1.Influence of esmolol on plasma NT-proBNP, heart-type fatty acid binding protein and cardiac function in acute cerebral infarction patients with myocardial enzyme abnormalities
Hongyan WANG ; Zhigang LUO ; Jiaheng XU ; Xiaobin LI ; Lili XIE ; Yanlan LI
Chinese Journal of Biochemical Pharmaceutics 2015;(3):138-140
Objective To analyse the influence of esmolol on plasma N terminal pro-brain natriuretic peptide ( NT-proBNP) , heart-type fatty acid binding protein ( H-FABP) and cardiac function in acute cerebral infarction patients with myocardial enzyme abnormalities.Methods 86 acute cerebral infarction patients with myocardial enzyme abnormalities from September 2010 to July 2014 in our hospital were selected and divided into experimental group and control group randomly (43 cases in each group).All patients were accompanied by myocardial enzyme abnormalities, patients in control group were given basic treatment, while patients in experimental group were given esmolol hydrochloride intravenous injection on the basis of control group.Plasma NT-proBNP, H-FABP levels and cardiac function were analyzed in two groups.Results Myocardial enzyme levels had no significant difference between two groups on admission.Plasma NT-proBNP levels also had no statistical differences after admission hospital of 6 h, 15 h and 3 d , and experimental group was significantly lower than control group ( P<0.05 ) after admission hospital of 5 day and 7 days.H-FABP levels had no statistical differences after admission hospital of 6 h, 15 h, and the experimental group was significantly lower than the control group (P<0.05) after admission hospital of 3, 5, 7 days.Cardiac function with Killip classification showed no significant difference when on admission and after admission hospital of 3 days, and the experimental group was significantly better than control group (P<0.05) after admission hospital of 5, 7 days.Conclusion Acute cerebral infarction patients with myocardial enzyme abnormalities given esmolol on the basic treatments significantly reduce NT-proBNP and HAFBP levels, and improve cardiac function, which is worthy of promotion in clinical applications.
2.Analyzing the monitoring results of occupational hazards in the workplace of key industries in Guangdong Province, 2020-2023
Weifeng RONG ; Zuofei XIE ; Jiaheng HE ; Jing YUAN ; Jiawen HU ; Ruibo MENG ; Banghua WU
China Occupational Medicine 2024;51(1):54-59
ObjectiveTo understand the monitoring result of occupational hazard in the workplace of key industries in Guangdong Province from 2020 to 2023. Methods The data of occupational hazards in the workplace of 20 key industries in Guangdong Province from 2020 to 2023 were collected from the “Workplace Occupational Hazard Monitoring System” of the Chinese Disease Prevention and Control System subsystem. The monitoring result of occupational hazard factors, occupational health training, occupational health examination, occupational protection, detection of occupational hazardous agents such as dust, chemical substances and noise were analyzed. Results A total of 13 058 enterprises from key industries were recruited as the monitoring subjects in Guangdong Province. There were 290 large-, 1 342 medium-, 7 635 small-, and 3 791 micro-enterprises, with small and micro-enterprises accounting for 58.5% and 29.0% of the total, respectively. A total of 7 542 enterprises exceeded the national standard in the detection of occupational hazards, with a rate of 57.8%. A total of 1 942 517 workers from 13 058 enterprises were recruited, with 835 567 workers were exposed to occupational hazards, with a rate of 43.0%. The rate of occupational health training for enterprise leaders, occupational health management personnel, and workers was 71.9%, 73.8%, and 86.5%, respectively. The abnormal rate of occupational health examinations for workers exposed to noise, dust, and chemical agents was 2.0%, 0.6%, and 1.0%, respectively. The distribution rate of dust masks, anti-poisoning masks or face masks, and noise prevention earplugs or earmuffs was 83.3%, 71.3%, and 77.8%, respectively. The rate of installation of dust prevention facilities, anti-poisoning facilities, and noise prevention facilities was 85.6%, 81.2%, and 50.1%, respectively. The rate of exceeded the national standard of dust, noise in the worksites/types and workplaces showed a decreasing trend year by year (all P<0.01), while the rate of exceeded the national standard of chemical agents in worksites/types and workplaces showed an increasing trend year by year in various occupational hazards (all P<0.01). Conclusion Occupational hazards in the workplace of key industries in Guangdong Province are relatively common. The proportion of workers exposed to occupational hazards is relatively high. It is necessary to further improve the use of noise prevention facilities and protective equipment, strengthen occupational health training for enterprises throughout the province and regularly monitor occupational hazards to reduce the risk of occupational diseases.
