1.Expression and Significance of Discoidin Domain Receptor 1 in Tumors of Digestive System
Jiachun YANG ; Yanni MENG ; Leiming XU
Chinese Journal of Gastroenterology 2016;21(6):366-368
Discoidin domain receptor 1(DDR1)is a kind of receptor tyrosine kinases(RTKs),which is expressed abnormally in many tumors. It is involved in the development,invasion and metastasis process of tumors and may become a potential target of tumor therapy. This article reviewed the expression and significance of DDR1 in tumors of digestive system.
2.Comparative study on neuroethology and pathology in rat model with spontaneous hypertension and persistent hypoperfusion
Song QIAO ; Jiachun FENG ; Jing YANG
Medical Journal of Chinese People's Liberation Army 1981;0(06):-
Objective To investigate the potential mechanisms of vascular dementia (VD) by comparing the neuroethological and pathological changes of two VD models, established with spontaneously hypertensive rat (SHR) and the rat, of which the bilateral carotid arteries were ligated. Methods Ten male SHRs were employed and defined as hypertension control group. Thirty male Wistar rats were randomly assigned to operation group (bilateral carotid arteries were ligated), sham group and control group. All rats enrolled in the operation group were undergone a permanent ligation of bilateral carotid artery (2-VO). The memory function of rats was estimated by the mean escape latency of Morris water maze. The morphological changes of neuron cells in the frontal lobe, temporal lobes, hippocampus and thalami were observed with HE staining, while the changes of white matter around cerebral ventricles were checked with LFB staining, and the demyelination of nerve was calculated. Results The memory function of rats in SHR control group and Wistar operation group was decreased compared with that of the rats in sham group and control group (P0.05). Conclusions SHRs without intervention and Wistar rats undergone 2-VO can be used to reproduce the ideal VD model. Both chronic permanent hypoperfusion and hypertension may lead to the loss of neurons and myelin which may result in memory dysfunction. Hypoperfusion is even more harmful than hypertension. The present study suggests that loss of neurons and myelin may play a role in the VD.
3.Clinical characteristics and cerebral blood flow in 15 patients of progressive stroke
Yi YANG ; Jiang WU ; Jiachun FENG ; Wei YANG ; Jing WANG ; Wenhua LIN ; Jia LIU
Chinese Journal of Neurology 2008;41(9):607-609
Objective To observe the clinical characteristics of progressive stroke (PS) patients with vascular stenosis and the relationship between PS and cerebral blood flow (CBF). Methods Fifteen patients of PS with anterior circulation vascular stenosis were chosen, their clinical documents and CBF were analyzed with Xenon-CT when they were in progression. Results These patients mostly presented hemiparalysis and language dysfunction at the beginning ( 13/15 ) before the disease developed rapidly into a serious state. The infarction usually happens in the periventricular area (10/15). Upper limbs paralyzed more severely than low limbs(11/15). Cerebral hypoperfusion areas around the infarction in 11 patients ( 10 ml·100 g-1·min-1 < CBF < 20 ml·100 g-1·min-1 ) were found. Conclusions Patients of PS with vascular stenosis present typically clinical characteristics, Low CBF caused by cerebral artery stenosis may be one of the most important factors leading to PS.
4.Intraoperative transesophageal echocardiography in robot-assisted minimally invasive cardiac surgery
Yao WANG ; Changqing GAO ; Ming YANG ; Cangsong XIAO ; Gang WANG ; Jiali WANG ; Jiachun LI ; Yansong SHEN
Chinese Journal of Thoracic and Cardiovascular Surgery 2011;27(7):401-403
Objective To delineate the utility and results of intraoperative transesophageal echocardiography (TEE) in the evaluation of patients undergoing robot-assisted cardiac surgery. Methods Intraoperative TEE was performed in 193 patients undergoing robot-assisted procedures in cardiac surgery over a period of 4 years. (1) Before CPB, a comprehensive TEE was performed to document the lesions and their precise localization. ( 2 ) During establishment of peripheral CPB, a arterial cannula was placed percutaneously into the right internal jugular vein and passed into the superior vena cava; a venous cannula was inserted into the right common femoral vein and passing it into the inferior vena cava with its tip just inferior to the inferior vena cava-right atrium junction; a arterial perfusion cannula was passed into the ascending aorta with its tip approximately 3 cm from the aortic valve under TEE guidance. (3) After weaning from CPB, TEE was performed to evaluate the efficiency of the procedure. Results (1) The concordance with surgical findings concerning the lesions and precise localization was 100% and 98. 8% among all the patients, respectively. (2) All cannulae were located in the correct position. (3) TEE confirmed successful procedures with no concomitant complication in all the patients. Conclusion Intraoperative TEE is a valuable adjunct in the assessment of robot-assisted cardiac surgery.
