1.Reinforced bar-ring Hybrid external fixator combined with limited internal fixation for complex fractures of tibial plateau
Gang FENG ; Zhi-Jun PAN ; Qiang ZHENG ; Hang LI ; Jian-Bing LI ; Jian WANG ;
Chinese Journal of Trauma 2003;0(08):-
Objective To introduce the experience and analyze the clinical outcome of applica- tion of reinforced bar-ring hybrid external fixator combined with limited internal fixation for complex frac- turcs of tibia plateau in patients.Methods From Aug.2002 to Feb.2005,21 patients with complex fractures of tibial plateau were treated with reinforced bar-ring hybrid external fixatar combined with lim- ited internal fixation.According to Schatzker classification,there were 13 patients with typeⅤfracture and 8 with typeⅥfracture.Voluntary and non-weight beating knee joint motion to partially weight bear- ing was taken one week after operation.Progressive loading was taken continuously until there was clinical evidence of fracture stability and then full weight bearing was done.Results The mean follow-up peri- od was 15.9 months (10-24 months).All the fractures got united and the mean union time was 4.2 months(3-8 months).All the injured knees could extend to less than 5 degrees and flex to more than 90 degrees after rehabilitation.Evaluated by Merchant score system for knee joint,81% of patients achieved excellent healing (7 cases) and good healing (10 cases).Conclusion Operation by using reinforced bar-ring hybrid external fixator combined with limited internal fixation can reduce complications and avoid stiffness of the knee joint.It is an effective method for complex fractures of tibial plateau.
2.Recent progress on osteocyte research.
Gang WANG ; Chao-feng LU ; Min LI ; Hang YING ; Pei-jian TONG
China Journal of Orthopaedics and Traumatology 2016;29(1):89-93
Content of osteocyte in bone tissue is the most abundant, the most widely distributed, and embedding the cells in the mineralized bone matrix, the life can be close to the life of the body. Osteocyte formed by the cytoplasm dendritic communication network system between osteocyte and bone surface, is of great significance to maintaining the normal physiological function of bone tissue. Bone cells as the direct receptor of bone mechanical stress, through the release of bioactive factors such as PEG2, NO, ATP and classic Wnt/beta-catenin signaling pathway mechanical stress signal can be converted to bone formation and bone resorption of biochemical signals, and the biochemical signals were transfer to the other type cells of the tissue to regulate its function activities and cause bone reconstruction function. The microcracks surrounding osteocyte can disrupt the microtubule network system,cause surrounding osteocyte autophagy. In addition, osteocyte is very important for regulation of the body mineral balance, fat metabolism, and hematopoietic function.
Animals
;
Autophagy
;
Hematopoiesis
;
Humans
;
Minerals
;
metabolism
;
Osteocytes
;
physiology
;
Signal Transduction
;
Stress, Mechanical
3.Inhibitory effect of salidroside on hypoxia-induced apoptosis of corpus cavernosum smooth muscle cells in rats.
Jian-Feng ZHAO ; Hui-Ying FU ; Fan YANG ; Xiao-Jun HUANG ; Gang CHEN ; Bo-Dong LÜ
National Journal of Andrology 2014;20(4):309-314
OBJECTIVETo investigate the effect of salidroside on hypoxia-induced apoptosis of corpus cavernosum smooth muscle cells (CCSMCs) in rats.
METHODSRat CCSMCs were cultured in vitro by the enzyme digestion method and identified by immunofluorescent staining of anti-alpha-SMA and anti-Desmin. The non-toxic dose of salidroside was determined by MTT assay. Low-oxygen mixed gas (1% O2, 5% CO2, and 94% N2) was piped into a modular incubator chamber to induce hypoxia. The CCSMCs were divided into a normal, a hypoxia, and a 32 microg/mL salidroside intervention group. The apoptosis of the CCSMCs was detected by flow cytometry and the expression of the caspase-3 protein determined by Western blot.
RESULTSThe majority of the CCSMCs were positive for alpha-SMA and Desmin at immunofluorescent staining. Salidroside at < 32 microg/ml produced no obvious toxicity to CCSMCs. Compared with the normal control group, the rates of early and late apoptosis of CCSMCs were both increased significantly in the hypoxia group ([12.77 +/-1.41]% vs [18.69 +/- 1.29]%, P < 0.01 and [14.63 +/- 2.00]% vs [21.03 +/- 1.530]% , P < 0.05). Western blot showed a markedly increased expression of cleaved caspase-3 (P < 0.01). Intervention with 32 microg/ml salidroside significantly reduced hypoxia-induced early apoptosis of CCSMCs ([13.46% +/- 1.87]%, P < 0.01) and decreased the expression of cleaved caspase-3 (P < 0.01).
