2.Study on transcatheter ASD occlusion using modified atrial septal defect occluder with no stainless steel screw in canine model
Bin XUAN ; Yong-Wen QIN ; Jian-Qiang HU ; Hong WU ;
Journal of Interventional Radiology 2006;0(11):-
Objective To evaluate the safety,biocompatibility and efficacy of transcatheter closure of atrial septal defect(ASD)with no stainless-steel-screw occluder in canine model.Methods The device was constructed from superelastic Nitinol wires tightly woven into two flat disks and sewed with polyester fibers inside,with a pliable loop on the right-atrial-disk of the device,connecting to the delivery cable.ASD was created by transcatheter puncture and balloon dilatation and then closed by occluder under fluoroscopy in the catheterization laboratory.The location and the influence of the implanted device on function of tricuspid valve and mitral valve were evaluated by echocardiography.At 1,2,3 and 6 months after the operation,the animals were killed and autopsy was conducted.Results Eight dogs with puncture-produced ASD underwent ASD closing procedure successfully.The occluder showed no influence on the function of MV and AV demonstrated by echocardiogram.The two disks of the implanted device were covered with a smooth intact neogenesis layer in all dogs.Endocardial cells fully covered the surface of the two disk without inflammating reaction 3 months later. There was no evidence of corrosion on the surface of the nitinol wire removed from the dog after 6 months.Light microscopic examination of the liver,kidney,lung and spleen showed no evidence of embolization and inflammation.Conclusion Transcatheter ASD occlusion with new-type occluder is safe,feasible,effective and good biocompatibility with a good prospective clinical application.
3.Optimization of the Extraction Technology of Oleanolic Acid from Elsholtzia Bodinieri V.by Orthogonal Test
Haobin HU ; Hong CAO ; Xudong ZHENG ; Yufeng JIAN ; Jianxin LIU
China Pharmacy 2001;0(09):-
OBJECTIVE:To optimize the extraction technology of oleanolic acid from Elsholtzia bodinieri V.METHODS:The extraction technology was optimized by orthogonal-test using microwave-assisted dynamic extraction method with oleanolic acid as index;And the content of oleanolic acid was determined by TLC-spectrophotometry.RESULTS:The opti-mum extraction condition was described as follows,the microwave power is600W with methanol as extracting solvent,the flow rate was8ml/min and the inner diameter of extraction tube was10mm.CONCLUSIONS:The microwave-assisted dynamic extraction method is simple,safe,rapid,accurate and with high extraction yield.The optimized extraction technology is stable and feasible,and suitable for industrialized production.
4.Short-term clinical efficacy of flap-free Epi-LASIK and Epi-LASIK for high myopia
Chun-yan, WANG ; Man-hong, YUAN ; Jian-rong, HU
Chinese Journal of Experimental Ophthalmology 2011;29(12):1120-1124
Background Compare with the lamellar laser refractive surgery,the laser slip on the surface operation is a better method in the correct of refractive error without the flap-related complications.However,whether to remain corneal epithelial flap and its influence for epithelial healing and visual restoration are still under investigation.Objective The aim of this study was to compare the short-term clinical efficacy of epipolis laser insitu keratomileusis (Epi-LASIK) and flap-free Epi-LASIK for correction of refractive error in high myopia.Methods The paired control design was adopted.Sixty eyes of consecutive 30 patients with high myopia were collected in this study.The written consent form was obtained from each patients prior to operation.Regular EpiLASIK was performed in the right eyes and the flap-free Epi-LASIK was carried out in the left eyes.Patients were followed-up for one month.The postoperative ocular irritation symptoms were scored,and the healing period of corneal epithelium and uncorrected visual acuity were examined at 1,3 and 5 days after operation.The naked visual acuity,diopter,best corrected visual acuity and the grading of haze were recorded and compared between the two groups at one month after operation.Results After surgery,the scores of corneal irritation were 3.13 ±0.43 and 3.30±0.47on the first day,showing insignificant differences between these two groups (t =- 1.54,P>0.05 ).However,there existed statistically significant difference in the scores of corneal irritation on the third day after operation between the two groups (t =- 17.95,P<0.01 ).The average time of corneal epithelial healing were (2.58 ±0.49 ) days in the flapfree Epi-LASIK group and ( 3.98 ±0.74) days in Epi-LASIK group with the significant difference between them (t=-11.36,P<0.01 ).There was no statistical difference in uncorrected visual acuity in the first day (0.59±0.12 vs 0.58±0.11,t=0.39,P>0.05),the fifth day (0.69±0.08 vs 0.67±0.09,t=0.84,P>0.05) and 1 month (t =-1.90,P>0.05 ).No significant difference was seen in the diopter between the two groups in 1 month after surgery (-1.03±0.45 vs -1.07 ±0.38,t =-0.31,P>0.05 ).The eye numbers of corneal haze for 0 grade were 27 ( 90.00% ) and over the 0.5 grade were 3 ( 10.00% ) in flap-free Epi-LASIK group respectively,and those of corneal haze for 0 grade were 26(86.66% ) and above the 0.5 grade were 4 (13.33%) in Epi-LASIK group respectively,showing a considerably difference between the two groups (x2 =0.0031,P>0.05).Conclusions Both the flapfree or reserved epithelial Epi-LASIK allow the safe and effective correction of refractive error in high myopia,showing good predictability and stability in short term.Flap-free Epi-LASIK can relieve the corneal irritation symptom and accelerate the healing of corneal epithelium and recovery of visual acuity.