3.Determination of two isomers of tetrachloroethane in urine by liquid-liquid extraction-gas chromatography
Fan WU ; Jiaheng HE ; Jing YUAN ; Ruibo MENG ; Weimin XIE ; Banghua WU ; Weifeng RONG
China Occupational Medicine 2024;51(1):85-89
ObjectiveTo establish a method for the determination of 1,1,1,2-tetrachloroethane (TeCA) and 1,1,2,2-TeCA in human urine using liquid-liquid extraction-gas chromatography. Methods The 5.0 mL urine sample was mixed with 2.0 g anhydrous sodium sulfate and 5.0 mL ethyl acetate, then vortexed mixing. The 1.0 mL extraction was separated by 100% dimethylpolysiloxane capillary gas chromatography column, detected by flame ionization detector, and quantified by an external standard method. Results The linear ranges of 1,1,1,2-TeCA and 1,1,2,2-TeCA were 0.250-50.750 mg/L, with both correlation coefficients of >0.999 9. The detection limit of 1,1,1,2-TeCA in urine was 0.020 mg/L, and the lower limit of quantification was 0.060 mg/L. The average recovery was 88.02%-101.32%, and the within-run and between-run relative standard deviations (RSDs) were 0.11%-0.47% and 0.39%-1.09%, respectively. The detection limit of 1,1,2,2-TeCA in urine was 0.050 mg/L, and the lower limit of quantification was 0.150 mg/L. The average recovery was 93.42%-101.32%, and the within-run and between-run RSDs were 0.28%-1.04% and 0.50%-1.03%, respectively. Both the 1,1,1,2-TeCA and 1,1,2,2-TeCA cannot be stored at room temperature. The 1,1,2,2-TeCA can be stored at 4 ℃ for at least three days. At -20 ℃, the 1,1,1,2-TeCA can only be stored for one day, while 1,1,2,2-TeCA can be stored for at least five days. Conclusion This method has high sensitivity, good specificity, simple sample pretreatment, and more intuitive and reliable results. It can be used to determine the level of 1,1,1,2-TeCA and 1,1,2,2-TeCA in urine of occupational population.
4.Cognitive function in patients with early onset and adult onset schizophrenia
Bingjie HUANG ; Jiaheng XIE ; Chengcheng PU ; Huining GUO ; Lei YANG ; Xue HAN ; Zhang CHENG ; Yanbo YUAN ; Jingping ZHAO ; Chuanyue WANG ; Zheng LU ; Fude YANG ; Hong DENG ; Chuan SHI ; Xin YU
Chinese Mental Health Journal 2019;33(3):161-166
Objective:To explore the characteristics of cognitive function in patients with early onset and adult onset schizophrenia.Methods:In this cross-sectional study, 546 patients with schizophrenia who met the Diagnostic and Statistical Manual of Mental Disorders, Fourth Edition (DSM-Ⅳ) were selected.Among them, 62 cases were defined as early onset schizophrenia (EOS, age of onset<18 years) and 175 patients were defined as adult onset schizophrenia (AOS, age of onset≥25 years).Patients underwent clinical assessments with the Positive and Negative Symptom Scale (PANSS) and the Personal and Social Performance Scale (PSP), and comprehensive neuropsychological assessments.Results:The EOS patients got lower scores in motor function-PEGDOM T score [ (26±12) vs. (30±11), P<0.01], working memory-average T score of PASAT and WMSSP[ (34±12) vs. (38±10), P<0.05]and executive function (inhibition) -Stroop T score [ (35±12) vs. (39±10), P<0.05]than AOS patients.No differences were fund in processing speed, verbal memory and learning, visual memory and learning (Ps>0.05) between the two groups.Conclusion:It suggests that the EOS patients have worse motor function, working memory and inhibition.
5.Determination of two isomers of tetrachloroethane by solvent desorption-gas chromatography in workplace air
Jing YUAN ; Weiming XIE ; Fan WU ; Jiaheng HE ; Jiawen HU ; Ruibo MENG ; Weifeng RONG ; Banghua WU ; Chuan WU
China Occupational Medicine 2023;50(2):185-188
6.Simultaneous determination of six aniline compounds in workplace air by high performance liquid chromatography
Ruibo MENG ; Jingjing QIU ; Weifeng RONG ; Weimin XIE ; Jing YUAN ; Jiaheng HE ; Jiawen HU ; Ziqun ZHANG ; Zuokan LIN ; Fan WU ; Banghua WU
China Occupational Medicine 2023;50(4):441-446
Objective To establish a high performance liquid chromatography (HPLC) method for simultaneous determination of six aniline compounds (ADs) in workplace air. Methods GDH-1 air sampling tube was used to collect six co-existing ADs such as aniline, o-toluidine, N-methylaniline, m-methylaniline, p-methylaniline and N,N-dimethylaniline in the vapor and aerosol of workplace air. The samples were desorbed and eluted using a methanol solution containing 1.00% ammonia water, followed by separation on a C18 chromatographic column and detection using a diode array detector. Results The quantification range of the method was 0.19 -253.50 mg/L, with the correlation coefficient of 0.999 9 for all six ADs. The minimum detection range was 0.02-0.06 mg/m3, and the minimum quantitation range was 0.04-0.19 mg/m3 [both calculated for a 15.0 L sample with a desorption (elution) solution volume of 3.00 mL]. The average desorption and elution efficiencies were 92.15%-104.41% (silica gel) and 94.29%-104.29% (filter membrane). The intra-assay relative standard deviation (RSD) ranged from 0.90%-9.72% (silica gel) and 0.57%-6.96% (filter membrane). The inter-assay RSD ranged from 2.03%-9.78% (silica gel) and 2.50%-8.62% (filter membrane). The samples were stable at room temperature for seven days. Conclusion This method can be used for the simultaneous determination of six ADs in workplace air.