CONCLUSIONSalidroside can reduce the expression of cleaved caspase-3 and inhibit hypoxia-induced apoptosis of CCSMCs in rats.
Animals ; Apoptosis ; drug effects ; physiology ; Caspase 3 ; metabolism ; Cell Hypoxia ; physiology ; Cells, Cultured ; Glucosides ; pharmacology ; Humans ; Male ; Myocytes, Smooth Muscle ; cytology ; drug effects ; enzymology ; Penis ; cytology ; drug effects ; Phenols ; pharmacology ; Rats
4.Recent Development of Wearable Microfluidics Applied in Body Fluid Testing and Drug Delivery
Yiqiang FAN ; Feng GAO ; Mei WANG ; Jian ZHUANG ; Gang TANG ; Yajun ZHANG
Chinese Journal of Analytical Chemistry 2017;45(3):455-463
wearable microfluidics have wide applications in medical, sports and military field. with the help of wearable microfluidics, through the direct physical contact between the chip and skin, the pH, glucose, lactate, sodium/potassium, calcium and heavy metal in the body fluid can be detected from sweat, tear and saliva without puncture for blood. And these information are of great importance for the monitoring of vital signs and disease diagnosis. This paper introduced the most recent development and applications of the wearable microfluidics in the body fluid testing and drug delivery. The up-to-date research development for the drug delivery using wearable microfluidics was also briefly introduced in this article. The forecast of the emerging trend for wearable microfluidics and discussion of potential technique barriers was also provided at the end of this article.
5.Study on bone mesenchymal stem cells transfected by polyethylene glycol/bone morphogenetic protein-2.
Li-Feng DING ; Gang ZHENG ; Jun YANG ; Zhen-Dong ZHOU ; Jian-Jun LI
China Journal of Orthopaedics and Traumatology 2014;27(1):48-53
OBJECTIVEPolyethylene glycol/bone morphogenetic protein-2 (PEG/BMP-2) nanoparticles were transfected into Rabbit bone mesenchymal stem cells (rBMSCs) and the expression of BMP-2 was detected.
METHODSDissociated rBMSCs were primarily cultured in vitro and BMP-2 gene was transfected into rBMSCs by PEG/BMP-2 nanoparticals and lipofectamine, respectively. The efficiency of transfection was detected by flow cytometry and the expression of BMP-2 was detected by Western Blot and real time RT-PCR.
RESULTSPEG/BMP-2 nanoparticals were successfully synthesized and transfected into rBMSCs. Compared with the lipofectamine transfection group, PEG/BMP-2 transfection group had higher efficiency and higher BMP-2 expression.
CONCLUSIONPEG/BMP-2 nanoparticals transfected rBMSCs highly expressed BMP-2,which provided novel strategies for the treatment of bone defect.
Animals ; Bone Diseases ; genetics ; therapy ; Bone Morphogenetic Protein 2 ; chemistry ; genetics ; metabolism ; Bone and Bones ; cytology ; Gene Expression Regulation ; Humans ; Mesenchymal Stromal Cells ; cytology ; metabolism ; Nanoparticles ; chemistry ; Polyethylene Glycols ; chemistry ; RNA, Messenger ; genetics ; metabolism ; Rabbits ; Transfection ; methods
6.Modification by wheat germ agglutinin delays the ocular elimination of liposome.
Wen-Jian ZHANG ; Dong-Xiao YANG ; Ling-Lin FENG ; Fei WANG ; Gang WEI ; Wei-Yue LU
Acta Pharmaceutica Sinica 2014;49(4):543-549
The purpose of this study is to explore the feasibility of wheat germ agglutinin (WGA) modified liposome as a vehicle for ophthalmic administration. Liposome loaded with 5-carboxyfluorescein (FAM) was prepared by lipid film hydration method. WGA was thiolated and then conjugated to the surface of the liposome via polyethylene glycol linker to constitute the WGA-modified and FAM-loaded liposome (WGA-LS/FAM). The amount of thiol groups on each WGA molecule was determined, and the bioactivity of WGA was estimated after it was modified to the surface of liposome. The physical and chemical features of the WGA-modified liposome were characterized and the ocular bioadhesive performance was evaluated in rats. The result showed that each thiolated WGA molecule was conjugated with 1.32 thiol groups. WGA-LS/FAM had a mean size of (97.40 +/- 1.39) nm, with a polydispersity index of 0.23 +/- 0.01. The entrapment efficacy of FAM was about (2.95 +/- 0.21)%, and only 4% of FAM leaked out of the liposome in 24 h. Erythrocyte agglutination test indicated that after modification WGA preserved the binding activity to glycoprotein. The in vivo ocular elimination of WGA-LS/FAM fitted first-order kinetics, and the elimination rate was significantly slower than that of the unmodified liposome, demonstrating WGA-modified liposome is bioadhesive and suitable for ophthalmic administration.
