1.Clinical observation of fluorescence endoscopy in medical diagnosis.
Yanming YE ; Zhizheng GE ; Shudong XIAO ; Shuai GONG ; Jiabiao ZHENG ; Jingfang XIA ; Xiang YE
Chinese Journal of Medical Instrumentation 2013;37(6):457-459
It's difficult to diagnose precancerous lesion and early cancer for a long time, because both of them haven't typical morphological characteristics. As a novel diagnostic modality, fluorescence endoscopy can accurately reflect minimal changes in human's tissue, thus making a meaningful progress for cancer diagnosing. 200 patients were examined by fluorescence endoscopy to evaluate the diagnostic value. The overall accuracy, sensitivity and specificity for detecting malignant gastrointestinal tumor was 94.0%, 94.6% and 93.5%, respectively. Thus, fluorescence endoscopy can be used to diagnose malignant gastrointestinal tumors with high validity and reliability, and is advantageous over conventional white light endoscopy especially in detecting the atypical and suspicious lesions. Furthermore, fluorescence endoscopy can also guide target biopsy, is significant to improve the early cancer detection rate, has a broad development prospect.
Endoscopy
;
instrumentation
;
Fluorescence
;
Gastrointestinal Neoplasms
;
diagnosis
;
Humans
;
Sensitivity and Specificity
2.Study of clinical application on autofluorescence imaging in the diagnosis of early cancer.
Ye YANMING ; Xiao SHUDONG ; Ge ZHIZHENG ; Zheng JIABIAO ; Xia JINGFANG ; Jing ZHIMIN
Chinese Journal of Medical Instrumentation 2010;34(1):62-65
The mechanism and principles of autofluorescence imaging based on autofluorescence technique are reported. The threshold value of fluorescence spectrum ratio applied can be quantitative and objective and the reliable measurement method that may provide intuitive method of autofluorescence imaging in the gut mucosa. The suspected lesion may be found rapidly according to the imaging color difference, therefore the results of clinical study of the digestive tract cancer diagnosis indicated that the sensitivity, specificity, and diagnostic accuracy were 94%, 95.5% and 94.8% respectively, and it has very high value in clinical application.
Digestive System Neoplasms
;
diagnosis
;
Early Detection of Cancer
;
instrumentation
;
methods
;
Endoscopy, Digestive System
;
instrumentation
;
Fluorescence
;
Humans
;
Photofluorography
;
Sensitivity and Specificity
3.Effect of modified auricle cartilage nasal septum extension stent on rhinoplasty
Jiabiao REN ; Huanhuan DING ; Liangping WANG ; Hongmei TANG ; Zheng TAN
Chinese Journal of Medical Aesthetics and Cosmetology 2021;27(2):109-112
Objective:To introduce a modified stent technique of nasal septal extension graft (SEG) with auricle cartilage, and to explore its effect on rhinoplasty.Methods:For 116 patients that underwent rhinoplasty, the cartilage of bilateral auricula was sutured with shell alignment and the dovetail was modified to prepare SEG stent; PTFE or silicone prosthesis was used for nasal dorsal graft. The patients were follow up for 6-18 months after surgery. A number of indicators including length of nose, tip projection, nasal tip and nasolabial angle morphology were used to assess surgical outcomes.Results:The 116 patients obtained satisfactory appearance immediately after operation. Length of nasal extension was 3-6 mm, tip projection was extended by 2-5 mm. Following up for 6-18 months showed stable effect (0.5-1.5 mm retraction) and satisfactory nose tip and nasolabial angle. The skin color was normal. No deformity occured in the ear cartilage donor area existed with no obvious scar.Conclusions:The modified SEG stent of auricle cartilage has good support and stability. It has a good effect on the slight and moderate extension of the short nose. In addition, the elevation of the nasal tip and the severe short nose of the first rhinoplasty and secondary rhinoplasty with mild contracture are also improved.