1.Effect of Laparoscopic Microwave Ablation on Large Liver Cancer
Chinese Journal of Minimally Invasive Surgery 2005;0(11):-
Objective To investigate the efficacy of microwave ablation for big liver cancer by using laparoscopy.MethodsFrom August 2000 to October 2006,28 patients with large big liver cancer(over 5 cm in diameter)was treated by microwave ablation under the guidance of a laparoscope.On each tumor nodule,3 to 5 electrode insertions was applied.And for each lesion,the treatment was performed for 1 to 3 times.Results The complete ablation rate of this series was 78.6%(22/28),and the rate of local recurrence was 35.7%(10/28).1-,3-,and 5-year survival rates were 75.0%(21/28),57.1%(12/21),and 36.4%(4/11),respectively.Conclusions Laparoscopic microwave ablation is safe and effective for liver cancer.The procedure can increased the efficacy of the microwave by enlarging the extent of the ablation.
2.Primary non-Hodgkin lymphoma of skeletal muscle:imaging findings
Liangping ZHOU ; Weijun PENG ; Wentao YANG ; Feng TANG ; Jian MAO
Chinese Journal of Radiology 2000;0(12):-
Objective To analyze the imaging manifestations of primary non-Hodgkin lymphoma of skeletal muscle and improve the recognition of this rare disease.Methods Five cases of primary non-Hodgkin lymphoma of skeletal muscle proved pathologically underwent imaging exam,including MRI and CT in 3 cases,only MRI in 1 case,only CT in 1 case,X-ray in 2 cases and bone scintigraphy in 2 cases.Results Diffuse enlargements of involved muscle with presentation of overall configuration were observed in all five cases.All 4 cases manifested as homogeneous soft masses,which is isoattenuating to normal muscle on unenhanced CT images.After intravenous injection of contrast media,the masses enhanced homogeneously and slightly(2 cases)or moderately(1 case)on CT images.The lesions were homogenous and had isointense or slightly low signal intensity compared with that of uninvolved muscle on T1-weighted images and high signal intensity on T2-weighted images.After intravenous injection of contrast media,all 2 cases enhanced homogeneously and moderately with the enhanced signal intensity of involved muscle greatly higher than that of uninvolved muscle on MR images.Two cases of X-ray plain showed no destruction of bone and 2 cases of bone scintigraphy exams showed increased radiotracer uptake of involved muscle with no infiltration of bone marrow.Conclusion There are several characteristics on the imaging of primary non-Hodgkin lymphoma of skeletal muscle.MRI is the optimal imaging method for the diagnosis of this disease.
3.Clinical effect of femtosecond laser assisted penetrating corneal transplantation operation
Hong-Jian, ZHOU ; Feng, WEN ; Bin, LU ; Li-Ping, MAO
International Eye Science 2014;(10):1822-1824
AIM:To observe the clinical effect of femtosecond laser assisted penetrating keratoplasty.
METHODS: Twenty-four cases ( 24 eyes ) with corneal lesions were performed with femtosecond laser assisted penetrating keratoplasty. Preoperative and postoperative endothelial cell density and visual quality were compared.RESULTS: One week after operation, corneal grafts were clear in 21 eyes (87. 5%), mild cloudy in 3 eyes (12.5%);visual acuity ≥0. 5 in 18 eyes (75. 0%), 0. 2 ~0.4 in 6 eyes ( 25. 0%). After 3mo the mean corneal astigmatism was 2. 16±0. 21D ( range 2. 25 ~ 3. 09D). Compared to conventional penetrating keratoplasty which mean corneal astigmatism was average 3. 67±0. 38D after operation, there was significant difference between two groups ( P< 0. 05 ). There were significant differences between preoperative and postoperative visual acuity and astigmatism (both P<0. 05).
CONCLUSION: Femtosecond laser assisted penetrating corneal transplantation operation can improve patient's visual quality. And compared to traditional penetrating keratoplasty astigmatism decreased significantly, incision can be made in individual shape more precisely and neatly.
