control group (t=4.21, 8.02, 2.04, P<0.05). The absorption rate of chest CT cavity and lesions and negative rate of sputum culture in the research group were 88.64% (39/44) and 81.82% (36/44), which were significantly higher than corresponding 63.64% (28/44) and 61.36% (27/44) in the control group (P<0.05). Conclusions Capreomycin can improve the quality of life of MDR-TB patients, extend the 6-minute walking distance, and regulate serum PCT expression levels and immune function, to promote the absorption of chest CT cavity and lesions, and sputum culture to turn negative, and the security is acceptable.
6.Comparative study of the pulmonary function equipment and Douglas-bag in the energy consumption measurement of Chinese healthy youth.
Jian-min LIU ; Zeng-nian XU ; Yan LI ; Rui SUN ; Ying TIAN ; Min LI ; Jian-hua PIAO ; Xiao-guang YANG
Chinese Journal of Preventive Medicine 2010;44(9):795-799
OBJECTIVETo determine the validity of the pulmonary function equipment.
METHODS12 young students (including six males and six females) were enrolled as our research subjects. And the values of oxygen consumption (VO(2)), carbon dioxide production (VCO(2)) and energy expenditures (EE) of the subjects under three typical activity intensities: resting, moderate intensity (on a treadmill with grade 10% and speed 2.7 km/h) and hard intensity (on a treadmill with grade 10% and speed 5.8 km/h) were measured using the pulmonary function equipment (K4b(2)) and Douglas-bag respectively. And the Douglas-bag method was used as reference and the results were compared with the other method.
RESULTSThe measured VO(2) values by using the Douglas-bag and the pulmonary function equipment under three typical activity intensities were: at rest (0.22 ± 0.03), (0.22 ± 0.05) L/min (t = 0.120, P > 0.05); moderate intensity condition (0.95 ± 0.12), (0.96 ± 0.14) L/min (t = 0.240, P > 0.05); hard intensity condition (1.63 ± 0.28), (1.54 ± 0.35) L/min (t = 1.487, P > 0.05). For VCO(2) values: at rest (0.18 ± 0.02), (0.18 ± 0.04) L/min (t = 0.425, P > 0.05); moderate intensity (0.82 ± 0.11), (0.83 ± 0.13) L/min (t = 0.579, P > 0.05); hard intensity (1.64 ± 0.27), (1.52 ± 0.39) L/min (t = 2.330, P < 0.05). And for EE values, at rest (269.40 ± 35.70), (267.02 ± 55.39) kJ/h (t = 0.200, P > 0.05); moderate intensity (1165.76 ± 148.06), (1185.91 ± 161.89) kJ/h (t = 0.326, P > 0.05); hard intensity (2062.91 ± 341.97), (1912.27 ± 483.88) kJ/h (t = 1.718, P > 0.05) respectively. The results showed that there were no significant differences between the two methods except the VCO(2) values under high intensity condition was underestimated by the pulmonary function equipment. Bland-Altman test showed that the difference of the two methods was evenly distributed by the mean and standard error of the system was 24.7 kJ/h. Our data showed the results from the Douglas-bag and the pulmonary function equipment were consistent.
CONCLUSIONPulmonary function equipment had good validity in assessing the energy expenditure in Chinese adults.
Adolescent ; Adult ; Energy Metabolism ; physiology ; Exercise Test ; instrumentation ; Female ; Humans ; Male ; Oxygen Consumption ; physiology ; Respiratory Function Tests ; instrumentation ; Students ; Young Adult
7.Detection of focal epileptic activity using combined simultaneous electroencephalogram-functional MRI
Zhi-Qiang ZHANG ; Guang-Ming LU ; Lei TIAN ; Kang-Jian SUN ; Qi-Fu TAN ; Jian-Guo ZHU ; Cong NIE ; Shao-Wei HAO ; Li JIANG ; Yi-Jun LIU
Chinese Journal of Radiology 2000;0(11):-
Objective To observe the brain activation of interictal epiletiform discharges(IEDs) and to localize the epileptogenic foci of epilepsy.Methods The electroencephalogram(EEG)and functional MRI data of 12 focal epileptic patients were acquired using a combination of EEG and functional MRI simultaneously.The IEDs onset time detected with EEG were set as the time parameters in an event- related paradigm of functional MRI analysis.The spatial and temporal characters of IEDs activation were analyzed in detail.In order to confirm the consistency of this method,all patients were scanned repeatedly and the results were correlated with clinical evaluation.Results Of the 12 patients,valid data from EEG- fMRI were obtained from 10 patients in a total of 18 sessions..Compared with the structural foci,the epileptic foci localization results of eleven sessions were good,five sessions were fairly good,and two sessions were poor.The results obtained from six patients in two separate sessions were concordant.respectively.Moreover,thalamic activation was detected in ten sessions,cerebellar activation was detected in all sessions,and the deactivation was found in the default mode loci in nine sessions. Conclusion The method of performing EEG and fMRI simultaneously can potentially be a useful tool in epilepsy research.