Absorption, Physicochemical
;
Adhesiveness
;
Administration, Ophthalmic
;
Animals
;
Drug Carriers
;
Eye
;
metabolism
;
Fluoresceins
;
chemistry
;
Liposomes
;
administration & dosage
;
chemistry
;
pharmacokinetics
;
Male
;
Particle Size
;
Polyethylene Glycols
;
chemistry
;
Rats
;
Rats, Sprague-Dawley
;
Wheat Germ Agglutinins
;
administration & dosage
;
chemistry
;
pharmacokinetics
7.Distribution of involved regional lymph nodes in recurrent and locally advanced breast cancer and its impact on target definition
Jian CHEN ; Jinli MA ; Shengjian ZHANG ; Zhaozhi YANG ; Gang CAI ; Yan FENG ; Xiaomao GUO ; Jiayi CHEN
Chinese Journal of Radiation Oncology 2011;20(2):123-127
Objective The frequency and the anatomic distribution of involved regional nodes in recurrent and locally advanced breast cancer were analyzed, in order to evaluate the rational of conventional regional node radiation technique and provide evidence for target definition of breast cancer . Methods Patients with recurrent or locally advanced breast cancer who were treated in our hospital from August 2003 to December 2009 were included in this study. 111 patients had contrast enhanced chest CT images of the whole regional nodes before treatment. The regional nodes were categorized into 8 anatomical substructures including medial and lateral supraclavicular nodes ( SC-M, SC-L), axilla nodes ( ALN )- Ⅰ , Ⅱ , Ⅲ,infraclavicular nodes (IFN), Rotter's nodes (RN) and internal mammary nodes (IMN). The frequency of involvement and anatomical distribution of the involved nodes on CT images were analyzed. Results A total of 111 patients were enrolled this study and 199 anatomical substructures with involved nodes were identified. The frequency of involvement were :SC-M 33, SC-L 21, ALN- Ⅰ 30, ALN-Ⅱ 25, ALN-Ⅲ + IFN 35, RN 27, IMN 28. Supraclavicular region and axilla were the most frequently involved area (72. 3% ).The average depth of the SC-M and SC-L nodes was 33.48 mm ± 10. 57 mm and 45.62 mm ±20. 45 mm,and 51.5% and 71.4% of the SC-M and SC-L nodes were located more than 3 cm deep from the skin. The axilla nodes were located cranial and caudal to the axillary vein in 5 and 20 locally advanced breast cancer patients and in 64 and 28 patients who received prior axillary dissection. The majority of involved IMN was located within the first 3 intercostal spaces (26/28). The average distance between the center of involved IMN and chest skin was 24. 23 mm ± 10. 28 mm. The average distance between the center of involved IMN and midline of the body was 29. 38 mm ±6. 7 mm. The center of involved IMN was 6.19 mm ±5.73 mm lateral and 5.73 mm ± 4. 56 mm posterior to the internal mammary vessels. Conclusions Conventional field design is unlikely to provide sufficient dose to the entire risk region because of individual differences.Individualized treatment planning based on CT would become feasible with increasing knowledge of natural risk of nodal involvement.
8.Analysis of clinical and imaging characteristics of infectious sacroiliac arthritis and review of literatures
Gang WANG ; Yanyan WANG ; Jian ZHU ; Jingyu JIN ; Zheng ZHAO ; Jianglin ZHANG ; Feng HUANG
Chinese Journal of Internal Medicine 2015;54(5):420-425
Objective To study the clinical and imaging characteristics of patients with infectious sacroiliac arthritis.Method Twenty-one patients diagnosed with infectious sacroiliac arthritis were analyzed retrospectively between 2000 and 2014.The chief complaint was pain in hip and lumbosacral area.Their clinical features,laboratory tests and pathological examination results as well as CT/MRI/PET-CT images were evaluated.Results There were nine males and thirteen females eighteen (85.7%) patients had unilateral sacroiliac joint involvement.Among these patients,three were diagnosed with brucellosis sacroiliac arthritis(BSI),eight patients with tuberculosis sacroiliac arthritis (TSI),and ten patients with non-brucellosis and non-tuberculosis infectious sacroiliac arthritis (ISI).For those patients with non-brucellosis and non-tuberculosis infectious sacroiliac arthritis,white blood cell count,erythrocyte sedimentation rate (ESR) and C-reactive protein (CRP)were dramatically increased.Twelve patients were diagnosed pathologically including 6 ISI,2 BSI and 4 TSI.Twelve patients and seventeen patients were scanned by CT and MRI respectively.Two patients undertook PET-CT examination.Antibiotic therapy showed significant therapeutic effects in all patients.Conclusion Infectious sacroiliac arthritis patients with hip or lumbosacral pain as the chief complaint can be easily misdiagnosed as spondyloarthritis.Comprehensive analysis of clinical features,imaging and laboratory findings is essential for accurate diagnosis.