5.Septal anterior ventricular exclusion operation for left ventricular anterior aneurysm:effects on left ventricular shape,volume and function by intraoperative transesophageal echocardiography
Yao WANG ; Changqing GAO ; Gang WANG ; Yang WU ; Weihua YE ; Guopeng LIU ; Jiachun LI ; Jiali WANG
Chinese Journal of Ultrasonography 2008;17(8):657-660
Objective To assess the effects of septal anterior ventricular exclusion(SAVE)procedure on left ventricular(LV)shape,volume and function in patients with post-infarction LV anterior aneurysm by intraoperative transesophageal echocardiography(TEE).Methods Twenty patients with LV anterior aneurysm underwent surgical ventrieular restoration(SVR)with the SAVE procedure.Intraoperative TEE was performed before cardiopulmonary bypass(CPB)and after weaning from CPB.LV volume and ejection fraction(EF)was measured using the biplane Simpson's method.LV end-diastolic and end-systolic volumes,indexed by body surface area(EDVI and ESVI,respectively)were calculated.To estimate the shape of LV,end-diastolic sphericity index(SI)of LV was determined.Results Compared with pre- CPB,after SVR,LV shape became more elliptical:SI increased from 0.76±0.04 to 0.84±0.05,P<0.001.LV size became more normal:EDVI decreased from(121.51±16.91)ml/m2 to(60.27±9.93)ml/m2,P<0.001,and ESVI decreased from(85.81±15.02)ml/m2 to (32.44±5.36)ml/m2,P<0.001,respectively.EF was increased significantly:(46.02±3.90)% vs(29.52±6.0)%,P<0.001.Conclusions The SAVE technique is easy to reshape LV to ellipsoid fogln and normal size and the resultant improved configuration may contribute to improving EF for patients with post-infarction LV anterior aneurysm.
6.The importance of intraoperative transesophageal echocardiography in totally endoscopic atrial septal defect repair with robotic assistance
Yao WANG ; Changqing GAO ; Gang WANG ; Jiali WANG ; Cangsong XIAO ; Ming YANG ; Jiachun LI
Chinese Journal of Ultrasonography 2008;17(6):461-464
Objective To explore the importance of intraoperatlVe transesophageal echocardlography(TEE) in totally endoscopic atrial septal defect(ASD)repair.Methods Twenty four patients underwent repair of ASD by a totally endoscopic approach,utilizing the da Vinci S robotic system.After induction of general anesthesia and a left-sided double-lumen endotracheal tube was positioned,a TEE probe was inserted.①Before cardiopulmonary bypass(CPB),TEE examination was conducted to document the types and size of ASD.The procedures were predetermined by the operator according to the TEE diagnosis.②CPB was achieved peripherally.With TEE guidance,a 19-or 21-Fr.femoral venous cannula was inserted into the right common femoral vein and passing it into the inferior vena cava(IVC),with its tip just inferior to the IVC-right atrium junction;a 15-or 17-Fr.femoral arterial eannula was placed percutaneously into the right internal jugular vein and passed into the superior vena cava(SVC).The bypass circuit was completed by inserting a 14G arterial perfusion cannula into the ascending aorta(AAO),with its distal tip passing over the center of the AAO,approximately 3 cm from the aortic valve.③ After weaning from CPB,TEE examination was performed again.Results①Surgical confirmation was obtained in all the patients and no operative procedures were changed.②All venous,arterial and arterial perfusion cannula were located in correct position.③In all patients,TEE after weaned from CPB confirmed successful repair.Conclusions Intraoperative TEE is essential for totally endoscopic ASD repair.
7.Aβ25-35 protein in different concentrations to create a rat model resembling Alzheimer's disease and the differences in their learning and memory ability
Kai WANG ; Qiang LI ; Weiming SUN ; Jiachun XU ; Wei GUO ; Yang CAO ; Zhen ZHOU
Chinese Journal of Comparative Medicine 2017;27(3):14-19
Objective To observe the learning and memory ability of rats after injection of Aβ25-35 protein in different concentrations into the lateral ventricle assessed by Morris water maze test, and to explore the optimal concentration of Aβ25-35 in the preparation of AD model rats.Methods Male SD rats were randomly divided into sham operated group and model group.The rats of model group received Aβ25-35 injection in concentrations of 2 μg/μL, 4 μg/μL and 8 μg/μL, respectively.According to the Rat Brain Stereotaxic Atlas, 5 μL of aggregation of Aβ25-35 was injected into the right lateral ventricle to establish the AD rat model.7 days after successful modeling, Morris water maze was used to test thechanges of learning and memory ability of the rats.Results There was no significant difference in the average swimming speed between the two groups (P > 0.05).The escape latency time of rats in the model group was significantly increasedcompared with the sham group (P < 0.05).In the model group, the escape latency time of rats treated with 4 μg/μL and 8 μg/μL Aβ25-35 was significantly increased compared with the rats injected with 2 μg/μL (P < 0.05), while there was no significant difference between rats treated with 4 μg/μL and 8 μg/μL Aβ25-35 (P > 0.05).The activity time and distance of target quadrant of the rats injected with different concentration of Aβ25-35in the model group were significantly reduced compared with the sham group (P < 0.05), but no significant difference amongthe rats treated with different Aβ25-35 concentrations (P > 0.05).Compared with the sham-operated group, the number of platform-crossing of rats injected with different doses of Aβ25-35in the model group were significantly reduced (P < 0.05).In the model group, the rats treated with 4 μg/μL and 8 μg/μL was significantly reduced compared with the group with 2 μg/μL injection (P < 0.05).There was no significant difference between the rats injected with 4 μg/μL and 8 μg/μL (P > 0.05).Conclusions The recommended dose and concentration of Aβ25-35 to be injected into the unilateral ventricle to establisha rat model of Alzheimer's disease is 4 μg/μL in a volume of 5 μL.