4.Establishment of model of diabetes and lens posterior capsule opacification induced by alloxan in rabbit
Qi, WEI ; Jin-mao, CHEN ; Min-li, HUANG ; Xia, LI ; Jian-feng, HE ; Shao-jian, TAN
Chinese Journal of Experimental Ophthalmology 2011;29(2):130-134
Background The establishment of diabetic animal model is a crucial step for the study about diabetic eye diseases. At present,the main modeling method include the injection of streptozotocin and alloxan. But the shortcoming of the former is an expensive price, and that of the later is high death rate of animals. Objective This experiment was to discuss the way which decrease the death of alloxan-injected animal and explore the effects of high blood glucose on the posterior capsular opacification (PCO). Methods Forty clean healthy male New Zealand white rabbits were randomly divided into 2 groups. 90mg/kg of alloxan were injected via ear vein once in 20 rabbits to create the diabetic animal models,and the equivalent amount of normal saline solution was injected at the same way as normal blood glucose group. The successful models were selected in the animals with the blood glucose level over 12. 0 mmol/L two weeks later, and PCO of lens were graded based on the method of Odrieh under the slit lamp. Extracapsular lens extraction was then performed on the right eye of rabbits in both groups, and the posterior capsules were obtained from these eyes at the 6th, 10th and 14th days after operation. The expression of proliferating cell nuclear antigen ( PCNA ) in posterior capsular lens epithelial cell was detected by immunohistochemistry. Results The modeling successful rate was 70% after injection of alloxan. The body weight of rabbits in high blood glucose group was significantly lowed and the blood glucose was significantly elevated in comparison with normal blood glucose group ( all P<0. 05). Two weeks after surgery ,2 eyes occurred 2 grade of PCO and only one eye showed the 1 grade of PCO in the high blood glucose group. However, 1 grade of PCO was found in 3 eyes in the normal blood glucose group. Biopsy revealed that PCNA was positively expressed in the cell nuclei of LECs in high blood glucose group rather than the normal blood glucose group from the 10th day after surgery. The proliferation index of PCNA was 0. 86±0. 04 and 0. 25±0. 03 respectively in high blood glucose group and normal blood glucose group, showing a significant difference between them (t = -16. 171 ,P = 0. 000). Conclusion Stable diabetic models of rabbits can be created by intravenous injection of 90 mg/kg alloxan. High blood glucose level is one of the important factors for the development of PCO.
5.Diffusion-weighted MRI of the breast:lesion characterization and parameter selection
Ya-Jia GU ; Xiao-Yuan FENG ; Feng TANG ; Wei-Jun PENG ; Jian MAO ; Wen-Tao YANG ;
Chinese Journal of Radiology 2001;0(05):-
Objective To evaluate the b value of diffusion-weighted(DW)MRI in distinguishing between benign and malignant breast lesions.Methods Three diffusion-weighted sequences were implemented with 500,1000 and 2000 s/mm~2 b values respectively on 95 breast lesions in 83 patients.All lesions were confirmed by pathology.The apparent diffusion coefficient(ADC)values and signal intensity (SI)were recorded and compared in different lesions(breast cancer,benign lesion,cyst and normal beast tissue)with the same b value and the same lesions with the different b values.Results(1)The mean ADC value and SI of breast cancer were 1.375?0.378 and 839.713?360.493 respectively with b= 500 s/mm~2,1.176?0.311 and 459.314?229.609 with b=1000 s/mm~2,0.824?0.198 and 243.825? 110.616 with b=2000 s/mm~2.The differences in the mean ADC value were significant between two type lesions(cancer and benign lesion,cancer and cyst,cancer and normal breast tissue)with b values of 500 s/mm~2 and 1000 s/mm~2.But the significant differenee was only seen between cancer and benign lesions when b value was 2000 s/mm~2.(2)The one-side upper limits of 95% confidence interval of mean ADCs were adopted as the point to separate the malignant from the benign lesions,the sensitivity was 70.92%, 70.73% and 69.77%,the specificity was 77.19%,75.70% and 54.76%,the accuracy was 77.12%, 74.32% and 62.35% respectively with b values of 500 s/mm~2,1000 s/mm~2 and 2000 s/mm~2.The areas under ROC eurves were Az_(500)=0.775?0.046(P0.05).Conclusion DWI MRI is useful for the differential diagnosis of breast lesions with b values of 500 s/mm~2 and 1000 s/mm~2.