9.Recent Development of Droplet Microfluidics in Digital Polymerase Chain Reaction
Yiqiang FAN ; Mei WANG ; Feng GAO ; Jian ZHUANG ; Gang TANG ; Yajun ZHANG
Chinese Journal of Analytical Chemistry 2016;(8):1300-1307
Digital polymerase chain reaction ( PCR) has been experiencing a rapid development during the past few years. Comparing with the traditional real-time quantitative PCR ( RT-qPCR) , using the same primer and probe, the accuracy for the absolute quantification of target gene is significantly improved. The development of digital PCR is directly related to the development of microfluidics. The integrated fluid circuit is an early combination of the microfluidics and digital PCR, which has a complicated fabrication process with high cost. Recently, researchers are trying to apply the droplet microfluidics in digital PCR, and the droplet microfluidic chip is able to generate millions of droplets within a short time. Each of these droplets containing no more than one target gene is a reaction chamber during the amplification process. After amplification, each droplet is tested to achieve the absolute quantification of the target gene. This paper reviews the recent progresses of droplet digital PCR, and the applications of droplet digital PCR in biological, medical and environmental fields.
10.Case-control study on effects of vacuum drainage on perioperative blood loss after total hip arthroplasty for the treatment of femoral neck fractures.
Guo-Gang LUO ; Hong-Zhen ZHANG ; Jian-Chuan YAO ; Zhong-Qin LIN ; Hai-Feng XIE
China Journal of Orthopaedics and Traumatology 2015;28(3):210-213
OBJECTIVETo compare postoperative blood loss under different negative pressures of drainage after total hip arthroplasty for the treatment of femoral neck fractures.
METHODSFrom January 1st to December 30th 2013, 74 patients with femoral neck fractures treated with total hip arthroplasty were randomly divided into two groups: high negative pressure drainage group and low negative pressure drainage group. In high negative pressure drainage group, there were 34 cases including 10 males and 24 females, with a mean age of (75.94 ± 9.02) years old, and the patients were treated with 60 kPa negative pressure of drainage. In the low negative pressure drainage group, there were 40 cases including 13 males and 27 females, with an average age of (74.93 ± 8.90) years old, and the patients were treated with 30 kPa negative pressure of drainage. The amount of total drainage, total blood loss, and hemoglobin change were compared between these two groups.
RESULTSAll the patients got primary healing without infections. In high negative pressure drainage group,the change of hemoglobin was (41.74 ± 15.69) g/L, total blood loss was (1,217.73 ± 459.50) ml and the drainage volume was (312.94 ± 103.44) ml; while in low negative pressure drainage group,the results were (34.90 ± 12.90) g/L, (904.01 ± 381.58) ml and (129.25 ± 44.25) ml separately. All the results in high negative pressure drainage group were higher than those in the other group. Three days after operation, the change of hemoglobin was (46.00 ± 13.29) g/L and total blood loss was (1,304.72 ± 421.75) ml; while in low negative pressure drainage group, the changes of hemoglobin was (43.87 ± 11.39) g/L and total blood loss was (1,196.78 ± 344.20) ml; there were no statistically significant differences between two groups.
CONCLUSIONWhen placing drainage devices after total hip arthroplasty for the treatment of femoral neck fractures, the level of negative pressure should be chosen according to preoperative level of hemoglobin and HCT in patients. For old patients with femoral neck fracture, low negative pressure is more suitable.
Aged ; Aged, 80 and over ; Arthroplasty, Replacement, Hip ; methods ; Case-Control Studies ; Female ; Femoral Neck Fractures ; surgery ; Humans ; Male ; Middle Aged ; Negative-Pressure Wound Therapy ; Postoperative Hemorrhage ; prevention & control