2.The value of color Doppler ultrasounograpy in the diagnosis of breast mass:a report of 600 cases
Jialing DU ; Heqing SUN ; Fei CHEN ; Hailong PAN
Chinese Journal of General Surgery 1994;0(05):-
Objective To exploration the value of color Doppler ultrasounographhy(CDU) in the diagnosis of breast mass. Methods The clinical data of 600 cases of breast tumor treated in our hospital in recent 3 years were retrospectively analysed, all patients were examined with CDU before operation. Results CDU found breast small tumor in 163 cases(27.2%) which couldn’t detected by hands, found multiple masses in 307 cases(51.2%);and suspected malignancy in 75 cases,of the 75 cases,malignancies were comfirmed by pathological examination in 72 cases(96.0%).Conclusions CDU can find small breast mass which can not be detected by hands,and can determin the mass is a tumor or not.CDU can also find early stage of breast cancer.CDU is non-traumatic,rasily to be perfomed and repeated.CDU can improve the preoperative diagnosis rate of breast mass.
3.AN INVESTIGATION ON NUTRITION AND DEVELOPMENT AND DISEASE OF CHILDREN UNDER AGE 2 IN SHANGHAI FACTORY NURSERIES
Peiyun YANG ; Meifang JU ; Jialing LING ; Lijuan YUAN ; Jue SUN ; Chengxin QIU ; Xiaofen NIU ; Jingyi TAN ; Jinwu CHEN ; Yunmin PAN
Acta Nutrimenta Sinica 1956;0(03):-
This paper is a follow-up study of 329 children in factory-run nurseries in urban Shanghai. The investigation lasted for a period of one year for each index-child, focusing on the conditions of nutrition, development and diseases of the children of various ages.Comparison between nutritionl findings and RDA of China disclosed that calorie intake of most of the index-child groups were 80-85% of RDA, the only exception being the 6-12 months group where the average calorie intake showed 90%. Protein intake of all groups was over 80% of RDA. Fe intake was lower than RDA, except for 18-month-old and over.Weight and height of the children were compared with the anthropo-metric data established in 1985 (1985 data) for Shanghai children under six years of age. It was found that the average weight and height appeared differently according to their age. Average weight of children under one year old was slightly higher than 1985 data, while average height was lower than 1985 data once the children reached 10 months old. Average weight, however, became lower than the 1985 data after the children were two years old. Over 60% of the index between 6-18 months old suffered from anemia (IDA).Accordingly, it is requested that calorie and iron intake should be supplemented.
4.Application value of CT extracellular volume fraction in diagnosis and classification of acute pancreatitis
Liwen WANG ; Fusheng OUYANG ; Xiyi HUANG ; Jialing PAN ; Ming CHEN ; Lanni ZHOU ; Qiugen HU ; Baoliang GUO
Journal of Practical Radiology 2024;40(7):1091-1095
Objective To investigate the application value of extracellular volume fraction(ECV)obtained from enhanced CT in diagnosis and classification of acute pancreatitis.Methods The clinical data from patients with acute pancreatitis(acute pancreatitis group)and normal controls(control group)underwent enhanced CT were analyzed retrospectively.The CT values of pancreas and abdominal aorta in the same sclice on precontrast and equilibrium-phase images were measured,and then pancreatic ECV was calcu-lated.The measured parameters were compared between the groups of control and acute pancreatitis,and subgroups of non-severe and severe pancreatitis.The logistic regression analysis was used to identify the risk factors for acute pancreatitis and severe pancrea-titis,and the receiver operating characteristic(ROC)curve was used to analyze the diagnostic efficiency in diagnosis and classifica-tion of acute pancreatitis.Results The pancreatic CT value and ECV were independent risk factors for acute pancreatitis(P<0.05),and the ECV was an independent risk factor for severe pancreatitis(P<0.05).The area under the curve(AUC)of ECV was higher in acute pancreatitis group(0.81)and severe pancreatitis subgroup(0.68).Conclusion As a quantitative parameter,the ECV obtained from enhanced CT has higher clinical application value and higher popularity in the diagnosis and classification of acute pancreatitis.