6.Evaluation of quantitative dynamic contrast enhanced MRI in differential diagnosis of breast lesions
Ruimin LI ; Yajia GU ; Jian MAO ; Weijun PENG ; Fei SUN ; Hongna TAN ; Feng TANG ; Min QIAN
Chinese Journal of Radiology 2011;45(2):164-169
Objective To evaluate the value of quantitative 3T dynamic contrast enhanced MRI in the diagnosis of breast lesions. Methods One-hundred and eighteen patients suspected of breast lesions underwent MRI examination. A 3.0 T MR scanner was used to obtain the quantitative MR pharmacokinetic parameters: Ktrans( volume transfer constant), Kep (exchange rate constant) and Ve (extravascular extracellular volume fraction). The mean Ktrans, Kep and Ve of malignant, benign and normal glandular tissues were calculated and compared each other using LSD method. Independent sample t test was used between invasive ductal carcinoma and ductal carcinoma in situ (microinvasion included). Finally, the areas under the ROC curve (AUC) of Ktrans, Kep and Ve between malignant and benign lesions were compared. Results The mean Ktrans, Kep and Ve of malignant lesions (n=87) were (1.010±0.580) min-1, (1.634 ± 1.481) min-1 and (0.735 ±0.273); the mean Ktrans, Kep and Ve of benign lesions (n=23) were (0.331±0.192) min - 1, (0.417±0.324) min - 1 and (0.847±0.291); and the mean Ktrans, Kep and Ve of normal glandular tissues (n =83) were (0.051 ±0.028) min-1, (0.133±0.125) min-1 and (0.597±0.354), respectively. There were significant differences between normal glandular tissues and benign lesions, normal glandular tissues and malignant lesions, benign and malignant lesions in Ktrans (t=9.681, 11.189, 5. 590, respectively, P < 0. 01 ), normal glandular tissues and malignant lesions, benign and malignant lesions in Kep(t =5. 287, 3. 874, P<0. 05). There were a statistic differences between normal glandular tissues and benign lesions, normal glandular tissues and malignant lesions in Ve(t =2. 932, 2. 562 ,P <0. 05). There were no significant differences between normal glandular tissues and benign lesions in Kep, benign and malignant lesions in Ve ( t = 0. 760, 0. 832, P > 0.05 ),invasive ductal carcinoma and ductal carcinoma in situ (microinvasion included) in Ktrans, Kep and Ve(t =0.834,0.075,0.454,P>0.05). The areas under the ROC curve (AUC) of Ktrans, Kep and Ve between malignant and benign lesions were 0. 934, 0. 941 and 0. 659. The sensitivity of Ktrans, Kep and Ve were 77.01% ,91.95% ,56. 32% and the specificity of Ktrans, Kep and Ve were 95. 65%, 86. 96%, 78.26% for the differential diagnosis of breast lesions if taken the maximum Youden's index as cut-off. Conclusion The differential diagnosis of benign and malignant breast lesions by Ktrans, Kep is applicable.
7.Quality standard study on Mori Cortex liquid extract.
Mao-feng LIU ; Mei-ping XIE ; Lan LI ; An-qi LU ; Jian-gong SHI ; Su-juan WANG
China Journal of Chinese Materia Medica 2015;40(10):1850-1854
A reasonable and practicable quality standard was developed for mori liquid extract from different sources by TLC, HPLC and fingerprint technology. In TLC method, the compounds were separated on polyamide film using glacial acetic acid-water (1: 3) as mobile phase at a UV wavelength of 365 nm. All qualified samples had the spots of the same color as the control herb and substance. The RP-HPLC method was used to determine the content of mulberroside A with mobile phase of methanol-water (25: 75) at a wave-length of 326 nm. The mulberroside A was in good linear with a regression equation of Y = 46.965X (r = 0.999 6) in the range of 4.6 - 228 mg x L(-1). In 14 batches of samples, the mulberroside A in 4 batches of them was less than 0.5 g x L(-1), and was more than 2.0 g x L(-1) in the other batches. It was suggested that the content limit of mulberroside A should be no less than 1.5 g x L(-1). The HPLC fingerprints were evaluated by the similarities. It has found that the similarities of different mori liquid extracts were very low and the chemical diversity of mori cortex was the major factor of similarity. Moreover, the process impact was minimal. Thus the fingerprint was not included in this quality standard.
China
;
Chromatography, High Pressure Liquid
;
Disaccharides
;
chemistry
;
isolation & purification
;
Drugs, Chinese Herbal
;
chemistry
;
isolation & purification
;
standards
;
Morus
;
chemistry
;
Quality Control
;
Stilbenes
;
chemistry
;
isolation & purification
8.Design and Application of Distal Radius Anatomical Shape Bracket Splints.
Mao WU ; Yong LIU ; Jie-feng SHEN ; Yong MA ; Jian-wei WANG
Chinese Journal of Integrated Traditional and Western Medicine 2015;35(5):555-558
OBJECTIVETo observe the clinical effect of anatomic shape bracket splints designed by 3D-MAX software.
METHODSHealthy adult volunteers' forearms and wrist data were measured and processed by 3D-MAX software. Then we designed and made anatomic shape bracket splints. Totally 60 distal radial fracture patients were equally assigned to the test group and the control group. After manual reduction, patients in the test group used anatomic shape bracket splints, while those in the control group used common splints. The palmar dip angle, ulnar fleet angle, and radius height of standard X-ray in normal and lateral positions were measured after treatment, at 1, 3, and 6 week after treatment, respectively. Meanwhile, the incidence of complications was recorded during the whole treatment process.
