1.Clinical observation on wound measurement grid and perforator flap design
Xuelang YE ; Shan HUANG ; Wanggao ZHOU ; Zhenwei ZHANG ; Shaoxiao YU ; Yi XIONG ; Huixin LIN ; Dongyang LI ; Jiachuan ZHUANG
Chinese Journal of Microsurgery 2022;45(1):46-49
Objective:To investigate the application of self-designed wound measuring grid in the measurement of wound and the design of perforator flap.Methods:From February 2018 to February 2020, 31 cases of soft tissue defects of limbs were repaired by free transfer of perforator flap. During the operation, the self-designed membrane with measurement grid was used to measure the wound surface. The flaps were designed and harvested according to the accurate measurement of the wound. The flaps were reviewed at hospital clinic during follow-up.Results:All patients entered 3-15 months of follow-up with an average of 8 months. All 31 flaps survived, of which 2 flaps encountered vascular crisis and were rescued after surgical exploration. There was no infection of flaps and all flaps had stage I healing. The flaps were satisfactory in appearance with the sensation recovery to S 2 in 21 cases and S 3 in 10 cases. Only linear scars were left on the donor sites. Conclusion:The membrane with a measurement grid can accurately measure a wound, and help the design of the flap according to the measured size and profile of the wound. It can reduce the operation time and the risk as well as to improve the operation efficiency. The clinical application is satisfactory. Large scale and multi-centre studies are required to further prove the benefit of the measurement grid.
2.A self-designed wound measurement grid in design of lobulated perforator flap
Wanggao ZHOU ; Xuelang YE ; Zhenwei ZHANG ; Jiachuan ZHUANG ; Dongyang LI ; Shaoxiao YU ; Zheng LI ; Yuhai KE ; Huixin LIN ; Yi XIONG
Chinese Journal of Microsurgery 2023;46(5):552-557
Objective:To explore the clinical effect of a self-designed wound measurement grid on the design of lobulated perforator flap.Methods:From January 2019 to December 2022, soft tissue defects in limbs of 9 patients were reconstructed by lobulated perforator flaps in the Department of Orthopaedics and Traumatology of Shenzhen Hospital of Integrated Traditional Chinese and Western Medicine. The patients were 7 males and 2 females aged 21-55 years old with 40.3 years old in average. There were 6 upper limb defects and 3 lower limb defects. Self-designed wound measuring grids were applied to guide the design and excision of lobulated perforator flaps during surgery. Five patients were treated by lobulated perforator flap pedicled with the descending branch of lateral circumflex femoral artery and 4 by perforator flaps pedicled with dorsal interosseous artery. The areas of soft tissue defect were 4.0 cm×1.5 cm-26.0 cm×8.0 cm, and the sizes of the flaps were 4.5 cm×1.8 cm-22.0 cm×10.0 cm. After surgery, the blood supply of flaps, flap survival and wound healing were monitored. Flap survival, donor site recovery and limb function were observed at outpatient clinic over the postoperative follow-up, and the limb function was evaluated by the Evaluation Standard of Upper Limb Partial Functional of Hand Surgery of Chinese Medical Association and Lower Extremity Measure(LEM).Results:In this study, a total of 17 of 18 lobes of the lobulated perforator flaps survived after surgery. One flap had venous occlusion and after exploration and further treatment, a necrosis occurred in 1 lobe of the lobulated flap and then a free flap transfer was performed again. All the wounds achieved stage-I healing. Postoperative follow-up lasted for 3-18 months with 8.6 months in average. All flaps had good colour and texture, satisfactory appearance and only linear scars remained in the donor sites, without pain and scar contracture. The reconstructed upper extremity defect were evaluated according to the Evaluation Standard of Upper Limb Partial Functional of Hand Surgery of Chinese Medical Association, with 4 patients were in excellent and 2 in good. The reconstructed lower extremity defects were evaluated according to the LEM, and 2 patients were in excellent and 1 in good.Conclusion:The self-designed wound measurement grid was successfully applied in the design of lobed perforator flaps. It can accurately measure a wound surface and quickly extract a wound profile, and it is more convenient and intuitive to guide the design of flaps. It has a good effect in clinical application and further clinical trials are required.
3.Diagnostic Value of Conventional Ultrasound Combined with Shear Wave Elastography for Sarcopenia in Patients with Chronic Kidney Disease
Xiaozhu ZHONG ; Jiachuan LIN ; Qirong SONG ; Sha FU ; Ting SHU ; Ying TANG ; Ping WANG
Journal of Sun Yat-sen University(Medical Sciences) 2024;45(6):912-922
[Objective]To explore the diagnostic value of conventional ultrasound combined with shear wave elastography (SWE) for sarcopenia in patients with chronic kidney disease (CKD).[Methods]The study included 94 CKD patients (34 with sarcopenia and 60 without). All patient underwent the Simplified Assessment Rating Questionnaire (SARC-CalF),Mini Nutritional Assessment (MNA),Short Physical Performance Battery (SPPB),grip strength test,bioelectrical impedance analysis (BIA),conventional muscle ultrasound and SWE of the thighs. We then compared the differences in indicators between the sarcopenia group and non-sarcopenia group,used Spearman correlation analysis to assess the relationship between the two examinations (conventional ultrasound and SWE) and other clinical indicators,identified the diagnostic markers for sarcopenia,created receiver operating characteristic (ROC) curves,calculated the area under the curve (AUC) and determined the diagnostic performance of conventional ultrasound,SWE and their combination. Binary logistic regression was used to analyze the influencing factors of sarcopenia in CKD patients and a combined diagnosis model was established.[Results]The sarcopenia group showed lower upper arm circumference,calf circumference,6-meter walking speed and handgrip strength than non-sarcopenia group,and the differences were statistically significant (P<0.05). The sarcopenia group exhibited lower SARC-CalF and SPBB scores,as well as more compromised nutritional status. Statistically significant differences were observed in the ultrasound parameters between the two groups,including thickness of the subcutaneous fat and rectus femoris,combined thickness of the rectus femoris and vastus intermedius,rectus femoris cross-sectional area,elastic modulus of the rectus femoris and vastus medialis (all P<0.05). The muscle mass index had a moderate positive correlation with muscle thickness and cross-sectional area of the rectus femoris (0.3