8.Simultaneous Determination of Echinacoside, Acteoside and Isoacteoside in Total Cistanchis glycosides Capsules by HPLC
Sude YANG ; Junhua HU ; Jiachun LI ; Zhongkun XU ; Yu'an BI ; Wei XIAO ;
World Science and Technology-Modernization of Traditional Chinese Medicine 2015;17(3):609-613
This study was aimed to establish an HPLC method for simultaneous determination of the content of echinacoside, acteoside and isoacteoside in Total Cistanchis glycosides Capsules. Waters C18 column (4.6 mm ×150 mm, 5 μm) was used with the mobile phase of methanol-0.1% formic acid at a flow rate of 1.0 mL·min-1. The detection wavelength was set at 330 nm. The column temperature was maintained at 30℃ . The results showed that the linear ranges of echinacoside, acteoside and isoacteoside were in the range of 27.792-277.92 μg·mL-1 (r = 0.9996,n = 6), 2.4184-24.184 μg·mL-1 (r = 0.9996, n = 6), 5.106-51.06 μg·mL-1 (r = 0.9998, n = 6). The average recoveries of three components were in accordance with the determination requirement. It was concluded that the method was simple and accurate, which can be used in the content determination of echinacoside, acteoside and isoacteoside in Total Cistanchis glycosides Capsules.
9.The choise of port access for robotic minimally invasive heart surgery using da Vinci S system
Ming YANG ; Changqing GAO ; Gang WANG ; Jiali WANG ; Cangsong XIAO ; Yang WU ; Rong WANG ; Lixia LI ; Yue ZHAO ; Jiachun LI
Chinese Journal of Thoracic and Cardiovascular Surgery 2011;27(7):387-389
Objective Subject To summary the port placement and system set-up for robotic minimally invasive heart surgery using da Vinci S system in China. Methods 400 patients accepted selective robotic minimally invasive heart surgery from January 2007 to January 2011. We conducted a retrospective review of port placement and system set-up for all the surgeries. During the surgery 3-4 ports were made in the lateral thoracic wall and the position of ports were modulated according to the types of diseases, the procedure and patients' habitus. The surgeon completed the procedure before the surgeon console.The arms of da Vinci S system was adjusted according to surgery procedure. Results The right lateral ports were suitable for the intracardiac operation with extracorporeal circulation. And the left lateral ports can be used in the inner thoracic artery harvesting and coronary bypass graft on beating heart. Except for 1 case changed to sternotomy because of sever pleural adhesions,no arms collision and mechanical malfunction during the surgery that leaded to surgical conversion. Conclusion Robotic minimally invasive heart surgery can be safely applied to partial cardiac surgeries. The port position and system set-up should be adjusted according to the habitus of patients and surgical requirement.
10.Treatment of multiple vessel coronary artery diseaseby robotic bypass surgery on the beating heart and stent placement in distinct hybrid session
Changqing GAO ; Ming YANG ; Yang WU ; Gang WANG ; Congsong XIAO ; Jiachun LI ; Jiali WANG ; Lixia LI ; Yue ZHAO ; Qi ZHOU
Chinese Journal of Thoracic and Cardiovascular Surgery 2011;27(7):398-400
Objective Summary the first group of robotic bypass surgery on the beating heart and stent placement in distinct hybrid session in China. Methods 163 cases patients accepted selective operation of robotic coronary bypass grafting on the beating heart form April 2007 to January 2011. 12 cases had multi coronary vessels stenosis accepted stent placement after robotic surgery in a hybrid manner. The average age of patients was ( 56. 0 ± 9.74 ) years old. 3 case was female and 9 cases were male. All the patients had a medical history of angina. The coronary arterioangiography showed sever left anterior descend ing or diagonal branch stenosis in all patients. And 4 cases had myocardial infarction history. All the patients had good lung function and had no medical history of pleurisy. Without sternotomy, through 3 ports about 1 cm in left thorax, the left internal mammary artery was obtained and simultaneously single vessel coronary artery bypass grafting through small thoracotomy or totally endoscopic coronary bypass (TECAB) was performed on beating heart. The bridge patency and revascularization was accessed by arterioangiography. Results All cases successfully accepted robotic bypass surgery on the beating heart and stent placement in distinct hybrid session without complication. Conclusion Hybrid coronary artery revascularization enable adequate revascularization of patients with multivessel coronary artery disease without sternotomy and with the advantage of the most durable option.