5.The quantification of Z-score of the color flow widths of atrioventricular valves in the fetuses with dilation of the coronary sinus
Jianfei ZHU ; Bowen ZHAO ; Xiuzhi WEI ; Jialing LUO ; Mei PAN ; Bei WANG ; Xiaohui PENG
Chinese Journal of Ultrasonography 2019;28(1):42-48
Objective To calculate Z-score for mitral and tricuspid color blood flow widths in normal fetuses and fetuses with dilated coronary sinuses ( CS ) using fetal echocardiography ,and explore the application value of Z-score of the color flow widths of atrioventricular valves in normal fetuses and fetuses with dilated CS . Methods Two hundred and thirty-eight normal fetuses (control group) with a gestational age of 16 to 38 weeks were studied by color Doppler echocardiography . Gestational age ( GA ) ,biparietal diameter (BPD) ,femoral length (FL) ,aortic inner diameter (AOd) ,pulmonary artery diameter (PAd) ,and heart area ( HA) were measured as independent variables ,and mitral and tricuspid valve color flow widths were measured as the dependent variables . Z-score models were established by regression analysis . Thirty fetuses with dilated CS (dilated CS group) from 22 to 33 weeks'gestation were involved . The Z-score of the CS fetus was calculated based on the established Z-score models and were compared with those of the normal fetuses . Results The independent sample t-test showed that there were no significant differences in the Z-scores of the blood flow width of the fetal mitral and tricuspid valves between dilated CS group and control group ( P >0 .05) . Conclusions The simple dilated CS does not affect the mitral valve diastolic blood flow ,so there is no significant effect on the filling of left ventricular blood flow .
6.Study on the characteristics of mitral annular displacement in middle and late pregnancy fetuses based on speckle tracking imaging
Mei PAN ; Xianfeng GUO ; Bowen ZHAO ; Yankai MAO ; Jialing LUO
Chinese Journal of Ultrasonography 2019;28(10):869-873
Objective To assess the longitudinal mitral annular plane systolic excursion ( M APSE) of different directions in normal fetuses during mid‐late pregnancy based on two‐dimensional speckle tracking imaging ( ST I) . Methods Seventy‐six normal fetuses during middle and late pregnancy were selected at 26-32 weeks of gestation . T he peak M APSE was measured by free angle M‐mode echocardiography ( FAM ) perpendicular to the lateral annulus in the mitral annular plane . The time‐displacement curves of interventricular septal mitral annulus in three different directions including points A ,B and C through transverse level of apex were recorded by STI . T he peak M APSE of interventricular septal mitral annulus ( SEPT‐M APSE‐A ,SEPT‐M APSE‐B ,SEPT‐M APSE‐C) in three different directions including points A ,B and C and the time to peak ( T T P :SEPT‐T T P‐A ,SEPT‐T T P‐B ,SEPT‐T T P‐C) were recorded respectively . T he time‐displacement curves of lateral mitral annulus in three different directions including points A ,B and C through transverse level of apex were recorded by STI . T he peak M APSE of lateral mitral annulus ( LAT‐M APSE‐A ,LAT‐MAPSE‐B ,LAT‐MAPSE‐C) in three different directions including points A ,B and C ,the time to peak( LA T‐T T P‐A ,LA T‐T T P‐B ,LA T‐T T P‐C) were recorded respectively . Finally ,the data were analyzed statistically . Results T he peak M APSE of the lateral mitral annulus in 3 different directions including points A ,B and C[ LA T‐M APSE‐A ( 3 .62 ± 1 .01) mm ,LA T‐M APSE‐B ( 3 .95 ± 1 .04) mm ,LAT‐M APSE‐C ( 4 .45 ± 1 .05) mm ] were greater than those of the interventricular septum mitral annulus[ SEPT‐MAPSE‐A (3 .41 ± 0 .63)mm ,SEPT‐MAPSE‐B (3 .07 ± 0 .50) mm ,SEPT‐MAPSE‐C (2 .82 ± 0 .51) mm] . LAT‐M APSE‐C and SEPT‐M APSE‐A were the largest longitudinal excursions of mitral annulus . T he differences were statistically significant in points B and C ( P <0 .05) . T here was no significant difference in point A ( P >0 .05) . LA T‐M APSE‐C was less than FAM‐M APSE [ ( 6 .06 ± 1 .35 ) mm ] . T here was a significant difference between them ( P <0 .05 ) . Strong correlation was found between them ( r =0 .896 , P<0 .05) . T here were no significant differences in the time to peak of interventricular septal mitral annulus [ SEPT‐T T P‐A ( 0 .210 ± 0 .008 ) s ,SEPT‐T T P‐B ( 0 .213 ± 0 .008 ) s ,SEPT‐T T P‐C ( 0 .210 ± 0 .005 ) s] in directions including points A ,B ,C ( P> 0 .05 ) . T here were no significant differences in time to peak of lateral mitral annulus [ LAT‐T T P‐A ( 0 .210 ± 0 .008 ) s , LAT‐T T P‐B ( 0 .213 ± 0 .006 ) s , LAT‐T T P‐C ( 0 .210 ± 0 .007) s] in directions inclucling points A ,B ,C ( P >0 .05) . Conclusions Longitudinal systolic motion of fetal left ventricular wall during mid‐late pregnancy has good synchronization . Longitudinal motion of fetal mitral annulus is a comprehensive movement of multiple directions and different degrees of displacement ,with the movement perpendicular to the annulus as the maximum displacement direction . T he displacement parameters of mitral annulus measured by ST I can reflect the left ventricular longitudinal systolic function and have clinical application value in evaluating the left ventricular longitudinal systolic function of fetuses .
7. Study on the characteristics of mitral annular displacement in middle and late pregnancy fetuses based on speckle tracking imaging
Mei PAN ; Xianfeng GUO ; Bowen ZHAO ; Yankai MAO ; Jialing LUO
Chinese Journal of Ultrasonography 2019;28(10):869-873
Objective:
To assess the longitudinal mitral annular plane systolic excursion (MAPSE) of different directions in normal fetuses during mid-late pregnancy based on two-dimensional speckle tracking imaging (STI).
Methods:
Seventy-six normal fetuses during middle and late pregnancy were selected at 26-32 weeks of gestation. The peak MAPSE was measured by free angle M-mode echocardiography (FAM) perpendicular to the lateral annulus in the mitral annular plane. The time-displacement curves of interventricular septal mitral annulus in three different directions including points A, B and C through transverse level of apex were recorded by STI. The peak MAPSE of interventricular septal mitral annulus (SEPT-MAPSE-A, SEPT-MAPSE-B, SEPT-MAPSE-C) in three different directions including points A, B and C and the time to peak (TTP: SEPT-TTP-A, SEPT-TTP-B, SEPT-TTP-C) were recorded respectively. The time-displacement curves of lateral mitral annulus in three different directions including points A, B and C through transverse level of apex were recorded by STI. The peak MAPSE of lateral mitral annulus (LAT-MAPSE-A, LAT-MAPSE-B, LAT-MAPSE-C) in three different directions including points A, B and C, the time to peak(LAT-TTP-A, LAT-TTP-B, LAT-TTP-C) were recorded respectively. Finally, the data were analyzed statistically.
Results:
The peak MAPSE of the lateral mitral annulus in 3 different directions including points A, B and C[LAT-MAPSE-A (3.62±1.01)mm, LAT-MAPSE-B (3.95±1.04)mm, LAT-MAPSE-C (4.45±1.05)mm] were greater than those of the interventricular septum mitral annulus[SEPT-MAPSE-A (3.41±0.63)mm, SEPT-MAPSE-B (3.07±0.50)mm, SEPT-MAPSE-C (2.82±0.51)mm]. LAT-MAPSE-C and SEPT-MAPSE-A were the largest longitudinal excursions of mitral annulus. The differences were statistically significant in points B and C (