8.A novel approach for identifying the critical amino acid residues on binding site of GPIbα and vWF-A1 domain through molecular dynamics simulation
Tian-tian DOU ; Jian-hua WU ; Guang-jian LIU ; Ying FANG
Journal of Medical Biomechanics 2013;28(6):E606-E614
Objective To develop a novel computer method for identifying the critical amino acid residues in the receptor-ligand interactions. Methods GPIbα/vWF-A1 crystal structure was taken from Protein Data Bank (PDB code 1SQ0). Free molecular dynamics simulations were performed to observe the formation and evolution of hydrogen bonding and salt bridge on the binding sites of GPIbα and vWF-A1 by VMD. A residue interaction index, which was scored with the survival ratios of salt bridges and/or hydrogen bonds involved in interaction of a residue to other(s), was used as a criterion of the residue’s role in interaction between the receptor and ligand. Results In the interface, 21 residues in GPIbα and 21 residues in vWF-A1 were significantly identified to participate in the interaction between GPIbα and vWF-A1; 20 of these 42 key residues were verified by previous mutagenesis experiments. Conclusions This novel approach is useful for computationally identifying the key residues involved in GPIbα-vWF interaction, and has potential in developing new strategy for the traditional mutagenesis experiments and the antithrombotic mAbs drug design.
9.Energy expenditure in reading and watching TV studied on 30 young females.
Rui SUN ; Jian-Hua PIAO ; Yuan TIAN ; Wei-Dong LI ; Jian-Min LIU ; Ying TIAN ; Min LI ; Jie DONG ; Ling-You GOU ; Xiao-Guang YANG
Chinese Journal of Preventive Medicine 2008;42(3):196-198
OBJECTIVETo measure the energy expenditure of reading and watching TV for young women.
METHODSAll 30 girls in the college were selected according to questionnaire, medical examination, blood test, liver function and thyroid gland level. Energy expenditure of reading and watching TV was measured respectively by the Cosmid K4b2 portable gas analysis system from Italy. Basic metabolic rate (BMR) and resting metabolic rate (RMR) were measured as to analyzing results conveniently.
RESULTSThe energy expenditure in reading was (226.35 +/- 56.07) kJ/h and the heart rate was (69 +/- 5) bmp. For watching TV it was (220.79 +/- 65.69) kJ/h and the heart rate was (68 +/- 5) bmp. BMR was (178.53 +/- 53.51) kJ/h and the heart rate was (62 +/- 6) bmp. RMR was (214.76 +/- 44.56) kJ/h and the heart rate was (65 +/- 6) bpm.
CONCLUSIONSThe energy expenditure in reading should be higher than that of watching TV, however, the difference was not obvious. The expenditure rates might get closer to those of RMR. It might be regarded as an expenditure of very light physical active in Chinese.
Adolescent ; Adult ; Basal Metabolism ; Female ; Humans ; Reading ; Rest ; physiology ; Television
10.Comparison of bioelectrical impedance analysis and isotope dilution method in assessment of body composition.
Jian-min LIU ; Jian-hua PIAO ; Rui SUN ; Ying TIAN ; Yuan TIAN ; Wei-dong LI ; Xiao-guang YANG
Chinese Journal of Preventive Medicine 2008;42(4):244-247
OBJECTIVETo determine the validity of bioelectrical impedance analysis (BIA) in measuring body composition and to compare with the reference stable isotope dilution method.
METHODSAccording to the data from 150 students of Bethune Military Medical College, 16 female young adults with normal BMI were selected as the participants. The experimental period was 14 days. During the experimental period, the subjects were centralized on management. At the first day of the period, double labeled water was given to the subjects orally. The urine collection time-points were 2h, 4h, 6h, 8h and the 2nd to 14th day after the administration of isotope dose. All isotope measurements were made by using an isotope ratio mass spectrometer. From the isotope curing curve, the indexes of body composition were gained. At the same time, the body compositions were also measured by using BIA method every day (3 hours after dinner). The paired t test and Pearson correlations were used to measure the significance and the degree of correlation between the measurements determined by using the two methods.
RESULTSThere were no significant differences between the measurements determined by using the two methods. TBW, FFM, BF and BF% measured with the BIA method were significantly correlated with those measured by using the isotope method (r = 0.556, 0.556, 0.817 and 0.606 respectively).
CONCLUSIONBIA might provide an accurate and reliable assessment in body composition of the healthy Chinese adults.
Adipose Tissue ; anatomy & histology ; Adult ; Anthropometry ; methods ; Body Composition ; Body Mass Index ; Body Water ; Electric Impedance ; Humans ; Male