5.Comparison on eye biometry of Lenstar 900, A-scan ultrasound and keratometer in patients with cataract
Dan, HU ; Gang-Ping, ZHAO ; Jian-Hong, YU ; Xiao, ZHENG
International Eye Science 2014;(8):1440-1443
AIM:To investigate the differences among Lenstar 900, A-scan ultrasound and keratometer in measurement of axial length ( AL ) , anterior chamber depth ( ACD ) and corneal curvature ( K1 , K2 , Km ) , and evaluate the consistency of the instruments, with the purpose providing references for the clinical application of Lenstar 900.
METHODS: In this study we picked up 36 patients ( 50 eyes ) underwent cataract surgery, and lens nucleus hardness were under level IV. Before the operation, AL, ACD and K1 , K2 , Km were measured by Lenstar 900, A-scan ultrasound and keratometer respectively. The differences between the results were compared by the paired t-test. The correlation of the results was analyzed by Pearson correlation analysis, and the consistency was measured by Bland-Ahamn method.
RESULTS: The mean AL and ACD values measured by Lenstar 900 and A-scan ultrasound had no significantly statistic differences (P>0. 05). The K1, K2, Km measured by Lenstar 900 and keratometer were not significantly statistical different (P>0. 05). The results measured by these three instruments had close linearity correlation ( r>0.9, P<0. 01). The consistency of the results was well in Bland-Ahamn analysis.
CONCLUSION:The preoperatively biometric result of Lenstar 900, A - scan ultrasound and keratometer in patients with cataract are all reliable, and they can be substituted by each other. However, Lenstar 900 can not only measure AL, ACD and corneal curvature at the same time, but also cornal thickness, lens thickness, white to white, pupil size, optical axis eccentricity, retinal thickness and so on. It has a number of advantages such as non-touching, convenient and efficient, and can be recommended to use widely.
6.Research on the reliability of the Akagi line as a reference axis to guide for rotational alignment of the proximal tibial component in total knee arthroplasty.
Hua-chen YU ; Hong WEN ; Yu ZHANG ; Yue-zheng HU ; Jian-bin WU ; Jian-zhong KONG
China Journal of Orthopaedics and Traumatology 2015;28(10):884-887
OBJECTIVETo study on the reliability of the Akagi line as a reference axis to guide for rotational alignment of the proximal tibial component in total knee arthroplasty (TKA) the rotational alignment reference bony landmarks of the proximal tibial component on magnetic resonance image (MRI) were measured.
METHODSFrom January 2010 to December 2013, 80 normal knees of Chinese volunteers including 35 males and 45 females with an average age of (35.4±6.1) years were reviewed. The images of the knees were obtained by MRI. The surgical epicondylar axis (STEA) was identified in the femoral transverse sections and then was projected to the side of tibia, forming the SETA'. A line connecting the medial border of the patellar tendon and the middle of the posterior cruciate ligament insertion (Akagi line) and its vertical line (AK), as well as a line connecting the medial 1/3 of the patellar tendon and the middle of the posterior cruciate ligament insertion and its vertical line (AP), were identified in the tibial transverse sections. The angles were measured between the AK, AP and STEA'.
RESULTSThe angle between AK and STEA' was (0.59±2.07)°, and there was no significant difference between the two lines (t=-2.54, P=0.13). The mean angle between AP and STEA' was (3.21±2.04)°, and there was a significant difference between the two lines (t=14.05, P<0.05). There was a significant difference between the AK and AP (t=-11.68, P<0.05).
CONCLUSIONThe reliability of the Akagi line as a reference axis to guide for rotational alignment of the proximal tibial component in TKA is good.
