1.Application of genetic algorithm in blending technology for extractions of Cortex Fraxini.
Ming YANG ; Yinmin ZHOU ; Jialei CHEN ; Minying YU ; Xiufeng SHI ; Xijun GU
China Journal of Chinese Materia Medica 2009;34(20):2594-2598
OBJECTIVETo explore the feasibility of genetic algorithm (GA) on multiple objective blending technology for extractions of Cortex Fraxini.
METHODAccording to that the optimization objective was the combination of fingerprint similarity and the root-mean-square error of multiple key constituents, a new multiple objective optimization model of 10 batches extractions of Cortex Fraxini was built. The blending coefficient was obtained by genetic algorithm. The quality of 10 batches extractions of Cortex Fraxini that after blending was evaluated with the finger print similarity and root-mean-square error as indexes.
RESULTThe quality of 10 batches extractions of Cortex Fraxini that after blending was well improved. Comparing with the fingerprint of the control sample, the similarity was up, but the degree of variation is down. The relative deviation of the key constituents was less than 10%.
CONCLUSIONIt is proved that genetic algorithm works well on multiple objective blending technology for extractions of Cortex Fraxini. This method can be a reference to control the quality of extractions of Cortex Fraxini. Genetic algorithm in blending technology for extractions of Chinese medicines is advisable.
Algorithms ; Chromatography, High Pressure Liquid ; Drugs, Chinese Herbal ; analysis ; Medicine, Chinese Traditional ; standards ; Plants, Medicinal ; chemistry ; genetics ; Quality Control
2.Performance evaluation of automated magnetic beads extraction method for the measurement of catecholamine metabolites analyzed by liquid chromatography tandem mass spectrometry
Songlin YU ; Xiaoli MA ; Jialei YU ; Ming LI ; Yacong GUO ; Zhendong LIU ; Yutong ZOU ; Danchen WANG ; Wei LUO ; Ling QIU
Chinese Journal of Laboratory Medicine 2022;45(3):268-274
Objective:To evaluate the performance of magnetic beads extraction method (MGE) for the measurement of catecholamine metabolites by liquid chromatography tandem mass spectrometry.Methods:This is a methodological evaluation study. The linearity, limit of quantitation, recovery, precision, and matrix effect of catecholamine metabolites 3-methoxyepinephrine (MN), 3-methoxynorepinephrine (NMN) and 3-methoxytyramine (3-MT) extracted by MGE method were evaluated according to CLSI C62-A. Consensus of method development and validation of liquid chromatography-tandem mass spectrometry in clinical laboratories and other guidelines, 132 clinical residual plasma samples were collected and extracted by automated MGE and traditional solid phase extraction (SPE) method to compare the harmonization of the two extraction methods.Results:The linearity of MN, NMN and 3-MT extracted by automated MGE was>0.99, and the LOQ for MN, NMN and 3-MT were 0.033 5 nmol/L, 0.054 7 nmol/L and 0.011 0 nmol/L, respectively. The repeatability of MN, NMN and 3-MT were 1.3%-5.1%, 2.2%-5.6% and 1.7%-7.1%, respectively. The total imprecision in the laboratory were 1.5%-8.2%, 2.2%-7.7%, 2.1%-11.2%. Although the absolute recovery is low, the average relative recoveries of MN, NMN and 3-MT were 91.5%-108.5%, 92.0%-108.6%, and 89.3%-104.1%, respectively, and the percentage deviation from the expected concentration was within 15%. After isotope internal standard correction, the relative matrix effect is close to 100%, which can compensate for the potential matrix effect. The results of MGE and SPE of MN, NMN and 3-MT showeda good correlation (correlation coefficient r>0.99). The average relative deviations of MN, NMN and 3-MT were 0.2%, -1.4% and 1.0%, respectively. Conclusion:The automatic MGE method hasa good performance in extracting catecholamine metabolites, and is expected to be used in high-throughput analysis of samples in clinical in the future.