7.Analysis of the regular monitoring of occupational hazards in Guangdong Province in 2022
Zuofei XIE ; Zuokan LIN ; Jiaheng HE ; Jing YUAN ; Jiawen HU ; Ruibo MENG ; Weifeng RONG ; Banghua WU ; Chuan WU
China Occupational Medicine 2023;50(4):466-471
Objective To analyze the overall situation of regular monitoring of occupational hazards in enterprises in Guangdong Province in 2022. Methods Analysis and quality sampling from enterprises were conducted on the occupational hazard regular monitoring reports submitted by various occupational health institutions through the Guangdong Province Occupational Health Quality Control Platform for the year 2022. Results In 2022, a total of 40 129 enterprises in Guangdong Province conducted regular monitoring of occupational hazards, accounting for 5.9%. More than 4.85 million workers were enrolled, of which more than 1.99 million workers were exposed to occupational hazards, with an incidence of 41.1%. The incidence of exposure to chemicals, dust, and noise were 18.2%, 11.9%, and 23.5%, respectively. The incidence of exceeding national standard for chemical substances, dust and noise in enterprises were 2.7%, 3.3%, and 42.7%, respectively. The incidence of exceeding national standard for all occupational hazards increased with the scale of enterprises from micro, small, medium to large enterprises (29.1% vs 46.7% vs 61.3% vs 65.4%, all P<0.05). The top three key industries, with more enterprises exceeding national standard, were metal furniture manufacturing, wooden furniture manufacturing, and other metal daily necessities manufacturing. The concentration of 97 chemical hazardous agents such as silica dust and benzene in work site exceeded the national standard, but less than 1.0% chemical hazardous agents exceeded national standard in most of the chemical-exposed work site. The incidence of noise exceeding national standard was 45.4%, while the incidence of silica dust exceeding national standard was 17.3%. Conclusion The percentage of regular monitoring of occupational hazards in enterprises in Guangdong Province is relatively low. The main occupational hazard that exceeds the national standard was noise, indicating the need for special attention on noise protection in workplace.
8.Advances in rapid detection methods of biotoxins in blood
Wenjie ZHANG ; Yiru QIN ; Zuofei XIE ; Anping MA ; Jingjing QIU ; Zuokan LIN ; Jiaheng HE ; Zhanhong YANG ; Weifeng RONG ; Banghua WU
China Occupational Medicine 2024;51(5):575-580
Biotoxins, which include bacterial, fungal, marine, plant, and animal toxins, are widespread in living and occupational environments, posing potential threats to human health. Rapid detection of biotoxins in blood is crucial for preventing health hazards and enabling timely disease diagnosis and treatment. Biosensors and immunoassay technologies have critical advantages in the rapid detection of biotoxins in blood. Common biosensors, such as surface plasmon resonance biosensors and fluorescent biosensors, enhance sensitivity and reduce detection limits through signal amplification. Common immunoassay methods, such as colloidal gold immunochromatography, fluorescence immunochromatography, and chemiluminescence immunoassay, improve detection efficacy and sensitivity through specific antibody-antigen binding and nanotechnology. However, current rapid detection technologies of bitoxins in blood face challenges such as matrix interference and insufficient specificity, and they fall short in high-throughput detection of multiple toxins simultaneously. Future developments should focus on improving sample pretreatment, innovating signal amplification methods, enhancing specificity on recognition of elements, and designing portable detection devices and high-throughput platforms for simultaneous toxin analysis. These advancements aim to improve the sensitivity and reliability of detection methods, providing more accurate and convenient solutions for biotoxin detection in blood.
9. Determination of difluorochloromethane in workplace air by direct injection gas chromatography
Jiawen HU ; Weifeng RONG ; Meizhen GAO ; Ruibo MENG ; Jiaheng HE ; Delin XIE ; Banghua WU
China Occupational Medicine 2020;47(04):475-477
OBJECTIVE: To establish a method of determination of difluorochloromethane in workplace air by direct sampling gas chromatography. METHODS: Difluorochloromethane in workplace air was collected with aluminum plastic composite film airbag and then directly injected. Difluorochloromethane was separated by DB-1 capillary column and detected with hydrogen flame ionization detector. RESULTS: Good linearity was obtained in the range of 1.50-15 042.90 mg/m~3 with the correlation coefficient of 0.999 96. The limit of detection was 1.26 mg/m~3 and the limit of quantitation was 3.78 mg/m~3. The minimum detection concentration was 1.26 mg/m~3 and the minimum quantification concentration was 3.78 mg/m~3. The standard recovery was 98.34%-99.19%. The within-run relative standard deviation(RSD) and the between-run RSD were 1.82%-3.72% and 2.17%-4.17%, respectively. The samples can be stored at room temperature for at least 7 days. CONCLUSION: This method is suitable for difluorochloromethane detection in workplace air.