Adolescent ; Adult ; Arthroplasty, Replacement, Knee ; methods ; Female ; Humans ; Male ; Middle Aged ; Reproducibility of Results ; Rotation ; Tibia ; surgery
7.The Technique of Metallic Self-expanding Stents in Treating Malignant Gastroduodenal Obstruction
Xin WEI ; Liming ZHONG ; Hong HU ; Jian YOU ; Dacheng REN ; Xin HU ; Rongqiang PAN
Journal of Practical Radiology 2010;26(2):255-257
Objective To explore the methods and curative effect of metallic self-expanding stent in inoperable malignant gas-troduodenal obstruction. Methods The data of 15 cases with gastroduodenal obstruction including 9 cases of carcinoma of head of pancreas and 6 cases of carcinoma of stomach were analyzed retrospectively. The operative procedures of the stent implanted and the tors accepted more radiation dose because the manipulation was under the fluoroscopy in a short distance and with a full field of view. sions, the postoperative eating habit and the development turnover of disease. The main death reasons were tumor transfer and sys-tem exhaustion. Conclusion To pay close attention to the details and main points of operative procedure is the key point to implant stent successfully for malignant gastroduodenal obstruction. The determinative factor to influence the curative effect is the develop-ment turnover of tumor.
8.Study on establishment of virtual three-dimensional model of the virtual artery and interventional devices and its application value
Xin WEI ; Liming ZHONG ; Jian YOU ; Hong HU ; Kongqiong HU ; Xiaowei ZHAO ; Xiaoxia WEN
Journal of Practical Radiology 2014;(6):995-998
Objective To explore the establishment method of virtual three-dimensional model of the virtual artery and interven-tional devices,and its application value.Methods The virtual models including virtual artery system,catheter,guide wire,stent and coil were established by using the three-dimensional moulding software of 3D Studio MAX R3.The study about interventional preoperative simulation and assistant instruction were run in personal computer.Results ①All the virtual instruments and real in-struments were highly similar shape,the arterial system in the visual display was similar to realistic system.②All arteries branches had own name,could be arbitrarily adjusted curvature,diameter and established the lesion morphology.③The reference value of preoperative simulation results to guide the actual surgery included following aspects:to guide the reasonable shaping of micro-cathe-ter and micro-guide wire tip,to plan the coil and stent deployment location,number and size.④In training and teaching,the preop-erative simulation could assist doctors in learning and remembering the artery branch and establishing the concept of three-dimen-sional space,and enhanceing the intention understanding of surgery.Conclusion The establishment method of virtual model of the virtual artery and interventional devices is reliable.The preoperative simulation results can be used to guide practical operation with relatively high accuracy,and it has an important supporting role for the teaching and training of medical students.
9.Establishment of virtual three-dimensional model for intravascular interventional devices and its clinical value
Xin WEI ; Liming ZHONG ; Xiaodong XIE ; Chaohua WANG ; Jian YOU ; Hong HU ; Kongqiong HU ; Xiaowei ZHAO
Chinese Journal of Radiology 2012;46(4):359-362
Objective To explore virtual three-dimensional (3D)model for intravascular interventional devices,the method of preoperative simulation and its value in clinical work.MethodsThe virtual models including catheter,guide wire,stent and coil were established by using the 3D moulding software of 3D Studio MAX R3. The interventional preoperative simulation was performed on personal computer including 21 patients of cerebral aneurysm embolization ( anterior communicating artery 5,posterior communicating artery 10,middle cerebral artery 3,internal carotid artery 2,and vertebral artery 1 ),during interventional procedures,the surgeon relied on the simulation results for plastic micro-guide wire,catheter and the release of micro-coils and stents.Results( 1 ) All the virtual instruments and real instruments had similar shape,the overall tine for constructing virtual model was about 20 hours.The preoperative simulation took 50 to 80 minutes. (2) The simulation result of catheter insertion in the 18 cases had relevant value to guide micro-catheter,molding micro-guide wire tip,and shortened the operating time.For embolization,the simulation results of filling coil and releasing stent were similar to surgical results in 76% of the patients (16/21).(3)For teaching and training,93% (38/41) of doctors in training believed that preoperative simulation facilitated the understanding of surgery. ConclusionsThe method of virtual model of intravascular interventional devices was reliable.The preoperative simulation results could be used to guide practical clinical operation with relatively high degree of similarity,and could play a role in promoting researches on interventional virtual operations.
10.Three types of induced bursting rhythm in rat injured nerves.
Yu-Bin DUAN ; San-Jue HU ; Zhong JIAN ; Jian-Hong DUAN
Acta Physiologica Sinica 2002;54(4):329-332
Firing patterns of injured nerve fibers were recorded using the single-fiber firing recording technique. Under the same background firing pattern, three types of bursting were induced separately by EGTA, veratridine or high [Ca(2+)](o) in the same type of nerve fibers. The results suggest that different firing patterns are related to different stimuli, which means that each firing pattern carries corresponding neural information.
Action Potentials
;
Animals
;
Calcium
;
pharmacology
;
Egtazic Acid
;
pharmacology
;
Nerve Fibers
;
drug effects
;
pathology
;
Rats
;
Veratridine
;
pharmacology