3.Case report of pseudoelevated serum testosterone in women and literature review
Wei LUO ; Li′an HOU ; Songlin YU ; Ying ZHANG ; Jialei YU ; Yicong YIN ; Li LIU ; Xiaoyue LIANG ; Xin LIU ; Yujun SU ; Shaowei XIE ; Ling QIU ; Liangyu XIA
Chinese Journal of Laboratory Medicine 2022;45(12):1275-1278
Objective:The characteristics of women with false elevated testosterone were analyze and the literature was reviewed to provide reference for clinical laboratory identification of false elevated testosterone.Methods:The characteristics of three patients with false elevated testosterone in Peking Union Medical College Hospital were analyzed retrospectively, and the results of different detection platforms and methods for the determination of testosterone levels were compared. International and domestic literatures related to false elevation of testosterone and detection methods of testosterone were searched for a comprehensive analysis from PUBMED and CNKI.Results:The levels of testosterone in 3 female patients were elevated by immunoassay and normal by mass spectrometry. They were excluded from the diagnosis of hyperandrogenemia. A total of 38 literatures related to testosterone detection were retrieved, of which 9 case reports of pseudohyperandrogenemia, among which 12 cases of pseudohyperandrogenemia were reported in 2 domestic literatures in 2021. All cases were confirmed by liquid chromatography-tandem mass spectrometry (LC-MS/MS). Previous studies have clearly indicated that the result of routine immunoassay in clinical laboratory for the determination of female testosterone have poor correlation with the results of LC-MS/MS, with varying degrees of deviation.Conclusions:Immunoassay tests for female testosterone is susceptible to interference and lead to elevated false results. It is suggested that clinical laboratories evaluate the detection methods used and establish a identification program, and confirm samples with suspected pseudoelevated testosterone elevation using other immune platforms or LC-MS/MS.
4.Optimization of formulation and preparation technology of Neuritic acid oral emulsion
Wenjing CHEN ; Jialei FU ; Dandan SUN ; Beibei YU ; Lisong SHENG ; Xuesheng YAN
China Pharmacy 2022;33(4):458-464
OBJECTIVE To prepare Neuritic acid oral emulsion ,to optimize its formulation and preparation technology ,and to investigate its stability. METHODS Neuritic acid oral emulsion was prepared by mechanical method. On the basis of single factor experiment ,the appearance ,centrifugal stability ,centrifugal stability constant (Ke)and particle size of the emulsion as indexes,the formulation was optimized by orthogonal design ,taking the dosage of oleic acid ,octylphenol polyoxyethylene ether-10 and propylene glycol as factors ,the preparation technology was optimized by taking emulsification temperature ,shear time,pressure of high-pressure homogenization and cycle times of high-pressure homogenization as factors. The content of neuritic acid was determined by high performance liquid chromatography. The stability of Neuritic acid oral emulsion was investigated by high temperature test ,accelerated test and long-term test. RESULTS The optimal formulation and preparation technology were as follows:neuritic acid of 1 g,oleic acid of 5% ,octylphenol polyoxyethylene ether- 10 of 4% ,propylene glycol of 2% , emulsification temperature of 60 ℃ ,shear time of 2 min,homogenization pressure of 40 MPa and cycle times of twice. After three experiments ,the average particle size of Neuritic acid oral emulsion was 158.05 nm(RSD=1.58%,n=3),the average Ke was 0.39(RSD=1.49%,n=3),and the appearance was uniform milky white ,there was no stratification. The results of high temperature test showed that Neuritic acid oral emulsion was prone to stratification in high temperature environment ,and the content of neuritic acid increased. The results of accelerated test and long-term test showed that there was no significant change in the appearance or the content of neuritic acid when Neuritic acid oral emulsion was placed at room temperature for 6 months. CONCLUSIONS The formulation and preparation technology are stable and feasible ,and can be used for the preparation of Neuritic acid oral emulsion. Neuritic acid oral emulsion should not be placed in high temperature environment. It has good stability at room temperature for 6 months.