RESULTSCompared with the control group, the palmar dip angle and ulnar fleet angle were larger in the test group after one week of treatment (P < 0.05). The radius height of the treatment group was higher after one, three, and six weeks of treatment (P < 0.05). Compared with the control group, the incidence of complications was obviously less in the test group (P < 0.05).
CONCLUSIONSAnatomic shape bracket splints designed by 3D-MAX software fit local anatomic features and need no more shaping. Its easier use with lesser complications could maintain the stability of bone fracture better.
Adult ; Humans ; Imaging, Three-Dimensional ; Radius ; Radius Fractures ; therapy ; Splints ; Wrist Joint
9.Preliminary application of real-time contrast-enhanced ultrasound in diagnosis of papillary thyroid microcarcinoma
Yuemingming JIANG ; Youfeng XU ; Libin CHEN ; Feng MAO ; Jian LU ; Nan SU ; Shengmin ZHANG
Chinese Journal of Ultrasonography 2015;24(10):882-885
Objective To explore the imaging features of papillary thyroid microcarcinoma(PTMC) with real time contrast-enhanced ultrasound.Methods One hundredand forty-three cases with 149 thyroid nodules(no diffuse lession) were divided into two groups according to the diameter size(group 1,<0.5 cm;group 2,0.5-1.0 cm) and examined by contrast-enhanced ultrasound during preoperation.Pathology was followed up as golden diagnosis criteria.Results Seventy-five benign tumors and 74 PTMC were confirmed by pathology.There were significant differences in echoes homogeneity between benign and malignant tumors in group 2(W =1 029.5,Z =-5.524,P =0.000) but no in group 1(W =933.0,Z =-1.738,P =0.082).And nonhomogeneous enhancement were showed in most PTMC in group 2.But most PTMC showed homogeneous enhancement in group 1.Conclusions Contrast-enhanced ultrasound is valuable in diagnosis of PTMC with the diameter size of 0.5-1.0 cm.
10.Effect of kistrin on expression of collagen type IV in lens posterior capsule
Feng-ting, HU ; Shao-jian, TAN ; Hao, LIANG ; Jian-feng, HE ; Xia, LI ; Min-li, HUANG ; Jin-mao, CHEN ; Ying-ying, CHEN
Chinese Journal of Experimental Ophthalmology 2012;30(1):37-40
BackgroundThe proliferation of lens epithelial cellsLECs) following extracapsular cataract extraction is the biological basis of posterior capsular collagen and cataract formation.Disintegrin is certified to competitively bind the integrin with extracellular matrix and therefore prevent the posterior capsular opacification (PCO).But,its molecular mechanism is below understand.ObjectiveThe present study was to investigative the effects of disintegrin (kistrin) on the expression of collagen in lens posterior capsular.MethodsThe right eyes of 24 New Zealand white rabbits received transparent lens extracapsular enudeation and were randomly divided into two groups using random number table,0.2 ml of kistrin ( 80 mg/L) was intracapsularly injected at end of the operation in 12 eyes ( kistrin group) and the same volume of normal saline solution was used at the same way in other 12 operative eyes ( normal saline group).The PCO was graded in postoperative 1,3,5,7,14 days on Odrich' s criteria under the slit lamp.The lens section was prepared at 14 days and 3 months after operation.Haematoxylin and eosin stain was used to examine the proliferation of LECs in posterior capsule; Masson stain was used to observe the collagenous fiber formation in capsule bag,and the expression of collagen type Ⅳ was detected by immunochemistry.Results No significant difference in the number PCO eye was found in postoperative 14 days between normal saline group and kistrin group ( P =0.093 ).However,the eye numbers of 2-3 grades of PCO were significant increased in normal saline group compared with kistrin group in 1,2,3 months after operation( P=0.041,0.014,0.022).In the operative 14 days,staining and adhesion of LECs in posterior capsule were more in normal saline group than kistrin group,and the fibrocytes in capsule were evidently increased in normal saline group in 3 months.Masson stain certified that the blue stain was seen to be stronger and more in posterior capsule in normal saline group in comparison with kistrin group in 3 months after operation,and the immunochemistry showed that the gray values of collagen type Ⅳ in posterior capsule were significant lower in normal saline group compared with kistrin group in both 14 days and 3 months after operation (P=0.000,0.001 ).ConclusionsKistrin can suppresses the proliferation of LECs and collagen type Ⅳ on rabbit lens posterior capsular after transparent lens extracapsular enudeation.