2.Recent Development of Wearable Microfluidics Applied in Body Fluid Testing and Drug Delivery
Yiqiang FAN ; Feng GAO ; Mei WANG ; Jian ZHUANG ; Gang TANG ; Yajun ZHANG
Chinese Journal of Analytical Chemistry 2017;45(3):455-463
wearable microfluidics have wide applications in medical, sports and military field. with the help of wearable microfluidics, through the direct physical contact between the chip and skin, the pH, glucose, lactate, sodium/potassium, calcium and heavy metal in the body fluid can be detected from sweat, tear and saliva without puncture for blood. And these information are of great importance for the monitoring of vital signs and disease diagnosis. This paper introduced the most recent development and applications of the wearable microfluidics in the body fluid testing and drug delivery. The up-to-date research development for the drug delivery using wearable microfluidics was also briefly introduced in this article. The forecast of the emerging trend for wearable microfluidics and discussion of potential technique barriers was also provided at the end of this article.
3.The design and clinical application of a new type of disposable heparin free dialysis tube
Chunyan WU ; Yiyu ZHUANG ; Jianbin SHI ; Yingjuan YING ; Caiping ZHOU ; Jian FENG
Chinese Journal of Practical Nursing 2017;33(18):1374-1377
Objective To investigate the clinical effect of a new type of disposable heparin freedialysis tube in uremic patients without heparin dialysis. Methods A total of 110 patients withoutheparin dialysis were divided into control group and observation group by random digits table method with55 cases each. Based on the same pre dialysis and dialysis for heparin saline flushing of discontinuoussaline on the control group using the traditional dialysis pipe for hemodialysis without heparin, theobservation group used disposable non heparin dialysis pipe for hemodialysis without heparin. The numberof patients with venous catheter blockage, blood loss and completion of dialysis time in two groups wasrecorded. Results The number of patients with venous catheter blockage, blood loss and completion ofdialysis time was 6, 6, 47 cases in control group and 0, 0, 54 cases in observation group. The differences were statistically significant (χ2=4.407, 4.407, 4.356, P<0.05). Conclusions The new disposableheparin free dialysis tube can reduce the loss of blood and prolong the treatment time, and the operation issimple, safe and effective, and has good application value and application prospect.
4.Recent Development of Droplet Microfluidics in Digital Polymerase Chain Reaction
Yiqiang FAN ; Mei WANG ; Feng GAO ; Jian ZHUANG ; Gang TANG ; Yajun ZHANG
Chinese Journal of Analytical Chemistry 2016;(8):1300-1307
Digital polymerase chain reaction ( PCR) has been experiencing a rapid development during the past few years. Comparing with the traditional real-time quantitative PCR ( RT-qPCR) , using the same primer and probe, the accuracy for the absolute quantification of target gene is significantly improved. The development of digital PCR is directly related to the development of microfluidics. The integrated fluid circuit is an early combination of the microfluidics and digital PCR, which has a complicated fabrication process with high cost. Recently, researchers are trying to apply the droplet microfluidics in digital PCR, and the droplet microfluidic chip is able to generate millions of droplets within a short time. Each of these droplets containing no more than one target gene is a reaction chamber during the amplification process. After amplification, each droplet is tested to achieve the absolute quantification of the target gene. This paper reviews the recent progresses of droplet digital PCR, and the applications of droplet digital PCR in biological, medical and environmental fields.
5.The experimental study on effects of nuclear factor-κBp65 antisense oligonueleotide on liver fibrosis
Yu ZHOU ; Kequan CHEN ; Shicai YE ; Zhuang WANG ; Jian LIANG ; Ronghuo LIU ; Zhiling TANG ; Hao WANG ; Xiao FENG ; Wengtao YE
Chinese Journal of Digestion 2009;29(4):254-257
Objective To investigate the effect of the nuclear factor (NF)-κBp65 antisense oligonucleotide (ASODN) on NF-κB activity and expression of interleukin(IL)-6 in hepatic stellate cells (HSC). Methods The HSC were separated from rats and cultured. The toxicity of NF-κBp65 ASODN on HSC were detected by Trypan blue exclusion staining and the NF-κB activity was determined by EMSA. The expressions of IL-6 mRNA and protein were meaured by RT-PCR and ELISA, respectively. Results In vitro, no toxicity of ASODN on HSC was observed at the concentrations of 0. 001 to 1.0 μmol/L. NF-κB activity was increased after stimulating HSC with tumor necrosis factor (TNF)α, whereas it was weakened in a dose dependent manner when HSC were cultured with ASODN (concentration from 0. 001 to 1.0 μmol/L). At the same time, the expressions of IL-6 mRNA and protein induced by TNFα were decreased after transfected with ASODN at concentrations of 0.001- 1. 0 μmol/L in a dose dependent manner. Conclusion ASODN may specifically inhibit either the activiy of NF-κB or expression of IL-6, which provides the theoretical basis that ASODN may use to treat fibrosis of the liver.