5.miR-20a regulates pressure overload-induced cardiac hypertrophy
Teng SUN ; Yu HAN ; Shuang WANG ; Jialei LI ; Jimin CAO
Chinese Journal of Tissue Engineering Research 2024;28(7):1021-1028
BACKGROUND:Cardiac hypertrophy is an adaptive response of the heart to physiological and pathological stimuli such as pressure overload.It is of compensatory significance in the early stage,but if the stimulation continues,it can cause cardiomyopathy leading to heart failure.MicroRNAs are involved in the regulation of cardiac hypertrophy.However,the role of miR-20a in pressure overload-induced cardiac hypertrophy has not been reported. OBJECTIVE:To investigate the role of miR-20a in pressure overload-induced cardiac hypertrophy and the underlying mechanisms. METHODS:Transverse aortic constriction was used to induce cardiac hypertrophy in vivo and angiotensin Ⅱ was used to induce H9c2 cell models of cardiac hypertrophy in vitro.MiR-20a was overexpressed in vivo by intramyocardial injection of miR-20a overexpressing adenovirus and in vitro by transfecting miR-20a mimic into H9c2 cells.Cardiac hypertrophy was assessed by measuring heart weight/body weight ratio,cell surface area,and myocardial fibrosis.The expression levels of atrial natriuretic peptide,brain natriuretic peptide,β-myosin heavy chain and miR-20a were detected by real-time fluorescence quantitative PCR.Mitochondrial fission was detected by MitoTracker.The downstream target genes of miR-20a were predicted by RNAhybrid software. RESULTS AND CONCLUSION:(1)The expression level of miR-20a was significantly decreased in both hypertrophic cardiomyocytes and hearts(P<0.05).(2)At the animal level,overexpression of miR-20a significantly inhibited transverse aortic constriction-induced cardiac hypertrophy,including decreasing the upregulated expression level of hypertrophic marker genes(P<0.05),reduced the enlarged heart volume,reducing the increased heart weight/body weight ratio(P<0.01),reducing the increased myocardial cross-sectional area(P<0.05),and attenuating fibrosis(P<0.01).(3)At the cellular level,overexpression of miR-20a significantly inhibited angiotensin Ⅱ-induced cardiomyocyte hypertrophy,including decreasing the upregulated expression levels of atrial natriuretic peptide(P<0.05),brain natriuretic peptide(P<0.01)and β-myosin heavy chain(P<0.05),reducing the increased protein/DNA ratio(P<0.01),and suppressing the increased cell surface area(P<0.05).(4)Overexpression of miR-20a significantly inhibited angiotensin Ⅱ-induced mitochondrial fission(P<0.05).(5)The results of RNAhybrid software analysis showed that miR-20a and the mRNA 3'untranslated region of cAMP-dependent protein kinase inhibitor alpha were well complementary and the predicted binding sites were highly conserved.(6)In conclusion,miR-20a is significantly down-regulated in pressure overload-induced cardiac hypertrophy.Overexpression of miR-20a inhibits cardiac hypertrophy at both the cellular level and animal level and attenuates angiotensin Ⅱ-induced mitochondrial fission.
6.Comparison of different immobilization methods in breast cancer radiotherapy after breast-conserving surgery
Xuechen LUO ; Jialei YU ; Lin ZHU ; Xuenan LI ; Gaofeng LI ; Xia XIU ; Qiuzi ZHONG ; Yonggang XU
Chinese Journal of Radiological Medicine and Protection 2022;42(7):522-526
Objective:To compare and analyze the differences in the setup accuracy of different immobilization method in breast cancer radiotherapy after breast-conserving surgery.Methods:A retrospective study was conducted on 60 patients who received radiotherapy after breast-conserving surgery from January to August, 2021. These patients were divided into two groups. One group consisted of 30 cases who were immobilized using a modified body thermoplastic membrane combined with a multifunction body board during the breast cancer radiotherapy and was called the modified body thermoplastic membrane group. The other group comprised 30 cases immobilized using a vacuum cushion during breast cancer radiotherapy and was referred to as the vacuum cushion group. The setup errors, 3D vector errors, the proportion of errors of > 5 mm, and the dosimetric differences in the planning target volume (PTV) and the clinical target volume (CTV) before and after simulated treatment bed moving (including the PTV_ V100, PTV_ V95, and CTV_ V95 before simulated treatment bed moving and the PTV_ V100 S, PTV_ V95 S, and CTV_ V95 S after simulated treatment bed moving) were compared between two groups. Moreover, for the modified body thermoplastic membrane group, the changes in the average setup errors at different radiotherapy stages were also analyzed. Results:A total of 369 cone-beam CT scans were conducted for 60 patients, including 195 CT scans for the modified body thermoplastic membrane group and 174 CT scans for the vacuum cushion group. The setup errors in the x, y, and z directions (right-left, anterior-posterior, and superior-inferior, respectively) of the modified body thermoplastic membrane group were (2.59±1.98) mm, (2.38±2.04) mm, and (1.45±1.16) mm, respectively, while those of the other group were (2.24±1.63) mm, (2.78±2.17) mm, and (2.70±1.88) mm, respectively. The 3D vector errors of both groups were (4.32±2.28) mm and (5.13±2.14) mm, respectively. Therefore, the setup error in direction z and the 3D vector error of the modified body thermoplastic membrane group were less than those of the vacuum cushion group ( t = -7.77, -3.41, P<0.05). Moreover, the proportion of setup errors of > 5 mm in the x direction of the vacuum cushion group was lower than that of the modified body thermoplastic membrane group ( χ2 = 7.13, P<0.05), while such proportion in the z direction of the modified body thermoplastic membrane group was lower than that of the vacuum cushion group ( χ2= 5.90, P<0.05). After the simulated treatment bed moving, the PTV_ V100 S of the modified body thermoplastic membrane group was better than that of the vacuum cushion group ( t = 2.47, P < 0.05). Furthermore, for the modified body thermoplastic membrane group, the setup errors in the x direction in the first week were higher than those in the 2-3 weeks and 4-5 weeks ( P<0.05). Conclusions:The modified body thermoplastic membrane combined with a multifunction body board yield better immobilization effects than a vacuum cushion. However, it produces high setup errors in the x direction in the first week of the radiotherapy, to which special attention should be paid.
7.A broadly neutralizing human monoclonal antibody against the hemagglutinin of avian influenza virus H7N9.
Jingxin LI ; Li ZHANG ; Linlin BAO ; Yuxiao WANG ; Lin QIU ; Jialei HU ; Rong TANG ; Huiyan YU ; Jun SHAN ; Yan LI ; Chuan QIN ; Fengcai ZHU
Chinese Medical Journal 2022;135(7):799-805
BACKGROUND:
The new emerging avian influenza A H7N9 virus, causing severe human infection with a mortality rate of around 41%. This study aims to provide a novel treatment option for the prevention and control of H7N9.
METHODS:
H7 hemagglutinin (HA)-specific B cells were isolated from peripheral blood plasma cells of the patients previously infected by H7N9 in Jiangsu Province, China. The human monoclonal antibodies (mAbs) were generated by amplification and cloning of these HA-specific B cells. First, all human mAbs were screened for binding activity by enzyme-linked immunosorbent assay. Then, those mAbs, exhibiting potent affinity to recognize H7 HAs were further evaluated by hemagglutination-inhibiting (HAI) and microneutralization in vitro assays. Finally, the lead mAb candidate was selected and tested against the lethal challenge of the H7N9 virus using murine models.
RESULTS:
The mAb 6-137 was able to recognize a panel of H7 HAs with high affinity but not HA of other subtypes, including H1N1 and H3N2. The mAb 6-137 can efficiently inhibit the HA activity in the inactivated H7N9 virus and neutralize 100 tissue culture infectious dose 50 (TCID50) of H7N9 virus (influenza A/Nanjing/1/2013) in vitro, with neutralizing activity as low as 78 ng/mL. In addition, the mAb 6-137 protected the mice against the lethal challenge of H7N9 prophylactically and therapeutically.
CONCLUSION
The mAb 6-137 could be an effective antibody as a prophylactic or therapeutic biological treatment for the H7N9 exposure or infection.
Animals
;
Antibodies, Monoclonal/therapeutic use*
;
Antibodies, Neutralizing/therapeutic use*
;
Antibodies, Viral
;
Hemagglutinins
;
Humans
;
Influenza A Virus, H1N1 Subtype
;
Influenza A Virus, H3N2 Subtype
;
Influenza A Virus, H7N9 Subtype
;
Influenza Vaccines
;
Influenza in Birds
;
Influenza, Human/prevention & control*
;
Mice