6.Research Progress of Pathology of Gout and Clinical Treatment with Traditional Chinese and Western Medicine
Jian-long SHU ; Feng-zhen LI ; Yu-wang QIN
Chinese Journal of Experimental Traditional Medical Formulae 2020;26(2):218-227
With the improvement of people's living standard and the change of dietary structure, the prevalence of gout has increased gradually with the increased intake of protein, sugar and fat. There has been a positive correlation between gout and age, and the age of onset decreased gradually. The inflammation induced by sodium urate crystal is the pathological basis of gout, which activates innate immunity, releases many kinds of inflammatory mediators, such as interleukin(IL)-1
8.Assessment of the performance of an automated analysis system in detecting C3 and C4.
Lei SUN ; Xian-zhang HUANG ; Jun-hua ZHUANG ; Jian-hua XU ; Lian-ying LIN ; Pei-feng KE
Journal of Southern Medical University 2009;29(5):884-886
OBJECTIVETo evaluate the performance of BNII auto-analyzer system in detecting C3 and C4.
METHODSCLSI protocols (EP15-A, EP6-A, EP9-A2) and other relevant literatures were use to or evaluate the precision, accuracy, linearity of C3 and C4 detection by the auto-analyzer system, and the results were compared with the recognized standards.
RESULTSThe relative bias of C3 and C4 was less than one third of the CLIA'88 standard and the precision met the clinical requirement. The results tested by DADE BNII system were not compatible with those by Roche Modular System. C3 showed good linearity in the tests (R2>0.975, P<0.05) with a linearity range of 0.18-5.1 g/L. The linearity of C4 was not available because of lack of high-level samples.
CONCLUSIONThe performances of DADE BNII System basically meet the recognized standards in clinical detection of C3 and C4, but the method comparison needs further validation.
Autoanalysis ; methods ; Blood Chemical Analysis ; instrumentation ; methods ; Complement C3 ; analysis ; Complement C4 ; analysis ; Humans ; Nephelometry and Turbidimetry ; instrumentation ; methods ; Proteins ; analysis ; Sensitivity and Specificity
9.Method performance verification of the clinical chemiluminescence immunoassay
Xiu-Ming ZHANG ; Jun-Hua ZHUANG ; Song-Bai ZHENG ; Jian-Hua XU ; Ji MA ; Lei SUN ; Lian-Ying LIN ; Pei-Feng KE ; Wei-Xiong LIANG
Chinese Journal of Laboratory Medicine 2003;0(11):-
Objective To establish a method performance verification project and experimental method for the clinical chemiluminescence immunoassay.Methods Referring to CLSI evaluation protocols and pertinent literature,and by combining our actual works,we designed a verification procedure and experimental method.By Using these above,the precision,accuracy,analytical sensitivity,analytical measurement range,clinical reportable range and biotic interval of AFP on the Bayer Centaur 240 chemiluminescence immunoassay system were verificated.Results would be compared with the declaration of the manufacturer or desirable specifications derived from biologic variation.Results The results showed that the between-day inaccuracy on AFP levels at 77.4 ng/ml and 168.0 ng/ml was 5.70% and 4.84% respectively,these were consistent with manufacturer's inaccuracy claimed.The relative bias between the results measured for calibrator at four levels and target value was less 5.0%,and the relative bias between the results measured for EQA control sample at five levels and target value was-3.4% to 11.9%.Lower limit of detection was 1.04 ng/ml,lower slightly manufacturer's analytical sensitivity claimed.Biologic limit of detection was 2.65 ng/ml-3.53 ng/ml,functional sensitivity was 3.53 ng/ml.Analytical measurement range was 3.53-912.00 ng/ml,within manufacturer's liner range claimed.Clinical reportable range was 3.53-182 400.00 ng/ml.Reference interval was 0.6-7.7 ng/ml,within manufacturer' s claimed.Conclusions The main performances of the detection system are accorded with the declaration of the manufacturer.The performance verification procedure and experimental method of our research ars simple and practical,which has important significations for building medical laboratory and laboratory accreditation, improving quality of the chemiluminescence immunoassay.
10.Replantation of the amputated mass of fingers
Jia-Chuan ZHUANG ; Zhen-Wei ZHANG ; Jian-Wen LIAO ; Le-Feng CHEN ; Guo-Rong CHEN ; Shao-Xiao YU ; Zhu-Ming GUAN
Chinese Journal of Microsurgery 2000;0(04):-
Objective To explore the replantation methods of the amputated tisue mass of fingers. Methods Fifteen cases were replanted using the physiological blood circulation replantation and the no physi- ological blood circulation replantation.Results All eleven cases survived with the physiological blood circu- lation replantation,one case failure with no physiological blood circulation replantation.Postoperative follow up ranged from six months to two years,with an average of fifteen months,the function and appearance were satis- factory.According to Hand Surgery of Chinese Medical Association' s functional evaluation in digital replanta- tion,eleven cases were excellent and two cases were good,the excellent and good rates were up to 86.7%. Conclusion For the amputated tissue mass of fingers,the physiological blood circulation replantation is the best choose.